Industrial fan noise control using flow obstructions

Fans are used in a lot of industrial processes and are sometimes a source of important noise for workers. The first aim of this study was to identify some problematic fans in Québec industries, for which the noise exposure exceeds the CSST (Comission de la santé et sécurité au travail) limit of 90 d...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of the Acoustical Society of America 2013-05, Vol.133 (5_Supplement), p.3264-3264
Hauptverfasser: Oddo, Remy, Gérard, Anthony, Pearson, Michel, Amyotte, Adrien, Masson, Patrice, Sgard, Franck, Berry, Alain
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 3264
container_issue 5_Supplement
container_start_page 3264
container_title The Journal of the Acoustical Society of America
container_volume 133
creator Oddo, Remy
Gérard, Anthony
Pearson, Michel
Amyotte, Adrien
Masson, Patrice
Sgard, Franck
Berry, Alain
description Fans are used in a lot of industrial processes and are sometimes a source of important noise for workers. The first aim of this study was to identify some problematic fans in Québec industries, for which the noise exposure exceeds the CSST (Comission de la santé et sécurité au travail) limit of 90 dBA for 8 h. We have focused on fans having a high tonal content, for which the Simple Silence technology can be applied, i.e., tonal fan noise control using obstructions in the flow. Two analytical models of the tonal noise radiated by these fans have been proposed: a free field model based on the Lowson model and an in-duct model based on the Goldstein model. The first free-field model has been applied to the control of the noise from a series of eight evaporator fans, having a strong blade passage frequency (BPF) tone at 90 Hz. These fans have been controlled in-situ, in a cold storage room, using trapezoidal obstructions in the downstream flow field of the fans. The second in-duct model has been applied to control the tonal noise from an in-duct air-extractor fan used in the underground gold mining galleries. Several obstructions have been tested in the upstream flow field.
doi_str_mv 10.1121/1.4805286
format Article
fullrecord <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_1121_1_4805286</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1121_1_4805286</sourcerecordid><originalsourceid>FETCH-LOGICAL-c746-3dd2a79e727ae04f9576bf752254356ac3f2ab58165ce62ca9a850be5df55043</originalsourceid><addsrcrecordid>eNotj8tKAzEYRoNYcGxd-AbZupia25_LUoraQsGF7kMmk0hkTCSZQXx7K3Z1-ODwwUHolpItpYze063QBJiWF6ijwEivgYlL1BFCaC-MlFfourWP0wTNTYfEIY9Lm2tyE44u41xSC9iXPNcy4aWl_I7jVL5xGU7W4udUctugVXRTCzdnrtHr0-Pbbt8fX54Pu4dj75WQPR9H5pQJiikXiIgGlByiAsZAcJDO88jcAJpK8EEy74zTQIYAYwQggq_R3f-rr6W1GqL9qunT1R9Lif2LtdSeY_kvqXxGQQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Industrial fan noise control using flow obstructions</title><source>AIP Journals Complete</source><source>Alma/SFX Local Collection</source><source>AIP Acoustical Society of America</source><creator>Oddo, Remy ; Gérard, Anthony ; Pearson, Michel ; Amyotte, Adrien ; Masson, Patrice ; Sgard, Franck ; Berry, Alain</creator><creatorcontrib>Oddo, Remy ; Gérard, Anthony ; Pearson, Michel ; Amyotte, Adrien ; Masson, Patrice ; Sgard, Franck ; Berry, Alain</creatorcontrib><description>Fans are used in a lot of industrial processes and are sometimes a source of important noise for workers. The first aim of this study was to identify some problematic fans in Québec industries, for which the noise exposure exceeds the CSST (Comission de la santé et sécurité au travail) limit of 90 dBA for 8 h. We have focused on fans having a high tonal content, for which the Simple Silence technology can be applied, i.e., tonal fan noise control using obstructions in the flow. Two analytical models of the tonal noise radiated by these fans have been proposed: a free field model based on the Lowson model and an in-duct model based on the Goldstein model. The first free-field model has been applied to the control of the noise from a series of eight evaporator fans, having a strong blade passage frequency (BPF) tone at 90 Hz. These fans have been controlled in-situ, in a cold storage room, using trapezoidal obstructions in the downstream flow field of the fans. The second in-duct model has been applied to control the tonal noise from an in-duct air-extractor fan used in the underground gold mining galleries. Several obstructions have been tested in the upstream flow field.</description><identifier>ISSN: 0001-4966</identifier><identifier>EISSN: 1520-8524</identifier><identifier>DOI: 10.1121/1.4805286</identifier><language>eng</language><ispartof>The Journal of the Acoustical Society of America, 2013-05, Vol.133 (5_Supplement), p.3264-3264</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c746-3dd2a79e727ae04f9576bf752254356ac3f2ab58165ce62ca9a850be5df55043</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>207,208,314,780,784,27923,27924</link.rule.ids></links><search><creatorcontrib>Oddo, Remy</creatorcontrib><creatorcontrib>Gérard, Anthony</creatorcontrib><creatorcontrib>Pearson, Michel</creatorcontrib><creatorcontrib>Amyotte, Adrien</creatorcontrib><creatorcontrib>Masson, Patrice</creatorcontrib><creatorcontrib>Sgard, Franck</creatorcontrib><creatorcontrib>Berry, Alain</creatorcontrib><title>Industrial fan noise control using flow obstructions</title><title>The Journal of the Acoustical Society of America</title><description>Fans are used in a lot of industrial processes and are sometimes a source of important noise for workers. The first aim of this study was to identify some problematic fans in Québec industries, for which the noise exposure exceeds the CSST (Comission de la santé et sécurité au travail) limit of 90 dBA for 8 h. We have focused on fans having a high tonal content, for which the Simple Silence technology can be applied, i.e., tonal fan noise control using obstructions in the flow. Two analytical models of the tonal noise radiated by these fans have been proposed: a free field model based on the Lowson model and an in-duct model based on the Goldstein model. The first free-field model has been applied to the control of the noise from a series of eight evaporator fans, having a strong blade passage frequency (BPF) tone at 90 Hz. These fans have been controlled in-situ, in a cold storage room, using trapezoidal obstructions in the downstream flow field of the fans. The second in-duct model has been applied to control the tonal noise from an in-duct air-extractor fan used in the underground gold mining galleries. Several obstructions have been tested in the upstream flow field.</description><issn>0001-4966</issn><issn>1520-8524</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><recordid>eNotj8tKAzEYRoNYcGxd-AbZupia25_LUoraQsGF7kMmk0hkTCSZQXx7K3Z1-ODwwUHolpItpYze063QBJiWF6ijwEivgYlL1BFCaC-MlFfourWP0wTNTYfEIY9Lm2tyE44u41xSC9iXPNcy4aWl_I7jVL5xGU7W4udUctugVXRTCzdnrtHr0-Pbbt8fX54Pu4dj75WQPR9H5pQJiikXiIgGlByiAsZAcJDO88jcAJpK8EEy74zTQIYAYwQggq_R3f-rr6W1GqL9qunT1R9Lif2LtdSeY_kvqXxGQQ</recordid><startdate>20130501</startdate><enddate>20130501</enddate><creator>Oddo, Remy</creator><creator>Gérard, Anthony</creator><creator>Pearson, Michel</creator><creator>Amyotte, Adrien</creator><creator>Masson, Patrice</creator><creator>Sgard, Franck</creator><creator>Berry, Alain</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20130501</creationdate><title>Industrial fan noise control using flow obstructions</title><author>Oddo, Remy ; Gérard, Anthony ; Pearson, Michel ; Amyotte, Adrien ; Masson, Patrice ; Sgard, Franck ; Berry, Alain</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c746-3dd2a79e727ae04f9576bf752254356ac3f2ab58165ce62ca9a850be5df55043</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Oddo, Remy</creatorcontrib><creatorcontrib>Gérard, Anthony</creatorcontrib><creatorcontrib>Pearson, Michel</creatorcontrib><creatorcontrib>Amyotte, Adrien</creatorcontrib><creatorcontrib>Masson, Patrice</creatorcontrib><creatorcontrib>Sgard, Franck</creatorcontrib><creatorcontrib>Berry, Alain</creatorcontrib><collection>CrossRef</collection><jtitle>The Journal of the Acoustical Society of America</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Oddo, Remy</au><au>Gérard, Anthony</au><au>Pearson, Michel</au><au>Amyotte, Adrien</au><au>Masson, Patrice</au><au>Sgard, Franck</au><au>Berry, Alain</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Industrial fan noise control using flow obstructions</atitle><jtitle>The Journal of the Acoustical Society of America</jtitle><date>2013-05-01</date><risdate>2013</risdate><volume>133</volume><issue>5_Supplement</issue><spage>3264</spage><epage>3264</epage><pages>3264-3264</pages><issn>0001-4966</issn><eissn>1520-8524</eissn><abstract>Fans are used in a lot of industrial processes and are sometimes a source of important noise for workers. The first aim of this study was to identify some problematic fans in Québec industries, for which the noise exposure exceeds the CSST (Comission de la santé et sécurité au travail) limit of 90 dBA for 8 h. We have focused on fans having a high tonal content, for which the Simple Silence technology can be applied, i.e., tonal fan noise control using obstructions in the flow. Two analytical models of the tonal noise radiated by these fans have been proposed: a free field model based on the Lowson model and an in-duct model based on the Goldstein model. The first free-field model has been applied to the control of the noise from a series of eight evaporator fans, having a strong blade passage frequency (BPF) tone at 90 Hz. These fans have been controlled in-situ, in a cold storage room, using trapezoidal obstructions in the downstream flow field of the fans. The second in-duct model has been applied to control the tonal noise from an in-duct air-extractor fan used in the underground gold mining galleries. Several obstructions have been tested in the upstream flow field.</abstract><doi>10.1121/1.4805286</doi><tpages>1</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0001-4966
ispartof The Journal of the Acoustical Society of America, 2013-05, Vol.133 (5_Supplement), p.3264-3264
issn 0001-4966
1520-8524
language eng
recordid cdi_crossref_primary_10_1121_1_4805286
source AIP Journals Complete; Alma/SFX Local Collection; AIP Acoustical Society of America
title Industrial fan noise control using flow obstructions
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-11T22%3A23%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Industrial%20fan%20noise%20control%20using%20flow%20obstructions&rft.jtitle=The%20Journal%20of%20the%20Acoustical%20Society%20of%20America&rft.au=Oddo,%20Remy&rft.date=2013-05-01&rft.volume=133&rft.issue=5_Supplement&rft.spage=3264&rft.epage=3264&rft.pages=3264-3264&rft.issn=0001-4966&rft.eissn=1520-8524&rft_id=info:doi/10.1121/1.4805286&rft_dat=%3Ccrossref%3E10_1121_1_4805286%3C/crossref%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true