Comment on ‘‘Predicting theater chair absorption from reverberation chamber measurements’’ [J. Acoust. Soc. Am. 91 , 1514–1524 (1992)]

The relationship between the measured acoustic absorption coefficient of an array of theater chairs and the ratio of the perimeter length to plan area of the array is considered. It is shown that the linear relationship measured by Bradley in a reverberation chamber and reported in ‘‘Predicting thea...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of the Acoustical Society of America 1993-04, Vol.93 (4), p.2238-2240
Hauptverfasser: Davies, W. J., Lam, Y. W., Orlowski, R. J.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The relationship between the measured acoustic absorption coefficient of an array of theater chairs and the ratio of the perimeter length to plan area of the array is considered. It is shown that the linear relationship measured by Bradley in a reverberation chamber and reported in ‘‘Predicting theater chair absorption from reverberation chamber measurements’’ [J. Acoust. Soc. Am. 91, 1514–1524 (1992)] is to be expected from simple theory. This means that any nonlinear influence of diffracted energy on the relationship is small. Bradley is also unduly harsh on the usefulness of a chair absorption measurement method involving screens. A sample result is given, showing that this method can predict in-situ theater chair absorption with reasonable accuracy.
ISSN:0001-4966
1520-8524
DOI:10.1121/1.406687