Capacitive micromachined ultrasound Doppler velocity sensor

An acoustic Doppler velocity measurement system using microelectromechanical systems (MEMS) capacitive micromachined ultrasound transducer (cMUT) array technology is introduced. This low power acoustic velocity measurement system operates in both transmit and receive modes. The device consists of 64...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of the Acoustical Society of America 2011-04, Vol.129 (4_Supplement), p.2578-2578
Hauptverfasser: Shin, Minchul, Krause, Joshua S., DeBitetto, Paul A., White, Robert D.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2578
container_issue 4_Supplement
container_start_page 2578
container_title The Journal of the Acoustical Society of America
container_volume 129
creator Shin, Minchul
Krause, Joshua S.
DeBitetto, Paul A.
White, Robert D.
description An acoustic Doppler velocity measurement system using microelectromechanical systems (MEMS) capacitive micromachined ultrasound transducer (cMUT) array technology is introduced. This low power acoustic velocity measurement system operates in both transmit and receive modes. The device consists of 64 0.6 mm diameter polysilicon and gold diaphragms, and operates at approximately 180 kHz with a quality factor of 30. Computational predictions suggest that in transmit mode the system will deliver a sound pressure level (SPL) of approximately 66 dB SPL at 1 m from the source with an 11 deg, −3 dB beamwidth when driven with a 12 V excitation. In receive mode, the predicted sensitivity is 2.2 mV/Pa at the preamplifier output. Based on experimentally determined electronic noise densities of approximately 4×10−16 V2/Hz, resolution may be as good as 0 dB SPL in a 5 Hz band. This suggests that with good reflection, a range of approximately 8 m (4 m out and 4 m back) is achievable. Velocity resolution is expected to be on the order of 1 cm/s with a 5 m/s maximum measurable velocity. At this point, all predictions are computational. Fabrication will be complete in the next month and experimental characterization of system performance will be presented at the meeting.
doi_str_mv 10.1121/1.3588517
format Article
fullrecord <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_1121_1_3588517</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1121_1_3588517</sourcerecordid><originalsourceid>FETCH-LOGICAL-c747-f2df466e989655773288ae3c2f3364d68c57f8dd4ed705887aca4fc8698314e33</originalsourceid><addsrcrecordid>eNotj8tqwzAUREVpoG7SRf_A2y6c6up5TVfFfUKgm-yNkK6oi19ISSB_X5dmNQwMwzmM3QPfAgh4hK3UiBrsFStAC16hFuqaFZxzqFRtzA27zflnqRplXbCnxs3Od4fuROXQ-TQNzn93I4Xy2B-Sy9NxDOXLNM89pfJE_bRsz2WmMU9pw1bR9ZnuLrlm-7fXffNR7b7eP5vnXeWtslUUISpjqMbaaG2tFIiOpBdRSqOCQa9txBAUBbtAoXXeqejR1ChBkZRr9vB_u9DlnCi2c-oGl84t8PZPuoX2Ii1_AXCqSTc</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Capacitive micromachined ultrasound Doppler velocity sensor</title><source>American Institute of Physics (AIP) Journals</source><source>Alma/SFX Local Collection</source><source>Acoustical Society of America Digital Library</source><creator>Shin, Minchul ; Krause, Joshua S. ; DeBitetto, Paul A. ; White, Robert D.</creator><creatorcontrib>Shin, Minchul ; Krause, Joshua S. ; DeBitetto, Paul A. ; White, Robert D.</creatorcontrib><description>An acoustic Doppler velocity measurement system using microelectromechanical systems (MEMS) capacitive micromachined ultrasound transducer (cMUT) array technology is introduced. This low power acoustic velocity measurement system operates in both transmit and receive modes. The device consists of 64 0.6 mm diameter polysilicon and gold diaphragms, and operates at approximately 180 kHz with a quality factor of 30. Computational predictions suggest that in transmit mode the system will deliver a sound pressure level (SPL) of approximately 66 dB SPL at 1 m from the source with an 11 deg, −3 dB beamwidth when driven with a 12 V excitation. In receive mode, the predicted sensitivity is 2.2 mV/Pa at the preamplifier output. Based on experimentally determined electronic noise densities of approximately 4×10−16 V2/Hz, resolution may be as good as 0 dB SPL in a 5 Hz band. This suggests that with good reflection, a range of approximately 8 m (4 m out and 4 m back) is achievable. Velocity resolution is expected to be on the order of 1 cm/s with a 5 m/s maximum measurable velocity. At this point, all predictions are computational. Fabrication will be complete in the next month and experimental characterization of system performance will be presented at the meeting.</description><identifier>ISSN: 0001-4966</identifier><identifier>EISSN: 1520-8524</identifier><identifier>DOI: 10.1121/1.3588517</identifier><language>eng</language><ispartof>The Journal of the Acoustical Society of America, 2011-04, Vol.129 (4_Supplement), p.2578-2578</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c747-f2df466e989655773288ae3c2f3364d68c57f8dd4ed705887aca4fc8698314e33</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>207,208,314,776,780,27903,27904</link.rule.ids></links><search><creatorcontrib>Shin, Minchul</creatorcontrib><creatorcontrib>Krause, Joshua S.</creatorcontrib><creatorcontrib>DeBitetto, Paul A.</creatorcontrib><creatorcontrib>White, Robert D.</creatorcontrib><title>Capacitive micromachined ultrasound Doppler velocity sensor</title><title>The Journal of the Acoustical Society of America</title><description>An acoustic Doppler velocity measurement system using microelectromechanical systems (MEMS) capacitive micromachined ultrasound transducer (cMUT) array technology is introduced. This low power acoustic velocity measurement system operates in both transmit and receive modes. The device consists of 64 0.6 mm diameter polysilicon and gold diaphragms, and operates at approximately 180 kHz with a quality factor of 30. Computational predictions suggest that in transmit mode the system will deliver a sound pressure level (SPL) of approximately 66 dB SPL at 1 m from the source with an 11 deg, −3 dB beamwidth when driven with a 12 V excitation. In receive mode, the predicted sensitivity is 2.2 mV/Pa at the preamplifier output. Based on experimentally determined electronic noise densities of approximately 4×10−16 V2/Hz, resolution may be as good as 0 dB SPL in a 5 Hz band. This suggests that with good reflection, a range of approximately 8 m (4 m out and 4 m back) is achievable. Velocity resolution is expected to be on the order of 1 cm/s with a 5 m/s maximum measurable velocity. At this point, all predictions are computational. Fabrication will be complete in the next month and experimental characterization of system performance will be presented at the meeting.</description><issn>0001-4966</issn><issn>1520-8524</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><recordid>eNotj8tqwzAUREVpoG7SRf_A2y6c6up5TVfFfUKgm-yNkK6oi19ISSB_X5dmNQwMwzmM3QPfAgh4hK3UiBrsFStAC16hFuqaFZxzqFRtzA27zflnqRplXbCnxs3Od4fuROXQ-TQNzn93I4Xy2B-Sy9NxDOXLNM89pfJE_bRsz2WmMU9pw1bR9ZnuLrlm-7fXffNR7b7eP5vnXeWtslUUISpjqMbaaG2tFIiOpBdRSqOCQa9txBAUBbtAoXXeqejR1ChBkZRr9vB_u9DlnCi2c-oGl84t8PZPuoX2Ii1_AXCqSTc</recordid><startdate>20110401</startdate><enddate>20110401</enddate><creator>Shin, Minchul</creator><creator>Krause, Joshua S.</creator><creator>DeBitetto, Paul A.</creator><creator>White, Robert D.</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20110401</creationdate><title>Capacitive micromachined ultrasound Doppler velocity sensor</title><author>Shin, Minchul ; Krause, Joshua S. ; DeBitetto, Paul A. ; White, Robert D.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c747-f2df466e989655773288ae3c2f3364d68c57f8dd4ed705887aca4fc8698314e33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Shin, Minchul</creatorcontrib><creatorcontrib>Krause, Joshua S.</creatorcontrib><creatorcontrib>DeBitetto, Paul A.</creatorcontrib><creatorcontrib>White, Robert D.</creatorcontrib><collection>CrossRef</collection><jtitle>The Journal of the Acoustical Society of America</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Shin, Minchul</au><au>Krause, Joshua S.</au><au>DeBitetto, Paul A.</au><au>White, Robert D.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Capacitive micromachined ultrasound Doppler velocity sensor</atitle><jtitle>The Journal of the Acoustical Society of America</jtitle><date>2011-04-01</date><risdate>2011</risdate><volume>129</volume><issue>4_Supplement</issue><spage>2578</spage><epage>2578</epage><pages>2578-2578</pages><issn>0001-4966</issn><eissn>1520-8524</eissn><abstract>An acoustic Doppler velocity measurement system using microelectromechanical systems (MEMS) capacitive micromachined ultrasound transducer (cMUT) array technology is introduced. This low power acoustic velocity measurement system operates in both transmit and receive modes. The device consists of 64 0.6 mm diameter polysilicon and gold diaphragms, and operates at approximately 180 kHz with a quality factor of 30. Computational predictions suggest that in transmit mode the system will deliver a sound pressure level (SPL) of approximately 66 dB SPL at 1 m from the source with an 11 deg, −3 dB beamwidth when driven with a 12 V excitation. In receive mode, the predicted sensitivity is 2.2 mV/Pa at the preamplifier output. Based on experimentally determined electronic noise densities of approximately 4×10−16 V2/Hz, resolution may be as good as 0 dB SPL in a 5 Hz band. This suggests that with good reflection, a range of approximately 8 m (4 m out and 4 m back) is achievable. Velocity resolution is expected to be on the order of 1 cm/s with a 5 m/s maximum measurable velocity. At this point, all predictions are computational. Fabrication will be complete in the next month and experimental characterization of system performance will be presented at the meeting.</abstract><doi>10.1121/1.3588517</doi><tpages>1</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0001-4966
ispartof The Journal of the Acoustical Society of America, 2011-04, Vol.129 (4_Supplement), p.2578-2578
issn 0001-4966
1520-8524
language eng
recordid cdi_crossref_primary_10_1121_1_3588517
source American Institute of Physics (AIP) Journals; Alma/SFX Local Collection; Acoustical Society of America Digital Library
title Capacitive micromachined ultrasound Doppler velocity sensor
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-22T18%3A57%3A56IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Capacitive%20micromachined%20ultrasound%20Doppler%20velocity%20sensor&rft.jtitle=The%20Journal%20of%20the%20Acoustical%20Society%20of%20America&rft.au=Shin,%20Minchul&rft.date=2011-04-01&rft.volume=129&rft.issue=4_Supplement&rft.spage=2578&rft.epage=2578&rft.pages=2578-2578&rft.issn=0001-4966&rft.eissn=1520-8524&rft_id=info:doi/10.1121/1.3588517&rft_dat=%3Ccrossref%3E10_1121_1_3588517%3C/crossref%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true