On the efficiency of 2IFC threshold measurement

A tone intensity-discrimination experiment compared the efficiencies of two threshold-tracking rules used with two-interval, forced-choice (2IFC) methodology. Half of the time, a two-right, one-wrong (“2-1”) level-change rule [H. Levitt, J. Acoust. Soc. Am. 49, 467–477 (1971)] tracked thresholds wit...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of the Acoustical Society of America 1977-12, Vol.62 (S1), p.S96-S96
Hauptverfasser: Schacknow, Paul N., Barth, Craig T.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page S96
container_issue S1
container_start_page S96
container_title The Journal of the Acoustical Society of America
container_volume 62
creator Schacknow, Paul N.
Barth, Craig T.
description A tone intensity-discrimination experiment compared the efficiencies of two threshold-tracking rules used with two-interval, forced-choice (2IFC) methodology. Half of the time, a two-right, one-wrong (“2-1”) level-change rule [H. Levitt, J. Acoust. Soc. Am. 49, 467–477 (1971)] tracked thresholds with a binomial probability of 0.707. The remainder of the data were collected under a five-right, two-wrong (“5-2”) rule which tracked 0.736. Stimuli were 1000 Hz tone bursts (100 msec) presented binaurally over headphones at 70 dB SPL. A fixed step size for changes in ΔI (2 dB) was maintained by adding the increment and standard channels in quadrature. Thresholds were determined for sessions of 40, 55, 70, 85, 100, and 115 2IFC trials. Six thresholds were taken at each session size, for each of the two level-change rules. Thresholds were computed as the mean level of ΔI revisited. Sweat factors [M. M. Taylor and C. D. Creelman, J. Acoust. Soc. Am. 41, 782–787 (1967)] were calculated and averaged across the seven subjects for each of the 12 experimental conditions (session-size x rule). The 2-1 rule generated smaller sweat factors, averaged across sessions, and was thus the more efficient rule. An analysis of variance yielded the additional finding that psychophysical efficiency was independent of session size.
doi_str_mv 10.1121/1.2016477
format Article
fullrecord <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_1121_1_2016477</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1121_1_2016477</sourcerecordid><originalsourceid>FETCH-LOGICAL-c697-dd8c22f24707ea70db957a897854857b60071297a0700aaa96fdb44bb540bc183</originalsourceid><addsrcrecordid>eNotj7FOwzAURS0EEqEw8AdZGdK-59h-9ogiSitV6tLdsh1bDWoSZJehf08RnY7uGa50GHtFWCJyXOGSAypBdMcqlBwaLbm4ZxUAYCOMUo_sqZSv65S6NRVb7af6fIx1TGkIQ5zCpZ5Tzbfr7qpzLMf51NdjdOUnxzFO52f2kNypxJcbF-yw_jh0m2a3_9x277smKENN3-vAeeKCgKIj6L2R5LQhLYWW5BUAITfkgACcc0al3gvhvRTgA-p2wd7-b0OeS8kx2e88jC5fLIL9C7Vob6HtLz6lQuA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>On the efficiency of 2IFC threshold measurement</title><source>AIP Acoustical Society of America</source><creator>Schacknow, Paul N. ; Barth, Craig T.</creator><creatorcontrib>Schacknow, Paul N. ; Barth, Craig T.</creatorcontrib><description>A tone intensity-discrimination experiment compared the efficiencies of two threshold-tracking rules used with two-interval, forced-choice (2IFC) methodology. Half of the time, a two-right, one-wrong (“2-1”) level-change rule [H. Levitt, J. Acoust. Soc. Am. 49, 467–477 (1971)] tracked thresholds with a binomial probability of 0.707. The remainder of the data were collected under a five-right, two-wrong (“5-2”) rule which tracked 0.736. Stimuli were 1000 Hz tone bursts (100 msec) presented binaurally over headphones at 70 dB SPL. A fixed step size for changes in ΔI (2 dB) was maintained by adding the increment and standard channels in quadrature. Thresholds were determined for sessions of 40, 55, 70, 85, 100, and 115 2IFC trials. Six thresholds were taken at each session size, for each of the two level-change rules. Thresholds were computed as the mean level of ΔI revisited. Sweat factors [M. M. Taylor and C. D. Creelman, J. Acoust. Soc. Am. 41, 782–787 (1967)] were calculated and averaged across the seven subjects for each of the 12 experimental conditions (session-size x rule). The 2-1 rule generated smaller sweat factors, averaged across sessions, and was thus the more efficient rule. An analysis of variance yielded the additional finding that psychophysical efficiency was independent of session size.</description><identifier>ISSN: 0001-4966</identifier><identifier>EISSN: 1520-8524</identifier><identifier>DOI: 10.1121/1.2016477</identifier><language>eng</language><ispartof>The Journal of the Acoustical Society of America, 1977-12, Vol.62 (S1), p.S96-S96</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>207,314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Schacknow, Paul N.</creatorcontrib><creatorcontrib>Barth, Craig T.</creatorcontrib><title>On the efficiency of 2IFC threshold measurement</title><title>The Journal of the Acoustical Society of America</title><description>A tone intensity-discrimination experiment compared the efficiencies of two threshold-tracking rules used with two-interval, forced-choice (2IFC) methodology. Half of the time, a two-right, one-wrong (“2-1”) level-change rule [H. Levitt, J. Acoust. Soc. Am. 49, 467–477 (1971)] tracked thresholds with a binomial probability of 0.707. The remainder of the data were collected under a five-right, two-wrong (“5-2”) rule which tracked 0.736. Stimuli were 1000 Hz tone bursts (100 msec) presented binaurally over headphones at 70 dB SPL. A fixed step size for changes in ΔI (2 dB) was maintained by adding the increment and standard channels in quadrature. Thresholds were determined for sessions of 40, 55, 70, 85, 100, and 115 2IFC trials. Six thresholds were taken at each session size, for each of the two level-change rules. Thresholds were computed as the mean level of ΔI revisited. Sweat factors [M. M. Taylor and C. D. Creelman, J. Acoust. Soc. Am. 41, 782–787 (1967)] were calculated and averaged across the seven subjects for each of the 12 experimental conditions (session-size x rule). The 2-1 rule generated smaller sweat factors, averaged across sessions, and was thus the more efficient rule. An analysis of variance yielded the additional finding that psychophysical efficiency was independent of session size.</description><issn>0001-4966</issn><issn>1520-8524</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1977</creationdate><recordtype>article</recordtype><recordid>eNotj7FOwzAURS0EEqEw8AdZGdK-59h-9ogiSitV6tLdsh1bDWoSZJehf08RnY7uGa50GHtFWCJyXOGSAypBdMcqlBwaLbm4ZxUAYCOMUo_sqZSv65S6NRVb7af6fIx1TGkIQ5zCpZ5Tzbfr7qpzLMf51NdjdOUnxzFO52f2kNypxJcbF-yw_jh0m2a3_9x277smKENN3-vAeeKCgKIj6L2R5LQhLYWW5BUAITfkgACcc0al3gvhvRTgA-p2wd7-b0OeS8kx2e88jC5fLIL9C7Vob6HtLz6lQuA</recordid><startdate>19771201</startdate><enddate>19771201</enddate><creator>Schacknow, Paul N.</creator><creator>Barth, Craig T.</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>19771201</creationdate><title>On the efficiency of 2IFC threshold measurement</title><author>Schacknow, Paul N. ; Barth, Craig T.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c697-dd8c22f24707ea70db957a897854857b60071297a0700aaa96fdb44bb540bc183</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1977</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Schacknow, Paul N.</creatorcontrib><creatorcontrib>Barth, Craig T.</creatorcontrib><collection>CrossRef</collection><jtitle>The Journal of the Acoustical Society of America</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Schacknow, Paul N.</au><au>Barth, Craig T.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>On the efficiency of 2IFC threshold measurement</atitle><jtitle>The Journal of the Acoustical Society of America</jtitle><date>1977-12-01</date><risdate>1977</risdate><volume>62</volume><issue>S1</issue><spage>S96</spage><epage>S96</epage><pages>S96-S96</pages><issn>0001-4966</issn><eissn>1520-8524</eissn><abstract>A tone intensity-discrimination experiment compared the efficiencies of two threshold-tracking rules used with two-interval, forced-choice (2IFC) methodology. Half of the time, a two-right, one-wrong (“2-1”) level-change rule [H. Levitt, J. Acoust. Soc. Am. 49, 467–477 (1971)] tracked thresholds with a binomial probability of 0.707. The remainder of the data were collected under a five-right, two-wrong (“5-2”) rule which tracked 0.736. Stimuli were 1000 Hz tone bursts (100 msec) presented binaurally over headphones at 70 dB SPL. A fixed step size for changes in ΔI (2 dB) was maintained by adding the increment and standard channels in quadrature. Thresholds were determined for sessions of 40, 55, 70, 85, 100, and 115 2IFC trials. Six thresholds were taken at each session size, for each of the two level-change rules. Thresholds were computed as the mean level of ΔI revisited. Sweat factors [M. M. Taylor and C. D. Creelman, J. Acoust. Soc. Am. 41, 782–787 (1967)] were calculated and averaged across the seven subjects for each of the 12 experimental conditions (session-size x rule). The 2-1 rule generated smaller sweat factors, averaged across sessions, and was thus the more efficient rule. An analysis of variance yielded the additional finding that psychophysical efficiency was independent of session size.</abstract><doi>10.1121/1.2016477</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0001-4966
ispartof The Journal of the Acoustical Society of America, 1977-12, Vol.62 (S1), p.S96-S96
issn 0001-4966
1520-8524
language eng
recordid cdi_crossref_primary_10_1121_1_2016477
source AIP Acoustical Society of America
title On the efficiency of 2IFC threshold measurement
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-08T11%3A31%3A28IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=On%20the%20efficiency%20of%202IFC%20threshold%20measurement&rft.jtitle=The%20Journal%20of%20the%20Acoustical%20Society%20of%20America&rft.au=Schacknow,%20Paul%20N.&rft.date=1977-12-01&rft.volume=62&rft.issue=S1&rft.spage=S96&rft.epage=S96&rft.pages=S96-S96&rft.issn=0001-4966&rft.eissn=1520-8524&rft_id=info:doi/10.1121/1.2016477&rft_dat=%3Ccrossref%3E10_1121_1_2016477%3C/crossref%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true