SU‐C‐224‐10: Accurate Patient Dose Reconstruction from On‐Treatment EPID Images

Purpose: This work presents an iterative algorithm that reconstructs delivered patient dose from the planning CT/CBCT and portal images obtained during treatment. This approach provides a mechanism for fully three‐dimensional in vivo patient dose verification. The strength of this dose reconstructio...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Medical Physics 2011-06, Vol.38 (6), p.3367-3367
Hauptverfasser: Van Uytven, E, McCurdy, B, Chytyk, K, Van Beek, T
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 3367
container_issue 6
container_start_page 3367
container_title Medical Physics
container_volume 38
creator Van Uytven, E
McCurdy, B
Chytyk, K
Van Beek, T
description Purpose: This work presents an iterative algorithm that reconstructs delivered patient dose from the planning CT/CBCT and portal images obtained during treatment. This approach provides a mechanism for fully three‐dimensional in vivo patient dose verification. The strength of this dose reconstruction technique is that the patient doses are reconstructed with delivered beam fluences measured during patient treatment. Methods: Using an initial estimate of fluence upstream of the patient, a prediction model is used to predict fluences at the plane of the EPID, which are then converted to dose using EPID dose deposition kernels. The predicted dose is compared to the actual measured dose and a correction to the initial fluence estimate is applied. After convergence, a convolution/superposition algorithm is then employed to determine patient dose from the converged estimate of upstream fluence. An especially unique feature of this algorithm is the general physics‐based model used to accurately predict portal dose images over a variety of treatment conditions. Results: The method is demonstrated for a seven beam IMRT step‐and‐shoot prostate cancer treatment. The results of the patient dose reconstruction were compared to the patient dose obtained from a Pinnacle treatment planning system. Gamma comparison between the two dose distributions indicates 99.2% of voxels satisfying gamma< within the PTV, and 87.9% within the CT patient volume. Conclusions: Preliminary results indicate that the patient dose reconstruction model is successful in predicting dose to the PTV region. We are working to improve agreement for lower dose regions. With further improvements, this technique may become a routine tool for in‐vivo patient dose verification. This work is funded in part by Varian Medical Systems.
doi_str_mv 10.1118/1.3611458
format Article
fullrecord <record><control><sourceid>wiley_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1118_1_3611458</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>MP1458</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1778-f3857bc2cffd84060a6333f34e7871cc558d1cfaf2f1a764b157c7634b57ad1e3</originalsourceid><addsrcrecordid>eNp90M1KAzEQB_AgCtbqwTfIVWHrTD42qbdSqxYqLdricUnTRFa6u5KkSG8-gs_ok7ilvephZi6_GZg_IZcIPUTUN9jjOaKQ-oh0mFA8Ewz6x6QD0BcZEyBPyVmM7wCQcwkd8vqy-Pn6HrbFmGg7wi0dWLsJJjk6M6l0daJ3TXT02dmmjilsbCqbmvrQVHRatyvz4Eyqdm40G9_RcWXeXDwnJ96so7s4zC5Z3I_mw8dsMn0YDweTzKJSOvNcS7W0zHq_0gJyMDnn3HPhlFZorZR6hdYbzzwalYslSmVVzsVSKrNCx7vkan_XhibG4HzxEcrKhG2BUOwSKbA4JNLabG8_y7Xb_g2Lp9nBX-99tGUyu6__Of4Lav5v6w</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>SU‐C‐224‐10: Accurate Patient Dose Reconstruction from On‐Treatment EPID Images</title><source>Wiley Online Library Journals Frontfile Complete</source><source>Alma/SFX Local Collection</source><creator>Van Uytven, E ; McCurdy, B ; Chytyk, K ; Van Beek, T</creator><creatorcontrib>Van Uytven, E ; McCurdy, B ; Chytyk, K ; Van Beek, T</creatorcontrib><description>Purpose: This work presents an iterative algorithm that reconstructs delivered patient dose from the planning CT/CBCT and portal images obtained during treatment. This approach provides a mechanism for fully three‐dimensional in vivo patient dose verification. The strength of this dose reconstruction technique is that the patient doses are reconstructed with delivered beam fluences measured during patient treatment. Methods: Using an initial estimate of fluence upstream of the patient, a prediction model is used to predict fluences at the plane of the EPID, which are then converted to dose using EPID dose deposition kernels. The predicted dose is compared to the actual measured dose and a correction to the initial fluence estimate is applied. After convergence, a convolution/superposition algorithm is then employed to determine patient dose from the converged estimate of upstream fluence. An especially unique feature of this algorithm is the general physics‐based model used to accurately predict portal dose images over a variety of treatment conditions. Results: The method is demonstrated for a seven beam IMRT step‐and‐shoot prostate cancer treatment. The results of the patient dose reconstruction were compared to the patient dose obtained from a Pinnacle treatment planning system. Gamma comparison between the two dose distributions indicates 99.2% of voxels satisfying gamma&lt; within the PTV, and 87.9% within the CT patient volume. Conclusions: Preliminary results indicate that the patient dose reconstruction model is successful in predicting dose to the PTV region. We are working to improve agreement for lower dose regions. With further improvements, this technique may become a routine tool for in‐vivo patient dose verification. This work is funded in part by Varian Medical Systems.</description><identifier>ISSN: 0094-2405</identifier><identifier>EISSN: 2473-4209</identifier><identifier>DOI: 10.1118/1.3611458</identifier><identifier>CODEN: MPHYA6</identifier><language>eng</language><publisher>American Association of Physicists in Medicine</publisher><subject>Biomedical modeling ; Cancer ; Computed tomography ; Cone beam computed tomography ; Image guided radiation therapy ; Intensity modulated radiation therapy ; Medical image reconstruction ; Medical imaging ; Medical treatment planning ; Therapeutics</subject><ispartof>Medical Physics, 2011-06, Vol.38 (6), p.3367-3367</ispartof><rights>American Association of Physicists in Medicine</rights><rights>2011 American Association of Physicists in Medicine</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1118%2F1.3611458$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>309,310,314,780,784,789,790,1417,23930,23931,25140,27924,27925,45575</link.rule.ids></links><search><creatorcontrib>Van Uytven, E</creatorcontrib><creatorcontrib>McCurdy, B</creatorcontrib><creatorcontrib>Chytyk, K</creatorcontrib><creatorcontrib>Van Beek, T</creatorcontrib><title>SU‐C‐224‐10: Accurate Patient Dose Reconstruction from On‐Treatment EPID Images</title><title>Medical Physics</title><description>Purpose: This work presents an iterative algorithm that reconstructs delivered patient dose from the planning CT/CBCT and portal images obtained during treatment. This approach provides a mechanism for fully three‐dimensional in vivo patient dose verification. The strength of this dose reconstruction technique is that the patient doses are reconstructed with delivered beam fluences measured during patient treatment. Methods: Using an initial estimate of fluence upstream of the patient, a prediction model is used to predict fluences at the plane of the EPID, which are then converted to dose using EPID dose deposition kernels. The predicted dose is compared to the actual measured dose and a correction to the initial fluence estimate is applied. After convergence, a convolution/superposition algorithm is then employed to determine patient dose from the converged estimate of upstream fluence. An especially unique feature of this algorithm is the general physics‐based model used to accurately predict portal dose images over a variety of treatment conditions. Results: The method is demonstrated for a seven beam IMRT step‐and‐shoot prostate cancer treatment. The results of the patient dose reconstruction were compared to the patient dose obtained from a Pinnacle treatment planning system. Gamma comparison between the two dose distributions indicates 99.2% of voxels satisfying gamma&lt; within the PTV, and 87.9% within the CT patient volume. Conclusions: Preliminary results indicate that the patient dose reconstruction model is successful in predicting dose to the PTV region. We are working to improve agreement for lower dose regions. With further improvements, this technique may become a routine tool for in‐vivo patient dose verification. This work is funded in part by Varian Medical Systems.</description><subject>Biomedical modeling</subject><subject>Cancer</subject><subject>Computed tomography</subject><subject>Cone beam computed tomography</subject><subject>Image guided radiation therapy</subject><subject>Intensity modulated radiation therapy</subject><subject>Medical image reconstruction</subject><subject>Medical imaging</subject><subject>Medical treatment planning</subject><subject>Therapeutics</subject><issn>0094-2405</issn><issn>2473-4209</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><recordid>eNp90M1KAzEQB_AgCtbqwTfIVWHrTD42qbdSqxYqLdricUnTRFa6u5KkSG8-gs_ok7ilvephZi6_GZg_IZcIPUTUN9jjOaKQ-oh0mFA8Ewz6x6QD0BcZEyBPyVmM7wCQcwkd8vqy-Pn6HrbFmGg7wi0dWLsJJjk6M6l0daJ3TXT02dmmjilsbCqbmvrQVHRatyvz4Eyqdm40G9_RcWXeXDwnJ96so7s4zC5Z3I_mw8dsMn0YDweTzKJSOvNcS7W0zHq_0gJyMDnn3HPhlFZorZR6hdYbzzwalYslSmVVzsVSKrNCx7vkan_XhibG4HzxEcrKhG2BUOwSKbA4JNLabG8_y7Xb_g2Lp9nBX-99tGUyu6__Of4Lav5v6w</recordid><startdate>201106</startdate><enddate>201106</enddate><creator>Van Uytven, E</creator><creator>McCurdy, B</creator><creator>Chytyk, K</creator><creator>Van Beek, T</creator><general>American Association of Physicists in Medicine</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>201106</creationdate><title>SU‐C‐224‐10: Accurate Patient Dose Reconstruction from On‐Treatment EPID Images</title><author>Van Uytven, E ; McCurdy, B ; Chytyk, K ; Van Beek, T</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1778-f3857bc2cffd84060a6333f34e7871cc558d1cfaf2f1a764b157c7634b57ad1e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Biomedical modeling</topic><topic>Cancer</topic><topic>Computed tomography</topic><topic>Cone beam computed tomography</topic><topic>Image guided radiation therapy</topic><topic>Intensity modulated radiation therapy</topic><topic>Medical image reconstruction</topic><topic>Medical imaging</topic><topic>Medical treatment planning</topic><topic>Therapeutics</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Van Uytven, E</creatorcontrib><creatorcontrib>McCurdy, B</creatorcontrib><creatorcontrib>Chytyk, K</creatorcontrib><creatorcontrib>Van Beek, T</creatorcontrib><collection>CrossRef</collection><jtitle>Medical Physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Van Uytven, E</au><au>McCurdy, B</au><au>Chytyk, K</au><au>Van Beek, T</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>SU‐C‐224‐10: Accurate Patient Dose Reconstruction from On‐Treatment EPID Images</atitle><jtitle>Medical Physics</jtitle><date>2011-06</date><risdate>2011</risdate><volume>38</volume><issue>6</issue><spage>3367</spage><epage>3367</epage><pages>3367-3367</pages><issn>0094-2405</issn><eissn>2473-4209</eissn><coden>MPHYA6</coden><abstract>Purpose: This work presents an iterative algorithm that reconstructs delivered patient dose from the planning CT/CBCT and portal images obtained during treatment. This approach provides a mechanism for fully three‐dimensional in vivo patient dose verification. The strength of this dose reconstruction technique is that the patient doses are reconstructed with delivered beam fluences measured during patient treatment. Methods: Using an initial estimate of fluence upstream of the patient, a prediction model is used to predict fluences at the plane of the EPID, which are then converted to dose using EPID dose deposition kernels. The predicted dose is compared to the actual measured dose and a correction to the initial fluence estimate is applied. After convergence, a convolution/superposition algorithm is then employed to determine patient dose from the converged estimate of upstream fluence. An especially unique feature of this algorithm is the general physics‐based model used to accurately predict portal dose images over a variety of treatment conditions. Results: The method is demonstrated for a seven beam IMRT step‐and‐shoot prostate cancer treatment. The results of the patient dose reconstruction were compared to the patient dose obtained from a Pinnacle treatment planning system. Gamma comparison between the two dose distributions indicates 99.2% of voxels satisfying gamma&lt; within the PTV, and 87.9% within the CT patient volume. Conclusions: Preliminary results indicate that the patient dose reconstruction model is successful in predicting dose to the PTV region. We are working to improve agreement for lower dose regions. With further improvements, this technique may become a routine tool for in‐vivo patient dose verification. This work is funded in part by Varian Medical Systems.</abstract><pub>American Association of Physicists in Medicine</pub><doi>10.1118/1.3611458</doi><tpages>1</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0094-2405
ispartof Medical Physics, 2011-06, Vol.38 (6), p.3367-3367
issn 0094-2405
2473-4209
language eng
recordid cdi_crossref_primary_10_1118_1_3611458
source Wiley Online Library Journals Frontfile Complete; Alma/SFX Local Collection
subjects Biomedical modeling
Cancer
Computed tomography
Cone beam computed tomography
Image guided radiation therapy
Intensity modulated radiation therapy
Medical image reconstruction
Medical imaging
Medical treatment planning
Therapeutics
title SU‐C‐224‐10: Accurate Patient Dose Reconstruction from On‐Treatment EPID Images
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T03%3A13%3A25IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wiley_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=SU%E2%80%90C%E2%80%90224%E2%80%9010:%20Accurate%20Patient%20Dose%20Reconstruction%20from%20On%E2%80%90Treatment%20EPID%20Images&rft.jtitle=Medical%20Physics&rft.au=Van%20Uytven,%20E&rft.date=2011-06&rft.volume=38&rft.issue=6&rft.spage=3367&rft.epage=3367&rft.pages=3367-3367&rft.issn=0094-2405&rft.eissn=2473-4209&rft.coden=MPHYA6&rft_id=info:doi/10.1118/1.3611458&rft_dat=%3Cwiley_cross%3EMP1458%3C/wiley_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true