SU‐FF‐T‐314: Multi‐Leaf Collimator Quality Assurance Using Pulse Width Modulation Analysis

Purpose: To develop a quality assurance (QA) methodology for prospective mechanical maintenance of multi‐leaf collimator (MLC) leaf positioning motors. Method and Materials: Pulse width modulation (PWM) analysis was used to assess the current performance status of the MLC leaf positioning motors for...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Medical physics (Lancaster) 2007-06, Vol.34 (6), p.2474-2474
Hauptverfasser: Shoales, J, Boyer, A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2474
container_issue 6
container_start_page 2474
container_title Medical physics (Lancaster)
container_volume 34
creator Shoales, J
Boyer, A
description Purpose: To develop a quality assurance (QA) methodology for prospective mechanical maintenance of multi‐leaf collimator (MLC) leaf positioning motors. Method and Materials: Pulse width modulation (PWM) analysis was used to assess the current performance status of the MLC leaf positioning motors for three medical linear accelerators in our clinic. PWM is a software diagnostic tool available as a built‐in component of the linear accelerator MLC controller computer interface (Varian Medical Systems, Inc. Palo Alto, CA). PWM probes the operational status of each MLC leaf motor by sending direct current (DC) pulses directly to the motor windings until each motor drives its individual leaf 2.0[mm] beyond four initial set positions. The DC pulse widths are incrementally increased by 2[ms] from an initial duration of 2[ms] to the length required for 2.0[mm] of MLC leaf displacement beyond the four set positions. The PWM values are stored for each position. Statistical process control (SPC) principles were applied to the data to establish process behavior characteristics. SPC limits were then applied to the PWM data and individual leaf performance statuses were analyzed. Our accelerator engineer serviced the MLC motors performing outside of the PWM SPC limits. The PWM analyses were repeated and compared with the previous results. Results: The established SPC limits for PWM average and range were 10[ms] and 3[ms], respectively. Two MLC motors (corresponding to MLC leaves 25 and 26) on carriage bank B were performing well beyond the calculated SPC limits. The corresponding motors were investigated and found to have broken motor drive hardware. The motors in question performed within SPC limits after reanalysis. Conclusion: PWM analysis for MLC mechanical QA required less than 5 minutes for data acquisition and was highly effective in diagnosing an MLC mechanical malfunction as part of a routine monthly QA procedure.
doi_str_mv 10.1118/1.2760976
format Article
fullrecord <record><control><sourceid>wiley_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1118_1_2760976</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>MP0976</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1776-c1e0f75285f4a796b47c6c6804d86458e777bd64e6536f36ab7b059cf59d62533</originalsourceid><addsrcrecordid>eNp9kM1Kw0AUhQdRsFYXvsFsFVLvZP4Sd6VYFVqs2OIyTCYzOjImkkmQ7HwEn9EncbTd6uKey4WPwz0HoVMCE0JIdkEmqRSQS7GHRimTNGEp5PtoBJCzJGXAD9FRCC8AICiHESofNl8fn_N5lHUcStglXva-c_FYGGXxrPHevaquafF9r7zrBjwNoW9VrQ3eBFc_4VXvg8GPruqe8bKpeq8619R4Wis_BBeO0YFVkTjZ7THazK_Ws5tkcXd9O5suEk2kFFENWMnTjFumZC5KJrXQIgNWZYLxzEgpy0owIzgVlgpVyhJ4ri3PK5FySsfobOur2yaE1tjirY2ft0NBoPgppyDFrpzIJlv23Xkz_A0Wy9WOP9_yQbvuN94_5t_mLHQ-</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>SU‐FF‐T‐314: Multi‐Leaf Collimator Quality Assurance Using Pulse Width Modulation Analysis</title><source>Wiley Online Library Journals Frontfile Complete</source><creator>Shoales, J ; Boyer, A</creator><creatorcontrib>Shoales, J ; Boyer, A</creatorcontrib><description>Purpose: To develop a quality assurance (QA) methodology for prospective mechanical maintenance of multi‐leaf collimator (MLC) leaf positioning motors. Method and Materials: Pulse width modulation (PWM) analysis was used to assess the current performance status of the MLC leaf positioning motors for three medical linear accelerators in our clinic. PWM is a software diagnostic tool available as a built‐in component of the linear accelerator MLC controller computer interface (Varian Medical Systems, Inc. Palo Alto, CA). PWM probes the operational status of each MLC leaf motor by sending direct current (DC) pulses directly to the motor windings until each motor drives its individual leaf 2.0[mm] beyond four initial set positions. The DC pulse widths are incrementally increased by 2[ms] from an initial duration of 2[ms] to the length required for 2.0[mm] of MLC leaf displacement beyond the four set positions. The PWM values are stored for each position. Statistical process control (SPC) principles were applied to the data to establish process behavior characteristics. SPC limits were then applied to the PWM data and individual leaf performance statuses were analyzed. Our accelerator engineer serviced the MLC motors performing outside of the PWM SPC limits. The PWM analyses were repeated and compared with the previous results. Results: The established SPC limits for PWM average and range were 10[ms] and 3[ms], respectively. Two MLC motors (corresponding to MLC leaves 25 and 26) on carriage bank B were performing well beyond the calculated SPC limits. The corresponding motors were investigated and found to have broken motor drive hardware. The motors in question performed within SPC limits after reanalysis. Conclusion: PWM analysis for MLC mechanical QA required less than 5 minutes for data acquisition and was highly effective in diagnosing an MLC mechanical malfunction as part of a routine monthly QA procedure.</description><identifier>ISSN: 0094-2405</identifier><identifier>EISSN: 2473-4209</identifier><identifier>DOI: 10.1118/1.2760976</identifier><identifier>CODEN: MPHYA6</identifier><language>eng</language><publisher>American Association of Physicists in Medicine</publisher><subject>Collimators ; Computer interfaces ; Computer software ; Data analysis ; Linear accelerators ; Materials analysis ; Medical accelerators ; Medical diagnosis ; Multileaf collimators ; Quality assurance</subject><ispartof>Medical physics (Lancaster), 2007-06, Vol.34 (6), p.2474-2474</ispartof><rights>American Association of Physicists in Medicine</rights><rights>2007 American Association of Physicists in Medicine</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1118%2F1.2760976$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,776,780,1411,27901,27902,45551</link.rule.ids></links><search><creatorcontrib>Shoales, J</creatorcontrib><creatorcontrib>Boyer, A</creatorcontrib><title>SU‐FF‐T‐314: Multi‐Leaf Collimator Quality Assurance Using Pulse Width Modulation Analysis</title><title>Medical physics (Lancaster)</title><description>Purpose: To develop a quality assurance (QA) methodology for prospective mechanical maintenance of multi‐leaf collimator (MLC) leaf positioning motors. Method and Materials: Pulse width modulation (PWM) analysis was used to assess the current performance status of the MLC leaf positioning motors for three medical linear accelerators in our clinic. PWM is a software diagnostic tool available as a built‐in component of the linear accelerator MLC controller computer interface (Varian Medical Systems, Inc. Palo Alto, CA). PWM probes the operational status of each MLC leaf motor by sending direct current (DC) pulses directly to the motor windings until each motor drives its individual leaf 2.0[mm] beyond four initial set positions. The DC pulse widths are incrementally increased by 2[ms] from an initial duration of 2[ms] to the length required for 2.0[mm] of MLC leaf displacement beyond the four set positions. The PWM values are stored for each position. Statistical process control (SPC) principles were applied to the data to establish process behavior characteristics. SPC limits were then applied to the PWM data and individual leaf performance statuses were analyzed. Our accelerator engineer serviced the MLC motors performing outside of the PWM SPC limits. The PWM analyses were repeated and compared with the previous results. Results: The established SPC limits for PWM average and range were 10[ms] and 3[ms], respectively. Two MLC motors (corresponding to MLC leaves 25 and 26) on carriage bank B were performing well beyond the calculated SPC limits. The corresponding motors were investigated and found to have broken motor drive hardware. The motors in question performed within SPC limits after reanalysis. Conclusion: PWM analysis for MLC mechanical QA required less than 5 minutes for data acquisition and was highly effective in diagnosing an MLC mechanical malfunction as part of a routine monthly QA procedure.</description><subject>Collimators</subject><subject>Computer interfaces</subject><subject>Computer software</subject><subject>Data analysis</subject><subject>Linear accelerators</subject><subject>Materials analysis</subject><subject>Medical accelerators</subject><subject>Medical diagnosis</subject><subject>Multileaf collimators</subject><subject>Quality assurance</subject><issn>0094-2405</issn><issn>2473-4209</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><recordid>eNp9kM1Kw0AUhQdRsFYXvsFsFVLvZP4Sd6VYFVqs2OIyTCYzOjImkkmQ7HwEn9EncbTd6uKey4WPwz0HoVMCE0JIdkEmqRSQS7GHRimTNGEp5PtoBJCzJGXAD9FRCC8AICiHESofNl8fn_N5lHUcStglXva-c_FYGGXxrPHevaquafF9r7zrBjwNoW9VrQ3eBFc_4VXvg8GPruqe8bKpeq8619R4Wis_BBeO0YFVkTjZ7THazK_Ws5tkcXd9O5suEk2kFFENWMnTjFumZC5KJrXQIgNWZYLxzEgpy0owIzgVlgpVyhJ4ri3PK5FySsfobOur2yaE1tjirY2ft0NBoPgppyDFrpzIJlv23Xkz_A0Wy9WOP9_yQbvuN94_5t_mLHQ-</recordid><startdate>200706</startdate><enddate>200706</enddate><creator>Shoales, J</creator><creator>Boyer, A</creator><general>American Association of Physicists in Medicine</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>200706</creationdate><title>SU‐FF‐T‐314: Multi‐Leaf Collimator Quality Assurance Using Pulse Width Modulation Analysis</title><author>Shoales, J ; Boyer, A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1776-c1e0f75285f4a796b47c6c6804d86458e777bd64e6536f36ab7b059cf59d62533</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Collimators</topic><topic>Computer interfaces</topic><topic>Computer software</topic><topic>Data analysis</topic><topic>Linear accelerators</topic><topic>Materials analysis</topic><topic>Medical accelerators</topic><topic>Medical diagnosis</topic><topic>Multileaf collimators</topic><topic>Quality assurance</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Shoales, J</creatorcontrib><creatorcontrib>Boyer, A</creatorcontrib><collection>CrossRef</collection><jtitle>Medical physics (Lancaster)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Shoales, J</au><au>Boyer, A</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>SU‐FF‐T‐314: Multi‐Leaf Collimator Quality Assurance Using Pulse Width Modulation Analysis</atitle><jtitle>Medical physics (Lancaster)</jtitle><date>2007-06</date><risdate>2007</risdate><volume>34</volume><issue>6</issue><spage>2474</spage><epage>2474</epage><pages>2474-2474</pages><issn>0094-2405</issn><eissn>2473-4209</eissn><coden>MPHYA6</coden><abstract>Purpose: To develop a quality assurance (QA) methodology for prospective mechanical maintenance of multi‐leaf collimator (MLC) leaf positioning motors. Method and Materials: Pulse width modulation (PWM) analysis was used to assess the current performance status of the MLC leaf positioning motors for three medical linear accelerators in our clinic. PWM is a software diagnostic tool available as a built‐in component of the linear accelerator MLC controller computer interface (Varian Medical Systems, Inc. Palo Alto, CA). PWM probes the operational status of each MLC leaf motor by sending direct current (DC) pulses directly to the motor windings until each motor drives its individual leaf 2.0[mm] beyond four initial set positions. The DC pulse widths are incrementally increased by 2[ms] from an initial duration of 2[ms] to the length required for 2.0[mm] of MLC leaf displacement beyond the four set positions. The PWM values are stored for each position. Statistical process control (SPC) principles were applied to the data to establish process behavior characteristics. SPC limits were then applied to the PWM data and individual leaf performance statuses were analyzed. Our accelerator engineer serviced the MLC motors performing outside of the PWM SPC limits. The PWM analyses were repeated and compared with the previous results. Results: The established SPC limits for PWM average and range were 10[ms] and 3[ms], respectively. Two MLC motors (corresponding to MLC leaves 25 and 26) on carriage bank B were performing well beyond the calculated SPC limits. The corresponding motors were investigated and found to have broken motor drive hardware. The motors in question performed within SPC limits after reanalysis. Conclusion: PWM analysis for MLC mechanical QA required less than 5 minutes for data acquisition and was highly effective in diagnosing an MLC mechanical malfunction as part of a routine monthly QA procedure.</abstract><pub>American Association of Physicists in Medicine</pub><doi>10.1118/1.2760976</doi><tpages>1</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0094-2405
ispartof Medical physics (Lancaster), 2007-06, Vol.34 (6), p.2474-2474
issn 0094-2405
2473-4209
language eng
recordid cdi_crossref_primary_10_1118_1_2760976
source Wiley Online Library Journals Frontfile Complete
subjects Collimators
Computer interfaces
Computer software
Data analysis
Linear accelerators
Materials analysis
Medical accelerators
Medical diagnosis
Multileaf collimators
Quality assurance
title SU‐FF‐T‐314: Multi‐Leaf Collimator Quality Assurance Using Pulse Width Modulation Analysis
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-01T04%3A57%3A06IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wiley_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=SU%E2%80%90FF%E2%80%90T%E2%80%90314:%20Multi%E2%80%90Leaf%20Collimator%20Quality%20Assurance%20Using%20Pulse%20Width%20Modulation%20Analysis&rft.jtitle=Medical%20physics%20(Lancaster)&rft.au=Shoales,%20J&rft.date=2007-06&rft.volume=34&rft.issue=6&rft.spage=2474&rft.epage=2474&rft.pages=2474-2474&rft.issn=0094-2405&rft.eissn=2473-4209&rft.coden=MPHYA6&rft_id=info:doi/10.1118/1.2760976&rft_dat=%3Cwiley_cross%3EMP0976%3C/wiley_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true