A Preliminary Investigation Into the Feasibility of Semi-Autonomous Surgical Path Planning for a Mastoidectomy Using LSTM-Recurrent Neural Networks

Path planning algorithms for robotics can be as simple as having an operator program waypoints into a robot's controller and having the robot perform a simple task such as welding. This works well in an industrial setting but will not work for complicated tasks such as performing surgery. Anoth...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of medical devices 2021-03, Vol.15 (1)
Hauptverfasser: Korte, Christopher, Schaffner, Grant, McGhan, Catharine L. R
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 1
container_start_page
container_title Journal of medical devices
container_volume 15
creator Korte, Christopher
Schaffner, Grant
McGhan, Catharine L. R
description Path planning algorithms for robotics can be as simple as having an operator program waypoints into a robot's controller and having the robot perform a simple task such as welding. This works well in an industrial setting but will not work for complicated tasks such as performing surgery. Another approach would be to use a constraint function in programing a robot to perform surgery, but it would be difficult to capture and represent all of the surgeon's information in the mathematical terms required for a cost function. A third approach, and the one utilized in this study, is to train a set of artificial neural networks (ANNs) using recorded surgeons' motions when manipulating a surgical instrument during procedure training using a surgery simulator. This has the advantage of indirectly capturing the surgeon's abilities and intentions without needing to explicitly capture all of the motion information that must be encoded from their trajectory planning and decision-making, and then, say, creating a complex constraint function using that information. In this research effort, virtually captured surgical trajectories from trained surgeons were used to train ANNs, after being preprocessed into three subtasks. Each set of subtask data was used to train a separate ANN. Each of the ANNs was trained using a custom cost function and evaluated using custom metrics. During the training, the positions of fiducial markers, recorded during procedure attempts, were used to orient the recorded path relative to the patient's anatomy. Although the ANN-generated trajectories were not used to perform surgery on a live patient in this study, the fiducial marker position information is intended to be exploited during a real procedure to position, orient, and scale a tool trajectory to suit a patient's specific anatomy. The trained ANNs were subjected to several tests to assess their safety and robustness. We found that even when trained on a small number of datasets, the ANNs converged and could generate output trajectories that were still assessed to be safe even when slight changes in the fiducial marker placement locations were given.
doi_str_mv 10.1115/1.4049559
format Article
fullrecord <record><control><sourceid>asme_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1115_1_4049559</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1094079</sourcerecordid><originalsourceid>FETCH-LOGICAL-a210t-c919273591885c6320f64b942175dcaeb1aa9efb934167bc05636340eafa1e623</originalsourceid><addsrcrecordid>eNo9kMFOAjEQhhujiYgevHvo1cNiZ7tb6JEQURJAIpB423SXWSjutqbtangOX9glEE8zk_-byeQj5B5YDwDSJ-glLJFpKi9IBySPIwHy4_K_H8A1ufF-z1jKeSw65HdIFw4rXWuj3IFOzDf6oLcqaGvaKVgadkjHqLzOdaXDgdqSLrHW0bAJ1tjaNp4uG7fVharoQoUdXVTKGG22tLSOKjpTPli9wSLY-kDX_phMl6tZ9I5F4xyaQOfYuHZ7juHHuk9_S65KVXm8O9cuWY-fV6PXaPr2MhkNp5GKgYWokCDjPk8lDAZpIXjMSpHkMomhn24KhTkoJbHMJU9A9POCpYILnjBUpQIUMe-Sx9PdwlnvHZbZl9N1qyEDlh1tZpCdbbbsw4lVvsZsbxtn2tdaUCasL_kfJ4lyXg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>A Preliminary Investigation Into the Feasibility of Semi-Autonomous Surgical Path Planning for a Mastoidectomy Using LSTM-Recurrent Neural Networks</title><source>ASME Transactions Journals (Current)</source><source>Alma/SFX Local Collection</source><creator>Korte, Christopher ; Schaffner, Grant ; McGhan, Catharine L. R</creator><creatorcontrib>Korte, Christopher ; Schaffner, Grant ; McGhan, Catharine L. R</creatorcontrib><description>Path planning algorithms for robotics can be as simple as having an operator program waypoints into a robot's controller and having the robot perform a simple task such as welding. This works well in an industrial setting but will not work for complicated tasks such as performing surgery. Another approach would be to use a constraint function in programing a robot to perform surgery, but it would be difficult to capture and represent all of the surgeon's information in the mathematical terms required for a cost function. A third approach, and the one utilized in this study, is to train a set of artificial neural networks (ANNs) using recorded surgeons' motions when manipulating a surgical instrument during procedure training using a surgery simulator. This has the advantage of indirectly capturing the surgeon's abilities and intentions without needing to explicitly capture all of the motion information that must be encoded from their trajectory planning and decision-making, and then, say, creating a complex constraint function using that information. In this research effort, virtually captured surgical trajectories from trained surgeons were used to train ANNs, after being preprocessed into three subtasks. Each set of subtask data was used to train a separate ANN. Each of the ANNs was trained using a custom cost function and evaluated using custom metrics. During the training, the positions of fiducial markers, recorded during procedure attempts, were used to orient the recorded path relative to the patient's anatomy. Although the ANN-generated trajectories were not used to perform surgery on a live patient in this study, the fiducial marker position information is intended to be exploited during a real procedure to position, orient, and scale a tool trajectory to suit a patient's specific anatomy. The trained ANNs were subjected to several tests to assess their safety and robustness. We found that even when trained on a small number of datasets, the ANNs converged and could generate output trajectories that were still assessed to be safe even when slight changes in the fiducial marker placement locations were given.</description><identifier>ISSN: 1932-6181</identifier><identifier>EISSN: 1932-619X</identifier><identifier>DOI: 10.1115/1.4049559</identifier><language>eng</language><publisher>ASME</publisher><ispartof>Journal of medical devices, 2021-03, Vol.15 (1)</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-a210t-c919273591885c6320f64b942175dcaeb1aa9efb934167bc05636340eafa1e623</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904,38499</link.rule.ids></links><search><creatorcontrib>Korte, Christopher</creatorcontrib><creatorcontrib>Schaffner, Grant</creatorcontrib><creatorcontrib>McGhan, Catharine L. R</creatorcontrib><title>A Preliminary Investigation Into the Feasibility of Semi-Autonomous Surgical Path Planning for a Mastoidectomy Using LSTM-Recurrent Neural Networks</title><title>Journal of medical devices</title><addtitle>J. Med. Devices</addtitle><description>Path planning algorithms for robotics can be as simple as having an operator program waypoints into a robot's controller and having the robot perform a simple task such as welding. This works well in an industrial setting but will not work for complicated tasks such as performing surgery. Another approach would be to use a constraint function in programing a robot to perform surgery, but it would be difficult to capture and represent all of the surgeon's information in the mathematical terms required for a cost function. A third approach, and the one utilized in this study, is to train a set of artificial neural networks (ANNs) using recorded surgeons' motions when manipulating a surgical instrument during procedure training using a surgery simulator. This has the advantage of indirectly capturing the surgeon's abilities and intentions without needing to explicitly capture all of the motion information that must be encoded from their trajectory planning and decision-making, and then, say, creating a complex constraint function using that information. In this research effort, virtually captured surgical trajectories from trained surgeons were used to train ANNs, after being preprocessed into three subtasks. Each set of subtask data was used to train a separate ANN. Each of the ANNs was trained using a custom cost function and evaluated using custom metrics. During the training, the positions of fiducial markers, recorded during procedure attempts, were used to orient the recorded path relative to the patient's anatomy. Although the ANN-generated trajectories were not used to perform surgery on a live patient in this study, the fiducial marker position information is intended to be exploited during a real procedure to position, orient, and scale a tool trajectory to suit a patient's specific anatomy. The trained ANNs were subjected to several tests to assess their safety and robustness. We found that even when trained on a small number of datasets, the ANNs converged and could generate output trajectories that were still assessed to be safe even when slight changes in the fiducial marker placement locations were given.</description><issn>1932-6181</issn><issn>1932-619X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNo9kMFOAjEQhhujiYgevHvo1cNiZ7tb6JEQURJAIpB423SXWSjutqbtangOX9glEE8zk_-byeQj5B5YDwDSJ-glLJFpKi9IBySPIwHy4_K_H8A1ufF-z1jKeSw65HdIFw4rXWuj3IFOzDf6oLcqaGvaKVgadkjHqLzOdaXDgdqSLrHW0bAJ1tjaNp4uG7fVharoQoUdXVTKGG22tLSOKjpTPli9wSLY-kDX_phMl6tZ9I5F4xyaQOfYuHZ7juHHuk9_S65KVXm8O9cuWY-fV6PXaPr2MhkNp5GKgYWokCDjPk8lDAZpIXjMSpHkMomhn24KhTkoJbHMJU9A9POCpYILnjBUpQIUMe-Sx9PdwlnvHZbZl9N1qyEDlh1tZpCdbbbsw4lVvsZsbxtn2tdaUCasL_kfJ4lyXg</recordid><startdate>20210301</startdate><enddate>20210301</enddate><creator>Korte, Christopher</creator><creator>Schaffner, Grant</creator><creator>McGhan, Catharine L. R</creator><general>ASME</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20210301</creationdate><title>A Preliminary Investigation Into the Feasibility of Semi-Autonomous Surgical Path Planning for a Mastoidectomy Using LSTM-Recurrent Neural Networks</title><author>Korte, Christopher ; Schaffner, Grant ; McGhan, Catharine L. R</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a210t-c919273591885c6320f64b942175dcaeb1aa9efb934167bc05636340eafa1e623</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Korte, Christopher</creatorcontrib><creatorcontrib>Schaffner, Grant</creatorcontrib><creatorcontrib>McGhan, Catharine L. R</creatorcontrib><collection>CrossRef</collection><jtitle>Journal of medical devices</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Korte, Christopher</au><au>Schaffner, Grant</au><au>McGhan, Catharine L. R</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Preliminary Investigation Into the Feasibility of Semi-Autonomous Surgical Path Planning for a Mastoidectomy Using LSTM-Recurrent Neural Networks</atitle><jtitle>Journal of medical devices</jtitle><stitle>J. Med. Devices</stitle><date>2021-03-01</date><risdate>2021</risdate><volume>15</volume><issue>1</issue><issn>1932-6181</issn><eissn>1932-619X</eissn><abstract>Path planning algorithms for robotics can be as simple as having an operator program waypoints into a robot's controller and having the robot perform a simple task such as welding. This works well in an industrial setting but will not work for complicated tasks such as performing surgery. Another approach would be to use a constraint function in programing a robot to perform surgery, but it would be difficult to capture and represent all of the surgeon's information in the mathematical terms required for a cost function. A third approach, and the one utilized in this study, is to train a set of artificial neural networks (ANNs) using recorded surgeons' motions when manipulating a surgical instrument during procedure training using a surgery simulator. This has the advantage of indirectly capturing the surgeon's abilities and intentions without needing to explicitly capture all of the motion information that must be encoded from their trajectory planning and decision-making, and then, say, creating a complex constraint function using that information. In this research effort, virtually captured surgical trajectories from trained surgeons were used to train ANNs, after being preprocessed into three subtasks. Each set of subtask data was used to train a separate ANN. Each of the ANNs was trained using a custom cost function and evaluated using custom metrics. During the training, the positions of fiducial markers, recorded during procedure attempts, were used to orient the recorded path relative to the patient's anatomy. Although the ANN-generated trajectories were not used to perform surgery on a live patient in this study, the fiducial marker position information is intended to be exploited during a real procedure to position, orient, and scale a tool trajectory to suit a patient's specific anatomy. The trained ANNs were subjected to several tests to assess their safety and robustness. We found that even when trained on a small number of datasets, the ANNs converged and could generate output trajectories that were still assessed to be safe even when slight changes in the fiducial marker placement locations were given.</abstract><pub>ASME</pub><doi>10.1115/1.4049559</doi></addata></record>
fulltext fulltext
identifier ISSN: 1932-6181
ispartof Journal of medical devices, 2021-03, Vol.15 (1)
issn 1932-6181
1932-619X
language eng
recordid cdi_crossref_primary_10_1115_1_4049559
source ASME Transactions Journals (Current); Alma/SFX Local Collection
title A Preliminary Investigation Into the Feasibility of Semi-Autonomous Surgical Path Planning for a Mastoidectomy Using LSTM-Recurrent Neural Networks
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-22T20%3A58%3A06IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-asme_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Preliminary%20Investigation%20Into%20the%20Feasibility%20of%20Semi-Autonomous%20Surgical%20Path%20Planning%20for%20a%20Mastoidectomy%20Using%20LSTM-Recurrent%20Neural%20Networks&rft.jtitle=Journal%20of%20medical%20devices&rft.au=Korte,%20Christopher&rft.date=2021-03-01&rft.volume=15&rft.issue=1&rft.issn=1932-6181&rft.eissn=1932-619X&rft_id=info:doi/10.1115/1.4049559&rft_dat=%3Casme_cross%3E1094079%3C/asme_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true