PV Inverter Based Fair Power Quality Control

Low voltage distribution networks incorporating solar photovoltaic (PV) panels experience overvoltage and voltage unbalance during periods of low load and high PV generation. Resolving overvoltage by active power curtailment (APC) is an effective and cost-efficient solution. However, current APC tec...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on smart grid 2023-09, Vol.14 (5), p.1-1
Hauptverfasser: Vadavathi, A.R., Hoogsteen, G., Hurink, J.L.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1
container_issue 5
container_start_page 1
container_title IEEE transactions on smart grid
container_volume 14
creator Vadavathi, A.R.
Hoogsteen, G.
Hurink, J.L.
description Low voltage distribution networks incorporating solar photovoltaic (PV) panels experience overvoltage and voltage unbalance during periods of low load and high PV generation. Resolving overvoltage by active power curtailment (APC) is an effective and cost-efficient solution. However, current APC techniques result in excessive and unfair power curtailment for prosumers at the sensitive parts of the grid that might induce neutral current. In this work, an analytical approach for fair APC and Reactive Power Control is presented for voltage regulation along with neutral current compensation. The desired power quality is maintained by controlling each phase of the PV inverter independently. The proposed algorithm regulates the voltage at the point of common coupling (PCC) within grid limits, eliminates neutral current, and reduces the grid unbalance. Furthermore, the results demonstrate that reducing the neutral current reduces the voltage at the PCC and consequently decreases the power curtailment required for overvoltage regulation.
doi_str_mv 10.1109/TSG.2023.3244601
format Article
fullrecord <record><control><sourceid>proquest_RIE</sourceid><recordid>TN_cdi_crossref_primary_10_1109_TSG_2023_3244601</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>10044253</ieee_id><sourcerecordid>2855722731</sourcerecordid><originalsourceid>FETCH-LOGICAL-c292t-8bbeac63a9d87cb4406392d39bd4e7349ae7042497a73ab9ac32d810adb56ff33</originalsourceid><addsrcrecordid>eNpNkNFLwzAQh4MoOObeffCh4KutyV2aNI9a3BwMnDh9DWmbQkdtZ9Ip--_N6BDv5Y7j-93BR8g1owljVN1v3hYJUMAEgXNB2RmZMMVVjFSw8785xUsy835LQyGiADUhd-uPaNl9WzdYFz0ab6tobhoXrfufsHjdm7YZDlHed4Pr2ytyUZvW29mpT8n7_GmTP8erl8Uyf1jFJSgY4qworCkFGlVlsiw4pwIVVKiKiluJXBkrKQeupJFoCmVKhCpj1FRFKuoacUpux7s713_trR_0tt-7LrzUkKWpBJDIAkVHqnS9987WeueaT-MOmlF91KKDFn3Uok9aQuRmjDTW2n845RxSxF9Yclve</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2855722731</pqid></control><display><type>article</type><title>PV Inverter Based Fair Power Quality Control</title><source>IEEE Electronic Library (IEL)</source><creator>Vadavathi, A.R. ; Hoogsteen, G. ; Hurink, J.L.</creator><creatorcontrib>Vadavathi, A.R. ; Hoogsteen, G. ; Hurink, J.L.</creatorcontrib><description>Low voltage distribution networks incorporating solar photovoltaic (PV) panels experience overvoltage and voltage unbalance during periods of low load and high PV generation. Resolving overvoltage by active power curtailment (APC) is an effective and cost-efficient solution. However, current APC techniques result in excessive and unfair power curtailment for prosumers at the sensitive parts of the grid that might induce neutral current. In this work, an analytical approach for fair APC and Reactive Power Control is presented for voltage regulation along with neutral current compensation. The desired power quality is maintained by controlling each phase of the PV inverter independently. The proposed algorithm regulates the voltage at the point of common coupling (PCC) within grid limits, eliminates neutral current, and reduces the grid unbalance. Furthermore, the results demonstrate that reducing the neutral current reduces the voltage at the PCC and consequently decreases the power curtailment required for overvoltage regulation.</description><identifier>ISSN: 1949-3053</identifier><identifier>EISSN: 1949-3061</identifier><identifier>DOI: 10.1109/TSG.2023.3244601</identifier><identifier>CODEN: ITSGBQ</identifier><language>eng</language><publisher>Piscataway: IEEE</publisher><subject>Algorithms ; Analytical models ; Costs ; Distributed power generation ; Distribution networks ; Inverters ; Low voltage ; Neutral currents ; Overvoltage ; Photovoltaic cells ; Power control ; Power generation control ; Production ; Quality control ; Reactive power ; Transformers ; Unbalance ; Voltage control</subject><ispartof>IEEE transactions on smart grid, 2023-09, Vol.14 (5), p.1-1</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2023</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c292t-8bbeac63a9d87cb4406392d39bd4e7349ae7042497a73ab9ac32d810adb56ff33</citedby><cites>FETCH-LOGICAL-c292t-8bbeac63a9d87cb4406392d39bd4e7349ae7042497a73ab9ac32d810adb56ff33</cites><orcidid>0000-0001-6986-5633 ; 0000-0002-0606-9952 ; 0000-0002-5396-3682</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/10044253$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,776,780,792,27901,27902,54733</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/10044253$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Vadavathi, A.R.</creatorcontrib><creatorcontrib>Hoogsteen, G.</creatorcontrib><creatorcontrib>Hurink, J.L.</creatorcontrib><title>PV Inverter Based Fair Power Quality Control</title><title>IEEE transactions on smart grid</title><addtitle>TSG</addtitle><description>Low voltage distribution networks incorporating solar photovoltaic (PV) panels experience overvoltage and voltage unbalance during periods of low load and high PV generation. Resolving overvoltage by active power curtailment (APC) is an effective and cost-efficient solution. However, current APC techniques result in excessive and unfair power curtailment for prosumers at the sensitive parts of the grid that might induce neutral current. In this work, an analytical approach for fair APC and Reactive Power Control is presented for voltage regulation along with neutral current compensation. The desired power quality is maintained by controlling each phase of the PV inverter independently. The proposed algorithm regulates the voltage at the point of common coupling (PCC) within grid limits, eliminates neutral current, and reduces the grid unbalance. Furthermore, the results demonstrate that reducing the neutral current reduces the voltage at the PCC and consequently decreases the power curtailment required for overvoltage regulation.</description><subject>Algorithms</subject><subject>Analytical models</subject><subject>Costs</subject><subject>Distributed power generation</subject><subject>Distribution networks</subject><subject>Inverters</subject><subject>Low voltage</subject><subject>Neutral currents</subject><subject>Overvoltage</subject><subject>Photovoltaic cells</subject><subject>Power control</subject><subject>Power generation control</subject><subject>Production</subject><subject>Quality control</subject><subject>Reactive power</subject><subject>Transformers</subject><subject>Unbalance</subject><subject>Voltage control</subject><issn>1949-3053</issn><issn>1949-3061</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNpNkNFLwzAQh4MoOObeffCh4KutyV2aNI9a3BwMnDh9DWmbQkdtZ9Ip--_N6BDv5Y7j-93BR8g1owljVN1v3hYJUMAEgXNB2RmZMMVVjFSw8785xUsy835LQyGiADUhd-uPaNl9WzdYFz0ab6tobhoXrfufsHjdm7YZDlHed4Pr2ytyUZvW29mpT8n7_GmTP8erl8Uyf1jFJSgY4qworCkFGlVlsiw4pwIVVKiKiluJXBkrKQeupJFoCmVKhCpj1FRFKuoacUpux7s713_trR_0tt-7LrzUkKWpBJDIAkVHqnS9987WeueaT-MOmlF91KKDFn3Uok9aQuRmjDTW2n845RxSxF9Yclve</recordid><startdate>20230901</startdate><enddate>20230901</enddate><creator>Vadavathi, A.R.</creator><creator>Hoogsteen, G.</creator><creator>Hurink, J.L.</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>KR7</scope><scope>L7M</scope><orcidid>https://orcid.org/0000-0001-6986-5633</orcidid><orcidid>https://orcid.org/0000-0002-0606-9952</orcidid><orcidid>https://orcid.org/0000-0002-5396-3682</orcidid></search><sort><creationdate>20230901</creationdate><title>PV Inverter Based Fair Power Quality Control</title><author>Vadavathi, A.R. ; Hoogsteen, G. ; Hurink, J.L.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c292t-8bbeac63a9d87cb4406392d39bd4e7349ae7042497a73ab9ac32d810adb56ff33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Algorithms</topic><topic>Analytical models</topic><topic>Costs</topic><topic>Distributed power generation</topic><topic>Distribution networks</topic><topic>Inverters</topic><topic>Low voltage</topic><topic>Neutral currents</topic><topic>Overvoltage</topic><topic>Photovoltaic cells</topic><topic>Power control</topic><topic>Power generation control</topic><topic>Production</topic><topic>Quality control</topic><topic>Reactive power</topic><topic>Transformers</topic><topic>Unbalance</topic><topic>Voltage control</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Vadavathi, A.R.</creatorcontrib><creatorcontrib>Hoogsteen, G.</creatorcontrib><creatorcontrib>Hurink, J.L.</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005–Present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>IEEE transactions on smart grid</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Vadavathi, A.R.</au><au>Hoogsteen, G.</au><au>Hurink, J.L.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>PV Inverter Based Fair Power Quality Control</atitle><jtitle>IEEE transactions on smart grid</jtitle><stitle>TSG</stitle><date>2023-09-01</date><risdate>2023</risdate><volume>14</volume><issue>5</issue><spage>1</spage><epage>1</epage><pages>1-1</pages><issn>1949-3053</issn><eissn>1949-3061</eissn><coden>ITSGBQ</coden><abstract>Low voltage distribution networks incorporating solar photovoltaic (PV) panels experience overvoltage and voltage unbalance during periods of low load and high PV generation. Resolving overvoltage by active power curtailment (APC) is an effective and cost-efficient solution. However, current APC techniques result in excessive and unfair power curtailment for prosumers at the sensitive parts of the grid that might induce neutral current. In this work, an analytical approach for fair APC and Reactive Power Control is presented for voltage regulation along with neutral current compensation. The desired power quality is maintained by controlling each phase of the PV inverter independently. The proposed algorithm regulates the voltage at the point of common coupling (PCC) within grid limits, eliminates neutral current, and reduces the grid unbalance. Furthermore, the results demonstrate that reducing the neutral current reduces the voltage at the PCC and consequently decreases the power curtailment required for overvoltage regulation.</abstract><cop>Piscataway</cop><pub>IEEE</pub><doi>10.1109/TSG.2023.3244601</doi><tpages>1</tpages><orcidid>https://orcid.org/0000-0001-6986-5633</orcidid><orcidid>https://orcid.org/0000-0002-0606-9952</orcidid><orcidid>https://orcid.org/0000-0002-5396-3682</orcidid></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1949-3053
ispartof IEEE transactions on smart grid, 2023-09, Vol.14 (5), p.1-1
issn 1949-3053
1949-3061
language eng
recordid cdi_crossref_primary_10_1109_TSG_2023_3244601
source IEEE Electronic Library (IEL)
subjects Algorithms
Analytical models
Costs
Distributed power generation
Distribution networks
Inverters
Low voltage
Neutral currents
Overvoltage
Photovoltaic cells
Power control
Power generation control
Production
Quality control
Reactive power
Transformers
Unbalance
Voltage control
title PV Inverter Based Fair Power Quality Control
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-29T05%3A33%3A13IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=PV%20Inverter%20Based%20Fair%20Power%20Quality%20Control&rft.jtitle=IEEE%20transactions%20on%20smart%20grid&rft.au=Vadavathi,%20A.R.&rft.date=2023-09-01&rft.volume=14&rft.issue=5&rft.spage=1&rft.epage=1&rft.pages=1-1&rft.issn=1949-3053&rft.eissn=1949-3061&rft.coden=ITSGBQ&rft_id=info:doi/10.1109/TSG.2023.3244601&rft_dat=%3Cproquest_RIE%3E2855722731%3C/proquest_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2855722731&rft_id=info:pmid/&rft_ieee_id=10044253&rfr_iscdi=true