Coordinated Protection and Control Based on Synchrophasor Data Processing in Smart Distribution Networks

Modern distribution grids are shifting toward resilient and sustainable energy networks through the use of unprecedented number of distributed generation (DG) units and renewable energy sources. However, unlike conventional grids, they are also highly integrative in the sense that, centralized contr...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on power systems 2018-01, Vol.33 (1), p.634-645
Hauptverfasser: Seyedi, Younes, Karimi, Houshang
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 645
container_issue 1
container_start_page 634
container_title IEEE transactions on power systems
container_volume 33
creator Seyedi, Younes
Karimi, Houshang
description Modern distribution grids are shifting toward resilient and sustainable energy networks through the use of unprecedented number of distributed generation (DG) units and renewable energy sources. However, unlike conventional grids, they are also highly integrative in the sense that, centralized control applications must support critical protective actions to reliably provide power to consumers. To achieve this goal, this paper presents a novel mechanism for coordinated protection and control of DG systems under permanent line faults in distribution networks. First, a centralized fault detector employs voltage phasors and frequency data to identify and isolate the fault within a tolerance time. Upon fault detection, a secondary control algorithm retrieves archived synchrophasor datasets to calculate real and reactive power disturbances caused by the fault isolation. In this mechanism, the secondary controller facilitates voltage/frequency recovery by adapting reference points of local controllers to the postfault conditions. Coordination is carried out based on the knowledge of the response time of protective devices and communication delays in control links. The proposed approach is a promising paradigm for reliable networked protection and improved situational awareness in smart distribution networks.
doi_str_mv 10.1109/TPWRS.2017.2708662
format Article
fullrecord <record><control><sourceid>crossref_RIE</sourceid><recordid>TN_cdi_crossref_primary_10_1109_TPWRS_2017_2708662</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>7934361</ieee_id><sourcerecordid>10_1109_TPWRS_2017_2708662</sourcerecordid><originalsourceid>FETCH-LOGICAL-c267t-7781ef69b11b647fe1d9f89a8dbeba5798a60cfbf8feb01e46932fe16f64f3d63</originalsourceid><addsrcrecordid>eNo9kNtKAzEQhoMoWKsvoDd5ga3JHnK41K0nKFpsxcsl2Z240bopSUT69qYHvBqY-b-f4UPokpIJpUReL-fvr4tJTiif5JwIxvIjNKJVJTLCuDxGIyJElQlZkVN0FsInIYSlwwj1tXO-s4OK0OG5dxHaaN2A1dDh2g3RuxW-VSEd03KxGdreu3WvgvN4qqLaIi2EYIcPbFPgW_mIpzZEb_XPrugZ4q_zX-EcnRi1CnBxmGP0dn-3rB-z2cvDU30zy9qc8ZhxLigYJjWlmpXcAO2kEVKJToNWFZdCMdIabYQBTSiUTBZ5SjHDSlN0rBijfN_beheCB9OsvU1vbRpKmq2rZueq2bpqDq4SdLWHLAD8A1wWZcFo8Qf99WkM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Coordinated Protection and Control Based on Synchrophasor Data Processing in Smart Distribution Networks</title><source>IEEE Electronic Library (IEL)</source><creator>Seyedi, Younes ; Karimi, Houshang</creator><creatorcontrib>Seyedi, Younes ; Karimi, Houshang</creatorcontrib><description>Modern distribution grids are shifting toward resilient and sustainable energy networks through the use of unprecedented number of distributed generation (DG) units and renewable energy sources. However, unlike conventional grids, they are also highly integrative in the sense that, centralized control applications must support critical protective actions to reliably provide power to consumers. To achieve this goal, this paper presents a novel mechanism for coordinated protection and control of DG systems under permanent line faults in distribution networks. First, a centralized fault detector employs voltage phasors and frequency data to identify and isolate the fault within a tolerance time. Upon fault detection, a secondary control algorithm retrieves archived synchrophasor datasets to calculate real and reactive power disturbances caused by the fault isolation. In this mechanism, the secondary controller facilitates voltage/frequency recovery by adapting reference points of local controllers to the postfault conditions. Coordination is carried out based on the knowledge of the response time of protective devices and communication delays in control links. The proposed approach is a promising paradigm for reliable networked protection and improved situational awareness in smart distribution networks.</description><identifier>ISSN: 0885-8950</identifier><identifier>EISSN: 1558-0679</identifier><identifier>DOI: 10.1109/TPWRS.2017.2708662</identifier><identifier>CODEN: ITPSEG</identifier><language>eng</language><publisher>IEEE</publisher><subject>Circuit faults ; Control ; Delays ; distributed generation ; Fault diagnosis ; Phasor measurement units ; Power system stability ; protection ; Relays ; renewable energy sources ; smart grid ; Stability analysis ; synchrophasor</subject><ispartof>IEEE transactions on power systems, 2018-01, Vol.33 (1), p.634-645</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c267t-7781ef69b11b647fe1d9f89a8dbeba5798a60cfbf8feb01e46932fe16f64f3d63</citedby><cites>FETCH-LOGICAL-c267t-7781ef69b11b647fe1d9f89a8dbeba5798a60cfbf8feb01e46932fe16f64f3d63</cites><orcidid>0000-0003-3986-4298 ; 0000-0003-4956-0925</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/7934361$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,776,780,792,27901,27902,54733</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/7934361$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Seyedi, Younes</creatorcontrib><creatorcontrib>Karimi, Houshang</creatorcontrib><title>Coordinated Protection and Control Based on Synchrophasor Data Processing in Smart Distribution Networks</title><title>IEEE transactions on power systems</title><addtitle>TPWRS</addtitle><description>Modern distribution grids are shifting toward resilient and sustainable energy networks through the use of unprecedented number of distributed generation (DG) units and renewable energy sources. However, unlike conventional grids, they are also highly integrative in the sense that, centralized control applications must support critical protective actions to reliably provide power to consumers. To achieve this goal, this paper presents a novel mechanism for coordinated protection and control of DG systems under permanent line faults in distribution networks. First, a centralized fault detector employs voltage phasors and frequency data to identify and isolate the fault within a tolerance time. Upon fault detection, a secondary control algorithm retrieves archived synchrophasor datasets to calculate real and reactive power disturbances caused by the fault isolation. In this mechanism, the secondary controller facilitates voltage/frequency recovery by adapting reference points of local controllers to the postfault conditions. Coordination is carried out based on the knowledge of the response time of protective devices and communication delays in control links. The proposed approach is a promising paradigm for reliable networked protection and improved situational awareness in smart distribution networks.</description><subject>Circuit faults</subject><subject>Control</subject><subject>Delays</subject><subject>distributed generation</subject><subject>Fault diagnosis</subject><subject>Phasor measurement units</subject><subject>Power system stability</subject><subject>protection</subject><subject>Relays</subject><subject>renewable energy sources</subject><subject>smart grid</subject><subject>Stability analysis</subject><subject>synchrophasor</subject><issn>0885-8950</issn><issn>1558-0679</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNo9kNtKAzEQhoMoWKsvoDd5ga3JHnK41K0nKFpsxcsl2Z240bopSUT69qYHvBqY-b-f4UPokpIJpUReL-fvr4tJTiif5JwIxvIjNKJVJTLCuDxGIyJElQlZkVN0FsInIYSlwwj1tXO-s4OK0OG5dxHaaN2A1dDh2g3RuxW-VSEd03KxGdreu3WvgvN4qqLaIi2EYIcPbFPgW_mIpzZEb_XPrugZ4q_zX-EcnRi1CnBxmGP0dn-3rB-z2cvDU30zy9qc8ZhxLigYJjWlmpXcAO2kEVKJToNWFZdCMdIabYQBTSiUTBZ5SjHDSlN0rBijfN_beheCB9OsvU1vbRpKmq2rZueq2bpqDq4SdLWHLAD8A1wWZcFo8Qf99WkM</recordid><startdate>201801</startdate><enddate>201801</enddate><creator>Seyedi, Younes</creator><creator>Karimi, Houshang</creator><general>IEEE</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0003-3986-4298</orcidid><orcidid>https://orcid.org/0000-0003-4956-0925</orcidid></search><sort><creationdate>201801</creationdate><title>Coordinated Protection and Control Based on Synchrophasor Data Processing in Smart Distribution Networks</title><author>Seyedi, Younes ; Karimi, Houshang</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c267t-7781ef69b11b647fe1d9f89a8dbeba5798a60cfbf8feb01e46932fe16f64f3d63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Circuit faults</topic><topic>Control</topic><topic>Delays</topic><topic>distributed generation</topic><topic>Fault diagnosis</topic><topic>Phasor measurement units</topic><topic>Power system stability</topic><topic>protection</topic><topic>Relays</topic><topic>renewable energy sources</topic><topic>smart grid</topic><topic>Stability analysis</topic><topic>synchrophasor</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Seyedi, Younes</creatorcontrib><creatorcontrib>Karimi, Houshang</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005–Present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><jtitle>IEEE transactions on power systems</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Seyedi, Younes</au><au>Karimi, Houshang</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Coordinated Protection and Control Based on Synchrophasor Data Processing in Smart Distribution Networks</atitle><jtitle>IEEE transactions on power systems</jtitle><stitle>TPWRS</stitle><date>2018-01</date><risdate>2018</risdate><volume>33</volume><issue>1</issue><spage>634</spage><epage>645</epage><pages>634-645</pages><issn>0885-8950</issn><eissn>1558-0679</eissn><coden>ITPSEG</coden><abstract>Modern distribution grids are shifting toward resilient and sustainable energy networks through the use of unprecedented number of distributed generation (DG) units and renewable energy sources. However, unlike conventional grids, they are also highly integrative in the sense that, centralized control applications must support critical protective actions to reliably provide power to consumers. To achieve this goal, this paper presents a novel mechanism for coordinated protection and control of DG systems under permanent line faults in distribution networks. First, a centralized fault detector employs voltage phasors and frequency data to identify and isolate the fault within a tolerance time. Upon fault detection, a secondary control algorithm retrieves archived synchrophasor datasets to calculate real and reactive power disturbances caused by the fault isolation. In this mechanism, the secondary controller facilitates voltage/frequency recovery by adapting reference points of local controllers to the postfault conditions. Coordination is carried out based on the knowledge of the response time of protective devices and communication delays in control links. The proposed approach is a promising paradigm for reliable networked protection and improved situational awareness in smart distribution networks.</abstract><pub>IEEE</pub><doi>10.1109/TPWRS.2017.2708662</doi><tpages>12</tpages><orcidid>https://orcid.org/0000-0003-3986-4298</orcidid><orcidid>https://orcid.org/0000-0003-4956-0925</orcidid></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 0885-8950
ispartof IEEE transactions on power systems, 2018-01, Vol.33 (1), p.634-645
issn 0885-8950
1558-0679
language eng
recordid cdi_crossref_primary_10_1109_TPWRS_2017_2708662
source IEEE Electronic Library (IEL)
subjects Circuit faults
Control
Delays
distributed generation
Fault diagnosis
Phasor measurement units
Power system stability
protection
Relays
renewable energy sources
smart grid
Stability analysis
synchrophasor
title Coordinated Protection and Control Based on Synchrophasor Data Processing in Smart Distribution Networks
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-29T02%3A31%3A02IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Coordinated%20Protection%20and%20Control%20Based%20on%20Synchrophasor%20Data%20Processing%20in%20Smart%20Distribution%20Networks&rft.jtitle=IEEE%20transactions%20on%20power%20systems&rft.au=Seyedi,%20Younes&rft.date=2018-01&rft.volume=33&rft.issue=1&rft.spage=634&rft.epage=645&rft.pages=634-645&rft.issn=0885-8950&rft.eissn=1558-0679&rft.coden=ITPSEG&rft_id=info:doi/10.1109/TPWRS.2017.2708662&rft_dat=%3Ccrossref_RIE%3E10_1109_TPWRS_2017_2708662%3C/crossref_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=7934361&rfr_iscdi=true