Sensitivity of AC adjustable speed drives to voltage sags and short interruptions
This paper discusses the sensitivity of adjustable speed drives (ASDs) to voltage sags and short interruptions on the basis of extensive test results. Existing standards and previously published work are critically reviewed, and a description of test procedures needed for appropriate assessment of A...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on power delivery 2005-01, Vol.20 (1), p.494-505 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 505 |
---|---|
container_issue | 1 |
container_start_page | 494 |
container_title | IEEE transactions on power delivery |
container_volume | 20 |
creator | Djokic, S.Z. Stockman, K. Milanovic, J.V. Desmet, J.J.M. Belmans, R. |
description | This paper discusses the sensitivity of adjustable speed drives (ASDs) to voltage sags and short interruptions on the basis of extensive test results. Existing standards and previously published work are critically reviewed, and a description of test procedures needed for appropriate assessment of ASD sensitivity is presented. The following tests were performed: sensitivity to rectangular three-phase, two-phase, and single-phase voltage sags with ideal and nonideal supply characteristics, as well as sensitivity to nonrectangular-balanced three-phase voltage sags similar to those caused by the starting of large motors. The results show that although the behavior of this equipment has a rather complex pattern, a simple representation of ASD sensitivity to various types of voltage sags and short interruption can be established. |
doi_str_mv | 10.1109/TPWRD.2004.832353 |
format | Article |
fullrecord | <record><control><sourceid>crossref_RIE</sourceid><recordid>TN_cdi_crossref_primary_10_1109_TPWRD_2004_832353</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>1375132</ieee_id><sourcerecordid>10_1109_TPWRD_2004_832353</sourcerecordid><originalsourceid>FETCH-LOGICAL-c265t-1400d1dd881aee012727f7efde88525b95e9d3201f4a231f29065cd0c05536fc3</originalsourceid><addsrcrecordid>eNpFkN1KAzEQhYMoWKsPIN7kBXadJJsmuSxVq1Dwr-Llkm4mNaXuliQt9O3dWsGrgcN3DsNHyDWDkjEwt_OXz7e7kgNUpRZcSHFCBswIVVQc9CkZgNay0Eapc3KR0gp6EAwMyOs7tinksAt5TztPxxNq3Wqbsl2skaYNoqMuhh0mmju669bZLvvcLhO1raPpq4uZhjZjjNtNDl2bLsmZt-uEV393SD4e7ueTx2L2PH2ajGdFw0cyF6wCcMw5rZlFBMYVV16hd9h_yuXCSDROcGC-slwwzw2MZOOgASnFyDdiSNhxt4ldShF9vYnh28Z9zaA-OKl_ndQHJ_XRSd-5OXYCIv7zQknWAz8AbF53</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Sensitivity of AC adjustable speed drives to voltage sags and short interruptions</title><source>IEEE Electronic Library (IEL)</source><creator>Djokic, S.Z. ; Stockman, K. ; Milanovic, J.V. ; Desmet, J.J.M. ; Belmans, R.</creator><creatorcontrib>Djokic, S.Z. ; Stockman, K. ; Milanovic, J.V. ; Desmet, J.J.M. ; Belmans, R.</creatorcontrib><description>This paper discusses the sensitivity of adjustable speed drives (ASDs) to voltage sags and short interruptions on the basis of extensive test results. Existing standards and previously published work are critically reviewed, and a description of test procedures needed for appropriate assessment of ASD sensitivity is presented. The following tests were performed: sensitivity to rectangular three-phase, two-phase, and single-phase voltage sags with ideal and nonideal supply characteristics, as well as sensitivity to nonrectangular-balanced three-phase voltage sags similar to those caused by the starting of large motors. The results show that although the behavior of this equipment has a rather complex pattern, a simple representation of ASD sensitivity to various types of voltage sags and short interruption can be established.</description><identifier>ISSN: 0885-8977</identifier><identifier>EISSN: 1937-4208</identifier><identifier>DOI: 10.1109/TPWRD.2004.832353</identifier><identifier>CODEN: ITPDE5</identifier><language>eng</language><publisher>IEEE</publisher><subject>Analog-digital conversion ; and single-phase voltage sags and short interruptions ; Frequency conversion ; Mechanical variables control ; Nonideal power supply characteristics ; Power quality ; Pulse width modulation inverters ; rectangular and nonrectangular three-phase ; Synchronous motors ; Testing ; Threshold voltage ; two-phase ; Variable speed drives ; Voltage control ; voltage-tolerance curve</subject><ispartof>IEEE transactions on power delivery, 2005-01, Vol.20 (1), p.494-505</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c265t-1400d1dd881aee012727f7efde88525b95e9d3201f4a231f29065cd0c05536fc3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/1375132$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,776,780,792,27901,27902,54733</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/1375132$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Djokic, S.Z.</creatorcontrib><creatorcontrib>Stockman, K.</creatorcontrib><creatorcontrib>Milanovic, J.V.</creatorcontrib><creatorcontrib>Desmet, J.J.M.</creatorcontrib><creatorcontrib>Belmans, R.</creatorcontrib><title>Sensitivity of AC adjustable speed drives to voltage sags and short interruptions</title><title>IEEE transactions on power delivery</title><addtitle>TPWRD</addtitle><description>This paper discusses the sensitivity of adjustable speed drives (ASDs) to voltage sags and short interruptions on the basis of extensive test results. Existing standards and previously published work are critically reviewed, and a description of test procedures needed for appropriate assessment of ASD sensitivity is presented. The following tests were performed: sensitivity to rectangular three-phase, two-phase, and single-phase voltage sags with ideal and nonideal supply characteristics, as well as sensitivity to nonrectangular-balanced three-phase voltage sags similar to those caused by the starting of large motors. The results show that although the behavior of this equipment has a rather complex pattern, a simple representation of ASD sensitivity to various types of voltage sags and short interruption can be established.</description><subject>Analog-digital conversion</subject><subject>and single-phase voltage sags and short interruptions</subject><subject>Frequency conversion</subject><subject>Mechanical variables control</subject><subject>Nonideal power supply characteristics</subject><subject>Power quality</subject><subject>Pulse width modulation inverters</subject><subject>rectangular and nonrectangular three-phase</subject><subject>Synchronous motors</subject><subject>Testing</subject><subject>Threshold voltage</subject><subject>two-phase</subject><subject>Variable speed drives</subject><subject>Voltage control</subject><subject>voltage-tolerance curve</subject><issn>0885-8977</issn><issn>1937-4208</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNpFkN1KAzEQhYMoWKsPIN7kBXadJJsmuSxVq1Dwr-Llkm4mNaXuliQt9O3dWsGrgcN3DsNHyDWDkjEwt_OXz7e7kgNUpRZcSHFCBswIVVQc9CkZgNay0Eapc3KR0gp6EAwMyOs7tinksAt5TztPxxNq3Wqbsl2skaYNoqMuhh0mmju669bZLvvcLhO1raPpq4uZhjZjjNtNDl2bLsmZt-uEV393SD4e7ueTx2L2PH2ajGdFw0cyF6wCcMw5rZlFBMYVV16hd9h_yuXCSDROcGC-slwwzw2MZOOgASnFyDdiSNhxt4ldShF9vYnh28Z9zaA-OKl_ndQHJ_XRSd-5OXYCIv7zQknWAz8AbF53</recordid><startdate>200501</startdate><enddate>200501</enddate><creator>Djokic, S.Z.</creator><creator>Stockman, K.</creator><creator>Milanovic, J.V.</creator><creator>Desmet, J.J.M.</creator><creator>Belmans, R.</creator><general>IEEE</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>200501</creationdate><title>Sensitivity of AC adjustable speed drives to voltage sags and short interruptions</title><author>Djokic, S.Z. ; Stockman, K. ; Milanovic, J.V. ; Desmet, J.J.M. ; Belmans, R.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c265t-1400d1dd881aee012727f7efde88525b95e9d3201f4a231f29065cd0c05536fc3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Analog-digital conversion</topic><topic>and single-phase voltage sags and short interruptions</topic><topic>Frequency conversion</topic><topic>Mechanical variables control</topic><topic>Nonideal power supply characteristics</topic><topic>Power quality</topic><topic>Pulse width modulation inverters</topic><topic>rectangular and nonrectangular three-phase</topic><topic>Synchronous motors</topic><topic>Testing</topic><topic>Threshold voltage</topic><topic>two-phase</topic><topic>Variable speed drives</topic><topic>Voltage control</topic><topic>voltage-tolerance curve</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Djokic, S.Z.</creatorcontrib><creatorcontrib>Stockman, K.</creatorcontrib><creatorcontrib>Milanovic, J.V.</creatorcontrib><creatorcontrib>Desmet, J.J.M.</creatorcontrib><creatorcontrib>Belmans, R.</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><jtitle>IEEE transactions on power delivery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Djokic, S.Z.</au><au>Stockman, K.</au><au>Milanovic, J.V.</au><au>Desmet, J.J.M.</au><au>Belmans, R.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Sensitivity of AC adjustable speed drives to voltage sags and short interruptions</atitle><jtitle>IEEE transactions on power delivery</jtitle><stitle>TPWRD</stitle><date>2005-01</date><risdate>2005</risdate><volume>20</volume><issue>1</issue><spage>494</spage><epage>505</epage><pages>494-505</pages><issn>0885-8977</issn><eissn>1937-4208</eissn><coden>ITPDE5</coden><abstract>This paper discusses the sensitivity of adjustable speed drives (ASDs) to voltage sags and short interruptions on the basis of extensive test results. Existing standards and previously published work are critically reviewed, and a description of test procedures needed for appropriate assessment of ASD sensitivity is presented. The following tests were performed: sensitivity to rectangular three-phase, two-phase, and single-phase voltage sags with ideal and nonideal supply characteristics, as well as sensitivity to nonrectangular-balanced three-phase voltage sags similar to those caused by the starting of large motors. The results show that although the behavior of this equipment has a rather complex pattern, a simple representation of ASD sensitivity to various types of voltage sags and short interruption can be established.</abstract><pub>IEEE</pub><doi>10.1109/TPWRD.2004.832353</doi><tpages>12</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 0885-8977 |
ispartof | IEEE transactions on power delivery, 2005-01, Vol.20 (1), p.494-505 |
issn | 0885-8977 1937-4208 |
language | eng |
recordid | cdi_crossref_primary_10_1109_TPWRD_2004_832353 |
source | IEEE Electronic Library (IEL) |
subjects | Analog-digital conversion and single-phase voltage sags and short interruptions Frequency conversion Mechanical variables control Nonideal power supply characteristics Power quality Pulse width modulation inverters rectangular and nonrectangular three-phase Synchronous motors Testing Threshold voltage two-phase Variable speed drives Voltage control voltage-tolerance curve |
title | Sensitivity of AC adjustable speed drives to voltage sags and short interruptions |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-04T01%3A04%3A39IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Sensitivity%20of%20AC%20adjustable%20speed%20drives%20to%20voltage%20sags%20and%20short%20interruptions&rft.jtitle=IEEE%20transactions%20on%20power%20delivery&rft.au=Djokic,%20S.Z.&rft.date=2005-01&rft.volume=20&rft.issue=1&rft.spage=494&rft.epage=505&rft.pages=494-505&rft.issn=0885-8977&rft.eissn=1937-4208&rft.coden=ITPDE5&rft_id=info:doi/10.1109/TPWRD.2004.832353&rft_dat=%3Ccrossref_RIE%3E10_1109_TPWRD_2004_832353%3C/crossref_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=1375132&rfr_iscdi=true |