An Online ESR Estimation Method for Output Capacitor of DC-DC Boost Converter Without Current Sensor
Aluminum electrolytic capacitors (AEC) as a high energy density, low-cost energy storage component, are widely used in power electronic converters to stabilize the output voltage. However, the AEC is reported as a vulnerable component, threatening the reliability of power electronic converters. The...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on power electronics 2025-01, Vol.40 (1), p.2196-2209 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 2209 |
---|---|
container_issue | 1 |
container_start_page | 2196 |
container_title | IEEE transactions on power electronics |
container_volume | 40 |
creator | Leong, Chio-Hong Wong, Chi-Kong Lam, Chi-Seng |
description | Aluminum electrolytic capacitors (AEC) as a high energy density, low-cost energy storage component, are widely used in power electronic converters to stabilize the output voltage. However, the AEC is reported as a vulnerable component, threatening the reliability of power electronic converters. The health status of AEC is reflected in the variation of its equivalent series resistance (ESR). Therefore, it is necessary to monitor the ESR of AEC to guarantee the safety and reliability of converters. This article presents a novel ESR online estimation method for both continuous and discontinuous conduction modes of dc-dc boost converter based on output voltage ripple information without using any current sensor. This method is characterized with cost-effective implementation, less computational burden, and acceptable accuracy. In this article, the calculation model of ESR, online ESR estimation method, and the corresponding hardware implementation are presented. Finally, simulation and experiment results are presented to verify the validity, effectiveness, and feasibility of the proposed method in comparison with different estimation methods. |
doi_str_mv | 10.1109/TPEL.2024.3470814 |
format | Article |
fullrecord | <record><control><sourceid>crossref_RIE</sourceid><recordid>TN_cdi_crossref_primary_10_1109_TPEL_2024_3470814</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>10700043</ieee_id><sourcerecordid>10_1109_TPEL_2024_3470814</sourcerecordid><originalsourceid>FETCH-LOGICAL-c633-1fc8c14626db5129cad491308cb7e5a346080d856d31f57e2b58835450f79843</originalsourceid><addsrcrecordid>eNpNkF1LwzAUhoMoOKc_QPAif6DznCZpk8vZ1Q-YTNzAy9KlCVZmMpJM8N_bsl14deCc9znwPoTcIswQQd1v3urlLIeczxgvQSI_IxNUHDNAKM_JBKQUmVSKXZKrGL8AkAvACenmjq7crneG1ut3WsfUf7ep946-mvTpO2p9oKtD2h8Srdp9q_s0LLyliypbVPTB-zgcvPsxIZlAP_oBGqOHEIxLdG1c9OGaXNh2F83NaU7J-rHeVM_ZcvX0Us2XmS4Yy9BqqZEXedFtBeZKtx1XyEDqbWlEy3gBEjopio6hFaXJt0JKJoYetlSSsynB41cdfIzB2GYfhjLht0FoRknNKKkZJTUnSQNzd2R6Y8y_fAkAnLE_zq5iIg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>An Online ESR Estimation Method for Output Capacitor of DC-DC Boost Converter Without Current Sensor</title><source>IEEE Electronic Library (IEL)</source><creator>Leong, Chio-Hong ; Wong, Chi-Kong ; Lam, Chi-Seng</creator><creatorcontrib>Leong, Chio-Hong ; Wong, Chi-Kong ; Lam, Chi-Seng</creatorcontrib><description>Aluminum electrolytic capacitors (AEC) as a high energy density, low-cost energy storage component, are widely used in power electronic converters to stabilize the output voltage. However, the AEC is reported as a vulnerable component, threatening the reliability of power electronic converters. The health status of AEC is reflected in the variation of its equivalent series resistance (ESR). Therefore, it is necessary to monitor the ESR of AEC to guarantee the safety and reliability of converters. This article presents a novel ESR online estimation method for both continuous and discontinuous conduction modes of dc-dc boost converter based on output voltage ripple information without using any current sensor. This method is characterized with cost-effective implementation, less computational burden, and acceptable accuracy. In this article, the calculation model of ESR, online ESR estimation method, and the corresponding hardware implementation are presented. Finally, simulation and experiment results are presented to verify the validity, effectiveness, and feasibility of the proposed method in comparison with different estimation methods.</description><identifier>ISSN: 0885-8993</identifier><identifier>EISSN: 1941-0107</identifier><identifier>DOI: 10.1109/TPEL.2024.3470814</identifier><identifier>CODEN: ITPEE8</identifier><language>eng</language><publisher>IEEE</publisher><subject>Aluminum electrolytic capacitor (AEC) ; boost converter ; Capacitors ; Control systems ; Costs ; Data mining ; ESR estimation ; Estimation ; Inductors ; Matlab ; online identification ; Switches ; Transient analysis ; Voltage control ; voltage ripple</subject><ispartof>IEEE transactions on power electronics, 2025-01, Vol.40 (1), p.2196-2209</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c633-1fc8c14626db5129cad491308cb7e5a346080d856d31f57e2b58835450f79843</cites><orcidid>0000-0002-1058-3321 ; 0000-0003-3669-6743</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/10700043$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,780,784,796,27924,27925,54758</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/10700043$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Leong, Chio-Hong</creatorcontrib><creatorcontrib>Wong, Chi-Kong</creatorcontrib><creatorcontrib>Lam, Chi-Seng</creatorcontrib><title>An Online ESR Estimation Method for Output Capacitor of DC-DC Boost Converter Without Current Sensor</title><title>IEEE transactions on power electronics</title><addtitle>TPEL</addtitle><description>Aluminum electrolytic capacitors (AEC) as a high energy density, low-cost energy storage component, are widely used in power electronic converters to stabilize the output voltage. However, the AEC is reported as a vulnerable component, threatening the reliability of power electronic converters. The health status of AEC is reflected in the variation of its equivalent series resistance (ESR). Therefore, it is necessary to monitor the ESR of AEC to guarantee the safety and reliability of converters. This article presents a novel ESR online estimation method for both continuous and discontinuous conduction modes of dc-dc boost converter based on output voltage ripple information without using any current sensor. This method is characterized with cost-effective implementation, less computational burden, and acceptable accuracy. In this article, the calculation model of ESR, online ESR estimation method, and the corresponding hardware implementation are presented. Finally, simulation and experiment results are presented to verify the validity, effectiveness, and feasibility of the proposed method in comparison with different estimation methods.</description><subject>Aluminum electrolytic capacitor (AEC)</subject><subject>boost converter</subject><subject>Capacitors</subject><subject>Control systems</subject><subject>Costs</subject><subject>Data mining</subject><subject>ESR estimation</subject><subject>Estimation</subject><subject>Inductors</subject><subject>Matlab</subject><subject>online identification</subject><subject>Switches</subject><subject>Transient analysis</subject><subject>Voltage control</subject><subject>voltage ripple</subject><issn>0885-8993</issn><issn>1941-0107</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2025</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNpNkF1LwzAUhoMoOKc_QPAif6DznCZpk8vZ1Q-YTNzAy9KlCVZmMpJM8N_bsl14deCc9znwPoTcIswQQd1v3urlLIeczxgvQSI_IxNUHDNAKM_JBKQUmVSKXZKrGL8AkAvACenmjq7crneG1ut3WsfUf7ep946-mvTpO2p9oKtD2h8Srdp9q_s0LLyliypbVPTB-zgcvPsxIZlAP_oBGqOHEIxLdG1c9OGaXNh2F83NaU7J-rHeVM_ZcvX0Us2XmS4Yy9BqqZEXedFtBeZKtx1XyEDqbWlEy3gBEjopio6hFaXJt0JKJoYetlSSsynB41cdfIzB2GYfhjLht0FoRknNKKkZJTUnSQNzd2R6Y8y_fAkAnLE_zq5iIg</recordid><startdate>202501</startdate><enddate>202501</enddate><creator>Leong, Chio-Hong</creator><creator>Wong, Chi-Kong</creator><creator>Lam, Chi-Seng</creator><general>IEEE</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0002-1058-3321</orcidid><orcidid>https://orcid.org/0000-0003-3669-6743</orcidid></search><sort><creationdate>202501</creationdate><title>An Online ESR Estimation Method for Output Capacitor of DC-DC Boost Converter Without Current Sensor</title><author>Leong, Chio-Hong ; Wong, Chi-Kong ; Lam, Chi-Seng</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c633-1fc8c14626db5129cad491308cb7e5a346080d856d31f57e2b58835450f79843</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2025</creationdate><topic>Aluminum electrolytic capacitor (AEC)</topic><topic>boost converter</topic><topic>Capacitors</topic><topic>Control systems</topic><topic>Costs</topic><topic>Data mining</topic><topic>ESR estimation</topic><topic>Estimation</topic><topic>Inductors</topic><topic>Matlab</topic><topic>online identification</topic><topic>Switches</topic><topic>Transient analysis</topic><topic>Voltage control</topic><topic>voltage ripple</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Leong, Chio-Hong</creatorcontrib><creatorcontrib>Wong, Chi-Kong</creatorcontrib><creatorcontrib>Lam, Chi-Seng</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><jtitle>IEEE transactions on power electronics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Leong, Chio-Hong</au><au>Wong, Chi-Kong</au><au>Lam, Chi-Seng</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>An Online ESR Estimation Method for Output Capacitor of DC-DC Boost Converter Without Current Sensor</atitle><jtitle>IEEE transactions on power electronics</jtitle><stitle>TPEL</stitle><date>2025-01</date><risdate>2025</risdate><volume>40</volume><issue>1</issue><spage>2196</spage><epage>2209</epage><pages>2196-2209</pages><issn>0885-8993</issn><eissn>1941-0107</eissn><coden>ITPEE8</coden><abstract>Aluminum electrolytic capacitors (AEC) as a high energy density, low-cost energy storage component, are widely used in power electronic converters to stabilize the output voltage. However, the AEC is reported as a vulnerable component, threatening the reliability of power electronic converters. The health status of AEC is reflected in the variation of its equivalent series resistance (ESR). Therefore, it is necessary to monitor the ESR of AEC to guarantee the safety and reliability of converters. This article presents a novel ESR online estimation method for both continuous and discontinuous conduction modes of dc-dc boost converter based on output voltage ripple information without using any current sensor. This method is characterized with cost-effective implementation, less computational burden, and acceptable accuracy. In this article, the calculation model of ESR, online ESR estimation method, and the corresponding hardware implementation are presented. Finally, simulation and experiment results are presented to verify the validity, effectiveness, and feasibility of the proposed method in comparison with different estimation methods.</abstract><pub>IEEE</pub><doi>10.1109/TPEL.2024.3470814</doi><tpages>14</tpages><orcidid>https://orcid.org/0000-0002-1058-3321</orcidid><orcidid>https://orcid.org/0000-0003-3669-6743</orcidid></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 0885-8993 |
ispartof | IEEE transactions on power electronics, 2025-01, Vol.40 (1), p.2196-2209 |
issn | 0885-8993 1941-0107 |
language | eng |
recordid | cdi_crossref_primary_10_1109_TPEL_2024_3470814 |
source | IEEE Electronic Library (IEL) |
subjects | Aluminum electrolytic capacitor (AEC) boost converter Capacitors Control systems Costs Data mining ESR estimation Estimation Inductors Matlab online identification Switches Transient analysis Voltage control voltage ripple |
title | An Online ESR Estimation Method for Output Capacitor of DC-DC Boost Converter Without Current Sensor |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-20T06%3A38%3A46IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=An%20Online%20ESR%20Estimation%20Method%20for%20Output%20Capacitor%20of%20DC-DC%20Boost%20Converter%20Without%20Current%20Sensor&rft.jtitle=IEEE%20transactions%20on%20power%20electronics&rft.au=Leong,%20Chio-Hong&rft.date=2025-01&rft.volume=40&rft.issue=1&rft.spage=2196&rft.epage=2209&rft.pages=2196-2209&rft.issn=0885-8993&rft.eissn=1941-0107&rft.coden=ITPEE8&rft_id=info:doi/10.1109/TPEL.2024.3470814&rft_dat=%3Ccrossref_RIE%3E10_1109_TPEL_2024_3470814%3C/crossref_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=10700043&rfr_iscdi=true |