A Morphological Peak-Detector for Single-Unit Neural Recording Acquisition Systems
The increasing demand for measurement systems in neuroscience with the ability to acquire signals at neuron-level resolution has led to the development of techniques based on innovative organic biosensors. These single-unit extracellular neural recording systems provide useful information on neural...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on instrumentation and measurement 2022, Vol.71, p.1-11 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 11 |
---|---|
container_issue | |
container_start_page | 1 |
container_title | IEEE transactions on instrumentation and measurement |
container_volume | 71 |
creator | Galli, Alessandra Lago, Nicolo Tonello, Sarah Bortolozzi, Mario Buonomo, Marco Pedersen, Morten Gram Cester, Andrea Giorgi, Giada |
description | The increasing demand for measurement systems in neuroscience with the ability to acquire signals at neuron-level resolution has led to the development of techniques based on innovative organic biosensors. These single-unit extracellular neural recording systems provide useful information on neural behavior in terms of the action potential (AP) firing mechanism. In this work, we propose a processing technique specifically designed to accurately and reliably extract single-cell APs generated by free and attached membranes from signals acquired by extracellular recording devices. The simultaneous presence of overlapped APs, due to the nonideal coupling between cell and surface device, involves a distortion of the signal acquired by the device. Such distortion makes APs detection challenging. The proposed approach consists of a morphological peak detector characterized by high selectivity and based on three stages: a denoising phase for reducing wideband noise performed by the empirical mode decomposition (EMD) technique, and a threshold-based classifier for the identification of all the possible peaks that could correspond to an AP and a morphological classifier based on the support vector machine technique that improves the performances of the whole peak detection algorithm increasing its selectivity. The proposed method was designed on simulated data obtained by taking cell-to-cell variability into account in order to adapt the proposed method to the heterogeneity of the biological reality rather than the average behavior of the cells. This point is crucial to design an approach suitable for applications in vivo . Finally, the morphological classifier was tested on simulated and semisimulated data obtained from experimental acquisitions measured from the axons of a giant squid in response to current stimulation, achieving F1-score > 89% for both scenarios. |
doi_str_mv | 10.1109/TIM.2022.3157006 |
format | Article |
fullrecord | <record><control><sourceid>proquest_RIE</sourceid><recordid>TN_cdi_crossref_primary_10_1109_TIM_2022_3157006</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>9729229</ieee_id><sourcerecordid>2642006012</sourcerecordid><originalsourceid>FETCH-LOGICAL-c244t-3cbf24965082771493b29143545c0ade930ddbf3650a95b78e61132b0ec3410f3</originalsourceid><addsrcrecordid>eNo9kEtLAzEURoMoWKt7wc2A66k372ZZ6qvQqvSxDjOZTE2dNm0ys-i_N9Li4vLB5Xz3wkHoHsMAY1BPy8lsQICQAcVcAogL1MOcy1wJQS5RDwAPc8W4uEY3MW4AQAome2g-ymY-7L9949fOFE32ZYuf_Nm21rQ-ZHWahdutG5uvdq7NPmwXEjS3xocq7bOROXQuutb5XbY4xtZu4y26qosm2rtz9tHq9WU5fs-nn2-T8WiaG8JYm1NT1oQpwWFIpMRM0ZIozChn3EBRWUWhqsqaJqBQvJRDKzCmpARrKMNQ0z56PN3dB3_obGz1xndhl15qIhhJDgCTRMGJMsHHGGyt98Fti3DUGPSfOZ3M6T9z-mwuVR5OFWet_ceVJIoQRX8BaRVoYw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2642006012</pqid></control><display><type>article</type><title>A Morphological Peak-Detector for Single-Unit Neural Recording Acquisition Systems</title><source>IEEE Electronic Library (IEL)</source><creator>Galli, Alessandra ; Lago, Nicolo ; Tonello, Sarah ; Bortolozzi, Mario ; Buonomo, Marco ; Pedersen, Morten Gram ; Cester, Andrea ; Giorgi, Giada</creator><creatorcontrib>Galli, Alessandra ; Lago, Nicolo ; Tonello, Sarah ; Bortolozzi, Mario ; Buonomo, Marco ; Pedersen, Morten Gram ; Cester, Andrea ; Giorgi, Giada</creatorcontrib><description>The increasing demand for measurement systems in neuroscience with the ability to acquire signals at neuron-level resolution has led to the development of techniques based on innovative organic biosensors. These single-unit extracellular neural recording systems provide useful information on neural behavior in terms of the action potential (AP) firing mechanism. In this work, we propose a processing technique specifically designed to accurately and reliably extract single-cell APs generated by free and attached membranes from signals acquired by extracellular recording devices. The simultaneous presence of overlapped APs, due to the nonideal coupling between cell and surface device, involves a distortion of the signal acquired by the device. Such distortion makes APs detection challenging. The proposed approach consists of a morphological peak detector characterized by high selectivity and based on three stages: a denoising phase for reducing wideband noise performed by the empirical mode decomposition (EMD) technique, and a threshold-based classifier for the identification of all the possible peaks that could correspond to an AP and a morphological classifier based on the support vector machine technique that improves the performances of the whole peak detection algorithm increasing its selectivity. The proposed method was designed on simulated data obtained by taking cell-to-cell variability into account in order to adapt the proposed method to the heterogeneity of the biological reality rather than the average behavior of the cells. This point is crucial to design an approach suitable for applications in vivo . Finally, the morphological classifier was tested on simulated and semisimulated data obtained from experimental acquisitions measured from the axons of a giant squid in response to current stimulation, achieving F1-score > 89% for both scenarios.</description><identifier>ISSN: 0018-9456</identifier><identifier>EISSN: 1557-9662</identifier><identifier>DOI: 10.1109/TIM.2022.3157006</identifier><identifier>CODEN: IEIMAO</identifier><language>eng</language><publisher>New York: IEEE</publisher><subject>Action potential (AP) ; Action potentials ; Biomembranes ; Distortion ; Electric potential ; Electrodes ; empirical model decomposition ; Extracellular ; extracellular recording ; morphological peak detector ; neural recording system ; Neurons ; single-cell activity ; support vector machine</subject><ispartof>IEEE transactions on instrumentation and measurement, 2022, Vol.71, p.1-11</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2022</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c244t-3cbf24965082771493b29143545c0ade930ddbf3650a95b78e61132b0ec3410f3</cites><orcidid>0000-0001-9498-4722 ; 0000-0001-7198-9838 ; 0000-0001-7309-6697 ; 0000-0001-7339-1549 ; 0000-0002-2639-2394 ; 0000-0002-7325-7988 ; 0000-0003-2416-0220 ; 0000-0001-6583-1735</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/9729229$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>315,781,785,797,4025,27928,27929,27930,54763</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/9729229$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Galli, Alessandra</creatorcontrib><creatorcontrib>Lago, Nicolo</creatorcontrib><creatorcontrib>Tonello, Sarah</creatorcontrib><creatorcontrib>Bortolozzi, Mario</creatorcontrib><creatorcontrib>Buonomo, Marco</creatorcontrib><creatorcontrib>Pedersen, Morten Gram</creatorcontrib><creatorcontrib>Cester, Andrea</creatorcontrib><creatorcontrib>Giorgi, Giada</creatorcontrib><title>A Morphological Peak-Detector for Single-Unit Neural Recording Acquisition Systems</title><title>IEEE transactions on instrumentation and measurement</title><addtitle>TIM</addtitle><description>The increasing demand for measurement systems in neuroscience with the ability to acquire signals at neuron-level resolution has led to the development of techniques based on innovative organic biosensors. These single-unit extracellular neural recording systems provide useful information on neural behavior in terms of the action potential (AP) firing mechanism. In this work, we propose a processing technique specifically designed to accurately and reliably extract single-cell APs generated by free and attached membranes from signals acquired by extracellular recording devices. The simultaneous presence of overlapped APs, due to the nonideal coupling between cell and surface device, involves a distortion of the signal acquired by the device. Such distortion makes APs detection challenging. The proposed approach consists of a morphological peak detector characterized by high selectivity and based on three stages: a denoising phase for reducing wideband noise performed by the empirical mode decomposition (EMD) technique, and a threshold-based classifier for the identification of all the possible peaks that could correspond to an AP and a morphological classifier based on the support vector machine technique that improves the performances of the whole peak detection algorithm increasing its selectivity. The proposed method was designed on simulated data obtained by taking cell-to-cell variability into account in order to adapt the proposed method to the heterogeneity of the biological reality rather than the average behavior of the cells. This point is crucial to design an approach suitable for applications in vivo . Finally, the morphological classifier was tested on simulated and semisimulated data obtained from experimental acquisitions measured from the axons of a giant squid in response to current stimulation, achieving F1-score > 89% for both scenarios.</description><subject>Action potential (AP)</subject><subject>Action potentials</subject><subject>Biomembranes</subject><subject>Distortion</subject><subject>Electric potential</subject><subject>Electrodes</subject><subject>empirical model decomposition</subject><subject>Extracellular</subject><subject>extracellular recording</subject><subject>morphological peak detector</subject><subject>neural recording system</subject><subject>Neurons</subject><subject>single-cell activity</subject><subject>support vector machine</subject><issn>0018-9456</issn><issn>1557-9662</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNo9kEtLAzEURoMoWKt7wc2A66k372ZZ6qvQqvSxDjOZTE2dNm0ys-i_N9Li4vLB5Xz3wkHoHsMAY1BPy8lsQICQAcVcAogL1MOcy1wJQS5RDwAPc8W4uEY3MW4AQAome2g-ymY-7L9949fOFE32ZYuf_Nm21rQ-ZHWahdutG5uvdq7NPmwXEjS3xocq7bOROXQuutb5XbY4xtZu4y26qosm2rtz9tHq9WU5fs-nn2-T8WiaG8JYm1NT1oQpwWFIpMRM0ZIozChn3EBRWUWhqsqaJqBQvJRDKzCmpARrKMNQ0z56PN3dB3_obGz1xndhl15qIhhJDgCTRMGJMsHHGGyt98Fti3DUGPSfOZ3M6T9z-mwuVR5OFWet_ceVJIoQRX8BaRVoYw</recordid><startdate>2022</startdate><enddate>2022</enddate><creator>Galli, Alessandra</creator><creator>Lago, Nicolo</creator><creator>Tonello, Sarah</creator><creator>Bortolozzi, Mario</creator><creator>Buonomo, Marco</creator><creator>Pedersen, Morten Gram</creator><creator>Cester, Andrea</creator><creator>Giorgi, Giada</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope><orcidid>https://orcid.org/0000-0001-9498-4722</orcidid><orcidid>https://orcid.org/0000-0001-7198-9838</orcidid><orcidid>https://orcid.org/0000-0001-7309-6697</orcidid><orcidid>https://orcid.org/0000-0001-7339-1549</orcidid><orcidid>https://orcid.org/0000-0002-2639-2394</orcidid><orcidid>https://orcid.org/0000-0002-7325-7988</orcidid><orcidid>https://orcid.org/0000-0003-2416-0220</orcidid><orcidid>https://orcid.org/0000-0001-6583-1735</orcidid></search><sort><creationdate>2022</creationdate><title>A Morphological Peak-Detector for Single-Unit Neural Recording Acquisition Systems</title><author>Galli, Alessandra ; Lago, Nicolo ; Tonello, Sarah ; Bortolozzi, Mario ; Buonomo, Marco ; Pedersen, Morten Gram ; Cester, Andrea ; Giorgi, Giada</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c244t-3cbf24965082771493b29143545c0ade930ddbf3650a95b78e61132b0ec3410f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Action potential (AP)</topic><topic>Action potentials</topic><topic>Biomembranes</topic><topic>Distortion</topic><topic>Electric potential</topic><topic>Electrodes</topic><topic>empirical model decomposition</topic><topic>Extracellular</topic><topic>extracellular recording</topic><topic>morphological peak detector</topic><topic>neural recording system</topic><topic>Neurons</topic><topic>single-cell activity</topic><topic>support vector machine</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Galli, Alessandra</creatorcontrib><creatorcontrib>Lago, Nicolo</creatorcontrib><creatorcontrib>Tonello, Sarah</creatorcontrib><creatorcontrib>Bortolozzi, Mario</creatorcontrib><creatorcontrib>Buonomo, Marco</creatorcontrib><creatorcontrib>Pedersen, Morten Gram</creatorcontrib><creatorcontrib>Cester, Andrea</creatorcontrib><creatorcontrib>Giorgi, Giada</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><collection>Electronics & Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>IEEE transactions on instrumentation and measurement</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Galli, Alessandra</au><au>Lago, Nicolo</au><au>Tonello, Sarah</au><au>Bortolozzi, Mario</au><au>Buonomo, Marco</au><au>Pedersen, Morten Gram</au><au>Cester, Andrea</au><au>Giorgi, Giada</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Morphological Peak-Detector for Single-Unit Neural Recording Acquisition Systems</atitle><jtitle>IEEE transactions on instrumentation and measurement</jtitle><stitle>TIM</stitle><date>2022</date><risdate>2022</risdate><volume>71</volume><spage>1</spage><epage>11</epage><pages>1-11</pages><issn>0018-9456</issn><eissn>1557-9662</eissn><coden>IEIMAO</coden><abstract>The increasing demand for measurement systems in neuroscience with the ability to acquire signals at neuron-level resolution has led to the development of techniques based on innovative organic biosensors. These single-unit extracellular neural recording systems provide useful information on neural behavior in terms of the action potential (AP) firing mechanism. In this work, we propose a processing technique specifically designed to accurately and reliably extract single-cell APs generated by free and attached membranes from signals acquired by extracellular recording devices. The simultaneous presence of overlapped APs, due to the nonideal coupling between cell and surface device, involves a distortion of the signal acquired by the device. Such distortion makes APs detection challenging. The proposed approach consists of a morphological peak detector characterized by high selectivity and based on three stages: a denoising phase for reducing wideband noise performed by the empirical mode decomposition (EMD) technique, and a threshold-based classifier for the identification of all the possible peaks that could correspond to an AP and a morphological classifier based on the support vector machine technique that improves the performances of the whole peak detection algorithm increasing its selectivity. The proposed method was designed on simulated data obtained by taking cell-to-cell variability into account in order to adapt the proposed method to the heterogeneity of the biological reality rather than the average behavior of the cells. This point is crucial to design an approach suitable for applications in vivo . Finally, the morphological classifier was tested on simulated and semisimulated data obtained from experimental acquisitions measured from the axons of a giant squid in response to current stimulation, achieving F1-score > 89% for both scenarios.</abstract><cop>New York</cop><pub>IEEE</pub><doi>10.1109/TIM.2022.3157006</doi><tpages>11</tpages><orcidid>https://orcid.org/0000-0001-9498-4722</orcidid><orcidid>https://orcid.org/0000-0001-7198-9838</orcidid><orcidid>https://orcid.org/0000-0001-7309-6697</orcidid><orcidid>https://orcid.org/0000-0001-7339-1549</orcidid><orcidid>https://orcid.org/0000-0002-2639-2394</orcidid><orcidid>https://orcid.org/0000-0002-7325-7988</orcidid><orcidid>https://orcid.org/0000-0003-2416-0220</orcidid><orcidid>https://orcid.org/0000-0001-6583-1735</orcidid></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 0018-9456 |
ispartof | IEEE transactions on instrumentation and measurement, 2022, Vol.71, p.1-11 |
issn | 0018-9456 1557-9662 |
language | eng |
recordid | cdi_crossref_primary_10_1109_TIM_2022_3157006 |
source | IEEE Electronic Library (IEL) |
subjects | Action potential (AP) Action potentials Biomembranes Distortion Electric potential Electrodes empirical model decomposition Extracellular extracellular recording morphological peak detector neural recording system Neurons single-cell activity support vector machine |
title | A Morphological Peak-Detector for Single-Unit Neural Recording Acquisition Systems |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-11T11%3A56%3A58IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Morphological%20Peak-Detector%20for%20Single-Unit%20Neural%20Recording%20Acquisition%20Systems&rft.jtitle=IEEE%20transactions%20on%20instrumentation%20and%20measurement&rft.au=Galli,%20Alessandra&rft.date=2022&rft.volume=71&rft.spage=1&rft.epage=11&rft.pages=1-11&rft.issn=0018-9456&rft.eissn=1557-9662&rft.coden=IEIMAO&rft_id=info:doi/10.1109/TIM.2022.3157006&rft_dat=%3Cproquest_RIE%3E2642006012%3C/proquest_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2642006012&rft_id=info:pmid/&rft_ieee_id=9729229&rfr_iscdi=true |