Complex Radar Cross Section Measurements of the Human Body for Breath-Activity Monitoring Applications
An experimental setup for complex mono-static radar cross section (RCS) measurements in the 1-10-GHz-frequency band, employing a suitably modified semianechoic chamber, is presented and characterized. The foreseen application is the measurement of the complex RCS of the human body during respiratory...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on instrumentation and measurement 2015-08, Vol.64 (8), p.2247-2258 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 2258 |
---|---|
container_issue | 8 |
container_start_page | 2247 |
container_title | IEEE transactions on instrumentation and measurement |
container_volume | 64 |
creator | Piuzzi, Emanuele D'Atanasio, Paolo Pisa, Stefano Pittella, Erika Zambotti, Alessandro |
description | An experimental setup for complex mono-static radar cross section (RCS) measurements in the 1-10-GHz-frequency band, employing a suitably modified semianechoic chamber, is presented and characterized. The foreseen application is the measurement of the complex RCS of the human body during respiratory activity, to ease the design and optimization of ultrawideband (UWB) radar systems for breath-activity monitoring. The proposed RCS test range is calibrated by means of a readily available aluminum flat panel and its performance is tested against canonical targets, evaluating uncertainty in magnitude, and phase measurements. The setup is then employed to carry out investigations on the complex RCS of a volunteer, focusing on its changes resulting from breath activity. Applying the measured RCS patterns to a specifically developed model, the feasibility of the UWB radar approach for achieving a continuous contact-less monitoring of breath activity in a subject at rest is clearly demonstrated. Finally, experimental tests of the application of the proposed radar technique to real-world scenarios are shown, and the safety of RCS measurements and UWB radar monitoring, with reference to exposure of the monitored subject to the radiated electromagnetic fields, is evaluated. |
doi_str_mv | 10.1109/TIM.2015.2390811 |
format | Article |
fullrecord | <record><control><sourceid>crossref_RIE</sourceid><recordid>TN_cdi_crossref_primary_10_1109_TIM_2015_2390811</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>7027834</ieee_id><sourcerecordid>10_1109_TIM_2015_2390811</sourcerecordid><originalsourceid>FETCH-LOGICAL-c399t-3af671b637198145f59662a81a66fc68c6e4b509d2a3cce09e62c552186bb1843</originalsourceid><addsrcrecordid>eNo9kFFLwzAUhYMoOKfvgi_5A525TZMmj1vRbbAh6HwuaXbjKmtTkk7cv3dlw6f7cr7DuR8hj8AmAEw_b5brScpATFKumQK4IiMQIk-0lOk1GTEGKtGZkLfkLsZvxlgus3xEXOGbbo-_9N1sTaBF8DHSD7R97Vu6RhMPARts-0i9o_0O6eLQmJbO_PZInQ90FtD0u2R6An7q_kjXvq17H-r2i067bl9bMzTFe3LjzD7iw-WOyefry6ZYJKu3-bKYrhLLte4TbpzMoZI8B60gE04M840CI6WzUlmJWSWY3qaGW4tMo0ytECkoWVWgMj4m7Nxrh0cCurILdWPCsQRWDp7Kk6dy8FRePJ2QpzNSI-J_PGdprnjG_wDQUWSX</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Complex Radar Cross Section Measurements of the Human Body for Breath-Activity Monitoring Applications</title><source>IEEE Xplore</source><creator>Piuzzi, Emanuele ; D'Atanasio, Paolo ; Pisa, Stefano ; Pittella, Erika ; Zambotti, Alessandro</creator><creatorcontrib>Piuzzi, Emanuele ; D'Atanasio, Paolo ; Pisa, Stefano ; Pittella, Erika ; Zambotti, Alessandro</creatorcontrib><description>An experimental setup for complex mono-static radar cross section (RCS) measurements in the 1-10-GHz-frequency band, employing a suitably modified semianechoic chamber, is presented and characterized. The foreseen application is the measurement of the complex RCS of the human body during respiratory activity, to ease the design and optimization of ultrawideband (UWB) radar systems for breath-activity monitoring. The proposed RCS test range is calibrated by means of a readily available aluminum flat panel and its performance is tested against canonical targets, evaluating uncertainty in magnitude, and phase measurements. The setup is then employed to carry out investigations on the complex RCS of a volunteer, focusing on its changes resulting from breath activity. Applying the measured RCS patterns to a specifically developed model, the feasibility of the UWB radar approach for achieving a continuous contact-less monitoring of breath activity in a subject at rest is clearly demonstrated. Finally, experimental tests of the application of the proposed radar technique to real-world scenarios are shown, and the safety of RCS measurements and UWB radar monitoring, with reference to exposure of the monitored subject to the radiated electromagnetic fields, is evaluated.</description><identifier>ISSN: 0018-9456</identifier><identifier>EISSN: 1557-9662</identifier><identifier>DOI: 10.1109/TIM.2015.2390811</identifier><identifier>CODEN: IEIMAO</identifier><language>eng</language><publisher>IEEE</publisher><subject>Anechoic chambers ; Antenna measurements ; Atmospheric measurements ; biomedical monitoring ; Calibration ; Frequency measurement ; Monitoring ; Particle measurements ; radar cross sections (RCSs) ; radiation safety ; Ultra wideband radar ; ultrawideband (UWB) radar</subject><ispartof>IEEE transactions on instrumentation and measurement, 2015-08, Vol.64 (8), p.2247-2258</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c399t-3af671b637198145f59662a81a66fc68c6e4b509d2a3cce09e62c552186bb1843</citedby><cites>FETCH-LOGICAL-c399t-3af671b637198145f59662a81a66fc68c6e4b509d2a3cce09e62c552186bb1843</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/7027834$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,777,781,793,27905,27906,54739</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/7027834$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Piuzzi, Emanuele</creatorcontrib><creatorcontrib>D'Atanasio, Paolo</creatorcontrib><creatorcontrib>Pisa, Stefano</creatorcontrib><creatorcontrib>Pittella, Erika</creatorcontrib><creatorcontrib>Zambotti, Alessandro</creatorcontrib><title>Complex Radar Cross Section Measurements of the Human Body for Breath-Activity Monitoring Applications</title><title>IEEE transactions on instrumentation and measurement</title><addtitle>TIM</addtitle><description>An experimental setup for complex mono-static radar cross section (RCS) measurements in the 1-10-GHz-frequency band, employing a suitably modified semianechoic chamber, is presented and characterized. The foreseen application is the measurement of the complex RCS of the human body during respiratory activity, to ease the design and optimization of ultrawideband (UWB) radar systems for breath-activity monitoring. The proposed RCS test range is calibrated by means of a readily available aluminum flat panel and its performance is tested against canonical targets, evaluating uncertainty in magnitude, and phase measurements. The setup is then employed to carry out investigations on the complex RCS of a volunteer, focusing on its changes resulting from breath activity. Applying the measured RCS patterns to a specifically developed model, the feasibility of the UWB radar approach for achieving a continuous contact-less monitoring of breath activity in a subject at rest is clearly demonstrated. Finally, experimental tests of the application of the proposed radar technique to real-world scenarios are shown, and the safety of RCS measurements and UWB radar monitoring, with reference to exposure of the monitored subject to the radiated electromagnetic fields, is evaluated.</description><subject>Anechoic chambers</subject><subject>Antenna measurements</subject><subject>Atmospheric measurements</subject><subject>biomedical monitoring</subject><subject>Calibration</subject><subject>Frequency measurement</subject><subject>Monitoring</subject><subject>Particle measurements</subject><subject>radar cross sections (RCSs)</subject><subject>radiation safety</subject><subject>Ultra wideband radar</subject><subject>ultrawideband (UWB) radar</subject><issn>0018-9456</issn><issn>1557-9662</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNo9kFFLwzAUhYMoOKfvgi_5A525TZMmj1vRbbAh6HwuaXbjKmtTkk7cv3dlw6f7cr7DuR8hj8AmAEw_b5brScpATFKumQK4IiMQIk-0lOk1GTEGKtGZkLfkLsZvxlgus3xEXOGbbo-_9N1sTaBF8DHSD7R97Vu6RhMPARts-0i9o_0O6eLQmJbO_PZInQ90FtD0u2R6An7q_kjXvq17H-r2i067bl9bMzTFe3LjzD7iw-WOyefry6ZYJKu3-bKYrhLLte4TbpzMoZI8B60gE04M840CI6WzUlmJWSWY3qaGW4tMo0ytECkoWVWgMj4m7Nxrh0cCurILdWPCsQRWDp7Kk6dy8FRePJ2QpzNSI-J_PGdprnjG_wDQUWSX</recordid><startdate>20150801</startdate><enddate>20150801</enddate><creator>Piuzzi, Emanuele</creator><creator>D'Atanasio, Paolo</creator><creator>Pisa, Stefano</creator><creator>Pittella, Erika</creator><creator>Zambotti, Alessandro</creator><general>IEEE</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20150801</creationdate><title>Complex Radar Cross Section Measurements of the Human Body for Breath-Activity Monitoring Applications</title><author>Piuzzi, Emanuele ; D'Atanasio, Paolo ; Pisa, Stefano ; Pittella, Erika ; Zambotti, Alessandro</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c399t-3af671b637198145f59662a81a66fc68c6e4b509d2a3cce09e62c552186bb1843</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Anechoic chambers</topic><topic>Antenna measurements</topic><topic>Atmospheric measurements</topic><topic>biomedical monitoring</topic><topic>Calibration</topic><topic>Frequency measurement</topic><topic>Monitoring</topic><topic>Particle measurements</topic><topic>radar cross sections (RCSs)</topic><topic>radiation safety</topic><topic>Ultra wideband radar</topic><topic>ultrawideband (UWB) radar</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Piuzzi, Emanuele</creatorcontrib><creatorcontrib>D'Atanasio, Paolo</creatorcontrib><creatorcontrib>Pisa, Stefano</creatorcontrib><creatorcontrib>Pittella, Erika</creatorcontrib><creatorcontrib>Zambotti, Alessandro</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998–Present</collection><collection>IEEE Xplore</collection><collection>CrossRef</collection><jtitle>IEEE transactions on instrumentation and measurement</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Piuzzi, Emanuele</au><au>D'Atanasio, Paolo</au><au>Pisa, Stefano</au><au>Pittella, Erika</au><au>Zambotti, Alessandro</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Complex Radar Cross Section Measurements of the Human Body for Breath-Activity Monitoring Applications</atitle><jtitle>IEEE transactions on instrumentation and measurement</jtitle><stitle>TIM</stitle><date>2015-08-01</date><risdate>2015</risdate><volume>64</volume><issue>8</issue><spage>2247</spage><epage>2258</epage><pages>2247-2258</pages><issn>0018-9456</issn><eissn>1557-9662</eissn><coden>IEIMAO</coden><abstract>An experimental setup for complex mono-static radar cross section (RCS) measurements in the 1-10-GHz-frequency band, employing a suitably modified semianechoic chamber, is presented and characterized. The foreseen application is the measurement of the complex RCS of the human body during respiratory activity, to ease the design and optimization of ultrawideband (UWB) radar systems for breath-activity monitoring. The proposed RCS test range is calibrated by means of a readily available aluminum flat panel and its performance is tested against canonical targets, evaluating uncertainty in magnitude, and phase measurements. The setup is then employed to carry out investigations on the complex RCS of a volunteer, focusing on its changes resulting from breath activity. Applying the measured RCS patterns to a specifically developed model, the feasibility of the UWB radar approach for achieving a continuous contact-less monitoring of breath activity in a subject at rest is clearly demonstrated. Finally, experimental tests of the application of the proposed radar technique to real-world scenarios are shown, and the safety of RCS measurements and UWB radar monitoring, with reference to exposure of the monitored subject to the radiated electromagnetic fields, is evaluated.</abstract><pub>IEEE</pub><doi>10.1109/TIM.2015.2390811</doi><tpages>12</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 0018-9456 |
ispartof | IEEE transactions on instrumentation and measurement, 2015-08, Vol.64 (8), p.2247-2258 |
issn | 0018-9456 1557-9662 |
language | eng |
recordid | cdi_crossref_primary_10_1109_TIM_2015_2390811 |
source | IEEE Xplore |
subjects | Anechoic chambers Antenna measurements Atmospheric measurements biomedical monitoring Calibration Frequency measurement Monitoring Particle measurements radar cross sections (RCSs) radiation safety Ultra wideband radar ultrawideband (UWB) radar |
title | Complex Radar Cross Section Measurements of the Human Body for Breath-Activity Monitoring Applications |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-17T19%3A20%3A49IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Complex%20Radar%20Cross%20Section%20Measurements%20of%20the%20Human%20Body%20for%20Breath-Activity%20Monitoring%20Applications&rft.jtitle=IEEE%20transactions%20on%20instrumentation%20and%20measurement&rft.au=Piuzzi,%20Emanuele&rft.date=2015-08-01&rft.volume=64&rft.issue=8&rft.spage=2247&rft.epage=2258&rft.pages=2247-2258&rft.issn=0018-9456&rft.eissn=1557-9662&rft.coden=IEIMAO&rft_id=info:doi/10.1109/TIM.2015.2390811&rft_dat=%3Ccrossref_RIE%3E10_1109_TIM_2015_2390811%3C/crossref_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=7027834&rfr_iscdi=true |