A Multistep Approach for Accurate Permittivity Measurements of Liquids Using a Transmission Line Method

High-precision permittivity measurements of liquids are essential for specifying the specific absorption rate (SAR) of radio-frequency power absorbed by the human tissue. At Van Swinden Laboratorium (VSL), a commercial unit is used for these measurements, which uses a combination of transmission and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on instrumentation and measurement 2011-07, Vol.60 (7), p.2267-2274
Hauptverfasser: Dongsheng Zhao, Rietveld, G, Teunisse, G M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2274
container_issue 7
container_start_page 2267
container_title IEEE transactions on instrumentation and measurement
container_volume 60
creator Dongsheng Zhao
Rietveld, G
Teunisse, G M
description High-precision permittivity measurements of liquids are essential for specifying the specific absorption rate (SAR) of radio-frequency power absorbed by the human tissue. At Van Swinden Laboratorium (VSL), a commercial unit is used for these measurements, which uses a combination of transmission and reflection methods. The permittivity of unknown liquids is derived from the measured different scattering parameters of a transverse electromagnetic cell when the cell is empty and when it is filled with liquid. The flat slab structure of the cell makes it convenient for liquid filling and cleaning. The method is an efficient complementary approach for permittivity measurements compared with more complex setups in other national metrology institutes, but for reaching a low uncertainty, some inherent disadvantages need to be overcome. In this paper, a multistep approach is proposed using a combination of curve fitting, nonlinear progressive technique, and improved transmission line models in order to improve the uncertainty of the permittivity measurements. This approach is applicable even without a priori knowledge of the liquid properties. Using this approach, the useful frequency range of the commercial unit is successfully extended from 200 MHz-3 GHz to at least 100 MHz-4 GHz, and the accuracy is significantly improved to the level where it becomes comparable to more primary methods. The results obtained with this new method agree very well with the reference data from the literature.
doi_str_mv 10.1109/TIM.2010.2096930
format Article
fullrecord <record><control><sourceid>proquest_RIE</sourceid><recordid>TN_cdi_crossref_primary_10_1109_TIM_2010_2096930</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>5676208</ieee_id><sourcerecordid>889406160</sourcerecordid><originalsourceid>FETCH-LOGICAL-c322t-58dc6a66c6b8c48272010e566b8359c237c98e6395e7416e8aeb1504a29b14543</originalsourceid><addsrcrecordid>eNpdkM1LAzEQxYMoWKt3wUvw4ml1kt1kk-MifkGLHtpzSNNpG2l31yQr9L83peLB0zDM7w3vPUKuGdwzBvph9ja955A3DlrqEk7IiAlRF1pKfkpGAEwVuhLynFzE-AkAtazqEVk3dDpsk48Je9r0feis29BVF2jj3BBsQvqBYedT8t8-7ekUbRwC7rBNkXYrOvFfg19GOo--XVNLZ8G2cedj9F2bjy1mRdp0y0tytrLbiFe_c0zmz0-zx9di8v7y9thMCldyngqhlk5aKZ1cKFcpXh8ioZB5LYV2vKydVihLLbCumERlccEEVJbrBatEVY7J3fFvTvI1YEwmm3G43doWuyEapXQFkknI5O0_8rMbQpvNGVWDzhwTGYIj5EIXY8CV6YPf2bA3DMyhd5N7NweT5rf3LLk5Sjwi_uFC1pKDKn8ADIB9zQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>870989415</pqid></control><display><type>article</type><title>A Multistep Approach for Accurate Permittivity Measurements of Liquids Using a Transmission Line Method</title><source>IEEE Electronic Library (IEL)</source><creator>Dongsheng Zhao ; Rietveld, G ; Teunisse, G M</creator><creatorcontrib>Dongsheng Zhao ; Rietveld, G ; Teunisse, G M</creatorcontrib><description>High-precision permittivity measurements of liquids are essential for specifying the specific absorption rate (SAR) of radio-frequency power absorbed by the human tissue. At Van Swinden Laboratorium (VSL), a commercial unit is used for these measurements, which uses a combination of transmission and reflection methods. The permittivity of unknown liquids is derived from the measured different scattering parameters of a transverse electromagnetic cell when the cell is empty and when it is filled with liquid. The flat slab structure of the cell makes it convenient for liquid filling and cleaning. The method is an efficient complementary approach for permittivity measurements compared with more complex setups in other national metrology institutes, but for reaching a low uncertainty, some inherent disadvantages need to be overcome. In this paper, a multistep approach is proposed using a combination of curve fitting, nonlinear progressive technique, and improved transmission line models in order to improve the uncertainty of the permittivity measurements. This approach is applicable even without a priori knowledge of the liquid properties. Using this approach, the useful frequency range of the commercial unit is successfully extended from 200 MHz-3 GHz to at least 100 MHz-4 GHz, and the accuracy is significantly improved to the level where it becomes comparable to more primary methods. The results obtained with this new method agree very well with the reference data from the literature.</description><identifier>ISSN: 0018-9456</identifier><identifier>EISSN: 1557-9662</identifier><identifier>DOI: 10.1109/TIM.2010.2096930</identifier><identifier>CODEN: IEIMAO</identifier><language>eng</language><publisher>New York: IEEE</publisher><subject>Curve fitting ; Dielectric constant ; Impedance ; Instrumentation ; Liquids ; Mathematical models ; mean square parameter methods ; Permittivity ; Permittivity measurement ; scattering parameter ; Slabs ; specific absorption rate (SAR) ; Studies ; Synthetic aperture radar ; TEM cells ; Transmission line measurements ; transmission line theory ; Transmission lines ; Uncertainty ; vector network analyzer (VNA)</subject><ispartof>IEEE transactions on instrumentation and measurement, 2011-07, Vol.60 (7), p.2267-2274</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) Jul 2011</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c322t-58dc6a66c6b8c48272010e566b8359c237c98e6395e7416e8aeb1504a29b14543</citedby><cites>FETCH-LOGICAL-c322t-58dc6a66c6b8c48272010e566b8359c237c98e6395e7416e8aeb1504a29b14543</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/5676208$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,780,784,796,27924,27925,54758</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/5676208$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Dongsheng Zhao</creatorcontrib><creatorcontrib>Rietveld, G</creatorcontrib><creatorcontrib>Teunisse, G M</creatorcontrib><title>A Multistep Approach for Accurate Permittivity Measurements of Liquids Using a Transmission Line Method</title><title>IEEE transactions on instrumentation and measurement</title><addtitle>TIM</addtitle><description>High-precision permittivity measurements of liquids are essential for specifying the specific absorption rate (SAR) of radio-frequency power absorbed by the human tissue. At Van Swinden Laboratorium (VSL), a commercial unit is used for these measurements, which uses a combination of transmission and reflection methods. The permittivity of unknown liquids is derived from the measured different scattering parameters of a transverse electromagnetic cell when the cell is empty and when it is filled with liquid. The flat slab structure of the cell makes it convenient for liquid filling and cleaning. The method is an efficient complementary approach for permittivity measurements compared with more complex setups in other national metrology institutes, but for reaching a low uncertainty, some inherent disadvantages need to be overcome. In this paper, a multistep approach is proposed using a combination of curve fitting, nonlinear progressive technique, and improved transmission line models in order to improve the uncertainty of the permittivity measurements. This approach is applicable even without a priori knowledge of the liquid properties. Using this approach, the useful frequency range of the commercial unit is successfully extended from 200 MHz-3 GHz to at least 100 MHz-4 GHz, and the accuracy is significantly improved to the level where it becomes comparable to more primary methods. The results obtained with this new method agree very well with the reference data from the literature.</description><subject>Curve fitting</subject><subject>Dielectric constant</subject><subject>Impedance</subject><subject>Instrumentation</subject><subject>Liquids</subject><subject>Mathematical models</subject><subject>mean square parameter methods</subject><subject>Permittivity</subject><subject>Permittivity measurement</subject><subject>scattering parameter</subject><subject>Slabs</subject><subject>specific absorption rate (SAR)</subject><subject>Studies</subject><subject>Synthetic aperture radar</subject><subject>TEM cells</subject><subject>Transmission line measurements</subject><subject>transmission line theory</subject><subject>Transmission lines</subject><subject>Uncertainty</subject><subject>vector network analyzer (VNA)</subject><issn>0018-9456</issn><issn>1557-9662</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNpdkM1LAzEQxYMoWKt3wUvw4ml1kt1kk-MifkGLHtpzSNNpG2l31yQr9L83peLB0zDM7w3vPUKuGdwzBvph9ja955A3DlrqEk7IiAlRF1pKfkpGAEwVuhLynFzE-AkAtazqEVk3dDpsk48Je9r0feis29BVF2jj3BBsQvqBYedT8t8-7ekUbRwC7rBNkXYrOvFfg19GOo--XVNLZ8G2cedj9F2bjy1mRdp0y0tytrLbiFe_c0zmz0-zx9di8v7y9thMCldyngqhlk5aKZ1cKFcpXh8ioZB5LYV2vKydVihLLbCumERlccEEVJbrBatEVY7J3fFvTvI1YEwmm3G43doWuyEapXQFkknI5O0_8rMbQpvNGVWDzhwTGYIj5EIXY8CV6YPf2bA3DMyhd5N7NweT5rf3LLk5Sjwi_uFC1pKDKn8ADIB9zQ</recordid><startdate>201107</startdate><enddate>201107</enddate><creator>Dongsheng Zhao</creator><creator>Rietveld, G</creator><creator>Teunisse, G M</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope><scope>F28</scope><scope>FR3</scope></search><sort><creationdate>201107</creationdate><title>A Multistep Approach for Accurate Permittivity Measurements of Liquids Using a Transmission Line Method</title><author>Dongsheng Zhao ; Rietveld, G ; Teunisse, G M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c322t-58dc6a66c6b8c48272010e566b8359c237c98e6395e7416e8aeb1504a29b14543</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Curve fitting</topic><topic>Dielectric constant</topic><topic>Impedance</topic><topic>Instrumentation</topic><topic>Liquids</topic><topic>Mathematical models</topic><topic>mean square parameter methods</topic><topic>Permittivity</topic><topic>Permittivity measurement</topic><topic>scattering parameter</topic><topic>Slabs</topic><topic>specific absorption rate (SAR)</topic><topic>Studies</topic><topic>Synthetic aperture radar</topic><topic>TEM cells</topic><topic>Transmission line measurements</topic><topic>transmission line theory</topic><topic>Transmission lines</topic><topic>Uncertainty</topic><topic>vector network analyzer (VNA)</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Dongsheng Zhao</creatorcontrib><creatorcontrib>Rietveld, G</creatorcontrib><creatorcontrib>Teunisse, G M</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><jtitle>IEEE transactions on instrumentation and measurement</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Dongsheng Zhao</au><au>Rietveld, G</au><au>Teunisse, G M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Multistep Approach for Accurate Permittivity Measurements of Liquids Using a Transmission Line Method</atitle><jtitle>IEEE transactions on instrumentation and measurement</jtitle><stitle>TIM</stitle><date>2011-07</date><risdate>2011</risdate><volume>60</volume><issue>7</issue><spage>2267</spage><epage>2274</epage><pages>2267-2274</pages><issn>0018-9456</issn><eissn>1557-9662</eissn><coden>IEIMAO</coden><abstract>High-precision permittivity measurements of liquids are essential for specifying the specific absorption rate (SAR) of radio-frequency power absorbed by the human tissue. At Van Swinden Laboratorium (VSL), a commercial unit is used for these measurements, which uses a combination of transmission and reflection methods. The permittivity of unknown liquids is derived from the measured different scattering parameters of a transverse electromagnetic cell when the cell is empty and when it is filled with liquid. The flat slab structure of the cell makes it convenient for liquid filling and cleaning. The method is an efficient complementary approach for permittivity measurements compared with more complex setups in other national metrology institutes, but for reaching a low uncertainty, some inherent disadvantages need to be overcome. In this paper, a multistep approach is proposed using a combination of curve fitting, nonlinear progressive technique, and improved transmission line models in order to improve the uncertainty of the permittivity measurements. This approach is applicable even without a priori knowledge of the liquid properties. Using this approach, the useful frequency range of the commercial unit is successfully extended from 200 MHz-3 GHz to at least 100 MHz-4 GHz, and the accuracy is significantly improved to the level where it becomes comparable to more primary methods. The results obtained with this new method agree very well with the reference data from the literature.</abstract><cop>New York</cop><pub>IEEE</pub><doi>10.1109/TIM.2010.2096930</doi><tpages>8</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 0018-9456
ispartof IEEE transactions on instrumentation and measurement, 2011-07, Vol.60 (7), p.2267-2274
issn 0018-9456
1557-9662
language eng
recordid cdi_crossref_primary_10_1109_TIM_2010_2096930
source IEEE Electronic Library (IEL)
subjects Curve fitting
Dielectric constant
Impedance
Instrumentation
Liquids
Mathematical models
mean square parameter methods
Permittivity
Permittivity measurement
scattering parameter
Slabs
specific absorption rate (SAR)
Studies
Synthetic aperture radar
TEM cells
Transmission line measurements
transmission line theory
Transmission lines
Uncertainty
vector network analyzer (VNA)
title A Multistep Approach for Accurate Permittivity Measurements of Liquids Using a Transmission Line Method
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T04%3A05%3A03IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Multistep%20Approach%20for%20Accurate%20Permittivity%20Measurements%20of%20Liquids%20Using%20a%20Transmission%20Line%20Method&rft.jtitle=IEEE%20transactions%20on%20instrumentation%20and%20measurement&rft.au=Dongsheng%20Zhao&rft.date=2011-07&rft.volume=60&rft.issue=7&rft.spage=2267&rft.epage=2274&rft.pages=2267-2274&rft.issn=0018-9456&rft.eissn=1557-9662&rft.coden=IEIMAO&rft_id=info:doi/10.1109/TIM.2010.2096930&rft_dat=%3Cproquest_RIE%3E889406160%3C/proquest_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=870989415&rft_id=info:pmid/&rft_ieee_id=5676208&rfr_iscdi=true