Analysis of Errors in ToF Range Imaging With Dual-Frequency Modulation

Range imaging is a technology that utilizes an amplitude-modulated light source and gain-modulated image sensor to simultaneously produce distance and intensity data for all pixels of the sensor. The precision of such a system is, in part, dependent on the modulation frequency. There is typically a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on instrumentation and measurement 2011-05, Vol.60 (5), p.1861-1868
Hauptverfasser: Jongenelen, A P P, Bailey, D G, Payne, A D, Dorrington, A A, Carnegie, D A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1868
container_issue 5
container_start_page 1861
container_title IEEE transactions on instrumentation and measurement
container_volume 60
creator Jongenelen, A P P
Bailey, D G
Payne, A D
Dorrington, A A
Carnegie, D A
description Range imaging is a technology that utilizes an amplitude-modulated light source and gain-modulated image sensor to simultaneously produce distance and intensity data for all pixels of the sensor. The precision of such a system is, in part, dependent on the modulation frequency. There is typically a tradeoff between precision and maximum unambiguous range. Research has shown that, by taking two measurements at different modulation frequencies, the unambiguous range can be extended without compromising distance precision. In this paper, we present an efficient method for combining two distance measurements obtained using different modulation frequencies. The behavior of the method in the presence of noise has been investigated to determine the expected error rate. In addition, we make use of the signal amplitude to improve the precision of the combined distance measurement. Simulated results compare well to actual data obtained using a system based on the PMD19k range image sensor.
doi_str_mv 10.1109/TIM.2010.2089190
format Article
fullrecord <record><control><sourceid>proquest_RIE</sourceid><recordid>TN_cdi_crossref_primary_10_1109_TIM_2010_2089190</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>5732688</ieee_id><sourcerecordid>1671230193</sourcerecordid><originalsourceid>FETCH-LOGICAL-c323t-fdb4dbbe41298b2ec192c5c6a069b83e98fb1c2e8a1ab65104b6e8aea7bc2a9a3</originalsourceid><addsrcrecordid>eNpdkEFLAzEQRoMoWKt3wUvw5GXrJNnNJsdSu1poEaTiMSRptqZsNzXpHvrv3dLiwdPwwfuGmYfQPYERISCfl7PFiEKfKAhJJFygASmKMpOc00s0ACAik3nBr9FNShsAKHleDlA1bnVzSD7hUONpjCEm7Fu8DBX-0O3a4dlWr327xl9-_41fOt1kVXQ_nWvtAS_Cqmv03of2Fl3Vuknu7jyH6LOaLidv2fz9dTYZzzPLKNtn9crkK2NcTqgUhjpLJLWF5Rq4NII5KWpDLHVCE214QSA3vA9Ol8ZSLTUboqfT3l0M_RFpr7Y-Wdc0unWhS4rwklAGRLIeffyHbkIX-2-TEhxYUUJOewhOkI0hpehqtYt-q-NBEVBHr6r3qo5e1dlrX3k4Vbxz7g8vSka5EOwXqCxzEw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>860357042</pqid></control><display><type>article</type><title>Analysis of Errors in ToF Range Imaging With Dual-Frequency Modulation</title><source>IEEE Electronic Library (IEL)</source><creator>Jongenelen, A P P ; Bailey, D G ; Payne, A D ; Dorrington, A A ; Carnegie, D A</creator><creatorcontrib>Jongenelen, A P P ; Bailey, D G ; Payne, A D ; Dorrington, A A ; Carnegie, D A</creatorcontrib><description>Range imaging is a technology that utilizes an amplitude-modulated light source and gain-modulated image sensor to simultaneously produce distance and intensity data for all pixels of the sensor. The precision of such a system is, in part, dependent on the modulation frequency. There is typically a tradeoff between precision and maximum unambiguous range. Research has shown that, by taking two measurements at different modulation frequencies, the unambiguous range can be extended without compromising distance precision. In this paper, we present an efficient method for combining two distance measurements obtained using different modulation frequencies. The behavior of the method in the presence of noise has been investigated to determine the expected error rate. In addition, we make use of the signal amplitude to improve the precision of the combined distance measurement. Simulated results compare well to actual data obtained using a system based on the PMD19k range image sensor.</description><identifier>ISSN: 0018-9456</identifier><identifier>EISSN: 1557-9662</identifier><identifier>DOI: 10.1109/TIM.2010.2089190</identifier><identifier>CODEN: IEIMAO</identifier><language>eng</language><publisher>New York: IEEE</publisher><subject>3-D camera ; Ambiguity ; Digital cameras ; Error analysis ; Frequency modulation ; image sensor ; Imaging ; Instrumentation ; Modulation ; Noise ; Phase measurement ; Pixels ; range imaging ; Sensors ; Simulation ; Studies ; Time frequency analysis ; time of flight (ToF)</subject><ispartof>IEEE transactions on instrumentation and measurement, 2011-05, Vol.60 (5), p.1861-1868</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) May 2011</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c323t-fdb4dbbe41298b2ec192c5c6a069b83e98fb1c2e8a1ab65104b6e8aea7bc2a9a3</citedby><cites>FETCH-LOGICAL-c323t-fdb4dbbe41298b2ec192c5c6a069b83e98fb1c2e8a1ab65104b6e8aea7bc2a9a3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/5732688$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,776,780,792,27901,27902,54733</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/5732688$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Jongenelen, A P P</creatorcontrib><creatorcontrib>Bailey, D G</creatorcontrib><creatorcontrib>Payne, A D</creatorcontrib><creatorcontrib>Dorrington, A A</creatorcontrib><creatorcontrib>Carnegie, D A</creatorcontrib><title>Analysis of Errors in ToF Range Imaging With Dual-Frequency Modulation</title><title>IEEE transactions on instrumentation and measurement</title><addtitle>TIM</addtitle><description>Range imaging is a technology that utilizes an amplitude-modulated light source and gain-modulated image sensor to simultaneously produce distance and intensity data for all pixels of the sensor. The precision of such a system is, in part, dependent on the modulation frequency. There is typically a tradeoff between precision and maximum unambiguous range. Research has shown that, by taking two measurements at different modulation frequencies, the unambiguous range can be extended without compromising distance precision. In this paper, we present an efficient method for combining two distance measurements obtained using different modulation frequencies. The behavior of the method in the presence of noise has been investigated to determine the expected error rate. In addition, we make use of the signal amplitude to improve the precision of the combined distance measurement. Simulated results compare well to actual data obtained using a system based on the PMD19k range image sensor.</description><subject>3-D camera</subject><subject>Ambiguity</subject><subject>Digital cameras</subject><subject>Error analysis</subject><subject>Frequency modulation</subject><subject>image sensor</subject><subject>Imaging</subject><subject>Instrumentation</subject><subject>Modulation</subject><subject>Noise</subject><subject>Phase measurement</subject><subject>Pixels</subject><subject>range imaging</subject><subject>Sensors</subject><subject>Simulation</subject><subject>Studies</subject><subject>Time frequency analysis</subject><subject>time of flight (ToF)</subject><issn>0018-9456</issn><issn>1557-9662</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNpdkEFLAzEQRoMoWKt3wUvw5GXrJNnNJsdSu1poEaTiMSRptqZsNzXpHvrv3dLiwdPwwfuGmYfQPYERISCfl7PFiEKfKAhJJFygASmKMpOc00s0ACAik3nBr9FNShsAKHleDlA1bnVzSD7hUONpjCEm7Fu8DBX-0O3a4dlWr327xl9-_41fOt1kVXQ_nWvtAS_Cqmv03of2Fl3Vuknu7jyH6LOaLidv2fz9dTYZzzPLKNtn9crkK2NcTqgUhjpLJLWF5Rq4NII5KWpDLHVCE214QSA3vA9Ol8ZSLTUboqfT3l0M_RFpr7Y-Wdc0unWhS4rwklAGRLIeffyHbkIX-2-TEhxYUUJOewhOkI0hpehqtYt-q-NBEVBHr6r3qo5e1dlrX3k4Vbxz7g8vSka5EOwXqCxzEw</recordid><startdate>201105</startdate><enddate>201105</enddate><creator>Jongenelen, A P P</creator><creator>Bailey, D G</creator><creator>Payne, A D</creator><creator>Dorrington, A A</creator><creator>Carnegie, D A</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope><scope>F28</scope><scope>FR3</scope></search><sort><creationdate>201105</creationdate><title>Analysis of Errors in ToF Range Imaging With Dual-Frequency Modulation</title><author>Jongenelen, A P P ; Bailey, D G ; Payne, A D ; Dorrington, A A ; Carnegie, D A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c323t-fdb4dbbe41298b2ec192c5c6a069b83e98fb1c2e8a1ab65104b6e8aea7bc2a9a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>3-D camera</topic><topic>Ambiguity</topic><topic>Digital cameras</topic><topic>Error analysis</topic><topic>Frequency modulation</topic><topic>image sensor</topic><topic>Imaging</topic><topic>Instrumentation</topic><topic>Modulation</topic><topic>Noise</topic><topic>Phase measurement</topic><topic>Pixels</topic><topic>range imaging</topic><topic>Sensors</topic><topic>Simulation</topic><topic>Studies</topic><topic>Time frequency analysis</topic><topic>time of flight (ToF)</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Jongenelen, A P P</creatorcontrib><creatorcontrib>Bailey, D G</creatorcontrib><creatorcontrib>Payne, A D</creatorcontrib><creatorcontrib>Dorrington, A A</creatorcontrib><creatorcontrib>Carnegie, D A</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><jtitle>IEEE transactions on instrumentation and measurement</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Jongenelen, A P P</au><au>Bailey, D G</au><au>Payne, A D</au><au>Dorrington, A A</au><au>Carnegie, D A</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Analysis of Errors in ToF Range Imaging With Dual-Frequency Modulation</atitle><jtitle>IEEE transactions on instrumentation and measurement</jtitle><stitle>TIM</stitle><date>2011-05</date><risdate>2011</risdate><volume>60</volume><issue>5</issue><spage>1861</spage><epage>1868</epage><pages>1861-1868</pages><issn>0018-9456</issn><eissn>1557-9662</eissn><coden>IEIMAO</coden><abstract>Range imaging is a technology that utilizes an amplitude-modulated light source and gain-modulated image sensor to simultaneously produce distance and intensity data for all pixels of the sensor. The precision of such a system is, in part, dependent on the modulation frequency. There is typically a tradeoff between precision and maximum unambiguous range. Research has shown that, by taking two measurements at different modulation frequencies, the unambiguous range can be extended without compromising distance precision. In this paper, we present an efficient method for combining two distance measurements obtained using different modulation frequencies. The behavior of the method in the presence of noise has been investigated to determine the expected error rate. In addition, we make use of the signal amplitude to improve the precision of the combined distance measurement. Simulated results compare well to actual data obtained using a system based on the PMD19k range image sensor.</abstract><cop>New York</cop><pub>IEEE</pub><doi>10.1109/TIM.2010.2089190</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 0018-9456
ispartof IEEE transactions on instrumentation and measurement, 2011-05, Vol.60 (5), p.1861-1868
issn 0018-9456
1557-9662
language eng
recordid cdi_crossref_primary_10_1109_TIM_2010_2089190
source IEEE Electronic Library (IEL)
subjects 3-D camera
Ambiguity
Digital cameras
Error analysis
Frequency modulation
image sensor
Imaging
Instrumentation
Modulation
Noise
Phase measurement
Pixels
range imaging
Sensors
Simulation
Studies
Time frequency analysis
time of flight (ToF)
title Analysis of Errors in ToF Range Imaging With Dual-Frequency Modulation
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-14T19%3A22%3A55IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Analysis%20of%20Errors%20in%20ToF%20Range%20Imaging%20With%20Dual-Frequency%20Modulation&rft.jtitle=IEEE%20transactions%20on%20instrumentation%20and%20measurement&rft.au=Jongenelen,%20A%20P%20P&rft.date=2011-05&rft.volume=60&rft.issue=5&rft.spage=1861&rft.epage=1868&rft.pages=1861-1868&rft.issn=0018-9456&rft.eissn=1557-9662&rft.coden=IEIMAO&rft_id=info:doi/10.1109/TIM.2010.2089190&rft_dat=%3Cproquest_RIE%3E1671230193%3C/proquest_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=860357042&rft_id=info:pmid/&rft_ieee_id=5732688&rfr_iscdi=true