Identification and Localization of Array Faults With Optimized Placement of Voltage Sensors in a PV System

The traditional protection devices installed in photovoltaic (PV) arrays generally detect line-line (LL) and line-ground (LG) faults when the fault current magnitude exceeds its threshold value defined by various international standards. However, the magnitude of fault current is greatly reduced, du...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on industrial electronics (1982) 2021-07, Vol.68 (7), p.5921-5931
Hauptverfasser: Kumar, B. Pradeep, Pillai, Dhanup S., Rajasekar, N., Chakkarapani, Manickam, Ilango, G. Saravana
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 5931
container_issue 7
container_start_page 5921
container_title IEEE transactions on industrial electronics (1982)
container_volume 68
creator Kumar, B. Pradeep
Pillai, Dhanup S.
Rajasekar, N.
Chakkarapani, Manickam
Ilango, G. Saravana
description The traditional protection devices installed in photovoltaic (PV) arrays generally detect line-line (LL) and line-ground (LG) faults when the fault current magnitude exceeds its threshold value defined by various international standards. However, the magnitude of fault current is greatly reduced, due to low irradiance levels, active maximum power point tracker, location of fault, minimal fault mismatch, and presence of blocking diodes. Consequently, majority of such faults remain obscured even when the irradiance reaches to a higher level and thereby constitute to reliability issues and severe fire risks. Therefore, both timely fault detection and localization become highly obligatory for sustainable power generation and safety. Thus, this article proposes a new, robust, and efficient fault localization method based on the principle of differential voltage measurement between PV modules of adjacent strings. For accomplishing this task, a new optimized voltage sensor arrangement with minimal number of sensors is followed. Moreover, the proposed convention 1) is proficient to detect any LL/LG faults independent of its detection challenges, 2) suits both grounded and floating PV systems, and 3) is compatible for systems with/without blocking diodes. For a realistic validation, testing has been performed on a small-scale grid-connected PV system and the efficacy in detecting various array faults is demonstrated via extensive investigations.
doi_str_mv 10.1109/TIE.2020.2998750
format Article
fullrecord <record><control><sourceid>proquest_RIE</sourceid><recordid>TN_cdi_crossref_primary_10_1109_TIE_2020_2998750</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>9108571</ieee_id><sourcerecordid>2505608527</sourcerecordid><originalsourceid>FETCH-LOGICAL-c291t-3b2f759e41dfb5bdf040ed1967aca46dc28db37cba11a1f34c0e0b7423cc37f3</originalsourceid><addsrcrecordid>eNo9kEFrwjAUgMPYYM7tPtglsHPdS9o0zVHEbYKgoLhjSdNki7SNS-JBf_0qlZ0ePL73PfgQeiYwIQTE23Yxn1CgMKFCFJzBDRoRxngiRFbcohFQXiQAWX6PHkLYA5CMETZC-0Wtu2iNVTJa12HZ1XjplGzseVg4g6feyxN-l8cmBvxl4w9eHaJt7VnXeN1IpdtecQF3ronyW-ON7oLzAdveh9c7vDmFqNtHdGdkE_TTdY7R9n2-nX0my9XHYjZdJooKEpO0ooYzoTNSm4pVtYEMdE1EzqWSWV4rWtRVylUlCZHEpJkCDRXPaKpUyk06Rq-D9uDd71GHWO7d0Xf9x5IyYDkUjPKegoFS3oXgtSkP3rbSn0oC5SVo2QctL0HLa9D-5GU4sVrrf1yQXshJ-gcUyXKC</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2505608527</pqid></control><display><type>article</type><title>Identification and Localization of Array Faults With Optimized Placement of Voltage Sensors in a PV System</title><source>IEEE Electronic Library (IEL)</source><creator>Kumar, B. Pradeep ; Pillai, Dhanup S. ; Rajasekar, N. ; Chakkarapani, Manickam ; Ilango, G. Saravana</creator><creatorcontrib>Kumar, B. Pradeep ; Pillai, Dhanup S. ; Rajasekar, N. ; Chakkarapani, Manickam ; Ilango, G. Saravana</creatorcontrib><description>The traditional protection devices installed in photovoltaic (PV) arrays generally detect line-line (LL) and line-ground (LG) faults when the fault current magnitude exceeds its threshold value defined by various international standards. However, the magnitude of fault current is greatly reduced, due to low irradiance levels, active maximum power point tracker, location of fault, minimal fault mismatch, and presence of blocking diodes. Consequently, majority of such faults remain obscured even when the irradiance reaches to a higher level and thereby constitute to reliability issues and severe fire risks. Therefore, both timely fault detection and localization become highly obligatory for sustainable power generation and safety. Thus, this article proposes a new, robust, and efficient fault localization method based on the principle of differential voltage measurement between PV modules of adjacent strings. For accomplishing this task, a new optimized voltage sensor arrangement with minimal number of sensors is followed. Moreover, the proposed convention 1) is proficient to detect any LL/LG faults independent of its detection challenges, 2) suits both grounded and floating PV systems, and 3) is compatible for systems with/without blocking diodes. For a realistic validation, testing has been performed on a small-scale grid-connected PV system and the efficacy in detecting various array faults is demonstrated via extensive investigations.</description><identifier>ISSN: 0278-0046</identifier><identifier>EISSN: 1557-9948</identifier><identifier>DOI: 10.1109/TIE.2020.2998750</identifier><identifier>CODEN: ITIED6</identifier><language>eng</language><publisher>New York: IEEE</publisher><subject>Circuit faults ; DH-HEMTs ; Differential voltage measurement ; Electric power generation ; Electrical measurement ; Fault detection ; Fault location ; Irradiance ; LL faults ; Localization ; Localization method ; Maximum power ; open-circuit fault ; partial shading conditions ; photovoltaic array ; Photovoltaic cells ; Power generation ; Sensor arrays ; Sensor systems ; Sensors</subject><ispartof>IEEE transactions on industrial electronics (1982), 2021-07, Vol.68 (7), p.5921-5931</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2021</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c291t-3b2f759e41dfb5bdf040ed1967aca46dc28db37cba11a1f34c0e0b7423cc37f3</citedby><cites>FETCH-LOGICAL-c291t-3b2f759e41dfb5bdf040ed1967aca46dc28db37cba11a1f34c0e0b7423cc37f3</cites><orcidid>0000-0001-6386-9668 ; 0000-0002-9670-3549 ; 0000-0002-9584-1106 ; 0000-0001-6489-1736 ; 0000-0002-7916-3376</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/9108571$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,776,780,792,27901,27902,54733</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/9108571$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Kumar, B. Pradeep</creatorcontrib><creatorcontrib>Pillai, Dhanup S.</creatorcontrib><creatorcontrib>Rajasekar, N.</creatorcontrib><creatorcontrib>Chakkarapani, Manickam</creatorcontrib><creatorcontrib>Ilango, G. Saravana</creatorcontrib><title>Identification and Localization of Array Faults With Optimized Placement of Voltage Sensors in a PV System</title><title>IEEE transactions on industrial electronics (1982)</title><addtitle>TIE</addtitle><description>The traditional protection devices installed in photovoltaic (PV) arrays generally detect line-line (LL) and line-ground (LG) faults when the fault current magnitude exceeds its threshold value defined by various international standards. However, the magnitude of fault current is greatly reduced, due to low irradiance levels, active maximum power point tracker, location of fault, minimal fault mismatch, and presence of blocking diodes. Consequently, majority of such faults remain obscured even when the irradiance reaches to a higher level and thereby constitute to reliability issues and severe fire risks. Therefore, both timely fault detection and localization become highly obligatory for sustainable power generation and safety. Thus, this article proposes a new, robust, and efficient fault localization method based on the principle of differential voltage measurement between PV modules of adjacent strings. For accomplishing this task, a new optimized voltage sensor arrangement with minimal number of sensors is followed. Moreover, the proposed convention 1) is proficient to detect any LL/LG faults independent of its detection challenges, 2) suits both grounded and floating PV systems, and 3) is compatible for systems with/without blocking diodes. For a realistic validation, testing has been performed on a small-scale grid-connected PV system and the efficacy in detecting various array faults is demonstrated via extensive investigations.</description><subject>Circuit faults</subject><subject>DH-HEMTs</subject><subject>Differential voltage measurement</subject><subject>Electric power generation</subject><subject>Electrical measurement</subject><subject>Fault detection</subject><subject>Fault location</subject><subject>Irradiance</subject><subject>LL faults</subject><subject>Localization</subject><subject>Localization method</subject><subject>Maximum power</subject><subject>open-circuit fault</subject><subject>partial shading conditions</subject><subject>photovoltaic array</subject><subject>Photovoltaic cells</subject><subject>Power generation</subject><subject>Sensor arrays</subject><subject>Sensor systems</subject><subject>Sensors</subject><issn>0278-0046</issn><issn>1557-9948</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNo9kEFrwjAUgMPYYM7tPtglsHPdS9o0zVHEbYKgoLhjSdNki7SNS-JBf_0qlZ0ePL73PfgQeiYwIQTE23Yxn1CgMKFCFJzBDRoRxngiRFbcohFQXiQAWX6PHkLYA5CMETZC-0Wtu2iNVTJa12HZ1XjplGzseVg4g6feyxN-l8cmBvxl4w9eHaJt7VnXeN1IpdtecQF3ronyW-ON7oLzAdveh9c7vDmFqNtHdGdkE_TTdY7R9n2-nX0my9XHYjZdJooKEpO0ooYzoTNSm4pVtYEMdE1EzqWSWV4rWtRVylUlCZHEpJkCDRXPaKpUyk06Rq-D9uDd71GHWO7d0Xf9x5IyYDkUjPKegoFS3oXgtSkP3rbSn0oC5SVo2QctL0HLa9D-5GU4sVrrf1yQXshJ-gcUyXKC</recordid><startdate>20210701</startdate><enddate>20210701</enddate><creator>Kumar, B. Pradeep</creator><creator>Pillai, Dhanup S.</creator><creator>Rajasekar, N.</creator><creator>Chakkarapani, Manickam</creator><creator>Ilango, G. Saravana</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>8FD</scope><scope>L7M</scope><orcidid>https://orcid.org/0000-0001-6386-9668</orcidid><orcidid>https://orcid.org/0000-0002-9670-3549</orcidid><orcidid>https://orcid.org/0000-0002-9584-1106</orcidid><orcidid>https://orcid.org/0000-0001-6489-1736</orcidid><orcidid>https://orcid.org/0000-0002-7916-3376</orcidid></search><sort><creationdate>20210701</creationdate><title>Identification and Localization of Array Faults With Optimized Placement of Voltage Sensors in a PV System</title><author>Kumar, B. Pradeep ; Pillai, Dhanup S. ; Rajasekar, N. ; Chakkarapani, Manickam ; Ilango, G. Saravana</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c291t-3b2f759e41dfb5bdf040ed1967aca46dc28db37cba11a1f34c0e0b7423cc37f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Circuit faults</topic><topic>DH-HEMTs</topic><topic>Differential voltage measurement</topic><topic>Electric power generation</topic><topic>Electrical measurement</topic><topic>Fault detection</topic><topic>Fault location</topic><topic>Irradiance</topic><topic>LL faults</topic><topic>Localization</topic><topic>Localization method</topic><topic>Maximum power</topic><topic>open-circuit fault</topic><topic>partial shading conditions</topic><topic>photovoltaic array</topic><topic>Photovoltaic cells</topic><topic>Power generation</topic><topic>Sensor arrays</topic><topic>Sensor systems</topic><topic>Sensors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kumar, B. Pradeep</creatorcontrib><creatorcontrib>Pillai, Dhanup S.</creatorcontrib><creatorcontrib>Rajasekar, N.</creatorcontrib><creatorcontrib>Chakkarapani, Manickam</creatorcontrib><creatorcontrib>Ilango, G. Saravana</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>IEEE transactions on industrial electronics (1982)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Kumar, B. Pradeep</au><au>Pillai, Dhanup S.</au><au>Rajasekar, N.</au><au>Chakkarapani, Manickam</au><au>Ilango, G. Saravana</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Identification and Localization of Array Faults With Optimized Placement of Voltage Sensors in a PV System</atitle><jtitle>IEEE transactions on industrial electronics (1982)</jtitle><stitle>TIE</stitle><date>2021-07-01</date><risdate>2021</risdate><volume>68</volume><issue>7</issue><spage>5921</spage><epage>5931</epage><pages>5921-5931</pages><issn>0278-0046</issn><eissn>1557-9948</eissn><coden>ITIED6</coden><abstract>The traditional protection devices installed in photovoltaic (PV) arrays generally detect line-line (LL) and line-ground (LG) faults when the fault current magnitude exceeds its threshold value defined by various international standards. However, the magnitude of fault current is greatly reduced, due to low irradiance levels, active maximum power point tracker, location of fault, minimal fault mismatch, and presence of blocking diodes. Consequently, majority of such faults remain obscured even when the irradiance reaches to a higher level and thereby constitute to reliability issues and severe fire risks. Therefore, both timely fault detection and localization become highly obligatory for sustainable power generation and safety. Thus, this article proposes a new, robust, and efficient fault localization method based on the principle of differential voltage measurement between PV modules of adjacent strings. For accomplishing this task, a new optimized voltage sensor arrangement with minimal number of sensors is followed. Moreover, the proposed convention 1) is proficient to detect any LL/LG faults independent of its detection challenges, 2) suits both grounded and floating PV systems, and 3) is compatible for systems with/without blocking diodes. For a realistic validation, testing has been performed on a small-scale grid-connected PV system and the efficacy in detecting various array faults is demonstrated via extensive investigations.</abstract><cop>New York</cop><pub>IEEE</pub><doi>10.1109/TIE.2020.2998750</doi><tpages>11</tpages><orcidid>https://orcid.org/0000-0001-6386-9668</orcidid><orcidid>https://orcid.org/0000-0002-9670-3549</orcidid><orcidid>https://orcid.org/0000-0002-9584-1106</orcidid><orcidid>https://orcid.org/0000-0001-6489-1736</orcidid><orcidid>https://orcid.org/0000-0002-7916-3376</orcidid></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 0278-0046
ispartof IEEE transactions on industrial electronics (1982), 2021-07, Vol.68 (7), p.5921-5931
issn 0278-0046
1557-9948
language eng
recordid cdi_crossref_primary_10_1109_TIE_2020_2998750
source IEEE Electronic Library (IEL)
subjects Circuit faults
DH-HEMTs
Differential voltage measurement
Electric power generation
Electrical measurement
Fault detection
Fault location
Irradiance
LL faults
Localization
Localization method
Maximum power
open-circuit fault
partial shading conditions
photovoltaic array
Photovoltaic cells
Power generation
Sensor arrays
Sensor systems
Sensors
title Identification and Localization of Array Faults With Optimized Placement of Voltage Sensors in a PV System
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-08T01%3A23%3A58IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Identification%20and%20Localization%20of%20Array%20Faults%20With%20Optimized%20Placement%20of%20Voltage%20Sensors%20in%20a%20PV%20System&rft.jtitle=IEEE%20transactions%20on%20industrial%20electronics%20(1982)&rft.au=Kumar,%20B.%20Pradeep&rft.date=2021-07-01&rft.volume=68&rft.issue=7&rft.spage=5921&rft.epage=5931&rft.pages=5921-5931&rft.issn=0278-0046&rft.eissn=1557-9948&rft.coden=ITIED6&rft_id=info:doi/10.1109/TIE.2020.2998750&rft_dat=%3Cproquest_RIE%3E2505608527%3C/proquest_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2505608527&rft_id=info:pmid/&rft_ieee_id=9108571&rfr_iscdi=true