A Bridgeless Dual Boost Rectifier With Soft-Switching Capability and Minimized Additional Conduction Loss

A bridgeless dual boost rectifier is proposed to achieve a soft switching for power factor correction circuit. Based on the conventional bridgeless dual boost rectifier, an auxiliary circuit is employed in the proposed converter to perform zero-voltage switching of the main switches and zero-current...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on industrial electronics (1982) 2018-03, Vol.65 (3), p.2226-2233
Hauptverfasser: Jeong, Yeonho, Kim, Jae-Kuk, Moon, Gun-Woo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A bridgeless dual boost rectifier is proposed to achieve a soft switching for power factor correction circuit. Based on the conventional bridgeless dual boost rectifier, an auxiliary circuit is employed in the proposed converter to perform zero-voltage switching of the main switches and zero-current switching of the auxiliary switches. As a result, switching losses can be significantly reduced. In addition, the design guideline for the optimized turn-on time of the auxiliary switches is presented to minimize the additional conduction loss in the auxiliary circuit. The validity of the proposed converter is confirmed by the experimental results of a prototype converter with 100-240 VAC universalline input and 800-W (400 V/2 A) output.
ISSN:0278-0046
1557-9948