Constant-Frequency Peak-Ripple-Based Control of Buck Converter in CCM: Review, Unification, and Duality
The operation principles of peak current control, V 2 control, and enhanced- V 2 control of buck converter in continuous conduction mode are reviewed and compared. By the use of weight factors of inductor current and output voltage, they are unified as constant-frequency peak-ripple-based (CF-PR) an...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on industrial electronics (1982) 2014-03, Vol.61 (3), p.1280-1291 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1291 |
---|---|
container_issue | 3 |
container_start_page | 1280 |
container_title | IEEE transactions on industrial electronics (1982) |
container_volume | 61 |
creator | Zhou, Guohua Xu, Jianping Wang, Jinping |
description | The operation principles of peak current control, V 2 control, and enhanced- V 2 control of buck converter in continuous conduction mode are reviewed and compared. By the use of weight factors of inductor current and output voltage, they are unified as constant-frequency peak-ripple-based (CF-PR) analog control. It is revealed that conventional peak current control and V 2 control are two boundaries of the unified CF-PR control. The duality items between CF-PR control and constant-frequency valley-ripple-based (CF-VR) control are proposed. As the duality of CF-PR analog control, CF-VR analog control is investigated. Unified CF-PR and CF-VR digital control laws with different modulations and their stabilities are investigated in terms of the duality. Experimental results verify the theory analysis. |
doi_str_mv | 10.1109/TIE.2013.2257143 |
format | Article |
fullrecord | <record><control><sourceid>crossref_RIE</sourceid><recordid>TN_cdi_crossref_primary_10_1109_TIE_2013_2257143</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6494638</ieee_id><sourcerecordid>10_1109_TIE_2013_2257143</sourcerecordid><originalsourceid>FETCH-LOGICAL-c329t-fdbc93720177058e53bb309d99d864582e9f41449d35e1ff2d23f8e262ee1b183</originalsourceid><addsrcrecordid>eNo9kN9LwzAcxIMoOKfvgi_5A5aZn23im9ZNBxNlbM8lbb-RuNrONJvsv7djw6fj4O7gPgjdMjpmjJr75Wwy5pSJMecqZVKcoQFTKiXGSH2OBpSnmlAqk0t01XVflDKpmBqgz6xtumibSKYBfrbQlHv8AXZNFn6zqYE82Q4q3IdiaGvcOvy0LdcHv4MQIWDf4Cx7e8AL2Hn4HeFV450vbfRtM8K2qfDz1tY-7q_RhbN1BzcnHaLVdLLMXsn8_WWWPc5JKbiJxFVFaUTaH0lTqjQoURSCmsqYSidSaQ7GSSalqYQC5hyvuHAaeMIBWMG0GCJ63C1D23UBXL4J_tuGfc5ofgCV96DyA6j8BKqv3B0rHgD-44k0MhFa_AE0hmO4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Constant-Frequency Peak-Ripple-Based Control of Buck Converter in CCM: Review, Unification, and Duality</title><source>IEEE Electronic Library (IEL)</source><creator>Zhou, Guohua ; Xu, Jianping ; Wang, Jinping</creator><creatorcontrib>Zhou, Guohua ; Xu, Jianping ; Wang, Jinping</creatorcontrib><description>The operation principles of peak current control, V 2 control, and enhanced- V 2 control of buck converter in continuous conduction mode are reviewed and compared. By the use of weight factors of inductor current and output voltage, they are unified as constant-frequency peak-ripple-based (CF-PR) analog control. It is revealed that conventional peak current control and V 2 control are two boundaries of the unified CF-PR control. The duality items between CF-PR control and constant-frequency valley-ripple-based (CF-VR) control are proposed. As the duality of CF-PR analog control, CF-VR analog control is investigated. Unified CF-PR and CF-VR digital control laws with different modulations and their stabilities are investigated in terms of the duality. Experimental results verify the theory analysis.</description><identifier>ISSN: 0278-0046</identifier><identifier>EISSN: 1557-9948</identifier><identifier>DOI: 10.1109/TIE.2013.2257143</identifier><identifier>CODEN: ITIED6</identifier><language>eng</language><publisher>IEEE</publisher><subject>Buck converters ; Current control ; Current-mode control ; Digital control ; enhanced- V^{2} control ; Inductors ; pulsewidth modulation (PWM) ; ripple-based control ; Switches ; switching converter ; V^{2} control ; V^{2}C control ; Voltage control</subject><ispartof>IEEE transactions on industrial electronics (1982), 2014-03, Vol.61 (3), p.1280-1291</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c329t-fdbc93720177058e53bb309d99d864582e9f41449d35e1ff2d23f8e262ee1b183</citedby><cites>FETCH-LOGICAL-c329t-fdbc93720177058e53bb309d99d864582e9f41449d35e1ff2d23f8e262ee1b183</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6494638$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,780,784,796,27924,27925,54758</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6494638$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Zhou, Guohua</creatorcontrib><creatorcontrib>Xu, Jianping</creatorcontrib><creatorcontrib>Wang, Jinping</creatorcontrib><title>Constant-Frequency Peak-Ripple-Based Control of Buck Converter in CCM: Review, Unification, and Duality</title><title>IEEE transactions on industrial electronics (1982)</title><addtitle>TIE</addtitle><description>The operation principles of peak current control, V 2 control, and enhanced- V 2 control of buck converter in continuous conduction mode are reviewed and compared. By the use of weight factors of inductor current and output voltage, they are unified as constant-frequency peak-ripple-based (CF-PR) analog control. It is revealed that conventional peak current control and V 2 control are two boundaries of the unified CF-PR control. The duality items between CF-PR control and constant-frequency valley-ripple-based (CF-VR) control are proposed. As the duality of CF-PR analog control, CF-VR analog control is investigated. Unified CF-PR and CF-VR digital control laws with different modulations and their stabilities are investigated in terms of the duality. Experimental results verify the theory analysis.</description><subject>Buck converters</subject><subject>Current control</subject><subject>Current-mode control</subject><subject>Digital control</subject><subject>enhanced- V^{2} control</subject><subject>Inductors</subject><subject>pulsewidth modulation (PWM)</subject><subject>ripple-based control</subject><subject>Switches</subject><subject>switching converter</subject><subject>V^{2} control</subject><subject>V^{2}C control</subject><subject>Voltage control</subject><issn>0278-0046</issn><issn>1557-9948</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNo9kN9LwzAcxIMoOKfvgi_5A5aZn23im9ZNBxNlbM8lbb-RuNrONJvsv7djw6fj4O7gPgjdMjpmjJr75Wwy5pSJMecqZVKcoQFTKiXGSH2OBpSnmlAqk0t01XVflDKpmBqgz6xtumibSKYBfrbQlHv8AXZNFn6zqYE82Q4q3IdiaGvcOvy0LdcHv4MQIWDf4Cx7e8AL2Hn4HeFV450vbfRtM8K2qfDz1tY-7q_RhbN1BzcnHaLVdLLMXsn8_WWWPc5JKbiJxFVFaUTaH0lTqjQoURSCmsqYSidSaQ7GSSalqYQC5hyvuHAaeMIBWMG0GCJ63C1D23UBXL4J_tuGfc5ofgCV96DyA6j8BKqv3B0rHgD-44k0MhFa_AE0hmO4</recordid><startdate>20140301</startdate><enddate>20140301</enddate><creator>Zhou, Guohua</creator><creator>Xu, Jianping</creator><creator>Wang, Jinping</creator><general>IEEE</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20140301</creationdate><title>Constant-Frequency Peak-Ripple-Based Control of Buck Converter in CCM: Review, Unification, and Duality</title><author>Zhou, Guohua ; Xu, Jianping ; Wang, Jinping</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c329t-fdbc93720177058e53bb309d99d864582e9f41449d35e1ff2d23f8e262ee1b183</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Buck converters</topic><topic>Current control</topic><topic>Current-mode control</topic><topic>Digital control</topic><topic>enhanced- V^{2} control</topic><topic>Inductors</topic><topic>pulsewidth modulation (PWM)</topic><topic>ripple-based control</topic><topic>Switches</topic><topic>switching converter</topic><topic>V^{2} control</topic><topic>V^{2}C control</topic><topic>Voltage control</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zhou, Guohua</creatorcontrib><creatorcontrib>Xu, Jianping</creatorcontrib><creatorcontrib>Wang, Jinping</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005–Present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><jtitle>IEEE transactions on industrial electronics (1982)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Zhou, Guohua</au><au>Xu, Jianping</au><au>Wang, Jinping</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Constant-Frequency Peak-Ripple-Based Control of Buck Converter in CCM: Review, Unification, and Duality</atitle><jtitle>IEEE transactions on industrial electronics (1982)</jtitle><stitle>TIE</stitle><date>2014-03-01</date><risdate>2014</risdate><volume>61</volume><issue>3</issue><spage>1280</spage><epage>1291</epage><pages>1280-1291</pages><issn>0278-0046</issn><eissn>1557-9948</eissn><coden>ITIED6</coden><abstract>The operation principles of peak current control, V 2 control, and enhanced- V 2 control of buck converter in continuous conduction mode are reviewed and compared. By the use of weight factors of inductor current and output voltage, they are unified as constant-frequency peak-ripple-based (CF-PR) analog control. It is revealed that conventional peak current control and V 2 control are two boundaries of the unified CF-PR control. The duality items between CF-PR control and constant-frequency valley-ripple-based (CF-VR) control are proposed. As the duality of CF-PR analog control, CF-VR analog control is investigated. Unified CF-PR and CF-VR digital control laws with different modulations and their stabilities are investigated in terms of the duality. Experimental results verify the theory analysis.</abstract><pub>IEEE</pub><doi>10.1109/TIE.2013.2257143</doi><tpages>12</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 0278-0046 |
ispartof | IEEE transactions on industrial electronics (1982), 2014-03, Vol.61 (3), p.1280-1291 |
issn | 0278-0046 1557-9948 |
language | eng |
recordid | cdi_crossref_primary_10_1109_TIE_2013_2257143 |
source | IEEE Electronic Library (IEL) |
subjects | Buck converters Current control Current-mode control Digital control enhanced- V^{2} control Inductors pulsewidth modulation (PWM) ripple-based control Switches switching converter V^{2} control V^{2}C control Voltage control |
title | Constant-Frequency Peak-Ripple-Based Control of Buck Converter in CCM: Review, Unification, and Duality |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T08%3A50%3A11IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Constant-Frequency%20Peak-Ripple-Based%20Control%20of%20Buck%20Converter%20in%20CCM:%20Review,%20Unification,%20and%20Duality&rft.jtitle=IEEE%20transactions%20on%20industrial%20electronics%20(1982)&rft.au=Zhou,%20Guohua&rft.date=2014-03-01&rft.volume=61&rft.issue=3&rft.spage=1280&rft.epage=1291&rft.pages=1280-1291&rft.issn=0278-0046&rft.eissn=1557-9948&rft.coden=ITIED6&rft_id=info:doi/10.1109/TIE.2013.2257143&rft_dat=%3Ccrossref_RIE%3E10_1109_TIE_2013_2257143%3C/crossref_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6494638&rfr_iscdi=true |