Dynamic Control of the Brushless Doubly Fed Induction Generator Under Unbalanced Operation
The brushless doubly fed induction generator (DFIG) (BDFIG) shows commercial promise for wind power generation because of its lower maintenance needs compared to the widely used DFIG. From power grid codes, installed wind turbines are sometimes required to be capable of operating under unbalanced gr...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on industrial electronics (1982) 2013-06, Vol.60 (6), p.2465-2476 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 2476 |
---|---|
container_issue | 6 |
container_start_page | 2465 |
container_title | IEEE transactions on industrial electronics (1982) |
container_volume | 60 |
creator | Shiyi Shao Teng Long Abdi, E. McMahon, R. A. |
description | The brushless doubly fed induction generator (DFIG) (BDFIG) shows commercial promise for wind power generation because of its lower maintenance needs compared to the widely used DFIG. From power grid codes, installed wind turbines are sometimes required to be capable of operating under unbalanced grid conditions. This paper presents a novel controller for BDFIG-based wind generators operated with asymmetrical voltage supplies. Two synchronous reference frames, the positive and the negative, are introduced for applying a vector control scheme to separately control two sequences arising from the unbalanced voltage. Different control strategies are discussed for reducing the consequent oscillations. It is demonstrated that the proposed controller shows a significant performance improvement over the conventional controller and is effective to cope with potentially unbalanced conditions. |
doi_str_mv | 10.1109/TIE.2012.2211313 |
format | Article |
fullrecord | <record><control><sourceid>crossref_RIE</sourceid><recordid>TN_cdi_crossref_primary_10_1109_TIE_2012_2211313</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6264095</ieee_id><sourcerecordid>10_1109_TIE_2012_2211313</sourcerecordid><originalsourceid>FETCH-LOGICAL-c263t-32e153bafc833724c2494e2563b116fb350357693d0ed8b2d9bbe160108f513f3</originalsourceid><addsrcrecordid>eNo9kLtuwkAQRVdRIoWQ9JHS7A-YzOzL3jKBQJCQaKBJY3ntsXBkvGjXFPx9bIHSzC3m3Fscxl4RZohg33frr5kAFDMhECXKOzZBrdPEWpXdswmINEsAlHlkTzH-AqDSqCfsZ3HpimNT8rnv-uBb7mveH4h_hnM8tBQjX_izay98SRVfd9W57Bvf8RV1FIreB77vKhqvK9qiKwdoexo_A_TMHuqijfRyyynbL7928-9ks12t5x-bpBRG9okUhFq6oi4zKVOhSqGsIqGNdIimdlKD1KmxsgKqMicq6xyhAYSs1ihrOWVw3S2DjzFQnZ9CcyzCJUfIRzf54CYf3eQ3N0Pl7VppiOgfN8IosFr-AQPWX5s</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Dynamic Control of the Brushless Doubly Fed Induction Generator Under Unbalanced Operation</title><source>IEEE Electronic Library (IEL)</source><creator>Shiyi Shao ; Teng Long ; Abdi, E. ; McMahon, R. A.</creator><creatorcontrib>Shiyi Shao ; Teng Long ; Abdi, E. ; McMahon, R. A.</creatorcontrib><description>The brushless doubly fed induction generator (DFIG) (BDFIG) shows commercial promise for wind power generation because of its lower maintenance needs compared to the widely used DFIG. From power grid codes, installed wind turbines are sometimes required to be capable of operating under unbalanced grid conditions. This paper presents a novel controller for BDFIG-based wind generators operated with asymmetrical voltage supplies. Two synchronous reference frames, the positive and the negative, are introduced for applying a vector control scheme to separately control two sequences arising from the unbalanced voltage. Different control strategies are discussed for reducing the consequent oscillations. It is demonstrated that the proposed controller shows a significant performance improvement over the conventional controller and is effective to cope with potentially unbalanced conditions.</description><identifier>ISSN: 0278-0046</identifier><identifier>EISSN: 1557-9948</identifier><identifier>DOI: 10.1109/TIE.2012.2211313</identifier><identifier>CODEN: ITIED6</identifier><language>eng</language><publisher>IEEE</publisher><subject>AC generators ; doubly-fed induction generators ; grid connection ; Oscillators ; Reactive power ; Rotors ; Vectors ; Voltage control ; wind energy ; Wind turbines ; Windings</subject><ispartof>IEEE transactions on industrial electronics (1982), 2013-06, Vol.60 (6), p.2465-2476</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c263t-32e153bafc833724c2494e2563b116fb350357693d0ed8b2d9bbe160108f513f3</citedby><cites>FETCH-LOGICAL-c263t-32e153bafc833724c2494e2563b116fb350357693d0ed8b2d9bbe160108f513f3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6264095$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,780,784,796,27924,27925,54758</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6264095$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Shiyi Shao</creatorcontrib><creatorcontrib>Teng Long</creatorcontrib><creatorcontrib>Abdi, E.</creatorcontrib><creatorcontrib>McMahon, R. A.</creatorcontrib><title>Dynamic Control of the Brushless Doubly Fed Induction Generator Under Unbalanced Operation</title><title>IEEE transactions on industrial electronics (1982)</title><addtitle>TIE</addtitle><description>The brushless doubly fed induction generator (DFIG) (BDFIG) shows commercial promise for wind power generation because of its lower maintenance needs compared to the widely used DFIG. From power grid codes, installed wind turbines are sometimes required to be capable of operating under unbalanced grid conditions. This paper presents a novel controller for BDFIG-based wind generators operated with asymmetrical voltage supplies. Two synchronous reference frames, the positive and the negative, are introduced for applying a vector control scheme to separately control two sequences arising from the unbalanced voltage. Different control strategies are discussed for reducing the consequent oscillations. It is demonstrated that the proposed controller shows a significant performance improvement over the conventional controller and is effective to cope with potentially unbalanced conditions.</description><subject>AC generators</subject><subject>doubly-fed induction generators</subject><subject>grid connection</subject><subject>Oscillators</subject><subject>Reactive power</subject><subject>Rotors</subject><subject>Vectors</subject><subject>Voltage control</subject><subject>wind energy</subject><subject>Wind turbines</subject><subject>Windings</subject><issn>0278-0046</issn><issn>1557-9948</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNo9kLtuwkAQRVdRIoWQ9JHS7A-YzOzL3jKBQJCQaKBJY3ntsXBkvGjXFPx9bIHSzC3m3Fscxl4RZohg33frr5kAFDMhECXKOzZBrdPEWpXdswmINEsAlHlkTzH-AqDSqCfsZ3HpimNT8rnv-uBb7mveH4h_hnM8tBQjX_izay98SRVfd9W57Bvf8RV1FIreB77vKhqvK9qiKwdoexo_A_TMHuqijfRyyynbL7928-9ks12t5x-bpBRG9okUhFq6oi4zKVOhSqGsIqGNdIimdlKD1KmxsgKqMicq6xyhAYSs1ihrOWVw3S2DjzFQnZ9CcyzCJUfIRzf54CYf3eQ3N0Pl7VppiOgfN8IosFr-AQPWX5s</recordid><startdate>20130601</startdate><enddate>20130601</enddate><creator>Shiyi Shao</creator><creator>Teng Long</creator><creator>Abdi, E.</creator><creator>McMahon, R. A.</creator><general>IEEE</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20130601</creationdate><title>Dynamic Control of the Brushless Doubly Fed Induction Generator Under Unbalanced Operation</title><author>Shiyi Shao ; Teng Long ; Abdi, E. ; McMahon, R. A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c263t-32e153bafc833724c2494e2563b116fb350357693d0ed8b2d9bbe160108f513f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>AC generators</topic><topic>doubly-fed induction generators</topic><topic>grid connection</topic><topic>Oscillators</topic><topic>Reactive power</topic><topic>Rotors</topic><topic>Vectors</topic><topic>Voltage control</topic><topic>wind energy</topic><topic>Wind turbines</topic><topic>Windings</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Shiyi Shao</creatorcontrib><creatorcontrib>Teng Long</creatorcontrib><creatorcontrib>Abdi, E.</creatorcontrib><creatorcontrib>McMahon, R. A.</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><jtitle>IEEE transactions on industrial electronics (1982)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Shiyi Shao</au><au>Teng Long</au><au>Abdi, E.</au><au>McMahon, R. A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Dynamic Control of the Brushless Doubly Fed Induction Generator Under Unbalanced Operation</atitle><jtitle>IEEE transactions on industrial electronics (1982)</jtitle><stitle>TIE</stitle><date>2013-06-01</date><risdate>2013</risdate><volume>60</volume><issue>6</issue><spage>2465</spage><epage>2476</epage><pages>2465-2476</pages><issn>0278-0046</issn><eissn>1557-9948</eissn><coden>ITIED6</coden><abstract>The brushless doubly fed induction generator (DFIG) (BDFIG) shows commercial promise for wind power generation because of its lower maintenance needs compared to the widely used DFIG. From power grid codes, installed wind turbines are sometimes required to be capable of operating under unbalanced grid conditions. This paper presents a novel controller for BDFIG-based wind generators operated with asymmetrical voltage supplies. Two synchronous reference frames, the positive and the negative, are introduced for applying a vector control scheme to separately control two sequences arising from the unbalanced voltage. Different control strategies are discussed for reducing the consequent oscillations. It is demonstrated that the proposed controller shows a significant performance improvement over the conventional controller and is effective to cope with potentially unbalanced conditions.</abstract><pub>IEEE</pub><doi>10.1109/TIE.2012.2211313</doi><tpages>12</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 0278-0046 |
ispartof | IEEE transactions on industrial electronics (1982), 2013-06, Vol.60 (6), p.2465-2476 |
issn | 0278-0046 1557-9948 |
language | eng |
recordid | cdi_crossref_primary_10_1109_TIE_2012_2211313 |
source | IEEE Electronic Library (IEL) |
subjects | AC generators doubly-fed induction generators grid connection Oscillators Reactive power Rotors Vectors Voltage control wind energy Wind turbines Windings |
title | Dynamic Control of the Brushless Doubly Fed Induction Generator Under Unbalanced Operation |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T05%3A17%3A17IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Dynamic%20Control%20of%20the%20Brushless%20Doubly%20Fed%20Induction%20Generator%20Under%20Unbalanced%20Operation&rft.jtitle=IEEE%20transactions%20on%20industrial%20electronics%20(1982)&rft.au=Shiyi%20Shao&rft.date=2013-06-01&rft.volume=60&rft.issue=6&rft.spage=2465&rft.epage=2476&rft.pages=2465-2476&rft.issn=0278-0046&rft.eissn=1557-9948&rft.coden=ITIED6&rft_id=info:doi/10.1109/TIE.2012.2211313&rft_dat=%3Ccrossref_RIE%3E10_1109_TIE_2012_2211313%3C/crossref_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6264095&rfr_iscdi=true |