Safety and Environmental Evaluation of Insulating Media in Medium-Voltage Distribution Equipment

The hazards associated with performing maintenance on energized electrical equipment have been the subject of massive amounts of literature as well as the driver for numerous product innovations aimed at mitigating the effects of this hazard. The intent of this paper is to highlight potential person...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on industry applications 2009-05, Vol.45 (3), p.1155-1158
Hauptverfasser: Yanniello, R., Paoletti, G.J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1158
container_issue 3
container_start_page 1155
container_title IEEE transactions on industry applications
container_volume 45
creator Yanniello, R.
Paoletti, G.J.
description The hazards associated with performing maintenance on energized electrical equipment have been the subject of massive amounts of literature as well as the driver for numerous product innovations aimed at mitigating the effects of this hazard. The intent of this paper is to highlight potential personal and environmental dangers associated with this same equipment when it is deenergized. This paper is specifically targeted at switchgear and circuit breakers rated above 1000 V and is more specifically targeted at personnel who perform maintenance, decommissioning, retrofitting, or clean up after catastrophic failures of this class of equipment.
doi_str_mv 10.1109/TIA.2009.2018957
format Article
fullrecord <record><control><sourceid>proquest_RIE</sourceid><recordid>TN_cdi_crossref_primary_10_1109_TIA_2009_2018957</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4957528</ieee_id><sourcerecordid>2291801591</sourcerecordid><originalsourceid>FETCH-LOGICAL-c386t-e97126f360ebb1b9b1e096d8e0093e586a4b818db8769b0bd9375552052904693</originalsourceid><addsrcrecordid>eNqNkT1P3EAQhlcokbgQ-kg0Fk0qw-ynd0oEl-QkohQhtJvd8xgt8q0Pr43Ev2ePQyloSDMfmucdzehl7AuHM84Bz29WF2cCAEvgFnVzwBYcJdYoTfOBLcpE1oioDtmnnO8BuNJcLdjf376j6anyqa2W6TGOQ9pQmnxfLR99P_spDqkaumqV8tyXLt1VP6mNvorppZg39e3QT_6OqquYpzGG-UWyfJjjdrfpM_vY-T7T8Ws-Yn--LW8uf9TXv76vLi-u67W0ZqoJGy5MJw1QCDxg4ARoWku7w0lb41Ww3LbBNgYDhBZlo7UWoAWCMiiP2Nf93u04PMyUJ7eJeU197xMNc3bWoNVKgXqXbJQ2oIGb_yClEUJYUcjTN-T9MI-pPOysNgi8aWyBYA-txyHnkTq3HePGj0-Og9uZ6IqJbmeiezWxSE72kkhE_3BVRlpY-Qx0RZak</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>856901778</pqid></control><display><type>article</type><title>Safety and Environmental Evaluation of Insulating Media in Medium-Voltage Distribution Equipment</title><source>IEEE Electronic Library (IEL)</source><creator>Yanniello, R. ; Paoletti, G.J.</creator><creatorcontrib>Yanniello, R. ; Paoletti, G.J.</creatorcontrib><description>The hazards associated with performing maintenance on energized electrical equipment have been the subject of massive amounts of literature as well as the driver for numerous product innovations aimed at mitigating the effects of this hazard. The intent of this paper is to highlight potential personal and environmental dangers associated with this same equipment when it is deenergized. This paper is specifically targeted at switchgear and circuit breakers rated above 1000 V and is more specifically targeted at personnel who perform maintenance, decommissioning, retrofitting, or clean up after catastrophic failures of this class of equipment.</description><identifier>ISSN: 0093-9994</identifier><identifier>EISSN: 1939-9367</identifier><identifier>DOI: 10.1109/TIA.2009.2018957</identifier><identifier>CODEN: ITIACR</identifier><language>eng</language><publisher>New York: IEEE</publisher><subject>Asbestos ; Circuit breakers ; Electrical safety ; gas-insulated switchgear (GIS) ; greenhouse gas (GHG) ; Hazardous materials ; Hazards ; Insulation ; maintenance ; Manufacturing ; Medium voltage ; oil ; Personnel ; polychlorinated biphenyls (PCBs) ; Safety devices ; sulfur hexafluoride ( hbox{SF}_{6} ) ; Switchgear</subject><ispartof>IEEE transactions on industry applications, 2009-05, Vol.45 (3), p.1155-1158</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2009</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c386t-e97126f360ebb1b9b1e096d8e0093e586a4b818db8769b0bd9375552052904693</citedby><cites>FETCH-LOGICAL-c386t-e97126f360ebb1b9b1e096d8e0093e586a4b818db8769b0bd9375552052904693</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4957528$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,780,784,796,27924,27925,54758</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4957528$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Yanniello, R.</creatorcontrib><creatorcontrib>Paoletti, G.J.</creatorcontrib><title>Safety and Environmental Evaluation of Insulating Media in Medium-Voltage Distribution Equipment</title><title>IEEE transactions on industry applications</title><addtitle>TIA</addtitle><description>The hazards associated with performing maintenance on energized electrical equipment have been the subject of massive amounts of literature as well as the driver for numerous product innovations aimed at mitigating the effects of this hazard. The intent of this paper is to highlight potential personal and environmental dangers associated with this same equipment when it is deenergized. This paper is specifically targeted at switchgear and circuit breakers rated above 1000 V and is more specifically targeted at personnel who perform maintenance, decommissioning, retrofitting, or clean up after catastrophic failures of this class of equipment.</description><subject>Asbestos</subject><subject>Circuit breakers</subject><subject>Electrical safety</subject><subject>gas-insulated switchgear (GIS)</subject><subject>greenhouse gas (GHG)</subject><subject>Hazardous materials</subject><subject>Hazards</subject><subject>Insulation</subject><subject>maintenance</subject><subject>Manufacturing</subject><subject>Medium voltage</subject><subject>oil</subject><subject>Personnel</subject><subject>polychlorinated biphenyls (PCBs)</subject><subject>Safety devices</subject><subject>sulfur hexafluoride ( hbox{SF}_{6} )</subject><subject>Switchgear</subject><issn>0093-9994</issn><issn>1939-9367</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNqNkT1P3EAQhlcokbgQ-kg0Fk0qw-ynd0oEl-QkohQhtJvd8xgt8q0Pr43Ev2ePQyloSDMfmucdzehl7AuHM84Bz29WF2cCAEvgFnVzwBYcJdYoTfOBLcpE1oioDtmnnO8BuNJcLdjf376j6anyqa2W6TGOQ9pQmnxfLR99P_spDqkaumqV8tyXLt1VP6mNvorppZg39e3QT_6OqquYpzGG-UWyfJjjdrfpM_vY-T7T8Ws-Yn--LW8uf9TXv76vLi-u67W0ZqoJGy5MJw1QCDxg4ARoWku7w0lb41Ww3LbBNgYDhBZlo7UWoAWCMiiP2Nf93u04PMyUJ7eJeU197xMNc3bWoNVKgXqXbJQ2oIGb_yClEUJYUcjTN-T9MI-pPOysNgi8aWyBYA-txyHnkTq3HePGj0-Og9uZ6IqJbmeiezWxSE72kkhE_3BVRlpY-Qx0RZak</recordid><startdate>20090501</startdate><enddate>20090501</enddate><creator>Yanniello, R.</creator><creator>Paoletti, G.J.</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SC</scope><scope>7SP</scope><scope>8FD</scope><scope>JQ2</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>F28</scope><scope>FR3</scope><scope>7T2</scope><scope>7U2</scope><scope>C1K</scope></search><sort><creationdate>20090501</creationdate><title>Safety and Environmental Evaluation of Insulating Media in Medium-Voltage Distribution Equipment</title><author>Yanniello, R. ; Paoletti, G.J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c386t-e97126f360ebb1b9b1e096d8e0093e586a4b818db8769b0bd9375552052904693</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Asbestos</topic><topic>Circuit breakers</topic><topic>Electrical safety</topic><topic>gas-insulated switchgear (GIS)</topic><topic>greenhouse gas (GHG)</topic><topic>Hazardous materials</topic><topic>Hazards</topic><topic>Insulation</topic><topic>maintenance</topic><topic>Manufacturing</topic><topic>Medium voltage</topic><topic>oil</topic><topic>Personnel</topic><topic>polychlorinated biphenyls (PCBs)</topic><topic>Safety devices</topic><topic>sulfur hexafluoride ( hbox{SF}_{6} )</topic><topic>Switchgear</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yanniello, R.</creatorcontrib><creatorcontrib>Paoletti, G.J.</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><collection>Computer and Information Systems Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Technology Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Health and Safety Science Abstracts (Full archive)</collection><collection>Safety Science and Risk</collection><collection>Environmental Sciences and Pollution Management</collection><jtitle>IEEE transactions on industry applications</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Yanniello, R.</au><au>Paoletti, G.J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Safety and Environmental Evaluation of Insulating Media in Medium-Voltage Distribution Equipment</atitle><jtitle>IEEE transactions on industry applications</jtitle><stitle>TIA</stitle><date>2009-05-01</date><risdate>2009</risdate><volume>45</volume><issue>3</issue><spage>1155</spage><epage>1158</epage><pages>1155-1158</pages><issn>0093-9994</issn><eissn>1939-9367</eissn><coden>ITIACR</coden><abstract>The hazards associated with performing maintenance on energized electrical equipment have been the subject of massive amounts of literature as well as the driver for numerous product innovations aimed at mitigating the effects of this hazard. The intent of this paper is to highlight potential personal and environmental dangers associated with this same equipment when it is deenergized. This paper is specifically targeted at switchgear and circuit breakers rated above 1000 V and is more specifically targeted at personnel who perform maintenance, decommissioning, retrofitting, or clean up after catastrophic failures of this class of equipment.</abstract><cop>New York</cop><pub>IEEE</pub><doi>10.1109/TIA.2009.2018957</doi><tpages>4</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 0093-9994
ispartof IEEE transactions on industry applications, 2009-05, Vol.45 (3), p.1155-1158
issn 0093-9994
1939-9367
language eng
recordid cdi_crossref_primary_10_1109_TIA_2009_2018957
source IEEE Electronic Library (IEL)
subjects Asbestos
Circuit breakers
Electrical safety
gas-insulated switchgear (GIS)
greenhouse gas (GHG)
Hazardous materials
Hazards
Insulation
maintenance
Manufacturing
Medium voltage
oil
Personnel
polychlorinated biphenyls (PCBs)
Safety devices
sulfur hexafluoride ( hbox{SF}_{6} )
Switchgear
title Safety and Environmental Evaluation of Insulating Media in Medium-Voltage Distribution Equipment
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-24T12%3A06%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Safety%20and%20Environmental%20Evaluation%20of%20Insulating%20Media%20in%20Medium-Voltage%20Distribution%20Equipment&rft.jtitle=IEEE%20transactions%20on%20industry%20applications&rft.au=Yanniello,%20R.&rft.date=2009-05-01&rft.volume=45&rft.issue=3&rft.spage=1155&rft.epage=1158&rft.pages=1155-1158&rft.issn=0093-9994&rft.eissn=1939-9367&rft.coden=ITIACR&rft_id=info:doi/10.1109/TIA.2009.2018957&rft_dat=%3Cproquest_RIE%3E2291801591%3C/proquest_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=856901778&rft_id=info:pmid/&rft_ieee_id=4957528&rfr_iscdi=true