RF-Care: RFID-Based Human Pose Estimation for Nursing-Care Applications Under Visual Occlusion

Occlusion and environmental light changes often exist in intelligent care scenarios. Human posture sensing through vision alone is prone to misjudgment, so human posture sensing methods other than vision are needed. This article proposes RF-Care, an RFID-based human pose estimation system that avoid...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE sensors journal 2024-11, Vol.24 (21), p.35359-35366
Hauptverfasser: Liu, Jixiao, Xia, Zihou, Liu, Junyi, Guo, Shijie
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 35366
container_issue 21
container_start_page 35359
container_title IEEE sensors journal
container_volume 24
creator Liu, Jixiao
Xia, Zihou
Liu, Junyi
Guo, Shijie
description Occlusion and environmental light changes often exist in intelligent care scenarios. Human posture sensing through vision alone is prone to misjudgment, so human posture sensing methods other than vision are needed. This article proposes RF-Care, an RFID-based human pose estimation system that avoids these problems. RF-Care uses the phase difference between RFID tags on the limbs and antennas to determine body joint positions and motion. It requires only a wearable RFID tag array and a simple RF antenna setup. We introduce a fine-grained limb tracking algorithm and dual-antenna 3-D pose estimation method to achieve accurate results despite occlusions. Experiments validate RF-Care's performance for subjects standing or lying in bed under blankets/quilts. Compared to Kinect 2.0, the mean position error is about 4 cm without occlusion. The standard deviation (STD) is about 3.4 cm when visually occluded. RF-Care efficiently monitors full-body posture regardless of impediments, benefiting intelligent nursing care and other applications requiring accurate real-time pose measurement.
doi_str_mv 10.1109/JSEN.2024.3407962
format Article
fullrecord <record><control><sourceid>crossref_RIE</sourceid><recordid>TN_cdi_crossref_primary_10_1109_JSEN_2024_3407962</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>10559947</ieee_id><sourcerecordid>10_1109_JSEN_2024_3407962</sourcerecordid><originalsourceid>FETCH-LOGICAL-c637-b95831b9a4a48b5023798238a3ec8bd0f31f4517f2d6e2bb5a29c49aabb950a23</originalsourceid><addsrcrecordid>eNpNkE1OwzAQRi0EEqVwACQWvoCLf2ObXSktLapaVApiRWQ7DgpKk8huFtyepO2C1YzmmzcaPQBuCR4RgvX9y9t0NaKY8hHjWOqEnoEBEUIhIrk673uGEWfy8xJcxfiDMdFSyAH42szQxAT_ADezxRN6NNFncN7uTAVf6-jhNO6LndkXdQXzOsBVG2JRfR8QOG6asnCHMML3KvMBfhSxNSVcO1e2sZtfg4vclNHfnOoQbGfT7WSOluvnxWS8RC5hElktFCNWG264sgJTJrWiTBnmnbIZzhnJuSAyp1niqbXCUO24NsZ2JDaUDQE5nnWhjjH4PG1C93b4TQlOez9p7yft_aQnPx1zd2QK7_2_fSG05pL9AbyTYU4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>RF-Care: RFID-Based Human Pose Estimation for Nursing-Care Applications Under Visual Occlusion</title><source>IEEE Electronic Library (IEL)</source><creator>Liu, Jixiao ; Xia, Zihou ; Liu, Junyi ; Guo, Shijie</creator><creatorcontrib>Liu, Jixiao ; Xia, Zihou ; Liu, Junyi ; Guo, Shijie</creatorcontrib><description>Occlusion and environmental light changes often exist in intelligent care scenarios. Human posture sensing through vision alone is prone to misjudgment, so human posture sensing methods other than vision are needed. This article proposes RF-Care, an RFID-based human pose estimation system that avoids these problems. RF-Care uses the phase difference between RFID tags on the limbs and antennas to determine body joint positions and motion. It requires only a wearable RFID tag array and a simple RF antenna setup. We introduce a fine-grained limb tracking algorithm and dual-antenna 3-D pose estimation method to achieve accurate results despite occlusions. Experiments validate RF-Care's performance for subjects standing or lying in bed under blankets/quilts. Compared to Kinect 2.0, the mean position error is about 4 cm without occlusion. The standard deviation (STD) is about 3.4 cm when visually occluded. RF-Care efficiently monitors full-body posture regardless of impediments, benefiting intelligent nursing care and other applications requiring accurate real-time pose measurement.</description><identifier>ISSN: 1530-437X</identifier><identifier>EISSN: 1558-1748</identifier><identifier>DOI: 10.1109/JSEN.2024.3407962</identifier><identifier>CODEN: ISJEAZ</identifier><language>eng</language><publisher>IEEE</publisher><subject>Accuracy ; Human body posture ; Legged locomotion ; phase difference ; Pose estimation ; radio frequency identification (RFID) ; RFID tags ; Sensors ; Tracking ; Visualization ; wearable devices</subject><ispartof>IEEE sensors journal, 2024-11, Vol.24 (21), p.35359-35366</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c637-b95831b9a4a48b5023798238a3ec8bd0f31f4517f2d6e2bb5a29c49aabb950a23</cites><orcidid>0000-0002-0355-9980 ; 0000-0002-1335-2852 ; 0009-0001-4262-6031</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/10559947$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,776,780,792,27901,27902,54733</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/10559947$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Liu, Jixiao</creatorcontrib><creatorcontrib>Xia, Zihou</creatorcontrib><creatorcontrib>Liu, Junyi</creatorcontrib><creatorcontrib>Guo, Shijie</creatorcontrib><title>RF-Care: RFID-Based Human Pose Estimation for Nursing-Care Applications Under Visual Occlusion</title><title>IEEE sensors journal</title><addtitle>JSEN</addtitle><description>Occlusion and environmental light changes often exist in intelligent care scenarios. Human posture sensing through vision alone is prone to misjudgment, so human posture sensing methods other than vision are needed. This article proposes RF-Care, an RFID-based human pose estimation system that avoids these problems. RF-Care uses the phase difference between RFID tags on the limbs and antennas to determine body joint positions and motion. It requires only a wearable RFID tag array and a simple RF antenna setup. We introduce a fine-grained limb tracking algorithm and dual-antenna 3-D pose estimation method to achieve accurate results despite occlusions. Experiments validate RF-Care's performance for subjects standing or lying in bed under blankets/quilts. Compared to Kinect 2.0, the mean position error is about 4 cm without occlusion. The standard deviation (STD) is about 3.4 cm when visually occluded. RF-Care efficiently monitors full-body posture regardless of impediments, benefiting intelligent nursing care and other applications requiring accurate real-time pose measurement.</description><subject>Accuracy</subject><subject>Human body posture</subject><subject>Legged locomotion</subject><subject>phase difference</subject><subject>Pose estimation</subject><subject>radio frequency identification (RFID)</subject><subject>RFID tags</subject><subject>Sensors</subject><subject>Tracking</subject><subject>Visualization</subject><subject>wearable devices</subject><issn>1530-437X</issn><issn>1558-1748</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNpNkE1OwzAQRi0EEqVwACQWvoCLf2ObXSktLapaVApiRWQ7DgpKk8huFtyepO2C1YzmmzcaPQBuCR4RgvX9y9t0NaKY8hHjWOqEnoEBEUIhIrk673uGEWfy8xJcxfiDMdFSyAH42szQxAT_ADezxRN6NNFncN7uTAVf6-jhNO6LndkXdQXzOsBVG2JRfR8QOG6asnCHMML3KvMBfhSxNSVcO1e2sZtfg4vclNHfnOoQbGfT7WSOluvnxWS8RC5hElktFCNWG264sgJTJrWiTBnmnbIZzhnJuSAyp1niqbXCUO24NsZ2JDaUDQE5nnWhjjH4PG1C93b4TQlOez9p7yft_aQnPx1zd2QK7_2_fSG05pL9AbyTYU4</recordid><startdate>20241101</startdate><enddate>20241101</enddate><creator>Liu, Jixiao</creator><creator>Xia, Zihou</creator><creator>Liu, Junyi</creator><creator>Guo, Shijie</creator><general>IEEE</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0002-0355-9980</orcidid><orcidid>https://orcid.org/0000-0002-1335-2852</orcidid><orcidid>https://orcid.org/0009-0001-4262-6031</orcidid></search><sort><creationdate>20241101</creationdate><title>RF-Care: RFID-Based Human Pose Estimation for Nursing-Care Applications Under Visual Occlusion</title><author>Liu, Jixiao ; Xia, Zihou ; Liu, Junyi ; Guo, Shijie</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c637-b95831b9a4a48b5023798238a3ec8bd0f31f4517f2d6e2bb5a29c49aabb950a23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Accuracy</topic><topic>Human body posture</topic><topic>Legged locomotion</topic><topic>phase difference</topic><topic>Pose estimation</topic><topic>radio frequency identification (RFID)</topic><topic>RFID tags</topic><topic>Sensors</topic><topic>Tracking</topic><topic>Visualization</topic><topic>wearable devices</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Liu, Jixiao</creatorcontrib><creatorcontrib>Xia, Zihou</creatorcontrib><creatorcontrib>Liu, Junyi</creatorcontrib><creatorcontrib>Guo, Shijie</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><jtitle>IEEE sensors journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Liu, Jixiao</au><au>Xia, Zihou</au><au>Liu, Junyi</au><au>Guo, Shijie</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>RF-Care: RFID-Based Human Pose Estimation for Nursing-Care Applications Under Visual Occlusion</atitle><jtitle>IEEE sensors journal</jtitle><stitle>JSEN</stitle><date>2024-11-01</date><risdate>2024</risdate><volume>24</volume><issue>21</issue><spage>35359</spage><epage>35366</epage><pages>35359-35366</pages><issn>1530-437X</issn><eissn>1558-1748</eissn><coden>ISJEAZ</coden><abstract>Occlusion and environmental light changes often exist in intelligent care scenarios. Human posture sensing through vision alone is prone to misjudgment, so human posture sensing methods other than vision are needed. This article proposes RF-Care, an RFID-based human pose estimation system that avoids these problems. RF-Care uses the phase difference between RFID tags on the limbs and antennas to determine body joint positions and motion. It requires only a wearable RFID tag array and a simple RF antenna setup. We introduce a fine-grained limb tracking algorithm and dual-antenna 3-D pose estimation method to achieve accurate results despite occlusions. Experiments validate RF-Care's performance for subjects standing or lying in bed under blankets/quilts. Compared to Kinect 2.0, the mean position error is about 4 cm without occlusion. The standard deviation (STD) is about 3.4 cm when visually occluded. RF-Care efficiently monitors full-body posture regardless of impediments, benefiting intelligent nursing care and other applications requiring accurate real-time pose measurement.</abstract><pub>IEEE</pub><doi>10.1109/JSEN.2024.3407962</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0002-0355-9980</orcidid><orcidid>https://orcid.org/0000-0002-1335-2852</orcidid><orcidid>https://orcid.org/0009-0001-4262-6031</orcidid></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1530-437X
ispartof IEEE sensors journal, 2024-11, Vol.24 (21), p.35359-35366
issn 1530-437X
1558-1748
language eng
recordid cdi_crossref_primary_10_1109_JSEN_2024_3407962
source IEEE Electronic Library (IEL)
subjects Accuracy
Human body posture
Legged locomotion
phase difference
Pose estimation
radio frequency identification (RFID)
RFID tags
Sensors
Tracking
Visualization
wearable devices
title RF-Care: RFID-Based Human Pose Estimation for Nursing-Care Applications Under Visual Occlusion
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T22%3A32%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=RF-Care:%20RFID-Based%20Human%20Pose%20Estimation%20for%20Nursing-Care%20Applications%20Under%20Visual%20Occlusion&rft.jtitle=IEEE%20sensors%20journal&rft.au=Liu,%20Jixiao&rft.date=2024-11-01&rft.volume=24&rft.issue=21&rft.spage=35359&rft.epage=35366&rft.pages=35359-35366&rft.issn=1530-437X&rft.eissn=1558-1748&rft.coden=ISJEAZ&rft_id=info:doi/10.1109/JSEN.2024.3407962&rft_dat=%3Ccrossref_RIE%3E10_1109_JSEN_2024_3407962%3C/crossref_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=10559947&rfr_iscdi=true