RF-Care: RFID-Based Human Pose Estimation for Nursing-Care Applications Under Visual Occlusion
Occlusion and environmental light changes often exist in intelligent care scenarios. Human posture sensing through vision alone is prone to misjudgment, so human posture sensing methods other than vision are needed. This article proposes RF-Care, an RFID-based human pose estimation system that avoid...
Gespeichert in:
Veröffentlicht in: | IEEE sensors journal 2024-11, Vol.24 (21), p.35359-35366 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 35366 |
---|---|
container_issue | 21 |
container_start_page | 35359 |
container_title | IEEE sensors journal |
container_volume | 24 |
creator | Liu, Jixiao Xia, Zihou Liu, Junyi Guo, Shijie |
description | Occlusion and environmental light changes often exist in intelligent care scenarios. Human posture sensing through vision alone is prone to misjudgment, so human posture sensing methods other than vision are needed. This article proposes RF-Care, an RFID-based human pose estimation system that avoids these problems. RF-Care uses the phase difference between RFID tags on the limbs and antennas to determine body joint positions and motion. It requires only a wearable RFID tag array and a simple RF antenna setup. We introduce a fine-grained limb tracking algorithm and dual-antenna 3-D pose estimation method to achieve accurate results despite occlusions. Experiments validate RF-Care's performance for subjects standing or lying in bed under blankets/quilts. Compared to Kinect 2.0, the mean position error is about 4 cm without occlusion. The standard deviation (STD) is about 3.4 cm when visually occluded. RF-Care efficiently monitors full-body posture regardless of impediments, benefiting intelligent nursing care and other applications requiring accurate real-time pose measurement. |
doi_str_mv | 10.1109/JSEN.2024.3407962 |
format | Article |
fullrecord | <record><control><sourceid>crossref_RIE</sourceid><recordid>TN_cdi_crossref_primary_10_1109_JSEN_2024_3407962</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>10559947</ieee_id><sourcerecordid>10_1109_JSEN_2024_3407962</sourcerecordid><originalsourceid>FETCH-LOGICAL-c637-b95831b9a4a48b5023798238a3ec8bd0f31f4517f2d6e2bb5a29c49aabb950a23</originalsourceid><addsrcrecordid>eNpNkE1OwzAQRi0EEqVwACQWvoCLf2ObXSktLapaVApiRWQ7DgpKk8huFtyepO2C1YzmmzcaPQBuCR4RgvX9y9t0NaKY8hHjWOqEnoEBEUIhIrk673uGEWfy8xJcxfiDMdFSyAH42szQxAT_ADezxRN6NNFncN7uTAVf6-jhNO6LndkXdQXzOsBVG2JRfR8QOG6asnCHMML3KvMBfhSxNSVcO1e2sZtfg4vclNHfnOoQbGfT7WSOluvnxWS8RC5hElktFCNWG264sgJTJrWiTBnmnbIZzhnJuSAyp1niqbXCUO24NsZ2JDaUDQE5nnWhjjH4PG1C93b4TQlOez9p7yft_aQnPx1zd2QK7_2_fSG05pL9AbyTYU4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>RF-Care: RFID-Based Human Pose Estimation for Nursing-Care Applications Under Visual Occlusion</title><source>IEEE Electronic Library (IEL)</source><creator>Liu, Jixiao ; Xia, Zihou ; Liu, Junyi ; Guo, Shijie</creator><creatorcontrib>Liu, Jixiao ; Xia, Zihou ; Liu, Junyi ; Guo, Shijie</creatorcontrib><description>Occlusion and environmental light changes often exist in intelligent care scenarios. Human posture sensing through vision alone is prone to misjudgment, so human posture sensing methods other than vision are needed. This article proposes RF-Care, an RFID-based human pose estimation system that avoids these problems. RF-Care uses the phase difference between RFID tags on the limbs and antennas to determine body joint positions and motion. It requires only a wearable RFID tag array and a simple RF antenna setup. We introduce a fine-grained limb tracking algorithm and dual-antenna 3-D pose estimation method to achieve accurate results despite occlusions. Experiments validate RF-Care's performance for subjects standing or lying in bed under blankets/quilts. Compared to Kinect 2.0, the mean position error is about 4 cm without occlusion. The standard deviation (STD) is about 3.4 cm when visually occluded. RF-Care efficiently monitors full-body posture regardless of impediments, benefiting intelligent nursing care and other applications requiring accurate real-time pose measurement.</description><identifier>ISSN: 1530-437X</identifier><identifier>EISSN: 1558-1748</identifier><identifier>DOI: 10.1109/JSEN.2024.3407962</identifier><identifier>CODEN: ISJEAZ</identifier><language>eng</language><publisher>IEEE</publisher><subject>Accuracy ; Human body posture ; Legged locomotion ; phase difference ; Pose estimation ; radio frequency identification (RFID) ; RFID tags ; Sensors ; Tracking ; Visualization ; wearable devices</subject><ispartof>IEEE sensors journal, 2024-11, Vol.24 (21), p.35359-35366</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c637-b95831b9a4a48b5023798238a3ec8bd0f31f4517f2d6e2bb5a29c49aabb950a23</cites><orcidid>0000-0002-0355-9980 ; 0000-0002-1335-2852 ; 0009-0001-4262-6031</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/10559947$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,776,780,792,27901,27902,54733</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/10559947$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Liu, Jixiao</creatorcontrib><creatorcontrib>Xia, Zihou</creatorcontrib><creatorcontrib>Liu, Junyi</creatorcontrib><creatorcontrib>Guo, Shijie</creatorcontrib><title>RF-Care: RFID-Based Human Pose Estimation for Nursing-Care Applications Under Visual Occlusion</title><title>IEEE sensors journal</title><addtitle>JSEN</addtitle><description>Occlusion and environmental light changes often exist in intelligent care scenarios. Human posture sensing through vision alone is prone to misjudgment, so human posture sensing methods other than vision are needed. This article proposes RF-Care, an RFID-based human pose estimation system that avoids these problems. RF-Care uses the phase difference between RFID tags on the limbs and antennas to determine body joint positions and motion. It requires only a wearable RFID tag array and a simple RF antenna setup. We introduce a fine-grained limb tracking algorithm and dual-antenna 3-D pose estimation method to achieve accurate results despite occlusions. Experiments validate RF-Care's performance for subjects standing or lying in bed under blankets/quilts. Compared to Kinect 2.0, the mean position error is about 4 cm without occlusion. The standard deviation (STD) is about 3.4 cm when visually occluded. RF-Care efficiently monitors full-body posture regardless of impediments, benefiting intelligent nursing care and other applications requiring accurate real-time pose measurement.</description><subject>Accuracy</subject><subject>Human body posture</subject><subject>Legged locomotion</subject><subject>phase difference</subject><subject>Pose estimation</subject><subject>radio frequency identification (RFID)</subject><subject>RFID tags</subject><subject>Sensors</subject><subject>Tracking</subject><subject>Visualization</subject><subject>wearable devices</subject><issn>1530-437X</issn><issn>1558-1748</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNpNkE1OwzAQRi0EEqVwACQWvoCLf2ObXSktLapaVApiRWQ7DgpKk8huFtyepO2C1YzmmzcaPQBuCR4RgvX9y9t0NaKY8hHjWOqEnoEBEUIhIrk673uGEWfy8xJcxfiDMdFSyAH42szQxAT_ADezxRN6NNFncN7uTAVf6-jhNO6LndkXdQXzOsBVG2JRfR8QOG6asnCHMML3KvMBfhSxNSVcO1e2sZtfg4vclNHfnOoQbGfT7WSOluvnxWS8RC5hElktFCNWG264sgJTJrWiTBnmnbIZzhnJuSAyp1niqbXCUO24NsZ2JDaUDQE5nnWhjjH4PG1C93b4TQlOez9p7yft_aQnPx1zd2QK7_2_fSG05pL9AbyTYU4</recordid><startdate>20241101</startdate><enddate>20241101</enddate><creator>Liu, Jixiao</creator><creator>Xia, Zihou</creator><creator>Liu, Junyi</creator><creator>Guo, Shijie</creator><general>IEEE</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0002-0355-9980</orcidid><orcidid>https://orcid.org/0000-0002-1335-2852</orcidid><orcidid>https://orcid.org/0009-0001-4262-6031</orcidid></search><sort><creationdate>20241101</creationdate><title>RF-Care: RFID-Based Human Pose Estimation for Nursing-Care Applications Under Visual Occlusion</title><author>Liu, Jixiao ; Xia, Zihou ; Liu, Junyi ; Guo, Shijie</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c637-b95831b9a4a48b5023798238a3ec8bd0f31f4517f2d6e2bb5a29c49aabb950a23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Accuracy</topic><topic>Human body posture</topic><topic>Legged locomotion</topic><topic>phase difference</topic><topic>Pose estimation</topic><topic>radio frequency identification (RFID)</topic><topic>RFID tags</topic><topic>Sensors</topic><topic>Tracking</topic><topic>Visualization</topic><topic>wearable devices</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Liu, Jixiao</creatorcontrib><creatorcontrib>Xia, Zihou</creatorcontrib><creatorcontrib>Liu, Junyi</creatorcontrib><creatorcontrib>Guo, Shijie</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><jtitle>IEEE sensors journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Liu, Jixiao</au><au>Xia, Zihou</au><au>Liu, Junyi</au><au>Guo, Shijie</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>RF-Care: RFID-Based Human Pose Estimation for Nursing-Care Applications Under Visual Occlusion</atitle><jtitle>IEEE sensors journal</jtitle><stitle>JSEN</stitle><date>2024-11-01</date><risdate>2024</risdate><volume>24</volume><issue>21</issue><spage>35359</spage><epage>35366</epage><pages>35359-35366</pages><issn>1530-437X</issn><eissn>1558-1748</eissn><coden>ISJEAZ</coden><abstract>Occlusion and environmental light changes often exist in intelligent care scenarios. Human posture sensing through vision alone is prone to misjudgment, so human posture sensing methods other than vision are needed. This article proposes RF-Care, an RFID-based human pose estimation system that avoids these problems. RF-Care uses the phase difference between RFID tags on the limbs and antennas to determine body joint positions and motion. It requires only a wearable RFID tag array and a simple RF antenna setup. We introduce a fine-grained limb tracking algorithm and dual-antenna 3-D pose estimation method to achieve accurate results despite occlusions. Experiments validate RF-Care's performance for subjects standing or lying in bed under blankets/quilts. Compared to Kinect 2.0, the mean position error is about 4 cm without occlusion. The standard deviation (STD) is about 3.4 cm when visually occluded. RF-Care efficiently monitors full-body posture regardless of impediments, benefiting intelligent nursing care and other applications requiring accurate real-time pose measurement.</abstract><pub>IEEE</pub><doi>10.1109/JSEN.2024.3407962</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0002-0355-9980</orcidid><orcidid>https://orcid.org/0000-0002-1335-2852</orcidid><orcidid>https://orcid.org/0009-0001-4262-6031</orcidid></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 1530-437X |
ispartof | IEEE sensors journal, 2024-11, Vol.24 (21), p.35359-35366 |
issn | 1530-437X 1558-1748 |
language | eng |
recordid | cdi_crossref_primary_10_1109_JSEN_2024_3407962 |
source | IEEE Electronic Library (IEL) |
subjects | Accuracy Human body posture Legged locomotion phase difference Pose estimation radio frequency identification (RFID) RFID tags Sensors Tracking Visualization wearable devices |
title | RF-Care: RFID-Based Human Pose Estimation for Nursing-Care Applications Under Visual Occlusion |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T22%3A32%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=RF-Care:%20RFID-Based%20Human%20Pose%20Estimation%20for%20Nursing-Care%20Applications%20Under%20Visual%20Occlusion&rft.jtitle=IEEE%20sensors%20journal&rft.au=Liu,%20Jixiao&rft.date=2024-11-01&rft.volume=24&rft.issue=21&rft.spage=35359&rft.epage=35366&rft.pages=35359-35366&rft.issn=1530-437X&rft.eissn=1558-1748&rft.coden=ISJEAZ&rft_id=info:doi/10.1109/JSEN.2024.3407962&rft_dat=%3Ccrossref_RIE%3E10_1109_JSEN_2024_3407962%3C/crossref_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=10559947&rfr_iscdi=true |