Proposal of a Skin Temperature Measurement System Based on Digital Thermometers

The representation of temperature measurement methods is worldwide, as is the number of industries that use them. Their utilization allows one to assess the object's temperature relatively accurately and further according to the defined dependencies to evaluate its condition. In the medical sec...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE access 2023, Vol.11, p.25050-25062
Hauptverfasser: Gaspar, Gabriel, Dudak, Juraj, Mikolajcikova, Magdalena, Gurin, Daniel
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 25062
container_issue
container_start_page 25050
container_title IEEE access
container_volume 11
creator Gaspar, Gabriel
Dudak, Juraj
Mikolajcikova, Magdalena
Gurin, Daniel
description The representation of temperature measurement methods is worldwide, as is the number of industries that use them. Their utilization allows one to assess the object's temperature relatively accurately and further according to the defined dependencies to evaluate its condition. In the medical sector, non-invasive temperature measurement methods are increasingly gaining ground. In our work, we focus on the design of a system for measuring skin temperature using digital DS18B20 thermometers. The technical design consists of the mechanical design of the sensor housing based on the requirements of healthcare professionals, the design of a 1-wire bus active pull-up driver with improved features, and the user software, allowing for the future implementation in various, not necessarily medical environments. The main contribution lies in optimizing the hardware design concerning the components' parameters and surge protection. In the medical field, the aim was to compare changes in skin temperature in the shoulder region depending on the type of muscle contraction during static and dynamic components of movement and to record the thermal work of the muscle during activity in real-time. We experimented by applying temperature sensors to the deltoid muscle of the dominant limb in a temperature environment of 25.76 °C. In the experimental measurements, we demonstrated that during the three selected muscle work movements, there was a temperature change in the respective regions of the deltoid muscle for each of the three, which the temperature sensors could capture. Our results were statistically significant when comparing the baseline values, and the highest temperature reached. The level of significance \alpha \leqslant 0.05 and a low percentage of errors were valid.
doi_str_mv 10.1109/ACCESS.2023.3255511
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1109_ACCESS_2023_3255511</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>10065470</ieee_id><doaj_id>oai_doaj_org_article_913ddef2d030461bab4fa36bb79c7328</doaj_id><sourcerecordid>2787704304</sourcerecordid><originalsourceid>FETCH-LOGICAL-c409t-5f9a0b6d4a75f4d5ca8ac3d2dcc616c43c19fbb6af1fcc4735a6b3659298c3a83</originalsourceid><addsrcrecordid>eNpNkU9rGzEQxZfSQEPiT5AeBD3b0X-tjqmbpAYXB-ycxaw0ctf1Wq60PuTbd901IXN5wzC_NwOvqu4YnTFG7f3DfP64Xs845WImuFKKsU_VNWfaToUS-vOH_ks1KWVHh6qHkTLX1eolp2MqsCcpEiDrP-2BbLA7Yob-lJH8QiiDdnjoyfqt9NiR71AwkHQgP9pt2w_k5jfmLnXYYy631VWEfcHJRW-q16fHzfzndLl6XswfllMvqe2nKlqgjQ4SjIoyKA81eBF48F4z7aXwzMam0RBZ9F4aoUA3QivLbe0F1OKmWoy-IcHOHXPbQX5zCVr3f5Dy1kHuW79HZ5kIASMPVFCpWQONjCB00xjrjeBnr2-j1zGnvycsvdulUz4M7ztuamOoHMBhS4xbPqdSMsb3q4y6cxBuDMKdg3CXIAbq60i1iPiBoFpJQ8U_GA-Elw</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2787704304</pqid></control><display><type>article</type><title>Proposal of a Skin Temperature Measurement System Based on Digital Thermometers</title><source>IEEE Open Access Journals</source><source>DOAJ Directory of Open Access Journals</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Gaspar, Gabriel ; Dudak, Juraj ; Mikolajcikova, Magdalena ; Gurin, Daniel</creator><creatorcontrib>Gaspar, Gabriel ; Dudak, Juraj ; Mikolajcikova, Magdalena ; Gurin, Daniel</creatorcontrib><description>The representation of temperature measurement methods is worldwide, as is the number of industries that use them. Their utilization allows one to assess the object's temperature relatively accurately and further according to the defined dependencies to evaluate its condition. In the medical sector, non-invasive temperature measurement methods are increasingly gaining ground. In our work, we focus on the design of a system for measuring skin temperature using digital DS18B20 thermometers. The technical design consists of the mechanical design of the sensor housing based on the requirements of healthcare professionals, the design of a 1-wire bus active pull-up driver with improved features, and the user software, allowing for the future implementation in various, not necessarily medical environments. The main contribution lies in optimizing the hardware design concerning the components' parameters and surge protection. In the medical field, the aim was to compare changes in skin temperature in the shoulder region depending on the type of muscle contraction during static and dynamic components of movement and to record the thermal work of the muscle during activity in real-time. We experimented by applying temperature sensors to the deltoid muscle of the dominant limb in a temperature environment of 25.76 °C. In the experimental measurements, we demonstrated that during the three selected muscle work movements, there was a temperature change in the respective regions of the deltoid muscle for each of the three, which the temperature sensors could capture. Our results were statistically significant when comparing the baseline values, and the highest temperature reached. The level of significance &lt;inline-formula&gt; &lt;tex-math notation="LaTeX"&gt;\alpha \leqslant 0.05 &lt;/tex-math&gt;&lt;/inline-formula&gt; and a low percentage of errors were valid.</description><identifier>ISSN: 2169-3536</identifier><identifier>EISSN: 2169-3536</identifier><identifier>DOI: 10.1109/ACCESS.2023.3255511</identifier><identifier>CODEN: IAECCG</identifier><language>eng</language><publisher>Piscataway: IEEE</publisher><subject>1-wire ; Design optimization ; Design parameters ; measurement ; Measurement methods ; microcontroller ; Muscles ; Muscular function ; non-invasive measurement ; Noninvasive treatment ; Registers ; Sensors ; Skin temperature ; system ; Temperature ; Temperature measurement ; Temperature sensors ; thermodiagnostics ; Thermodynamics ; Thermometers ; Thermometry ; thermoregulation</subject><ispartof>IEEE access, 2023, Vol.11, p.25050-25062</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2023</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c409t-5f9a0b6d4a75f4d5ca8ac3d2dcc616c43c19fbb6af1fcc4735a6b3659298c3a83</citedby><cites>FETCH-LOGICAL-c409t-5f9a0b6d4a75f4d5ca8ac3d2dcc616c43c19fbb6af1fcc4735a6b3659298c3a83</cites><orcidid>0000-0002-5570-5150 ; 0000-0001-8796-9110 ; 0009-0009-7398-1659 ; 0000-0002-2550-1675</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/10065470$$EHTML$$P50$$Gieee$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,864,2102,4024,27633,27923,27924,27925,54933</link.rule.ids></links><search><creatorcontrib>Gaspar, Gabriel</creatorcontrib><creatorcontrib>Dudak, Juraj</creatorcontrib><creatorcontrib>Mikolajcikova, Magdalena</creatorcontrib><creatorcontrib>Gurin, Daniel</creatorcontrib><title>Proposal of a Skin Temperature Measurement System Based on Digital Thermometers</title><title>IEEE access</title><addtitle>Access</addtitle><description>The representation of temperature measurement methods is worldwide, as is the number of industries that use them. Their utilization allows one to assess the object's temperature relatively accurately and further according to the defined dependencies to evaluate its condition. In the medical sector, non-invasive temperature measurement methods are increasingly gaining ground. In our work, we focus on the design of a system for measuring skin temperature using digital DS18B20 thermometers. The technical design consists of the mechanical design of the sensor housing based on the requirements of healthcare professionals, the design of a 1-wire bus active pull-up driver with improved features, and the user software, allowing for the future implementation in various, not necessarily medical environments. The main contribution lies in optimizing the hardware design concerning the components' parameters and surge protection. In the medical field, the aim was to compare changes in skin temperature in the shoulder region depending on the type of muscle contraction during static and dynamic components of movement and to record the thermal work of the muscle during activity in real-time. We experimented by applying temperature sensors to the deltoid muscle of the dominant limb in a temperature environment of 25.76 °C. In the experimental measurements, we demonstrated that during the three selected muscle work movements, there was a temperature change in the respective regions of the deltoid muscle for each of the three, which the temperature sensors could capture. Our results were statistically significant when comparing the baseline values, and the highest temperature reached. The level of significance &lt;inline-formula&gt; &lt;tex-math notation="LaTeX"&gt;\alpha \leqslant 0.05 &lt;/tex-math&gt;&lt;/inline-formula&gt; and a low percentage of errors were valid.</description><subject>1-wire</subject><subject>Design optimization</subject><subject>Design parameters</subject><subject>measurement</subject><subject>Measurement methods</subject><subject>microcontroller</subject><subject>Muscles</subject><subject>Muscular function</subject><subject>non-invasive measurement</subject><subject>Noninvasive treatment</subject><subject>Registers</subject><subject>Sensors</subject><subject>Skin temperature</subject><subject>system</subject><subject>Temperature</subject><subject>Temperature measurement</subject><subject>Temperature sensors</subject><subject>thermodiagnostics</subject><subject>Thermodynamics</subject><subject>Thermometers</subject><subject>Thermometry</subject><subject>thermoregulation</subject><issn>2169-3536</issn><issn>2169-3536</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><sourceid>ESBDL</sourceid><sourceid>RIE</sourceid><sourceid>DOA</sourceid><recordid>eNpNkU9rGzEQxZfSQEPiT5AeBD3b0X-tjqmbpAYXB-ycxaw0ctf1Wq60PuTbd901IXN5wzC_NwOvqu4YnTFG7f3DfP64Xs845WImuFKKsU_VNWfaToUS-vOH_ks1KWVHh6qHkTLX1eolp2MqsCcpEiDrP-2BbLA7Yob-lJH8QiiDdnjoyfqt9NiR71AwkHQgP9pt2w_k5jfmLnXYYy631VWEfcHJRW-q16fHzfzndLl6XswfllMvqe2nKlqgjQ4SjIoyKA81eBF48F4z7aXwzMam0RBZ9F4aoUA3QivLbe0F1OKmWoy-IcHOHXPbQX5zCVr3f5Dy1kHuW79HZ5kIASMPVFCpWQONjCB00xjrjeBnr2-j1zGnvycsvdulUz4M7ztuamOoHMBhS4xbPqdSMsb3q4y6cxBuDMKdg3CXIAbq60i1iPiBoFpJQ8U_GA-Elw</recordid><startdate>2023</startdate><enddate>2023</enddate><creator>Gaspar, Gabriel</creator><creator>Dudak, Juraj</creator><creator>Mikolajcikova, Magdalena</creator><creator>Gurin, Daniel</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>97E</scope><scope>ESBDL</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SC</scope><scope>7SP</scope><scope>7SR</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>JQ2</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0002-5570-5150</orcidid><orcidid>https://orcid.org/0000-0001-8796-9110</orcidid><orcidid>https://orcid.org/0009-0009-7398-1659</orcidid><orcidid>https://orcid.org/0000-0002-2550-1675</orcidid></search><sort><creationdate>2023</creationdate><title>Proposal of a Skin Temperature Measurement System Based on Digital Thermometers</title><author>Gaspar, Gabriel ; Dudak, Juraj ; Mikolajcikova, Magdalena ; Gurin, Daniel</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c409t-5f9a0b6d4a75f4d5ca8ac3d2dcc616c43c19fbb6af1fcc4735a6b3659298c3a83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>1-wire</topic><topic>Design optimization</topic><topic>Design parameters</topic><topic>measurement</topic><topic>Measurement methods</topic><topic>microcontroller</topic><topic>Muscles</topic><topic>Muscular function</topic><topic>non-invasive measurement</topic><topic>Noninvasive treatment</topic><topic>Registers</topic><topic>Sensors</topic><topic>Skin temperature</topic><topic>system</topic><topic>Temperature</topic><topic>Temperature measurement</topic><topic>Temperature sensors</topic><topic>thermodiagnostics</topic><topic>Thermodynamics</topic><topic>Thermometers</topic><topic>Thermometry</topic><topic>thermoregulation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gaspar, Gabriel</creatorcontrib><creatorcontrib>Dudak, Juraj</creatorcontrib><creatorcontrib>Mikolajcikova, Magdalena</creatorcontrib><creatorcontrib>Gurin, Daniel</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE Open Access Journals</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><collection>Computer and Information Systems Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>IEEE access</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gaspar, Gabriel</au><au>Dudak, Juraj</au><au>Mikolajcikova, Magdalena</au><au>Gurin, Daniel</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Proposal of a Skin Temperature Measurement System Based on Digital Thermometers</atitle><jtitle>IEEE access</jtitle><stitle>Access</stitle><date>2023</date><risdate>2023</risdate><volume>11</volume><spage>25050</spage><epage>25062</epage><pages>25050-25062</pages><issn>2169-3536</issn><eissn>2169-3536</eissn><coden>IAECCG</coden><abstract>The representation of temperature measurement methods is worldwide, as is the number of industries that use them. Their utilization allows one to assess the object's temperature relatively accurately and further according to the defined dependencies to evaluate its condition. In the medical sector, non-invasive temperature measurement methods are increasingly gaining ground. In our work, we focus on the design of a system for measuring skin temperature using digital DS18B20 thermometers. The technical design consists of the mechanical design of the sensor housing based on the requirements of healthcare professionals, the design of a 1-wire bus active pull-up driver with improved features, and the user software, allowing for the future implementation in various, not necessarily medical environments. The main contribution lies in optimizing the hardware design concerning the components' parameters and surge protection. In the medical field, the aim was to compare changes in skin temperature in the shoulder region depending on the type of muscle contraction during static and dynamic components of movement and to record the thermal work of the muscle during activity in real-time. We experimented by applying temperature sensors to the deltoid muscle of the dominant limb in a temperature environment of 25.76 °C. In the experimental measurements, we demonstrated that during the three selected muscle work movements, there was a temperature change in the respective regions of the deltoid muscle for each of the three, which the temperature sensors could capture. Our results were statistically significant when comparing the baseline values, and the highest temperature reached. The level of significance &lt;inline-formula&gt; &lt;tex-math notation="LaTeX"&gt;\alpha \leqslant 0.05 &lt;/tex-math&gt;&lt;/inline-formula&gt; and a low percentage of errors were valid.</abstract><cop>Piscataway</cop><pub>IEEE</pub><doi>10.1109/ACCESS.2023.3255511</doi><tpages>13</tpages><orcidid>https://orcid.org/0000-0002-5570-5150</orcidid><orcidid>https://orcid.org/0000-0001-8796-9110</orcidid><orcidid>https://orcid.org/0009-0009-7398-1659</orcidid><orcidid>https://orcid.org/0000-0002-2550-1675</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2169-3536
ispartof IEEE access, 2023, Vol.11, p.25050-25062
issn 2169-3536
2169-3536
language eng
recordid cdi_crossref_primary_10_1109_ACCESS_2023_3255511
source IEEE Open Access Journals; DOAJ Directory of Open Access Journals; EZB-FREE-00999 freely available EZB journals
subjects 1-wire
Design optimization
Design parameters
measurement
Measurement methods
microcontroller
Muscles
Muscular function
non-invasive measurement
Noninvasive treatment
Registers
Sensors
Skin temperature
system
Temperature
Temperature measurement
Temperature sensors
thermodiagnostics
Thermodynamics
Thermometers
Thermometry
thermoregulation
title Proposal of a Skin Temperature Measurement System Based on Digital Thermometers
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T11%3A25%3A20IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Proposal%20of%20a%20Skin%20Temperature%20Measurement%20System%20Based%20on%20Digital%20Thermometers&rft.jtitle=IEEE%20access&rft.au=Gaspar,%20Gabriel&rft.date=2023&rft.volume=11&rft.spage=25050&rft.epage=25062&rft.pages=25050-25062&rft.issn=2169-3536&rft.eissn=2169-3536&rft.coden=IAECCG&rft_id=info:doi/10.1109/ACCESS.2023.3255511&rft_dat=%3Cproquest_cross%3E2787704304%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2787704304&rft_id=info:pmid/&rft_ieee_id=10065470&rft_doaj_id=oai_doaj_org_article_913ddef2d030461bab4fa36bb79c7328&rfr_iscdi=true