Design and performance improvements in power transformers using ribbon cable
An advanced core-form power transformer with significantly lower losses and weight has been produced and brought to commercial status. First, a number of designs and design studies were made on actual medium power transformer specifications. Several windability models were built, as well as a comple...
Gespeichert in:
Veröffentlicht in: | IEEE Transactions on Power Delivery 1995-04, Vol.10 (2), p.869-879 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 879 |
---|---|
container_issue | 2 |
container_start_page | 869 |
container_title | IEEE Transactions on Power Delivery |
container_volume | 10 |
creator | Girgis, R.S. Baldwin, C.J. Kennedy, W.N. Monaco, S. Lindgren, S.R. Holm, R.D. Kothmann, R.E. |
description | An advanced core-form power transformer with significantly lower losses and weight has been produced and brought to commercial status. First, a number of designs and design studies were made on actual medium power transformer specifications. Several windability models were built, as well as a complete 250 kVA core-form advanced power transformer model to develop the new manufacturing technology and to verify many performance characteristics of the new technology. Then extensive thermal, short-circuit strength, and loss studies were made. Finally, a cooperating electric utility ordered two units, one conventional and one advanced, to the same specification to provide ideal conditions for the verification of the new technology. Construction and test of the prototype proceeded without incident. Full verification was achieved for all aspects of the technology: dielectric design, thermal design, short-circuit strength, loss performance, impedance, noise level, and manufacturability. The prototype was installed and energized in 1991 and continues in operation today. Subsequently, other units were built and tested, with performance results confirming the technology.< > |
doi_str_mv | 10.1109/61.400843 |
format | Article |
fullrecord | <record><control><sourceid>proquest_RIE</sourceid><recordid>TN_cdi_crossref_primary_10_1109_61_400843</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>400843</ieee_id><sourcerecordid>28236484</sourcerecordid><originalsourceid>FETCH-LOGICAL-c262t-b7380e123c974a7843000c556f91e307033acd6d3bea1e0208d4194d0e75b3b3</originalsourceid><addsrcrecordid>eNo90D1PwzAQBmALgUQpDKxMnpAYUs6xEycjKp9SJZbuluNcilFiB9sF8e9JlYrphnt0Hy8h1wxWjEF9X7KVAKgEPyELVnOZiRyqU7KAqiqyqpbynFzE-AkAAmpYkM0jRrtzVLuWjhg6HwbtDFI7jMF_44AuRWodHf0PBpqCdvFgMES6j9btaLBN4x01uunxkpx1uo94daxLsn1-2q5fs837y9v6YZOZvMxT1kheAbKcm1oKLadjp3NMUZRdzZCDBM61acuWN6gZwvRAK1gtWkBZNLzhS0LnsT4mq6KxCc2H8c6hSaoUIpcTuZ3J9MXXHmNSg40G-1479Puo8irnpZg2L8ndDE3wMQbs1BjsoMOvYqAOiaqSqTnRyd7M1iLivzs2_wD8mHAn</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>28236484</pqid></control><display><type>article</type><title>Design and performance improvements in power transformers using ribbon cable</title><source>IEEE Electronic Library (IEL)</source><creator>Girgis, R.S. ; Baldwin, C.J. ; Kennedy, W.N. ; Monaco, S. ; Lindgren, S.R. ; Holm, R.D. ; Kothmann, R.E.</creator><creatorcontrib>Girgis, R.S. ; Baldwin, C.J. ; Kennedy, W.N. ; Monaco, S. ; Lindgren, S.R. ; Holm, R.D. ; Kothmann, R.E.</creatorcontrib><description>An advanced core-form power transformer with significantly lower losses and weight has been produced and brought to commercial status. First, a number of designs and design studies were made on actual medium power transformer specifications. Several windability models were built, as well as a complete 250 kVA core-form advanced power transformer model to develop the new manufacturing technology and to verify many performance characteristics of the new technology. Then extensive thermal, short-circuit strength, and loss studies were made. Finally, a cooperating electric utility ordered two units, one conventional and one advanced, to the same specification to provide ideal conditions for the verification of the new technology. Construction and test of the prototype proceeded without incident. Full verification was achieved for all aspects of the technology: dielectric design, thermal design, short-circuit strength, loss performance, impedance, noise level, and manufacturability. The prototype was installed and energized in 1991 and continues in operation today. Subsequently, other units were built and tested, with performance results confirming the technology.< ></description><identifier>ISSN: 0885-8977</identifier><identifier>EISSN: 1937-4208</identifier><identifier>DOI: 10.1109/61.400843</identifier><identifier>CODEN: ITPDE5</identifier><language>eng</language><publisher>United States: IEEE</publisher><subject>COMMERCIALIZATION ; Dielectric losses ; HVAC SYSTEMS ; Impedance ; Noise level ; Performance loss ; POWER DISTRIBUTION SYSTEMS ; Power industry ; Power transformers ; POWER TRANSMISSION AND DISTRIBUTION ; Prototypes ; Testing ; Transformer cores ; TRANSFORMERS ; Virtual manufacturing</subject><ispartof>IEEE Transactions on Power Delivery, 1995-04, Vol.10 (2), p.869-879</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c262t-b7380e123c974a7843000c556f91e307033acd6d3bea1e0208d4194d0e75b3b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/400843$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>315,782,786,798,887,27933,27934,54767</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/400843$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc><backlink>$$Uhttps://www.osti.gov/biblio/64427$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Girgis, R.S.</creatorcontrib><creatorcontrib>Baldwin, C.J.</creatorcontrib><creatorcontrib>Kennedy, W.N.</creatorcontrib><creatorcontrib>Monaco, S.</creatorcontrib><creatorcontrib>Lindgren, S.R.</creatorcontrib><creatorcontrib>Holm, R.D.</creatorcontrib><creatorcontrib>Kothmann, R.E.</creatorcontrib><title>Design and performance improvements in power transformers using ribbon cable</title><title>IEEE Transactions on Power Delivery</title><addtitle>TPWRD</addtitle><description>An advanced core-form power transformer with significantly lower losses and weight has been produced and brought to commercial status. First, a number of designs and design studies were made on actual medium power transformer specifications. Several windability models were built, as well as a complete 250 kVA core-form advanced power transformer model to develop the new manufacturing technology and to verify many performance characteristics of the new technology. Then extensive thermal, short-circuit strength, and loss studies were made. Finally, a cooperating electric utility ordered two units, one conventional and one advanced, to the same specification to provide ideal conditions for the verification of the new technology. Construction and test of the prototype proceeded without incident. Full verification was achieved for all aspects of the technology: dielectric design, thermal design, short-circuit strength, loss performance, impedance, noise level, and manufacturability. The prototype was installed and energized in 1991 and continues in operation today. Subsequently, other units were built and tested, with performance results confirming the technology.< ></description><subject>COMMERCIALIZATION</subject><subject>Dielectric losses</subject><subject>HVAC SYSTEMS</subject><subject>Impedance</subject><subject>Noise level</subject><subject>Performance loss</subject><subject>POWER DISTRIBUTION SYSTEMS</subject><subject>Power industry</subject><subject>Power transformers</subject><subject>POWER TRANSMISSION AND DISTRIBUTION</subject><subject>Prototypes</subject><subject>Testing</subject><subject>Transformer cores</subject><subject>TRANSFORMERS</subject><subject>Virtual manufacturing</subject><issn>0885-8977</issn><issn>1937-4208</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1995</creationdate><recordtype>article</recordtype><recordid>eNo90D1PwzAQBmALgUQpDKxMnpAYUs6xEycjKp9SJZbuluNcilFiB9sF8e9JlYrphnt0Hy8h1wxWjEF9X7KVAKgEPyELVnOZiRyqU7KAqiqyqpbynFzE-AkAAmpYkM0jRrtzVLuWjhg6HwbtDFI7jMF_44AuRWodHf0PBpqCdvFgMES6j9btaLBN4x01uunxkpx1uo94daxLsn1-2q5fs837y9v6YZOZvMxT1kheAbKcm1oKLadjp3NMUZRdzZCDBM61acuWN6gZwvRAK1gtWkBZNLzhS0LnsT4mq6KxCc2H8c6hSaoUIpcTuZ3J9MXXHmNSg40G-1479Puo8irnpZg2L8ndDE3wMQbs1BjsoMOvYqAOiaqSqTnRyd7M1iLivzs2_wD8mHAn</recordid><startdate>19950401</startdate><enddate>19950401</enddate><creator>Girgis, R.S.</creator><creator>Baldwin, C.J.</creator><creator>Kennedy, W.N.</creator><creator>Monaco, S.</creator><creator>Lindgren, S.R.</creator><creator>Holm, R.D.</creator><creator>Kothmann, R.E.</creator><general>IEEE</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>8FD</scope><scope>L7M</scope><scope>OTOTI</scope></search><sort><creationdate>19950401</creationdate><title>Design and performance improvements in power transformers using ribbon cable</title><author>Girgis, R.S. ; Baldwin, C.J. ; Kennedy, W.N. ; Monaco, S. ; Lindgren, S.R. ; Holm, R.D. ; Kothmann, R.E.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c262t-b7380e123c974a7843000c556f91e307033acd6d3bea1e0208d4194d0e75b3b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1995</creationdate><topic>COMMERCIALIZATION</topic><topic>Dielectric losses</topic><topic>HVAC SYSTEMS</topic><topic>Impedance</topic><topic>Noise level</topic><topic>Performance loss</topic><topic>POWER DISTRIBUTION SYSTEMS</topic><topic>Power industry</topic><topic>Power transformers</topic><topic>POWER TRANSMISSION AND DISTRIBUTION</topic><topic>Prototypes</topic><topic>Testing</topic><topic>Transformer cores</topic><topic>TRANSFORMERS</topic><topic>Virtual manufacturing</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Girgis, R.S.</creatorcontrib><creatorcontrib>Baldwin, C.J.</creatorcontrib><creatorcontrib>Kennedy, W.N.</creatorcontrib><creatorcontrib>Monaco, S.</creatorcontrib><creatorcontrib>Lindgren, S.R.</creatorcontrib><creatorcontrib>Holm, R.D.</creatorcontrib><creatorcontrib>Kothmann, R.E.</creatorcontrib><collection>CrossRef</collection><collection>Electronics & Communications Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>OSTI.GOV</collection><jtitle>IEEE Transactions on Power Delivery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Girgis, R.S.</au><au>Baldwin, C.J.</au><au>Kennedy, W.N.</au><au>Monaco, S.</au><au>Lindgren, S.R.</au><au>Holm, R.D.</au><au>Kothmann, R.E.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Design and performance improvements in power transformers using ribbon cable</atitle><jtitle>IEEE Transactions on Power Delivery</jtitle><stitle>TPWRD</stitle><date>1995-04-01</date><risdate>1995</risdate><volume>10</volume><issue>2</issue><spage>869</spage><epage>879</epage><pages>869-879</pages><issn>0885-8977</issn><eissn>1937-4208</eissn><coden>ITPDE5</coden><abstract>An advanced core-form power transformer with significantly lower losses and weight has been produced and brought to commercial status. First, a number of designs and design studies were made on actual medium power transformer specifications. Several windability models were built, as well as a complete 250 kVA core-form advanced power transformer model to develop the new manufacturing technology and to verify many performance characteristics of the new technology. Then extensive thermal, short-circuit strength, and loss studies were made. Finally, a cooperating electric utility ordered two units, one conventional and one advanced, to the same specification to provide ideal conditions for the verification of the new technology. Construction and test of the prototype proceeded without incident. Full verification was achieved for all aspects of the technology: dielectric design, thermal design, short-circuit strength, loss performance, impedance, noise level, and manufacturability. The prototype was installed and energized in 1991 and continues in operation today. Subsequently, other units were built and tested, with performance results confirming the technology.< ></abstract><cop>United States</cop><pub>IEEE</pub><doi>10.1109/61.400843</doi><tpages>11</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 0885-8977 |
ispartof | IEEE Transactions on Power Delivery, 1995-04, Vol.10 (2), p.869-879 |
issn | 0885-8977 1937-4208 |
language | eng |
recordid | cdi_crossref_primary_10_1109_61_400843 |
source | IEEE Electronic Library (IEL) |
subjects | COMMERCIALIZATION Dielectric losses HVAC SYSTEMS Impedance Noise level Performance loss POWER DISTRIBUTION SYSTEMS Power industry Power transformers POWER TRANSMISSION AND DISTRIBUTION Prototypes Testing Transformer cores TRANSFORMERS Virtual manufacturing |
title | Design and performance improvements in power transformers using ribbon cable |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-02T22%3A14%3A06IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Design%20and%20performance%20improvements%20in%20power%20transformers%20using%20ribbon%20cable&rft.jtitle=IEEE%20Transactions%20on%20Power%20Delivery&rft.au=Girgis,%20R.S.&rft.date=1995-04-01&rft.volume=10&rft.issue=2&rft.spage=869&rft.epage=879&rft.pages=869-879&rft.issn=0885-8977&rft.eissn=1937-4208&rft.coden=ITPDE5&rft_id=info:doi/10.1109/61.400843&rft_dat=%3Cproquest_RIE%3E28236484%3C/proquest_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=28236484&rft_id=info:pmid/&rft_ieee_id=400843&rfr_iscdi=true |