Local drug delivery catheters: functional comparison of porous and microporous designs

BACKGROUNDThe porous (Wolinski) balloon was designed to allow local delivery of compounds targeted to inhibit postintervention restenosis; however, successful use of the device has been hampered by arterial trauma caused by the balloon itself. This study utilized several experimental systems to asse...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Coronary artery disease 1993-05, Vol.4 (5), p.469-476
Hauptverfasser: Lambert, Charles R, Leone, James E, Rowland, Stephen M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 476
container_issue 5
container_start_page 469
container_title Coronary artery disease
container_volume 4
creator Lambert, Charles R
Leone, James E
Rowland, Stephen M
description BACKGROUNDThe porous (Wolinski) balloon was designed to allow local delivery of compounds targeted to inhibit postintervention restenosis; however, successful use of the device has been hampered by arterial trauma caused by the balloon itself. This study utilized several experimental systems to assess the functional characteristics of the porous balloon catheter. This information was utilized to design and test a new microporous infusion catheter for local intra-arterial drug delivery. METHODSFlow characteristics in fluid and semisolid media as well as arterial trauma by light and electron microscopy were documented for the porous and microporous balloons. In addition, the efficacy of methylene blue delivery in situ and in vitro was documented and quantified for the microporous design. RESULTSThe porous balloon exhibits flow characteristics consistent with orifice-related streaming that produces arterial trauma. By maximizing external balloon-pore density and minimizing pore size, the microporous design minimizes streaming in test systems. This is manifested by minimal arterial trauma when applied to intact arteries. The microporous catheter is effective for dye delivery both in situ and in vivo. CONCLUSIONSThe microporous catheter design offers improved functional characteristics when compared with the porous balloon for local intra-arterial drug delivery.
doi_str_mv 10.1097/00019501-199305000-00011
format Article
fullrecord <record><control><sourceid>pubmed_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1097_00019501_199305000_00011</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>8261224</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2691-55dd548e7315ae096807664afda0ace91bbf18afaafcb7132a43b8877cefdb093</originalsourceid><addsrcrecordid>eNp1kctOwzAQRS0EKqXwCUj-gYAd27HNDlW8pEpsgG008aMNJHFlJ1T9e1JaumM1mjv3jkZnEMKU3FCi5S0hhGpBaEa1ZkSMbbaT6AmaUi5ZJhQjp2hKtOBZoXN1ji5S-hwdXEgxQROVFzTP-RR9LIKBBts4LLF1Tf3t4hYb6FeudzHdYT90pq9DN3pMaNcQ6xQ6HDxehxiGhKGzuK1NDIfeulQvu3SJzjw0yV0d6gy9Pz68zZ-zxevTy_x-kZm80DQTwlrBlZOMCnBEF4rIouDgLRAwTtOq8lSBB_CmkpTlwFmllJTGeVsRzWZI7feOF6QUnS_XsW4hbktKyh2p8o9UeST1K9Exer2ProeqdfYYPKAZ53w_34Rmx-KrGTYulisHTb8q_3sA-wFo43V2</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Local drug delivery catheters: functional comparison of porous and microporous designs</title><source>Journals@Ovid Ovid Autoload</source><source>MEDLINE</source><creator>Lambert, Charles R ; Leone, James E ; Rowland, Stephen M</creator><creatorcontrib>Lambert, Charles R ; Leone, James E ; Rowland, Stephen M</creatorcontrib><description>BACKGROUNDThe porous (Wolinski) balloon was designed to allow local delivery of compounds targeted to inhibit postintervention restenosis; however, successful use of the device has been hampered by arterial trauma caused by the balloon itself. This study utilized several experimental systems to assess the functional characteristics of the porous balloon catheter. This information was utilized to design and test a new microporous infusion catheter for local intra-arterial drug delivery. METHODSFlow characteristics in fluid and semisolid media as well as arterial trauma by light and electron microscopy were documented for the porous and microporous balloons. In addition, the efficacy of methylene blue delivery in situ and in vitro was documented and quantified for the microporous design. RESULTSThe porous balloon exhibits flow characteristics consistent with orifice-related streaming that produces arterial trauma. By maximizing external balloon-pore density and minimizing pore size, the microporous design minimizes streaming in test systems. This is manifested by minimal arterial trauma when applied to intact arteries. The microporous catheter is effective for dye delivery both in situ and in vivo. CONCLUSIONSThe microporous catheter design offers improved functional characteristics when compared with the porous balloon for local intra-arterial drug delivery.</description><identifier>ISSN: 0954-6928</identifier><identifier>EISSN: 1473-5830</identifier><identifier>DOI: 10.1097/00019501-199305000-00011</identifier><identifier>PMID: 8261224</identifier><language>eng</language><publisher>England: Lippincott-Raven Publishers</publisher><subject>Animals ; Arteries - diagnostic imaging ; Arteries - injuries ; Catheterization, Peripheral - adverse effects ; Catheterization, Peripheral - instrumentation ; Dogs ; Infusions, Intra-Arterial - adverse effects ; Infusions, Intra-Arterial - instrumentation ; Models, Cardiovascular ; Pharmaceutical Preparations - administration &amp; dosage ; Porosity ; Ultrasonography ; Wounds and Injuries - pathology</subject><ispartof>Coronary artery disease, 1993-05, Vol.4 (5), p.469-476</ispartof><rights>Lippincott-Raven Publishers.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/8261224$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Lambert, Charles R</creatorcontrib><creatorcontrib>Leone, James E</creatorcontrib><creatorcontrib>Rowland, Stephen M</creatorcontrib><title>Local drug delivery catheters: functional comparison of porous and microporous designs</title><title>Coronary artery disease</title><addtitle>Coron Artery Dis</addtitle><description>BACKGROUNDThe porous (Wolinski) balloon was designed to allow local delivery of compounds targeted to inhibit postintervention restenosis; however, successful use of the device has been hampered by arterial trauma caused by the balloon itself. This study utilized several experimental systems to assess the functional characteristics of the porous balloon catheter. This information was utilized to design and test a new microporous infusion catheter for local intra-arterial drug delivery. METHODSFlow characteristics in fluid and semisolid media as well as arterial trauma by light and electron microscopy were documented for the porous and microporous balloons. In addition, the efficacy of methylene blue delivery in situ and in vitro was documented and quantified for the microporous design. RESULTSThe porous balloon exhibits flow characteristics consistent with orifice-related streaming that produces arterial trauma. By maximizing external balloon-pore density and minimizing pore size, the microporous design minimizes streaming in test systems. This is manifested by minimal arterial trauma when applied to intact arteries. The microporous catheter is effective for dye delivery both in situ and in vivo. CONCLUSIONSThe microporous catheter design offers improved functional characteristics when compared with the porous balloon for local intra-arterial drug delivery.</description><subject>Animals</subject><subject>Arteries - diagnostic imaging</subject><subject>Arteries - injuries</subject><subject>Catheterization, Peripheral - adverse effects</subject><subject>Catheterization, Peripheral - instrumentation</subject><subject>Dogs</subject><subject>Infusions, Intra-Arterial - adverse effects</subject><subject>Infusions, Intra-Arterial - instrumentation</subject><subject>Models, Cardiovascular</subject><subject>Pharmaceutical Preparations - administration &amp; dosage</subject><subject>Porosity</subject><subject>Ultrasonography</subject><subject>Wounds and Injuries - pathology</subject><issn>0954-6928</issn><issn>1473-5830</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1993</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kctOwzAQRS0EKqXwCUj-gYAd27HNDlW8pEpsgG008aMNJHFlJ1T9e1JaumM1mjv3jkZnEMKU3FCi5S0hhGpBaEa1ZkSMbbaT6AmaUi5ZJhQjp2hKtOBZoXN1ji5S-hwdXEgxQROVFzTP-RR9LIKBBts4LLF1Tf3t4hYb6FeudzHdYT90pq9DN3pMaNcQ6xQ6HDxehxiGhKGzuK1NDIfeulQvu3SJzjw0yV0d6gy9Pz68zZ-zxevTy_x-kZm80DQTwlrBlZOMCnBEF4rIouDgLRAwTtOq8lSBB_CmkpTlwFmllJTGeVsRzWZI7feOF6QUnS_XsW4hbktKyh2p8o9UeST1K9Exer2ProeqdfYYPKAZ53w_34Rmx-KrGTYulisHTb8q_3sA-wFo43V2</recordid><startdate>199305</startdate><enddate>199305</enddate><creator>Lambert, Charles R</creator><creator>Leone, James E</creator><creator>Rowland, Stephen M</creator><general>Lippincott-Raven Publishers</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>199305</creationdate><title>Local drug delivery catheters: functional comparison of porous and microporous designs</title><author>Lambert, Charles R ; Leone, James E ; Rowland, Stephen M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2691-55dd548e7315ae096807664afda0ace91bbf18afaafcb7132a43b8877cefdb093</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1993</creationdate><topic>Animals</topic><topic>Arteries - diagnostic imaging</topic><topic>Arteries - injuries</topic><topic>Catheterization, Peripheral - adverse effects</topic><topic>Catheterization, Peripheral - instrumentation</topic><topic>Dogs</topic><topic>Infusions, Intra-Arterial - adverse effects</topic><topic>Infusions, Intra-Arterial - instrumentation</topic><topic>Models, Cardiovascular</topic><topic>Pharmaceutical Preparations - administration &amp; dosage</topic><topic>Porosity</topic><topic>Ultrasonography</topic><topic>Wounds and Injuries - pathology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lambert, Charles R</creatorcontrib><creatorcontrib>Leone, James E</creatorcontrib><creatorcontrib>Rowland, Stephen M</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><jtitle>Coronary artery disease</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lambert, Charles R</au><au>Leone, James E</au><au>Rowland, Stephen M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Local drug delivery catheters: functional comparison of porous and microporous designs</atitle><jtitle>Coronary artery disease</jtitle><addtitle>Coron Artery Dis</addtitle><date>1993-05</date><risdate>1993</risdate><volume>4</volume><issue>5</issue><spage>469</spage><epage>476</epage><pages>469-476</pages><issn>0954-6928</issn><eissn>1473-5830</eissn><abstract>BACKGROUNDThe porous (Wolinski) balloon was designed to allow local delivery of compounds targeted to inhibit postintervention restenosis; however, successful use of the device has been hampered by arterial trauma caused by the balloon itself. This study utilized several experimental systems to assess the functional characteristics of the porous balloon catheter. This information was utilized to design and test a new microporous infusion catheter for local intra-arterial drug delivery. METHODSFlow characteristics in fluid and semisolid media as well as arterial trauma by light and electron microscopy were documented for the porous and microporous balloons. In addition, the efficacy of methylene blue delivery in situ and in vitro was documented and quantified for the microporous design. RESULTSThe porous balloon exhibits flow characteristics consistent with orifice-related streaming that produces arterial trauma. By maximizing external balloon-pore density and minimizing pore size, the microporous design minimizes streaming in test systems. This is manifested by minimal arterial trauma when applied to intact arteries. The microporous catheter is effective for dye delivery both in situ and in vivo. CONCLUSIONSThe microporous catheter design offers improved functional characteristics when compared with the porous balloon for local intra-arterial drug delivery.</abstract><cop>England</cop><pub>Lippincott-Raven Publishers</pub><pmid>8261224</pmid><doi>10.1097/00019501-199305000-00011</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0954-6928
ispartof Coronary artery disease, 1993-05, Vol.4 (5), p.469-476
issn 0954-6928
1473-5830
language eng
recordid cdi_crossref_primary_10_1097_00019501_199305000_00011
source Journals@Ovid Ovid Autoload; MEDLINE
subjects Animals
Arteries - diagnostic imaging
Arteries - injuries
Catheterization, Peripheral - adverse effects
Catheterization, Peripheral - instrumentation
Dogs
Infusions, Intra-Arterial - adverse effects
Infusions, Intra-Arterial - instrumentation
Models, Cardiovascular
Pharmaceutical Preparations - administration & dosage
Porosity
Ultrasonography
Wounds and Injuries - pathology
title Local drug delivery catheters: functional comparison of porous and microporous designs
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-15T09%3A29%3A38IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Local%20drug%20delivery%20catheters:%20functional%20comparison%20of%20porous%20and%20microporous%20designs&rft.jtitle=Coronary%20artery%20disease&rft.au=Lambert,%20Charles%20R&rft.date=1993-05&rft.volume=4&rft.issue=5&rft.spage=469&rft.epage=476&rft.pages=469-476&rft.issn=0954-6928&rft.eissn=1473-5830&rft_id=info:doi/10.1097/00019501-199305000-00011&rft_dat=%3Cpubmed_cross%3E8261224%3C/pubmed_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/8261224&rfr_iscdi=true