A Two Layer Model for the Effects of Blood Contact on Membrane Transport in Artificial Organs

The performance of many artificial organs can be strongly affected by the transport characteristics of the semi-permeable membranes used in these devices, but there is little data on the effects of blood contact on membrane transport properties. Experimental data were obtained for the solute flux th...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:ASAIO journal (1992) 1994-07, Vol.40 (3), p.M864-M869
Hauptverfasser: Boyd, Russell F, Langsdorf, Leah J, Zydney, Andrew L
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page M869
container_issue 3
container_start_page M864
container_title ASAIO journal (1992)
container_volume 40
creator Boyd, Russell F
Langsdorf, Leah J
Zydney, Andrew L
description The performance of many artificial organs can be strongly affected by the transport characteristics of the semi-permeable membranes used in these devices, but there is little data on the effects of blood contact on membrane transport properties. Experimental data were obtained for the solute flux through cellulosic, polyacrylonitrile, and polyethersulfone membranes using polydispersed dextrans. Blood contact had a very large effect on diffusive solute transport through the asymmetric polyethersulfone membranes, but only a small effect on diffusion through the symmetric AN69 and Cuprophan membranes. In contrast, blood contact caused a similar reduction in convective solute transport (sieving) through both the polyethersulfone and AN69 membranes. Convective transport through the blood contacted membranes was also dependent on the flow direction, with greater transport obtained when the membrane was oriented with the blood contacted surface downstream. These data were analyzed using a two layer membrane model consisting of an upper layer of blood cells and proteins adsorbed to the surface of the native membrane. This model accurately accounted for the different effects of blood contact on convection and diffusion, as well as the observed asymmetry in convective solute transport. These results have important implications for the analysis of solute transport in artificial organs.
doi_str_mv 10.1097/00002480-199407000-00120
format Article
fullrecord <record><control><sourceid>pubmed_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1097_00002480_199407000_00120</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>8555636</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3490-cd049ae752182782c18deb2637379c41e63362b510b682d2319314746a01e1693</originalsourceid><addsrcrecordid>eNp1kUtLAzEUhYMoPqo_QcjC7Whu3lnW4gta3FRwI0Mmk7Gj00lJRkr_vdHW7ryL3BvOORfyBSEM5BqIUTckF-WaFGAMJyrfCkKAkgN0CoLpwnD2ephnInRBDcgTdJbSR7YIxuAYHWshhGTyFL2N8Xwd8NRufMSzUPsONyHiYeHxXdN4NyQcGnzbhVDjSegH6wYcejzzyyra3uN5PtMqxAG3PR7HoW1a19oOP8f3LJyjo8Z2yV_s-gi93N_NJ4_F9PnhaTKeFo5xQwpXE26sV4KCpkpTB7r2FZVMMWUcBy8Zk7QSQCqpaU0ZGAZccWkJeJCGjZDe7nUxpBR9U65iu7RxUwIpf4CVf8DKPbDyF1iOXm6jq69q6et9cEco61c73SZnuya_17Vpb2NCMVA82_jWtg7d4GP67L7WPpYLb7thUf73Xewbq8F_rw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>A Two Layer Model for the Effects of Blood Contact on Membrane Transport in Artificial Organs</title><source>MEDLINE</source><source>Journals@Ovid LWW Legacy Archive</source><source>Journals@Ovid Complete</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Boyd, Russell F ; Langsdorf, Leah J ; Zydney, Andrew L</creator><creatorcontrib>Boyd, Russell F ; Langsdorf, Leah J ; Zydney, Andrew L</creatorcontrib><description>The performance of many artificial organs can be strongly affected by the transport characteristics of the semi-permeable membranes used in these devices, but there is little data on the effects of blood contact on membrane transport properties. Experimental data were obtained for the solute flux through cellulosic, polyacrylonitrile, and polyethersulfone membranes using polydispersed dextrans. Blood contact had a very large effect on diffusive solute transport through the asymmetric polyethersulfone membranes, but only a small effect on diffusion through the symmetric AN69 and Cuprophan membranes. In contrast, blood contact caused a similar reduction in convective solute transport (sieving) through both the polyethersulfone and AN69 membranes. Convective transport through the blood contacted membranes was also dependent on the flow direction, with greater transport obtained when the membrane was oriented with the blood contacted surface downstream. These data were analyzed using a two layer membrane model consisting of an upper layer of blood cells and proteins adsorbed to the surface of the native membrane. This model accurately accounted for the different effects of blood contact on convection and diffusion, as well as the observed asymmetry in convective solute transport. These results have important implications for the analysis of solute transport in artificial organs.</description><identifier>ISSN: 1058-2916</identifier><identifier>EISSN: 1538-943X</identifier><identifier>DOI: 10.1097/00002480-199407000-00120</identifier><identifier>PMID: 8555636</identifier><identifier>CODEN: AJOUET</identifier><language>eng</language><publisher>Philadelphia, PA: Amercian Society of Artificial Internal Organs</publisher><subject>Acrylic Resins ; Acrylonitrile - analogs &amp; derivatives ; Artificial Organs ; Biocompatible Materials ; Biological and medical sciences ; Blood ; Cellulose - analogs &amp; derivatives ; Dextrans - pharmacokinetics ; Diffusion ; Humans ; In Vitro Techniques ; Materials Testing ; Medical sciences ; Membranes, Artificial ; Models, Biological ; Polymers ; Sulfones ; Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases ; Technology. Biomaterials. Equipments</subject><ispartof>ASAIO journal (1992), 1994-07, Vol.40 (3), p.M864-M869</ispartof><rights>1994Amercian Society of Artificial Internal Organs</rights><rights>1995 INIST-CNRS</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3490-cd049ae752182782c18deb2637379c41e63362b510b682d2319314746a01e1693</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf><![CDATA[$$Uhttp://ovidsp.ovid.com/ovidweb.cgi?T=JS&CSC=Y&NEWS=N&PAGE=fulltext&PDF=y&D=ovft&AN=00002480-199407000-00120$$EPDF$$P50$$Gwolterskluwer$$H]]></linktopdf><linktohtml>$$Uhttp://ovidsp.ovid.com/ovidweb.cgi?T=JS&amp;NEWS=n&amp;CSC=Y&amp;PAGE=fulltext&amp;D=ovft&amp;AN=00002480-199407000-00120$$EHTML$$P50$$Gwolterskluwer$$H</linktohtml><link.rule.ids>314,780,784,4609,27924,27925,64666,65461</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=3573174$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/8555636$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Boyd, Russell F</creatorcontrib><creatorcontrib>Langsdorf, Leah J</creatorcontrib><creatorcontrib>Zydney, Andrew L</creatorcontrib><title>A Two Layer Model for the Effects of Blood Contact on Membrane Transport in Artificial Organs</title><title>ASAIO journal (1992)</title><addtitle>ASAIO J</addtitle><description>The performance of many artificial organs can be strongly affected by the transport characteristics of the semi-permeable membranes used in these devices, but there is little data on the effects of blood contact on membrane transport properties. Experimental data were obtained for the solute flux through cellulosic, polyacrylonitrile, and polyethersulfone membranes using polydispersed dextrans. Blood contact had a very large effect on diffusive solute transport through the asymmetric polyethersulfone membranes, but only a small effect on diffusion through the symmetric AN69 and Cuprophan membranes. In contrast, blood contact caused a similar reduction in convective solute transport (sieving) through both the polyethersulfone and AN69 membranes. Convective transport through the blood contacted membranes was also dependent on the flow direction, with greater transport obtained when the membrane was oriented with the blood contacted surface downstream. These data were analyzed using a two layer membrane model consisting of an upper layer of blood cells and proteins adsorbed to the surface of the native membrane. This model accurately accounted for the different effects of blood contact on convection and diffusion, as well as the observed asymmetry in convective solute transport. These results have important implications for the analysis of solute transport in artificial organs.</description><subject>Acrylic Resins</subject><subject>Acrylonitrile - analogs &amp; derivatives</subject><subject>Artificial Organs</subject><subject>Biocompatible Materials</subject><subject>Biological and medical sciences</subject><subject>Blood</subject><subject>Cellulose - analogs &amp; derivatives</subject><subject>Dextrans - pharmacokinetics</subject><subject>Diffusion</subject><subject>Humans</subject><subject>In Vitro Techniques</subject><subject>Materials Testing</subject><subject>Medical sciences</subject><subject>Membranes, Artificial</subject><subject>Models, Biological</subject><subject>Polymers</subject><subject>Sulfones</subject><subject>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</subject><subject>Technology. Biomaterials. Equipments</subject><issn>1058-2916</issn><issn>1538-943X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1994</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kUtLAzEUhYMoPqo_QcjC7Whu3lnW4gta3FRwI0Mmk7Gj00lJRkr_vdHW7ryL3BvOORfyBSEM5BqIUTckF-WaFGAMJyrfCkKAkgN0CoLpwnD2ephnInRBDcgTdJbSR7YIxuAYHWshhGTyFL2N8Xwd8NRufMSzUPsONyHiYeHxXdN4NyQcGnzbhVDjSegH6wYcejzzyyra3uN5PtMqxAG3PR7HoW1a19oOP8f3LJyjo8Z2yV_s-gi93N_NJ4_F9PnhaTKeFo5xQwpXE26sV4KCpkpTB7r2FZVMMWUcBy8Zk7QSQCqpaU0ZGAZccWkJeJCGjZDe7nUxpBR9U65iu7RxUwIpf4CVf8DKPbDyF1iOXm6jq69q6et9cEco61c73SZnuya_17Vpb2NCMVA82_jWtg7d4GP67L7WPpYLb7thUf73Xewbq8F_rw</recordid><startdate>199407</startdate><enddate>199407</enddate><creator>Boyd, Russell F</creator><creator>Langsdorf, Leah J</creator><creator>Zydney, Andrew L</creator><general>Amercian Society of Artificial Internal Organs</general><general>Lippincott</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>199407</creationdate><title>A Two Layer Model for the Effects of Blood Contact on Membrane Transport in Artificial Organs</title><author>Boyd, Russell F ; Langsdorf, Leah J ; Zydney, Andrew L</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3490-cd049ae752182782c18deb2637379c41e63362b510b682d2319314746a01e1693</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1994</creationdate><topic>Acrylic Resins</topic><topic>Acrylonitrile - analogs &amp; derivatives</topic><topic>Artificial Organs</topic><topic>Biocompatible Materials</topic><topic>Biological and medical sciences</topic><topic>Blood</topic><topic>Cellulose - analogs &amp; derivatives</topic><topic>Dextrans - pharmacokinetics</topic><topic>Diffusion</topic><topic>Humans</topic><topic>In Vitro Techniques</topic><topic>Materials Testing</topic><topic>Medical sciences</topic><topic>Membranes, Artificial</topic><topic>Models, Biological</topic><topic>Polymers</topic><topic>Sulfones</topic><topic>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</topic><topic>Technology. Biomaterials. Equipments</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Boyd, Russell F</creatorcontrib><creatorcontrib>Langsdorf, Leah J</creatorcontrib><creatorcontrib>Zydney, Andrew L</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><jtitle>ASAIO journal (1992)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Boyd, Russell F</au><au>Langsdorf, Leah J</au><au>Zydney, Andrew L</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Two Layer Model for the Effects of Blood Contact on Membrane Transport in Artificial Organs</atitle><jtitle>ASAIO journal (1992)</jtitle><addtitle>ASAIO J</addtitle><date>1994-07</date><risdate>1994</risdate><volume>40</volume><issue>3</issue><spage>M864</spage><epage>M869</epage><pages>M864-M869</pages><issn>1058-2916</issn><eissn>1538-943X</eissn><coden>AJOUET</coden><abstract>The performance of many artificial organs can be strongly affected by the transport characteristics of the semi-permeable membranes used in these devices, but there is little data on the effects of blood contact on membrane transport properties. Experimental data were obtained for the solute flux through cellulosic, polyacrylonitrile, and polyethersulfone membranes using polydispersed dextrans. Blood contact had a very large effect on diffusive solute transport through the asymmetric polyethersulfone membranes, but only a small effect on diffusion through the symmetric AN69 and Cuprophan membranes. In contrast, blood contact caused a similar reduction in convective solute transport (sieving) through both the polyethersulfone and AN69 membranes. Convective transport through the blood contacted membranes was also dependent on the flow direction, with greater transport obtained when the membrane was oriented with the blood contacted surface downstream. These data were analyzed using a two layer membrane model consisting of an upper layer of blood cells and proteins adsorbed to the surface of the native membrane. This model accurately accounted for the different effects of blood contact on convection and diffusion, as well as the observed asymmetry in convective solute transport. These results have important implications for the analysis of solute transport in artificial organs.</abstract><cop>Philadelphia, PA</cop><cop>Hagerstown, MD</cop><pub>Amercian Society of Artificial Internal Organs</pub><pmid>8555636</pmid><doi>10.1097/00002480-199407000-00120</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1058-2916
ispartof ASAIO journal (1992), 1994-07, Vol.40 (3), p.M864-M869
issn 1058-2916
1538-943X
language eng
recordid cdi_crossref_primary_10_1097_00002480_199407000_00120
source MEDLINE; Journals@Ovid LWW Legacy Archive; Journals@Ovid Complete; EZB-FREE-00999 freely available EZB journals
subjects Acrylic Resins
Acrylonitrile - analogs & derivatives
Artificial Organs
Biocompatible Materials
Biological and medical sciences
Blood
Cellulose - analogs & derivatives
Dextrans - pharmacokinetics
Diffusion
Humans
In Vitro Techniques
Materials Testing
Medical sciences
Membranes, Artificial
Models, Biological
Polymers
Sulfones
Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases
Technology. Biomaterials. Equipments
title A Two Layer Model for the Effects of Blood Contact on Membrane Transport in Artificial Organs
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T03%3A40%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Two%20Layer%20Model%20for%20the%20Effects%20of%20Blood%20Contact%20on%20Membrane%20Transport%20in%20Artificial%20Organs&rft.jtitle=ASAIO%20journal%20(1992)&rft.au=Boyd,%20Russell%20F&rft.date=1994-07&rft.volume=40&rft.issue=3&rft.spage=M864&rft.epage=M869&rft.pages=M864-M869&rft.issn=1058-2916&rft.eissn=1538-943X&rft.coden=AJOUET&rft_id=info:doi/10.1097/00002480-199407000-00120&rft_dat=%3Cpubmed_cross%3E8555636%3C/pubmed_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/8555636&rfr_iscdi=true