A Two Layer Model for the Effects of Blood Contact on Membrane Transport in Artificial Organs
The performance of many artificial organs can be strongly affected by the transport characteristics of the semi-permeable membranes used in these devices, but there is little data on the effects of blood contact on membrane transport properties. Experimental data were obtained for the solute flux th...
Gespeichert in:
Veröffentlicht in: | ASAIO journal (1992) 1994-07, Vol.40 (3), p.M864-M869 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | M869 |
---|---|
container_issue | 3 |
container_start_page | M864 |
container_title | ASAIO journal (1992) |
container_volume | 40 |
creator | Boyd, Russell F Langsdorf, Leah J Zydney, Andrew L |
description | The performance of many artificial organs can be strongly affected by the transport characteristics of the semi-permeable membranes used in these devices, but there is little data on the effects of blood contact on membrane transport properties. Experimental data were obtained for the solute flux through cellulosic, polyacrylonitrile, and polyethersulfone membranes using polydispersed dextrans. Blood contact had a very large effect on diffusive solute transport through the asymmetric polyethersulfone membranes, but only a small effect on diffusion through the symmetric AN69 and Cuprophan membranes. In contrast, blood contact caused a similar reduction in convective solute transport (sieving) through both the polyethersulfone and AN69 membranes. Convective transport through the blood contacted membranes was also dependent on the flow direction, with greater transport obtained when the membrane was oriented with the blood contacted surface downstream. These data were analyzed using a two layer membrane model consisting of an upper layer of blood cells and proteins adsorbed to the surface of the native membrane. This model accurately accounted for the different effects of blood contact on convection and diffusion, as well as the observed asymmetry in convective solute transport. These results have important implications for the analysis of solute transport in artificial organs. |
doi_str_mv | 10.1097/00002480-199407000-00120 |
format | Article |
fullrecord | <record><control><sourceid>pubmed_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1097_00002480_199407000_00120</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>8555636</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3490-cd049ae752182782c18deb2637379c41e63362b510b682d2319314746a01e1693</originalsourceid><addsrcrecordid>eNp1kUtLAzEUhYMoPqo_QcjC7Whu3lnW4gta3FRwI0Mmk7Gj00lJRkr_vdHW7ryL3BvOORfyBSEM5BqIUTckF-WaFGAMJyrfCkKAkgN0CoLpwnD2ephnInRBDcgTdJbSR7YIxuAYHWshhGTyFL2N8Xwd8NRufMSzUPsONyHiYeHxXdN4NyQcGnzbhVDjSegH6wYcejzzyyra3uN5PtMqxAG3PR7HoW1a19oOP8f3LJyjo8Z2yV_s-gi93N_NJ4_F9PnhaTKeFo5xQwpXE26sV4KCpkpTB7r2FZVMMWUcBy8Zk7QSQCqpaU0ZGAZccWkJeJCGjZDe7nUxpBR9U65iu7RxUwIpf4CVf8DKPbDyF1iOXm6jq69q6et9cEco61c73SZnuya_17Vpb2NCMVA82_jWtg7d4GP67L7WPpYLb7thUf73Xewbq8F_rw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>A Two Layer Model for the Effects of Blood Contact on Membrane Transport in Artificial Organs</title><source>MEDLINE</source><source>Journals@Ovid LWW Legacy Archive</source><source>Journals@Ovid Complete</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Boyd, Russell F ; Langsdorf, Leah J ; Zydney, Andrew L</creator><creatorcontrib>Boyd, Russell F ; Langsdorf, Leah J ; Zydney, Andrew L</creatorcontrib><description>The performance of many artificial organs can be strongly affected by the transport characteristics of the semi-permeable membranes used in these devices, but there is little data on the effects of blood contact on membrane transport properties. Experimental data were obtained for the solute flux through cellulosic, polyacrylonitrile, and polyethersulfone membranes using polydispersed dextrans. Blood contact had a very large effect on diffusive solute transport through the asymmetric polyethersulfone membranes, but only a small effect on diffusion through the symmetric AN69 and Cuprophan membranes. In contrast, blood contact caused a similar reduction in convective solute transport (sieving) through both the polyethersulfone and AN69 membranes. Convective transport through the blood contacted membranes was also dependent on the flow direction, with greater transport obtained when the membrane was oriented with the blood contacted surface downstream. These data were analyzed using a two layer membrane model consisting of an upper layer of blood cells and proteins adsorbed to the surface of the native membrane. This model accurately accounted for the different effects of blood contact on convection and diffusion, as well as the observed asymmetry in convective solute transport. These results have important implications for the analysis of solute transport in artificial organs.</description><identifier>ISSN: 1058-2916</identifier><identifier>EISSN: 1538-943X</identifier><identifier>DOI: 10.1097/00002480-199407000-00120</identifier><identifier>PMID: 8555636</identifier><identifier>CODEN: AJOUET</identifier><language>eng</language><publisher>Philadelphia, PA: Amercian Society of Artificial Internal Organs</publisher><subject>Acrylic Resins ; Acrylonitrile - analogs & derivatives ; Artificial Organs ; Biocompatible Materials ; Biological and medical sciences ; Blood ; Cellulose - analogs & derivatives ; Dextrans - pharmacokinetics ; Diffusion ; Humans ; In Vitro Techniques ; Materials Testing ; Medical sciences ; Membranes, Artificial ; Models, Biological ; Polymers ; Sulfones ; Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases ; Technology. Biomaterials. Equipments</subject><ispartof>ASAIO journal (1992), 1994-07, Vol.40 (3), p.M864-M869</ispartof><rights>1994Amercian Society of Artificial Internal Organs</rights><rights>1995 INIST-CNRS</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3490-cd049ae752182782c18deb2637379c41e63362b510b682d2319314746a01e1693</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf><![CDATA[$$Uhttp://ovidsp.ovid.com/ovidweb.cgi?T=JS&CSC=Y&NEWS=N&PAGE=fulltext&PDF=y&D=ovft&AN=00002480-199407000-00120$$EPDF$$P50$$Gwolterskluwer$$H]]></linktopdf><linktohtml>$$Uhttp://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=fulltext&D=ovft&AN=00002480-199407000-00120$$EHTML$$P50$$Gwolterskluwer$$H</linktohtml><link.rule.ids>314,780,784,4609,27924,27925,64666,65461</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=3573174$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/8555636$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Boyd, Russell F</creatorcontrib><creatorcontrib>Langsdorf, Leah J</creatorcontrib><creatorcontrib>Zydney, Andrew L</creatorcontrib><title>A Two Layer Model for the Effects of Blood Contact on Membrane Transport in Artificial Organs</title><title>ASAIO journal (1992)</title><addtitle>ASAIO J</addtitle><description>The performance of many artificial organs can be strongly affected by the transport characteristics of the semi-permeable membranes used in these devices, but there is little data on the effects of blood contact on membrane transport properties. Experimental data were obtained for the solute flux through cellulosic, polyacrylonitrile, and polyethersulfone membranes using polydispersed dextrans. Blood contact had a very large effect on diffusive solute transport through the asymmetric polyethersulfone membranes, but only a small effect on diffusion through the symmetric AN69 and Cuprophan membranes. In contrast, blood contact caused a similar reduction in convective solute transport (sieving) through both the polyethersulfone and AN69 membranes. Convective transport through the blood contacted membranes was also dependent on the flow direction, with greater transport obtained when the membrane was oriented with the blood contacted surface downstream. These data were analyzed using a two layer membrane model consisting of an upper layer of blood cells and proteins adsorbed to the surface of the native membrane. This model accurately accounted for the different effects of blood contact on convection and diffusion, as well as the observed asymmetry in convective solute transport. These results have important implications for the analysis of solute transport in artificial organs.</description><subject>Acrylic Resins</subject><subject>Acrylonitrile - analogs & derivatives</subject><subject>Artificial Organs</subject><subject>Biocompatible Materials</subject><subject>Biological and medical sciences</subject><subject>Blood</subject><subject>Cellulose - analogs & derivatives</subject><subject>Dextrans - pharmacokinetics</subject><subject>Diffusion</subject><subject>Humans</subject><subject>In Vitro Techniques</subject><subject>Materials Testing</subject><subject>Medical sciences</subject><subject>Membranes, Artificial</subject><subject>Models, Biological</subject><subject>Polymers</subject><subject>Sulfones</subject><subject>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</subject><subject>Technology. Biomaterials. Equipments</subject><issn>1058-2916</issn><issn>1538-943X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1994</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kUtLAzEUhYMoPqo_QcjC7Whu3lnW4gta3FRwI0Mmk7Gj00lJRkr_vdHW7ryL3BvOORfyBSEM5BqIUTckF-WaFGAMJyrfCkKAkgN0CoLpwnD2ephnInRBDcgTdJbSR7YIxuAYHWshhGTyFL2N8Xwd8NRufMSzUPsONyHiYeHxXdN4NyQcGnzbhVDjSegH6wYcejzzyyra3uN5PtMqxAG3PR7HoW1a19oOP8f3LJyjo8Z2yV_s-gi93N_NJ4_F9PnhaTKeFo5xQwpXE26sV4KCpkpTB7r2FZVMMWUcBy8Zk7QSQCqpaU0ZGAZccWkJeJCGjZDe7nUxpBR9U65iu7RxUwIpf4CVf8DKPbDyF1iOXm6jq69q6et9cEco61c73SZnuya_17Vpb2NCMVA82_jWtg7d4GP67L7WPpYLb7thUf73Xewbq8F_rw</recordid><startdate>199407</startdate><enddate>199407</enddate><creator>Boyd, Russell F</creator><creator>Langsdorf, Leah J</creator><creator>Zydney, Andrew L</creator><general>Amercian Society of Artificial Internal Organs</general><general>Lippincott</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>199407</creationdate><title>A Two Layer Model for the Effects of Blood Contact on Membrane Transport in Artificial Organs</title><author>Boyd, Russell F ; Langsdorf, Leah J ; Zydney, Andrew L</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3490-cd049ae752182782c18deb2637379c41e63362b510b682d2319314746a01e1693</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1994</creationdate><topic>Acrylic Resins</topic><topic>Acrylonitrile - analogs & derivatives</topic><topic>Artificial Organs</topic><topic>Biocompatible Materials</topic><topic>Biological and medical sciences</topic><topic>Blood</topic><topic>Cellulose - analogs & derivatives</topic><topic>Dextrans - pharmacokinetics</topic><topic>Diffusion</topic><topic>Humans</topic><topic>In Vitro Techniques</topic><topic>Materials Testing</topic><topic>Medical sciences</topic><topic>Membranes, Artificial</topic><topic>Models, Biological</topic><topic>Polymers</topic><topic>Sulfones</topic><topic>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</topic><topic>Technology. Biomaterials. Equipments</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Boyd, Russell F</creatorcontrib><creatorcontrib>Langsdorf, Leah J</creatorcontrib><creatorcontrib>Zydney, Andrew L</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><jtitle>ASAIO journal (1992)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Boyd, Russell F</au><au>Langsdorf, Leah J</au><au>Zydney, Andrew L</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Two Layer Model for the Effects of Blood Contact on Membrane Transport in Artificial Organs</atitle><jtitle>ASAIO journal (1992)</jtitle><addtitle>ASAIO J</addtitle><date>1994-07</date><risdate>1994</risdate><volume>40</volume><issue>3</issue><spage>M864</spage><epage>M869</epage><pages>M864-M869</pages><issn>1058-2916</issn><eissn>1538-943X</eissn><coden>AJOUET</coden><abstract>The performance of many artificial organs can be strongly affected by the transport characteristics of the semi-permeable membranes used in these devices, but there is little data on the effects of blood contact on membrane transport properties. Experimental data were obtained for the solute flux through cellulosic, polyacrylonitrile, and polyethersulfone membranes using polydispersed dextrans. Blood contact had a very large effect on diffusive solute transport through the asymmetric polyethersulfone membranes, but only a small effect on diffusion through the symmetric AN69 and Cuprophan membranes. In contrast, blood contact caused a similar reduction in convective solute transport (sieving) through both the polyethersulfone and AN69 membranes. Convective transport through the blood contacted membranes was also dependent on the flow direction, with greater transport obtained when the membrane was oriented with the blood contacted surface downstream. These data were analyzed using a two layer membrane model consisting of an upper layer of blood cells and proteins adsorbed to the surface of the native membrane. This model accurately accounted for the different effects of blood contact on convection and diffusion, as well as the observed asymmetry in convective solute transport. These results have important implications for the analysis of solute transport in artificial organs.</abstract><cop>Philadelphia, PA</cop><cop>Hagerstown, MD</cop><pub>Amercian Society of Artificial Internal Organs</pub><pmid>8555636</pmid><doi>10.1097/00002480-199407000-00120</doi><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1058-2916 |
ispartof | ASAIO journal (1992), 1994-07, Vol.40 (3), p.M864-M869 |
issn | 1058-2916 1538-943X |
language | eng |
recordid | cdi_crossref_primary_10_1097_00002480_199407000_00120 |
source | MEDLINE; Journals@Ovid LWW Legacy Archive; Journals@Ovid Complete; EZB-FREE-00999 freely available EZB journals |
subjects | Acrylic Resins Acrylonitrile - analogs & derivatives Artificial Organs Biocompatible Materials Biological and medical sciences Blood Cellulose - analogs & derivatives Dextrans - pharmacokinetics Diffusion Humans In Vitro Techniques Materials Testing Medical sciences Membranes, Artificial Models, Biological Polymers Sulfones Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases Technology. Biomaterials. Equipments |
title | A Two Layer Model for the Effects of Blood Contact on Membrane Transport in Artificial Organs |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T03%3A40%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Two%20Layer%20Model%20for%20the%20Effects%20of%20Blood%20Contact%20on%20Membrane%20Transport%20in%20Artificial%20Organs&rft.jtitle=ASAIO%20journal%20(1992)&rft.au=Boyd,%20Russell%20F&rft.date=1994-07&rft.volume=40&rft.issue=3&rft.spage=M864&rft.epage=M869&rft.pages=M864-M869&rft.issn=1058-2916&rft.eissn=1538-943X&rft.coden=AJOUET&rft_id=info:doi/10.1097/00002480-199407000-00120&rft_dat=%3Cpubmed_cross%3E8555636%3C/pubmed_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/8555636&rfr_iscdi=true |