P1675Evolution of lactate dehydrogenase levels in patients with HeartMate II, HeartWare and HeartMate 3 left ventricular assist devices during first-year follow-up
Abstract Background Lactate dehydrogenase (LDH) is considered as a biomarker of thrombotic events in patients receiving a left ventricular assist device (LVAD). Purpose This study aimed to investigate the evolution of LDH levels over time between patients supported with a HeartMate II (HMII), HeartM...
Gespeichert in:
Veröffentlicht in: | European heart journal 2019-10, Vol.40 (Supplement_1) |
---|---|
Hauptverfasser: | , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Abstract
Background
Lactate dehydrogenase (LDH) is considered as a biomarker of thrombotic events in patients receiving a left ventricular assist device (LVAD).
Purpose
This study aimed to investigate the evolution of LDH levels over time between patients supported with a HeartMate II (HMII), HeartMate 3 (HM3) or HeartWare (HVAD) LVAD during their first-year post implantation.
Methods
We analyzed in this multi-center retrospective study, all patients with HMII, HM3 and HVAD LVAD implanted between December 2006 and April 2017. Patients were classified into three groups based on their device type. Loess splines over time were used to depict the repeated measurements of LDH.
Results
In total, 134 patients received an LVAD (77% male, mean age 55 [46–61]), of whom 64 (48%) were HMII, 22 (16%) HM3 and 48 (36%) were HVAD. Loess splines over time indicate that there could be a considerable difference between evolution of LDH (Figure). During the first-year follow-up, 3 (5%) patients had a confirmed and 10 (16%) patients had a suspected pump thrombosis in the HMII group. For the HVAD, there were 6 (13%) patients with confirmed thrombosis and 1 (2%) case of suspected thrombosis, whereas none of the patients in the HM3 group experienced a suspected or confirmed pump thrombosis (p=0.01). The 1-year overall survival rate for HM II, HM3 and HVAD was 84%, 86% and 72% respectively (p=0.311). The overall stroke-free rate at one year was: 89%, 77% and 91% for HMII, HVAD and HM3 respectively (p=0.15).
Means of observed LDH values over time
Conclusion
During the first-year post LVAD implantation, there appear to be different evolutions of LDH levels over time in HMII device patients compared to HVAD or HM3 device patients. Given differences in baseline hemolysis levels between devices, currently used LDH thresholds for detection of impending pump thrombosis may be less sensitive and thus thresholds may be device specific. |
---|---|
ISSN: | 0195-668X 1522-9645 |
DOI: | 10.1093/eurheartj/ehz748.0431 |