P5700Comparison of efficacy and safety of ventricular lesions formation by unipolar and bipolar radiofrequency ablation on an animal model

Abstract Aims Despite all this technical progress, VT recurrence after unipolar ablation remains relatively high (12–47%). Bipolar ablation has been proposed as an appealing solution, which may overcome boundaries associated with unipolar ablation settings. Therefore, we have proposed an animal stud...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European heart journal 2019-10, Vol.40 (Supplement_1)
Hauptverfasser: Soucek, F, Caluori, C, Lehar, F, Jez, J, Pesl, M, Wolf, J, Wojtaszczyk, A, Belaskova, S, Starek, Z
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue Supplement_1
container_start_page
container_title European heart journal
container_volume 40
creator Soucek, F
Caluori, C
Lehar, F
Jez, J
Pesl, M
Wolf, J
Wojtaszczyk, A
Belaskova, S
Starek, Z
description Abstract Aims Despite all this technical progress, VT recurrence after unipolar ablation remains relatively high (12–47%). Bipolar ablation has been proposed as an appealing solution, which may overcome boundaries associated with unipolar ablation settings. Therefore, we have proposed an animal study to compare bipolar (BPA) vs sequential unipolar ablation (UPA) using a contact-force sensing technology on both catheters. Methods 20 large white female pigs (6 months-old, 60–70kg) underwent multiple RF ablations (30W, 60s, 30ml/min irrigation) on ventricular myocardium, from epicardial and endocardial sides. After the procedure, the animal underwent euthanasia, cardioplegia and organ excision. The hearts were fixed and underwent high-resolution cardiac MRI. Each lesion was characterized primarily in terms of volume, depth, width and transmurality. Results We evaluated 35 lesions across the intraventricular septum. No difference in volume, linear dimensions and impedance drop was observed in this area, between the two ablation settings. However, for the generation of unipolar lesions, twice the ablation time was needed. Transmurality of the lesions shows a trend in favor of BPA. We then analyzed 73 lesions from the endocardial side and 34 from the epicardial one of the ventricular free walls. Lesion transmurality was found remarkably improved in BPA (p=0.030, OR 23.73 [4.71,11.96]). Ventricular BPA lesions were significantly deeper on the epicardial side (p
doi_str_mv 10.1093/eurheartj/ehz746.0642
format Article
fullrecord <record><control><sourceid>oup_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1093_eurheartj_ehz746_0642</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><oup_id>10.1093/eurheartj/ehz746.0642</oup_id><sourcerecordid>10.1093/eurheartj/ehz746.0642</sourcerecordid><originalsourceid>FETCH-LOGICAL-c872-7db21e42848d2fbf81c70eb5a2cf2b56e5a50f82d7e5dca84f4ad4554d9e305e3</originalsourceid><addsrcrecordid>eNqNkN1KxDAQhYMouK4-gpAX6G6SJml6KYt_sKAXe-FdSZMJ26VtatIK9RF8alu6eC0MzGFmvsNwELqnZENJnm5hCEfQoT9t4fidcbkhkrMLtKKCsSSXXFyiFaG5SKRUH9foJsYTIURJKlfo511khOx80-lQRd9i7zA4VxltRqxbi6N20I_z-AvaPlRmqHXANcTKtxE7HxrdTxKXIx7aqvPzdubKsw7aVt4F-BygnS3LermfSs9VNbrGjbdQ36Irp-sId-e-Roenx8PuJdm_Pb_uHvaJURlLMlsyCpwprixzpVPUZARKoZlxrBQShBbEKWYzENZoxR3XlgvBbQ4pEZCukVhsTfAxBnBFF6YnwlhQUsx5Fn95FkuexZznxJGF80P3T-QXJwSBrA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>P5700Comparison of efficacy and safety of ventricular lesions formation by unipolar and bipolar radiofrequency ablation on an animal model</title><source>Oxford University Press Journals All Titles (1996-Current)</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Alma/SFX Local Collection</source><creator>Soucek, F ; Caluori, C ; Lehar, F ; Jez, J ; Pesl, M ; Wolf, J ; Wojtaszczyk, A ; Belaskova, S ; Starek, Z</creator><creatorcontrib>Soucek, F ; Caluori, C ; Lehar, F ; Jez, J ; Pesl, M ; Wolf, J ; Wojtaszczyk, A ; Belaskova, S ; Starek, Z</creatorcontrib><description>Abstract Aims Despite all this technical progress, VT recurrence after unipolar ablation remains relatively high (12–47%). Bipolar ablation has been proposed as an appealing solution, which may overcome boundaries associated with unipolar ablation settings. Therefore, we have proposed an animal study to compare bipolar (BPA) vs sequential unipolar ablation (UPA) using a contact-force sensing technology on both catheters. Methods 20 large white female pigs (6 months-old, 60–70kg) underwent multiple RF ablations (30W, 60s, 30ml/min irrigation) on ventricular myocardium, from epicardial and endocardial sides. After the procedure, the animal underwent euthanasia, cardioplegia and organ excision. The hearts were fixed and underwent high-resolution cardiac MRI. Each lesion was characterized primarily in terms of volume, depth, width and transmurality. Results We evaluated 35 lesions across the intraventricular septum. No difference in volume, linear dimensions and impedance drop was observed in this area, between the two ablation settings. However, for the generation of unipolar lesions, twice the ablation time was needed. Transmurality of the lesions shows a trend in favor of BPA. We then analyzed 73 lesions from the endocardial side and 34 from the epicardial one of the ventricular free walls. Lesion transmurality was found remarkably improved in BPA (p=0.030, OR 23.73 [4.71,11.96]). Ventricular BPA lesions were significantly deeper on the epicardial side (p&lt;0.0001) Conclusion BPA is more likely to create transmural lesions in the ventricle, when compared to UPA. Half the time is needed for the creation of comparably deep and large lesions. BPA is specifically more effective in creating epicardial lesions.</description><identifier>ISSN: 0195-668X</identifier><identifier>EISSN: 1522-9645</identifier><identifier>DOI: 10.1093/eurheartj/ehz746.0642</identifier><language>eng</language><publisher>Oxford University Press</publisher><ispartof>European heart journal, 2019-10, Vol.40 (Supplement_1)</ispartof><rights>Published on behalf of the European Society of Cardiology. All rights reserved. © The Author(s) 2019. For permissions, please email: journals.permissions@oup.com. 2019</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,1578,27901,27902</link.rule.ids></links><search><creatorcontrib>Soucek, F</creatorcontrib><creatorcontrib>Caluori, C</creatorcontrib><creatorcontrib>Lehar, F</creatorcontrib><creatorcontrib>Jez, J</creatorcontrib><creatorcontrib>Pesl, M</creatorcontrib><creatorcontrib>Wolf, J</creatorcontrib><creatorcontrib>Wojtaszczyk, A</creatorcontrib><creatorcontrib>Belaskova, S</creatorcontrib><creatorcontrib>Starek, Z</creatorcontrib><title>P5700Comparison of efficacy and safety of ventricular lesions formation by unipolar and bipolar radiofrequency ablation on an animal model</title><title>European heart journal</title><description>Abstract Aims Despite all this technical progress, VT recurrence after unipolar ablation remains relatively high (12–47%). Bipolar ablation has been proposed as an appealing solution, which may overcome boundaries associated with unipolar ablation settings. Therefore, we have proposed an animal study to compare bipolar (BPA) vs sequential unipolar ablation (UPA) using a contact-force sensing technology on both catheters. Methods 20 large white female pigs (6 months-old, 60–70kg) underwent multiple RF ablations (30W, 60s, 30ml/min irrigation) on ventricular myocardium, from epicardial and endocardial sides. After the procedure, the animal underwent euthanasia, cardioplegia and organ excision. The hearts were fixed and underwent high-resolution cardiac MRI. Each lesion was characterized primarily in terms of volume, depth, width and transmurality. Results We evaluated 35 lesions across the intraventricular septum. No difference in volume, linear dimensions and impedance drop was observed in this area, between the two ablation settings. However, for the generation of unipolar lesions, twice the ablation time was needed. Transmurality of the lesions shows a trend in favor of BPA. We then analyzed 73 lesions from the endocardial side and 34 from the epicardial one of the ventricular free walls. Lesion transmurality was found remarkably improved in BPA (p=0.030, OR 23.73 [4.71,11.96]). Ventricular BPA lesions were significantly deeper on the epicardial side (p&lt;0.0001) Conclusion BPA is more likely to create transmural lesions in the ventricle, when compared to UPA. Half the time is needed for the creation of comparably deep and large lesions. BPA is specifically more effective in creating epicardial lesions.</description><issn>0195-668X</issn><issn>1522-9645</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNqNkN1KxDAQhYMouK4-gpAX6G6SJml6KYt_sKAXe-FdSZMJ26VtatIK9RF8alu6eC0MzGFmvsNwELqnZENJnm5hCEfQoT9t4fidcbkhkrMLtKKCsSSXXFyiFaG5SKRUH9foJsYTIURJKlfo511khOx80-lQRd9i7zA4VxltRqxbi6N20I_z-AvaPlRmqHXANcTKtxE7HxrdTxKXIx7aqvPzdubKsw7aVt4F-BygnS3LermfSs9VNbrGjbdQ36Irp-sId-e-Roenx8PuJdm_Pb_uHvaJURlLMlsyCpwprixzpVPUZARKoZlxrBQShBbEKWYzENZoxR3XlgvBbQ4pEZCukVhsTfAxBnBFF6YnwlhQUsx5Fn95FkuexZznxJGF80P3T-QXJwSBrA</recordid><startdate>20191001</startdate><enddate>20191001</enddate><creator>Soucek, F</creator><creator>Caluori, C</creator><creator>Lehar, F</creator><creator>Jez, J</creator><creator>Pesl, M</creator><creator>Wolf, J</creator><creator>Wojtaszczyk, A</creator><creator>Belaskova, S</creator><creator>Starek, Z</creator><general>Oxford University Press</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20191001</creationdate><title>P5700Comparison of efficacy and safety of ventricular lesions formation by unipolar and bipolar radiofrequency ablation on an animal model</title><author>Soucek, F ; Caluori, C ; Lehar, F ; Jez, J ; Pesl, M ; Wolf, J ; Wojtaszczyk, A ; Belaskova, S ; Starek, Z</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c872-7db21e42848d2fbf81c70eb5a2cf2b56e5a50f82d7e5dca84f4ad4554d9e305e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Soucek, F</creatorcontrib><creatorcontrib>Caluori, C</creatorcontrib><creatorcontrib>Lehar, F</creatorcontrib><creatorcontrib>Jez, J</creatorcontrib><creatorcontrib>Pesl, M</creatorcontrib><creatorcontrib>Wolf, J</creatorcontrib><creatorcontrib>Wojtaszczyk, A</creatorcontrib><creatorcontrib>Belaskova, S</creatorcontrib><creatorcontrib>Starek, Z</creatorcontrib><collection>CrossRef</collection><jtitle>European heart journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Soucek, F</au><au>Caluori, C</au><au>Lehar, F</au><au>Jez, J</au><au>Pesl, M</au><au>Wolf, J</au><au>Wojtaszczyk, A</au><au>Belaskova, S</au><au>Starek, Z</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>P5700Comparison of efficacy and safety of ventricular lesions formation by unipolar and bipolar radiofrequency ablation on an animal model</atitle><jtitle>European heart journal</jtitle><date>2019-10-01</date><risdate>2019</risdate><volume>40</volume><issue>Supplement_1</issue><issn>0195-668X</issn><eissn>1522-9645</eissn><abstract>Abstract Aims Despite all this technical progress, VT recurrence after unipolar ablation remains relatively high (12–47%). Bipolar ablation has been proposed as an appealing solution, which may overcome boundaries associated with unipolar ablation settings. Therefore, we have proposed an animal study to compare bipolar (BPA) vs sequential unipolar ablation (UPA) using a contact-force sensing technology on both catheters. Methods 20 large white female pigs (6 months-old, 60–70kg) underwent multiple RF ablations (30W, 60s, 30ml/min irrigation) on ventricular myocardium, from epicardial and endocardial sides. After the procedure, the animal underwent euthanasia, cardioplegia and organ excision. The hearts were fixed and underwent high-resolution cardiac MRI. Each lesion was characterized primarily in terms of volume, depth, width and transmurality. Results We evaluated 35 lesions across the intraventricular septum. No difference in volume, linear dimensions and impedance drop was observed in this area, between the two ablation settings. However, for the generation of unipolar lesions, twice the ablation time was needed. Transmurality of the lesions shows a trend in favor of BPA. We then analyzed 73 lesions from the endocardial side and 34 from the epicardial one of the ventricular free walls. Lesion transmurality was found remarkably improved in BPA (p=0.030, OR 23.73 [4.71,11.96]). Ventricular BPA lesions were significantly deeper on the epicardial side (p&lt;0.0001) Conclusion BPA is more likely to create transmural lesions in the ventricle, when compared to UPA. Half the time is needed for the creation of comparably deep and large lesions. BPA is specifically more effective in creating epicardial lesions.</abstract><pub>Oxford University Press</pub><doi>10.1093/eurheartj/ehz746.0642</doi></addata></record>
fulltext fulltext
identifier ISSN: 0195-668X
ispartof European heart journal, 2019-10, Vol.40 (Supplement_1)
issn 0195-668X
1522-9645
language eng
recordid cdi_crossref_primary_10_1093_eurheartj_ehz746_0642
source Oxford University Press Journals All Titles (1996-Current); Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Alma/SFX Local Collection
title P5700Comparison of efficacy and safety of ventricular lesions formation by unipolar and bipolar radiofrequency ablation on an animal model
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-09T22%3A30%3A56IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-oup_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=P5700Comparison%20of%20efficacy%20and%20safety%20of%20ventricular%20lesions%20formation%20by%20unipolar%20and%20bipolar%20radiofrequency%20ablation%20on%20an%20animal%20model&rft.jtitle=European%20heart%20journal&rft.au=Soucek,%20F&rft.date=2019-10-01&rft.volume=40&rft.issue=Supplement_1&rft.issn=0195-668X&rft.eissn=1522-9645&rft_id=info:doi/10.1093/eurheartj/ehz746.0642&rft_dat=%3Coup_cross%3E10.1093/eurheartj/ehz746.0642%3C/oup_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_oup_id=10.1093/eurheartj/ehz746.0642&rfr_iscdi=true