P5637A novel bioresorbable magnesium-based stent: initial clinical results and 6-months follow-up by coronary computed tomography angiography scan
Abstract Background Drug-eluting stents (DES) are the gold standard in percutaneous coronary interventions (PCI), but leave a permanent metallic “caging” of the treated vessels limiting further assessment of in-stent lumen patency by coronary computed tomography angiography (CCTA) due to artifacts....
Gespeichert in:
Veröffentlicht in: | European heart journal 2019-10, Vol.40 (Supplement_1) |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Abstract
Background
Drug-eluting stents (DES) are the gold standard in percutaneous coronary interventions (PCI), but leave a permanent metallic “caging” of the treated vessels limiting further assessment of in-stent lumen patency by coronary computed tomography angiography (CCTA) due to artifacts. Absorbable scaffolds were designed to overcome the caging limitation but the first generation made of poly-L-lactic acid demonstrated higher thrombosis rates. A novel bioresorbable magnesium-based (Mg-)stent coated with a biodegradable polymer eluting sirolimus has been developed, with promising results in the BIOSOLVEII-III studies.
Aim
We sought to characterize PCI results by CCTA at 6-mo follow-up of patients treated with at least one Mg-stent in our institution.
Methods
Prospective observational registry started since January 2017 of younger patients with de novo lesions preferably treated with Mg-stents after balloon pre-dilatation. Procedural data and major adverse clinical events (MACE) at hospital discharge and 6-mo follow-up were collected. Reference vessel and in-stent minimal lumen area were measured on a CCTA performed at 6-mo.
Results
34 Mg-stents (mean diameter: 3.2±0.2 mm, length 21.3±4.1 mm) were successfully implanted in 29 patients (mean age 54±6 years with male:female ratio 3:1). Acute coronary syndrome was the presenting diagnosis in 76% (n=22) with STEMI in 31% (n=9). The left anterior descending artery was treated in 62% (n=21). Calcifications on angiography were found in 14 lesions (41%). Intravascular imaging was performed in 3 PCI. With CCTA at 7.1±3.5 months (n=15 up to date, ongoing further follow-up to be presented), proximal and distal stent markers were well visualized while scaffold struts were not discernible. Mean proximal and distal reference lumen area were respectively 8.5±4.2 mm2 and 6.1±2.8 mm2. Mean in-stent minimal lumen area (MLA) was 6.3±2.9 mm2, with no statistical difference with the mean of the proximal and distal references (7.3±3.3 mm2, p=0.155, Wilcoxon rank test) demonstrating minimal instent hyperplasia at 6-mo: significant in-stent restenosis was noted in only one patient who remains so far asymptomatic (MLA 1.1 mm2; reference vessel lumen area 5.5 mm2). CCTA were non interpretable in 2 patients due to artifacts unrelated to the Mg-stents. One death secondary to a complicated cardiac tamponade was reported. No further MACE at 6-mo were noted.
CCTA cross sectional cut
Conclusion
6-mo CCTA of patients treated with |
---|---|
ISSN: | 0195-668X 1522-9645 |
DOI: | 10.1093/eurheartj/ehz746.0580 |