Myocardial fibrosis quantification methods by cardiovascular magnetic resonance imaging with contrast-enhancement in patients with Fabry disease

Abstract Funding Acknowledgements Type of funding sources: Public grant(s) – EU funding. Main funding source(s): National Agency for Academic Exchange (NAWA). Background. Presence and extent of late gadolinium enhancement (LGE) in patients with Fabry disease (FD) is a predictor of adverse cardiac ev...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European heart journal cardiovascular imaging 2021-07, Vol.22 (Supplement_2)
Hauptverfasser: Sokolska, J, Karolyi, M, Bataiosu, D, Gastl, M, Weber, L, Sokolski, M, Gruner, C, Manka, R
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Funding Acknowledgements Type of funding sources: Public grant(s) – EU funding. Main funding source(s): National Agency for Academic Exchange (NAWA). Background. Presence and extent of late gadolinium enhancement (LGE) in patients with Fabry disease (FD) is a predictor of adverse cardiac events. However there is no gold standard method to quantify the amount of myocardial fibrosis in cardiac magnetic resonance imaging (CMR). Purpose. The aim of this study was to establish the most reliable and reproducible technique for quantifying LGE in patients with FD. Methods. 68 patients with FD (40% male, 40 ± 16 years old) treated in our outpatient clinic, who underwent CMR with administration of 0.2 mmol of gadobutrol per kilogram of body weight between December 2012 and March 2019 were enrolled into the study. Presence of LGE was described in 25 patients (37%). Twenty patients underwent CMR with the same LGE sequence (Philips 1.5 Tesla, two-dimensional multi-breath-hold inversion recovery sequence) and were enrolled into further analysis. LGE quantifications were performed using gray-scale thresholds with 2, 3, 4, 5 and 6 standard deviations (SD) above the mean signal intensity for the remote myocardial tissue, full width at half maximum method (FWHM), visual assessment with threshold (VAT) and fully manual method (MM; Philips IntelliSpace Portal 10). LGE quantifications were done twice by the same observer in different time periods and once by another observer. Intraclass correlation coefficient (ICC), Bland- Altman analysis and coefficient of variation (CV) were used to assess intra- and interobserver reliability and reproducibility. Results. The mean quantity of fibrosis mass  (in gram) in all studied patients was: 35.5 ± 18.7 at 2SD, 21.0 ± 12.8 at 3SD, 12.7 ± 8.5 at 4SD, 8.0 ± 5.7 at 5SD, 5.3 ± 4.1 at 6SD, 1.9 ± 1.8 at FWHM, 8.6 ± 7.4 at VAT and 9.1 ± 6.1 at MM. Intra-observer reliability of almost all studied LGE quantification methods was excellent, with a range of ICCs from 0.90 for 6SD to 0.95 for VAT, with one exception for FWHM, which had good intraobserver reliability (ICC 0.84; all P 
ISSN:2047-2404
2047-2412
DOI:10.1093/ehjci/jeab090.022