A setup for fast cooling of liquids in sealed containers

We present a simple layout of a fast cooling system for liquids in sealed containers utilizing the large temperature gradients of cold nitrogen gas. Our system is optimized for about 20 cylindrical containers of 500 cm3, but the setup allows for simple up- and down-scaling as well as the use of arbi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of physics communications 2018-03, Vol.2 (3), p.35026
Hauptverfasser: Grachtrup, D Schulze, Kraken, M, Elten, N van, Süllow, S
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 3
container_start_page 35026
container_title Journal of physics communications
container_volume 2
creator Grachtrup, D Schulze
Kraken, M
Elten, N van
Süllow, S
description We present a simple layout of a fast cooling system for liquids in sealed containers utilizing the large temperature gradients of cold nitrogen gas. Our system is optimized for about 20 cylindrical containers of 500 cm3, but the setup allows for simple up- and down-scaling as well as the use of arbitrary containers. We have characterized the cooling performance of our system experimentally for temperatures of the liquid in the range from room temperature down to the freezing point at −2 ºC. With our system we achieve container cooling times as low as 3 min, a significant reduction if compared to cooling times with common methods in the range of 8 to 40 min. Modeling of the cooling process proves that convection within the liquid is crucial for quick heat transfer. For the cases studied here, the most important factor limiting the cooling rate is the thermal conductivity of the container material.
doi_str_mv 10.1088/2399-6528/aab4a5
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1088_2399_6528_aab4a5</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2545967831</sourcerecordid><originalsourceid>FETCH-LOGICAL-c382t-2985b7dc3e907435ae20d6f27962a86eecb232aa21ad0ff23e3570eb1e648d793</originalsourceid><addsrcrecordid>eNp1kM1LxDAQxYMouKx79xjw4MW66aRJ0-Oy-AULXvQc0iaRlNp0k_bgf29KRT3oaYaZ37w3PIQuc3KbEyG2QKsq4wzEVqm6UOwErb5Hp7_6c7SJsSWEQFlRRtkKiR2OZpwGbH3AVsURN953rn_D3uLOHSenI3Z9glRndFr2o3K9CfECnVnVRbP5qmv0en_3sn_MDs8PT_vdIWuogDGDSrC61A01FSkLypQBorlN_hyU4MY0NVBQCnKlibVADWUlMXVueCF0-nKNrhbdIfjjZOIoWz-FPllKYAWreCloniiyUE3wMQZj5RDcuwofMidyjkjOGcg5A7lElE6ulxPnhx_Ndmi8BEkloYwAl4O2ibz5g_xX-BMYonPR</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2545967831</pqid></control><display><type>article</type><title>A setup for fast cooling of liquids in sealed containers</title><source>DOAJ Directory of Open Access Journals</source><source>Institute of Physics Open Access Journal Titles</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Grachtrup, D Schulze ; Kraken, M ; Elten, N van ; Süllow, S</creator><creatorcontrib>Grachtrup, D Schulze ; Kraken, M ; Elten, N van ; Süllow, S</creatorcontrib><description>We present a simple layout of a fast cooling system for liquids in sealed containers utilizing the large temperature gradients of cold nitrogen gas. Our system is optimized for about 20 cylindrical containers of 500 cm3, but the setup allows for simple up- and down-scaling as well as the use of arbitrary containers. We have characterized the cooling performance of our system experimentally for temperatures of the liquid in the range from room temperature down to the freezing point at −2 ºC. With our system we achieve container cooling times as low as 3 min, a significant reduction if compared to cooling times with common methods in the range of 8 to 40 min. Modeling of the cooling process proves that convection within the liquid is crucial for quick heat transfer. For the cases studied here, the most important factor limiting the cooling rate is the thermal conductivity of the container material.</description><identifier>ISSN: 2399-6528</identifier><identifier>EISSN: 2399-6528</identifier><identifier>DOI: 10.1088/2399-6528/aab4a5</identifier><language>eng</language><publisher>Bristol: IOP Publishing</publisher><subject>beer ; cooling setup ; fast cooling of liquids ; FEM simulation ; sealed containers ; Temperature</subject><ispartof>Journal of physics communications, 2018-03, Vol.2 (3), p.35026</ispartof><rights>2018 The Author(s). Published by IOP Publishing Ltd</rights><rights>2018. This work is published under http://creativecommons.org/licenses/by/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c382t-2985b7dc3e907435ae20d6f27962a86eecb232aa21ad0ff23e3570eb1e648d793</citedby><cites>FETCH-LOGICAL-c382t-2985b7dc3e907435ae20d6f27962a86eecb232aa21ad0ff23e3570eb1e648d793</cites><orcidid>0000-0003-0062-3139</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/2399-6528/aab4a5/pdf$$EPDF$$P50$$Giop$$Hfree_for_read</linktopdf><link.rule.ids>314,780,784,864,27924,27925,38890,53867</link.rule.ids></links><search><creatorcontrib>Grachtrup, D Schulze</creatorcontrib><creatorcontrib>Kraken, M</creatorcontrib><creatorcontrib>Elten, N van</creatorcontrib><creatorcontrib>Süllow, S</creatorcontrib><title>A setup for fast cooling of liquids in sealed containers</title><title>Journal of physics communications</title><addtitle>JPCO</addtitle><addtitle>J. Phys. Commun</addtitle><description>We present a simple layout of a fast cooling system for liquids in sealed containers utilizing the large temperature gradients of cold nitrogen gas. Our system is optimized for about 20 cylindrical containers of 500 cm3, but the setup allows for simple up- and down-scaling as well as the use of arbitrary containers. We have characterized the cooling performance of our system experimentally for temperatures of the liquid in the range from room temperature down to the freezing point at −2 ºC. With our system we achieve container cooling times as low as 3 min, a significant reduction if compared to cooling times with common methods in the range of 8 to 40 min. Modeling of the cooling process proves that convection within the liquid is crucial for quick heat transfer. For the cases studied here, the most important factor limiting the cooling rate is the thermal conductivity of the container material.</description><subject>beer</subject><subject>cooling setup</subject><subject>fast cooling of liquids</subject><subject>FEM simulation</subject><subject>sealed containers</subject><subject>Temperature</subject><issn>2399-6528</issn><issn>2399-6528</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><sourceid>O3W</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GNUQQ</sourceid><recordid>eNp1kM1LxDAQxYMouKx79xjw4MW66aRJ0-Oy-AULXvQc0iaRlNp0k_bgf29KRT3oaYaZ37w3PIQuc3KbEyG2QKsq4wzEVqm6UOwErb5Hp7_6c7SJsSWEQFlRRtkKiR2OZpwGbH3AVsURN953rn_D3uLOHSenI3Z9glRndFr2o3K9CfECnVnVRbP5qmv0en_3sn_MDs8PT_vdIWuogDGDSrC61A01FSkLypQBorlN_hyU4MY0NVBQCnKlibVADWUlMXVueCF0-nKNrhbdIfjjZOIoWz-FPllKYAWreCloniiyUE3wMQZj5RDcuwofMidyjkjOGcg5A7lElE6ulxPnhx_Ndmi8BEkloYwAl4O2ibz5g_xX-BMYonPR</recordid><startdate>20180301</startdate><enddate>20180301</enddate><creator>Grachtrup, D Schulze</creator><creator>Kraken, M</creator><creator>Elten, N van</creator><creator>Süllow, S</creator><general>IOP Publishing</general><scope>O3W</scope><scope>TSCCA</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7XB</scope><scope>88I</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>M2P</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>Q9U</scope><orcidid>https://orcid.org/0000-0003-0062-3139</orcidid></search><sort><creationdate>20180301</creationdate><title>A setup for fast cooling of liquids in sealed containers</title><author>Grachtrup, D Schulze ; Kraken, M ; Elten, N van ; Süllow, S</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c382t-2985b7dc3e907435ae20d6f27962a86eecb232aa21ad0ff23e3570eb1e648d793</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>beer</topic><topic>cooling setup</topic><topic>fast cooling of liquids</topic><topic>FEM simulation</topic><topic>sealed containers</topic><topic>Temperature</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Grachtrup, D Schulze</creatorcontrib><creatorcontrib>Kraken, M</creatorcontrib><creatorcontrib>Elten, N van</creatorcontrib><creatorcontrib>Süllow, S</creatorcontrib><collection>Institute of Physics Open Access Journal Titles</collection><collection>IOPscience (Open Access)</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Science Database (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection</collection><collection>Science Database</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>ProQuest Central Basic</collection><jtitle>Journal of physics communications</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Grachtrup, D Schulze</au><au>Kraken, M</au><au>Elten, N van</au><au>Süllow, S</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A setup for fast cooling of liquids in sealed containers</atitle><jtitle>Journal of physics communications</jtitle><stitle>JPCO</stitle><addtitle>J. Phys. Commun</addtitle><date>2018-03-01</date><risdate>2018</risdate><volume>2</volume><issue>3</issue><spage>35026</spage><pages>35026-</pages><issn>2399-6528</issn><eissn>2399-6528</eissn><abstract>We present a simple layout of a fast cooling system for liquids in sealed containers utilizing the large temperature gradients of cold nitrogen gas. Our system is optimized for about 20 cylindrical containers of 500 cm3, but the setup allows for simple up- and down-scaling as well as the use of arbitrary containers. We have characterized the cooling performance of our system experimentally for temperatures of the liquid in the range from room temperature down to the freezing point at −2 ºC. With our system we achieve container cooling times as low as 3 min, a significant reduction if compared to cooling times with common methods in the range of 8 to 40 min. Modeling of the cooling process proves that convection within the liquid is crucial for quick heat transfer. For the cases studied here, the most important factor limiting the cooling rate is the thermal conductivity of the container material.</abstract><cop>Bristol</cop><pub>IOP Publishing</pub><doi>10.1088/2399-6528/aab4a5</doi><tpages>11</tpages><orcidid>https://orcid.org/0000-0003-0062-3139</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2399-6528
ispartof Journal of physics communications, 2018-03, Vol.2 (3), p.35026
issn 2399-6528
2399-6528
language eng
recordid cdi_crossref_primary_10_1088_2399_6528_aab4a5
source DOAJ Directory of Open Access Journals; Institute of Physics Open Access Journal Titles; EZB-FREE-00999 freely available EZB journals
subjects beer
cooling setup
fast cooling of liquids
FEM simulation
sealed containers
Temperature
title A setup for fast cooling of liquids in sealed containers
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-31T00%3A11%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20setup%20for%20fast%20cooling%20of%20liquids%20in%20sealed%20containers&rft.jtitle=Journal%20of%20physics%20communications&rft.au=Grachtrup,%20D%20Schulze&rft.date=2018-03-01&rft.volume=2&rft.issue=3&rft.spage=35026&rft.pages=35026-&rft.issn=2399-6528&rft.eissn=2399-6528&rft_id=info:doi/10.1088/2399-6528/aab4a5&rft_dat=%3Cproquest_cross%3E2545967831%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2545967831&rft_id=info:pmid/&rfr_iscdi=true