Enhancement of optical penetration depth of LED-based NIRS systems by comparing different beam profiles

Near-Infrared Spectroscopy (NIRS) is a non-invasive brain imaging technique involving the quantification of oxy and deoxy-hemoglobin concentrations resolved from the measurement of Near-Infrared (NIR) light attenuation within the tissue. Previous studies have shown that NIR light is more influenced...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Biomedical physics & engineering express 2019-09, Vol.5 (6), p.65004
Hauptverfasser: Mirbagheri, Mahya, Hakimi, Naser, Ebrahimzadeh, Elias, Pourrezaei, Kambiz, Setarehdan, S Kamaledin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 6
container_start_page 65004
container_title Biomedical physics & engineering express
container_volume 5
creator Mirbagheri, Mahya
Hakimi, Naser
Ebrahimzadeh, Elias
Pourrezaei, Kambiz
Setarehdan, S Kamaledin
description Near-Infrared Spectroscopy (NIRS) is a non-invasive brain imaging technique involving the quantification of oxy and deoxy-hemoglobin concentrations resolved from the measurement of Near-Infrared (NIR) light attenuation within the tissue. Previous studies have shown that NIR light is more influenced by the optical properties of the superficial layers than those of the deeper target layers such as cortex. NIR light produced by the Laser source penetrates deeper regions of the tissue rather than the LED source although Laser needs more expensive instrumentation. In this study, we investigate the effect of Uniform and Gaussian beam profiles on the enhancement of LED light penetration depth. The latter beam profiles were generated and compared using Flat and Aspherical lenses applied to the LED sources. In order to increase the signal to noise ratio, the lenses were also applied to the light detector. For performance analysis, two experiments were carried out by scanning the intra space of a liquid phantom by static and dynamic (pulsating) absorbers. Monte Carlo simulations were also carried out to be compared with the experiment. The results showed that Gaussian beam profile and in particular, Bi-Convex lenses applied to both source and detector leads to a greater light penetration depth in the liquid phantom close to that of a Laser source.
doi_str_mv 10.1088/2057-1976/ab42d9
format Article
fullrecord <record><control><sourceid>iop_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1088_2057_1976_ab42d9</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>bpexab42d9</sourcerecordid><originalsourceid>FETCH-LOGICAL-c312t-4d973e1e4d612f25d3f96db39587b67d43efae2109e668b22f3d13e67d4fbb283</originalsourceid><addsrcrecordid>eNp9kM9LwzAUx4MoOObuHnPzYl1-tGl7lDl1MBT8cQ5J87J1rE1IItj_3pWJeBBP7_G-P3h8ELqk5IaSqpozUpQZrUsxVzpnpj5Bk5_T6a_9HM1i3BFCqGBC1MUEbZb9VvUNdNAn7Cx2PrWN2mMPPaSgUut6bMCn7Siul3eZVhEMflq9vOI4xARdxHrAjeu8Cm2_waa1FsLYpkF12Adn2z3EC3Rm1T7C7HtO0fv98m3xmK2fH1aL23XWcMpSlpu65EAhN4IyywrDbS2M5nVRlVqUJudgFTBKahCi0oxZbiiHUbFas4pPETn2NsHFGMBKH9pOhUFSIkdWcoQhRxjyyOoQuT5GWuflzn2E_vDgf_arP-zaw6cspJBEFITk0hvLvwCI-3kB</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Enhancement of optical penetration depth of LED-based NIRS systems by comparing different beam profiles</title><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><creator>Mirbagheri, Mahya ; Hakimi, Naser ; Ebrahimzadeh, Elias ; Pourrezaei, Kambiz ; Setarehdan, S Kamaledin</creator><creatorcontrib>Mirbagheri, Mahya ; Hakimi, Naser ; Ebrahimzadeh, Elias ; Pourrezaei, Kambiz ; Setarehdan, S Kamaledin</creatorcontrib><description>Near-Infrared Spectroscopy (NIRS) is a non-invasive brain imaging technique involving the quantification of oxy and deoxy-hemoglobin concentrations resolved from the measurement of Near-Infrared (NIR) light attenuation within the tissue. Previous studies have shown that NIR light is more influenced by the optical properties of the superficial layers than those of the deeper target layers such as cortex. NIR light produced by the Laser source penetrates deeper regions of the tissue rather than the LED source although Laser needs more expensive instrumentation. In this study, we investigate the effect of Uniform and Gaussian beam profiles on the enhancement of LED light penetration depth. The latter beam profiles were generated and compared using Flat and Aspherical lenses applied to the LED sources. In order to increase the signal to noise ratio, the lenses were also applied to the light detector. For performance analysis, two experiments were carried out by scanning the intra space of a liquid phantom by static and dynamic (pulsating) absorbers. Monte Carlo simulations were also carried out to be compared with the experiment. The results showed that Gaussian beam profile and in particular, Bi-Convex lenses applied to both source and detector leads to a greater light penetration depth in the liquid phantom close to that of a Laser source.</description><identifier>ISSN: 2057-1976</identifier><identifier>EISSN: 2057-1976</identifier><identifier>DOI: 10.1088/2057-1976/ab42d9</identifier><identifier>CODEN: NJOPFM</identifier><language>eng</language><publisher>IOP Publishing</publisher><subject>biomedical optic ; instrumentation ; monte carlo simulation ; near infrared spectroscopy ; optical sensors</subject><ispartof>Biomedical physics &amp; engineering express, 2019-09, Vol.5 (6), p.65004</ispartof><rights>2019 IOP Publishing Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c312t-4d973e1e4d612f25d3f96db39587b67d43efae2109e668b22f3d13e67d4fbb283</citedby><cites>FETCH-LOGICAL-c312t-4d973e1e4d612f25d3f96db39587b67d43efae2109e668b22f3d13e67d4fbb283</cites><orcidid>0000-0001-5928-8668 ; 0000-0002-8758-9991</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/2057-1976/ab42d9/pdf$$EPDF$$P50$$Giop$$H</linktopdf><link.rule.ids>314,776,780,27901,27902,53821,53868</link.rule.ids></links><search><creatorcontrib>Mirbagheri, Mahya</creatorcontrib><creatorcontrib>Hakimi, Naser</creatorcontrib><creatorcontrib>Ebrahimzadeh, Elias</creatorcontrib><creatorcontrib>Pourrezaei, Kambiz</creatorcontrib><creatorcontrib>Setarehdan, S Kamaledin</creatorcontrib><title>Enhancement of optical penetration depth of LED-based NIRS systems by comparing different beam profiles</title><title>Biomedical physics &amp; engineering express</title><addtitle>BPEX</addtitle><addtitle>Biomed. Phys. Eng. Express</addtitle><description>Near-Infrared Spectroscopy (NIRS) is a non-invasive brain imaging technique involving the quantification of oxy and deoxy-hemoglobin concentrations resolved from the measurement of Near-Infrared (NIR) light attenuation within the tissue. Previous studies have shown that NIR light is more influenced by the optical properties of the superficial layers than those of the deeper target layers such as cortex. NIR light produced by the Laser source penetrates deeper regions of the tissue rather than the LED source although Laser needs more expensive instrumentation. In this study, we investigate the effect of Uniform and Gaussian beam profiles on the enhancement of LED light penetration depth. The latter beam profiles were generated and compared using Flat and Aspherical lenses applied to the LED sources. In order to increase the signal to noise ratio, the lenses were also applied to the light detector. For performance analysis, two experiments were carried out by scanning the intra space of a liquid phantom by static and dynamic (pulsating) absorbers. Monte Carlo simulations were also carried out to be compared with the experiment. The results showed that Gaussian beam profile and in particular, Bi-Convex lenses applied to both source and detector leads to a greater light penetration depth in the liquid phantom close to that of a Laser source.</description><subject>biomedical optic</subject><subject>instrumentation</subject><subject>monte carlo simulation</subject><subject>near infrared spectroscopy</subject><subject>optical sensors</subject><issn>2057-1976</issn><issn>2057-1976</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNp9kM9LwzAUx4MoOObuHnPzYl1-tGl7lDl1MBT8cQ5J87J1rE1IItj_3pWJeBBP7_G-P3h8ELqk5IaSqpozUpQZrUsxVzpnpj5Bk5_T6a_9HM1i3BFCqGBC1MUEbZb9VvUNdNAn7Cx2PrWN2mMPPaSgUut6bMCn7Siul3eZVhEMflq9vOI4xARdxHrAjeu8Cm2_waa1FsLYpkF12Adn2z3EC3Rm1T7C7HtO0fv98m3xmK2fH1aL23XWcMpSlpu65EAhN4IyywrDbS2M5nVRlVqUJudgFTBKahCi0oxZbiiHUbFas4pPETn2NsHFGMBKH9pOhUFSIkdWcoQhRxjyyOoQuT5GWuflzn2E_vDgf_arP-zaw6cspJBEFITk0hvLvwCI-3kB</recordid><startdate>20190923</startdate><enddate>20190923</enddate><creator>Mirbagheri, Mahya</creator><creator>Hakimi, Naser</creator><creator>Ebrahimzadeh, Elias</creator><creator>Pourrezaei, Kambiz</creator><creator>Setarehdan, S Kamaledin</creator><general>IOP Publishing</general><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0001-5928-8668</orcidid><orcidid>https://orcid.org/0000-0002-8758-9991</orcidid></search><sort><creationdate>20190923</creationdate><title>Enhancement of optical penetration depth of LED-based NIRS systems by comparing different beam profiles</title><author>Mirbagheri, Mahya ; Hakimi, Naser ; Ebrahimzadeh, Elias ; Pourrezaei, Kambiz ; Setarehdan, S Kamaledin</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c312t-4d973e1e4d612f25d3f96db39587b67d43efae2109e668b22f3d13e67d4fbb283</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>biomedical optic</topic><topic>instrumentation</topic><topic>monte carlo simulation</topic><topic>near infrared spectroscopy</topic><topic>optical sensors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mirbagheri, Mahya</creatorcontrib><creatorcontrib>Hakimi, Naser</creatorcontrib><creatorcontrib>Ebrahimzadeh, Elias</creatorcontrib><creatorcontrib>Pourrezaei, Kambiz</creatorcontrib><creatorcontrib>Setarehdan, S Kamaledin</creatorcontrib><collection>CrossRef</collection><jtitle>Biomedical physics &amp; engineering express</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mirbagheri, Mahya</au><au>Hakimi, Naser</au><au>Ebrahimzadeh, Elias</au><au>Pourrezaei, Kambiz</au><au>Setarehdan, S Kamaledin</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Enhancement of optical penetration depth of LED-based NIRS systems by comparing different beam profiles</atitle><jtitle>Biomedical physics &amp; engineering express</jtitle><stitle>BPEX</stitle><addtitle>Biomed. Phys. Eng. Express</addtitle><date>2019-09-23</date><risdate>2019</risdate><volume>5</volume><issue>6</issue><spage>65004</spage><pages>65004-</pages><issn>2057-1976</issn><eissn>2057-1976</eissn><coden>NJOPFM</coden><abstract>Near-Infrared Spectroscopy (NIRS) is a non-invasive brain imaging technique involving the quantification of oxy and deoxy-hemoglobin concentrations resolved from the measurement of Near-Infrared (NIR) light attenuation within the tissue. Previous studies have shown that NIR light is more influenced by the optical properties of the superficial layers than those of the deeper target layers such as cortex. NIR light produced by the Laser source penetrates deeper regions of the tissue rather than the LED source although Laser needs more expensive instrumentation. In this study, we investigate the effect of Uniform and Gaussian beam profiles on the enhancement of LED light penetration depth. The latter beam profiles were generated and compared using Flat and Aspherical lenses applied to the LED sources. In order to increase the signal to noise ratio, the lenses were also applied to the light detector. For performance analysis, two experiments were carried out by scanning the intra space of a liquid phantom by static and dynamic (pulsating) absorbers. Monte Carlo simulations were also carried out to be compared with the experiment. The results showed that Gaussian beam profile and in particular, Bi-Convex lenses applied to both source and detector leads to a greater light penetration depth in the liquid phantom close to that of a Laser source.</abstract><pub>IOP Publishing</pub><doi>10.1088/2057-1976/ab42d9</doi><tpages>14</tpages><orcidid>https://orcid.org/0000-0001-5928-8668</orcidid><orcidid>https://orcid.org/0000-0002-8758-9991</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 2057-1976
ispartof Biomedical physics & engineering express, 2019-09, Vol.5 (6), p.65004
issn 2057-1976
2057-1976
language eng
recordid cdi_crossref_primary_10_1088_2057_1976_ab42d9
source IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link
subjects biomedical optic
instrumentation
monte carlo simulation
near infrared spectroscopy
optical sensors
title Enhancement of optical penetration depth of LED-based NIRS systems by comparing different beam profiles
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-13T00%3A51%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-iop_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Enhancement%20of%20optical%20penetration%20depth%20of%20LED-based%20NIRS%20systems%20by%20comparing%20different%20beam%20profiles&rft.jtitle=Biomedical%20physics%20&%20engineering%20express&rft.au=Mirbagheri,%20Mahya&rft.date=2019-09-23&rft.volume=5&rft.issue=6&rft.spage=65004&rft.pages=65004-&rft.issn=2057-1976&rft.eissn=2057-1976&rft.coden=NJOPFM&rft_id=info:doi/10.1088/2057-1976/ab42d9&rft_dat=%3Ciop_cross%3Ebpexab42d9%3C/iop_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true