Refractive index Mach-Zehnder interferometer sensor based on tapered no-core fiber

A Mach-Zehnder interferometer sensor based on tapered no-core fiber (NCF) is proposed in this paper. Due to the multimode interference of the single-mode fiber (SMF)-NCF-SMF structure and the higher-order modes excited by the tapered structure, the sensor is more sensitive to the refractive index. T...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Laser physics 2021-04, Vol.31 (4), p.45101, Article 045101
Hauptverfasser: Zhao, Yeming, Tong, Zhengrong, Zhang, Weihua, Zhang, Jietong, Li, Jiaxin, Wang, Xue
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A Mach-Zehnder interferometer sensor based on tapered no-core fiber (NCF) is proposed in this paper. Due to the multimode interference of the single-mode fiber (SMF)-NCF-SMF structure and the higher-order modes excited by the tapered structure, the sensor is more sensitive to the refractive index. The refractive index sensitivities are 130.5 nm RIU-1 from 1.340 to 1.380, 330.0 nm RIU-1 from 1.380 to 1.420, and 906.0 nm RIU-1 from 1.420 to 1.440, respectively. The temperature sensitivity is 0.0595 nm degrees C-1 from 30 degrees C to 90 degrees C. This proposed sensor has a simple structure and low cost, which can be widely used for biological sensing.
ISSN:1054-660X
1555-6611
DOI:10.1088/1555-6611/abe241