Numerical solution and mathematical modelling of mass transport from medicated stent

Restenosis in arteries is a major problem which can be controlled by using medicated stents. The controlled drug transport from medicated stents has a great effect in decreasing restenosis in arteries. Drug is coated on stents to keep away from the re-narrowing of the artery wall. This device has an...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Physica scripta 2022-06, Vol.97 (6), p.65709
Hauptverfasser: Ali, Akhtar, Hussain, Majid, Inc, Mustafa, Hussan, Muhammad, Rahman, Jamshaid Ul
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 6
container_start_page 65709
container_title Physica scripta
container_volume 97
creator Ali, Akhtar
Hussain, Majid
Inc, Mustafa
Hussan, Muhammad
Rahman, Jamshaid Ul
description Restenosis in arteries is a major problem which can be controlled by using medicated stents. The controlled drug transport from medicated stents has a great effect in decreasing restenosis in arteries. Drug is coated on stents to keep away from the re-narrowing of the artery wall. This device has an advantage of a flexible time delivery of a curative drug to the adjoining blood vessel tissues. The aim of this study is to formulate a mathematical model which describe the process of drug transport from arterial wall and medicated stent. For this purpose, a 3D model is investigated to measure the impact of mass transport from drug eluting stent. The blood flow is modelled by dimensionless Navier stokes equations and the concentration of drug is driven by dimensionless’ convection diffusion equation. The effect of diffusive and advective forces are discovered and these forces can be used to control the drug mass transport. Moreover, the effect of dimensionless parameters such as Peclet number P e , porosity k and R e on mass transport from medicated stent and tissue layers is investigated. Characteristic Based Split Galerkin (CBSG) technique is applied to solve the dimensionless equations. In the application of stent-based drug delivery, the governing equations in this exploration give the premise of a plan for examining and computing mass transport in medicated stent and artery wall. The numerical results support to offer a good insight into the possible impacts of various parameters.
doi_str_mv 10.1088/1402-4896/ac6f8d
format Article
fullrecord <record><control><sourceid>iop_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1088_1402_4896_ac6f8d</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>psac6f8d</sourcerecordid><originalsourceid>FETCH-LOGICAL-c311t-8917cf8902265c3c9afb26ee7920ca4428f36ce92d7b424b501953b61d4bbc283</originalsourceid><addsrcrecordid>eNp9kDlPxDAQhS0EEsvRU7qiIuz4iGOXaMUlraBZasvxAVklcWR7C_49WRZRIZoZad57o6cPoSsCtwSkXBIOtOJSiaWxIkh3hBa_p2O0AGCkkoqrU3SW8xaACirUAm1edoNPnTU9zrHflS6O2IwOD6Z8-Hl8K0N0vu-78R3HMCs545LMmKeYCg4pDnjwbjYW73AufiwX6CSYPvvLn32O3h7uN6unav36-Ly6W1eWEVLmOqSxQSqgVNSWWWVCS4X3jaJgDedUBiasV9Q1Lae8rYGomrWCON62lkp2juDw16aYc_JBT6kbTPrUBPSeit4j0HsE-kBljtwcIl2c9Dbu0jgX_M9-_Yd9ylo1WmgQdQNKTy6wL0SkciA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Numerical solution and mathematical modelling of mass transport from medicated stent</title><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><creator>Ali, Akhtar ; Hussain, Majid ; Inc, Mustafa ; Hussan, Muhammad ; Rahman, Jamshaid Ul</creator><creatorcontrib>Ali, Akhtar ; Hussain, Majid ; Inc, Mustafa ; Hussan, Muhammad ; Rahman, Jamshaid Ul</creatorcontrib><description>Restenosis in arteries is a major problem which can be controlled by using medicated stents. The controlled drug transport from medicated stents has a great effect in decreasing restenosis in arteries. Drug is coated on stents to keep away from the re-narrowing of the artery wall. This device has an advantage of a flexible time delivery of a curative drug to the adjoining blood vessel tissues. The aim of this study is to formulate a mathematical model which describe the process of drug transport from arterial wall and medicated stent. For this purpose, a 3D model is investigated to measure the impact of mass transport from drug eluting stent. The blood flow is modelled by dimensionless Navier stokes equations and the concentration of drug is driven by dimensionless’ convection diffusion equation. The effect of diffusive and advective forces are discovered and these forces can be used to control the drug mass transport. Moreover, the effect of dimensionless parameters such as Peclet number P e , porosity k and R e on mass transport from medicated stent and tissue layers is investigated. Characteristic Based Split Galerkin (CBSG) technique is applied to solve the dimensionless equations. In the application of stent-based drug delivery, the governing equations in this exploration give the premise of a plan for examining and computing mass transport in medicated stent and artery wall. The numerical results support to offer a good insight into the possible impacts of various parameters.</description><identifier>ISSN: 0031-8949</identifier><identifier>EISSN: 1402-4896</identifier><identifier>DOI: 10.1088/1402-4896/ac6f8d</identifier><identifier>CODEN: PHSTBO</identifier><language>eng</language><publisher>IOP Publishing</publisher><subject>characteristic based split Galerkin method ; drug eluting stent ; numerical simulation</subject><ispartof>Physica scripta, 2022-06, Vol.97 (6), p.65709</ispartof><rights>2022 IOP Publishing Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c311t-8917cf8902265c3c9afb26ee7920ca4428f36ce92d7b424b501953b61d4bbc283</citedby><cites>FETCH-LOGICAL-c311t-8917cf8902265c3c9afb26ee7920ca4428f36ce92d7b424b501953b61d4bbc283</cites><orcidid>0000-0003-4996-8373</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/1402-4896/ac6f8d/pdf$$EPDF$$P50$$Giop$$H</linktopdf><link.rule.ids>315,782,786,27931,27932,53853,53900</link.rule.ids></links><search><creatorcontrib>Ali, Akhtar</creatorcontrib><creatorcontrib>Hussain, Majid</creatorcontrib><creatorcontrib>Inc, Mustafa</creatorcontrib><creatorcontrib>Hussan, Muhammad</creatorcontrib><creatorcontrib>Rahman, Jamshaid Ul</creatorcontrib><title>Numerical solution and mathematical modelling of mass transport from medicated stent</title><title>Physica scripta</title><addtitle>PS</addtitle><addtitle>Phys. Scr</addtitle><description>Restenosis in arteries is a major problem which can be controlled by using medicated stents. The controlled drug transport from medicated stents has a great effect in decreasing restenosis in arteries. Drug is coated on stents to keep away from the re-narrowing of the artery wall. This device has an advantage of a flexible time delivery of a curative drug to the adjoining blood vessel tissues. The aim of this study is to formulate a mathematical model which describe the process of drug transport from arterial wall and medicated stent. For this purpose, a 3D model is investigated to measure the impact of mass transport from drug eluting stent. The blood flow is modelled by dimensionless Navier stokes equations and the concentration of drug is driven by dimensionless’ convection diffusion equation. The effect of diffusive and advective forces are discovered and these forces can be used to control the drug mass transport. Moreover, the effect of dimensionless parameters such as Peclet number P e , porosity k and R e on mass transport from medicated stent and tissue layers is investigated. Characteristic Based Split Galerkin (CBSG) technique is applied to solve the dimensionless equations. In the application of stent-based drug delivery, the governing equations in this exploration give the premise of a plan for examining and computing mass transport in medicated stent and artery wall. The numerical results support to offer a good insight into the possible impacts of various parameters.</description><subject>characteristic based split Galerkin method</subject><subject>drug eluting stent</subject><subject>numerical simulation</subject><issn>0031-8949</issn><issn>1402-4896</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNp9kDlPxDAQhS0EEsvRU7qiIuz4iGOXaMUlraBZasvxAVklcWR7C_49WRZRIZoZad57o6cPoSsCtwSkXBIOtOJSiaWxIkh3hBa_p2O0AGCkkoqrU3SW8xaACirUAm1edoNPnTU9zrHflS6O2IwOD6Z8-Hl8K0N0vu-78R3HMCs545LMmKeYCg4pDnjwbjYW73AufiwX6CSYPvvLn32O3h7uN6unav36-Ly6W1eWEVLmOqSxQSqgVNSWWWVCS4X3jaJgDedUBiasV9Q1Lae8rYGomrWCON62lkp2juDw16aYc_JBT6kbTPrUBPSeit4j0HsE-kBljtwcIl2c9Dbu0jgX_M9-_Yd9ylo1WmgQdQNKTy6wL0SkciA</recordid><startdate>20220601</startdate><enddate>20220601</enddate><creator>Ali, Akhtar</creator><creator>Hussain, Majid</creator><creator>Inc, Mustafa</creator><creator>Hussan, Muhammad</creator><creator>Rahman, Jamshaid Ul</creator><general>IOP Publishing</general><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0003-4996-8373</orcidid></search><sort><creationdate>20220601</creationdate><title>Numerical solution and mathematical modelling of mass transport from medicated stent</title><author>Ali, Akhtar ; Hussain, Majid ; Inc, Mustafa ; Hussan, Muhammad ; Rahman, Jamshaid Ul</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c311t-8917cf8902265c3c9afb26ee7920ca4428f36ce92d7b424b501953b61d4bbc283</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>characteristic based split Galerkin method</topic><topic>drug eluting stent</topic><topic>numerical simulation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ali, Akhtar</creatorcontrib><creatorcontrib>Hussain, Majid</creatorcontrib><creatorcontrib>Inc, Mustafa</creatorcontrib><creatorcontrib>Hussan, Muhammad</creatorcontrib><creatorcontrib>Rahman, Jamshaid Ul</creatorcontrib><collection>CrossRef</collection><jtitle>Physica scripta</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ali, Akhtar</au><au>Hussain, Majid</au><au>Inc, Mustafa</au><au>Hussan, Muhammad</au><au>Rahman, Jamshaid Ul</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Numerical solution and mathematical modelling of mass transport from medicated stent</atitle><jtitle>Physica scripta</jtitle><stitle>PS</stitle><addtitle>Phys. Scr</addtitle><date>2022-06-01</date><risdate>2022</risdate><volume>97</volume><issue>6</issue><spage>65709</spage><pages>65709-</pages><issn>0031-8949</issn><eissn>1402-4896</eissn><coden>PHSTBO</coden><abstract>Restenosis in arteries is a major problem which can be controlled by using medicated stents. The controlled drug transport from medicated stents has a great effect in decreasing restenosis in arteries. Drug is coated on stents to keep away from the re-narrowing of the artery wall. This device has an advantage of a flexible time delivery of a curative drug to the adjoining blood vessel tissues. The aim of this study is to formulate a mathematical model which describe the process of drug transport from arterial wall and medicated stent. For this purpose, a 3D model is investigated to measure the impact of mass transport from drug eluting stent. The blood flow is modelled by dimensionless Navier stokes equations and the concentration of drug is driven by dimensionless’ convection diffusion equation. The effect of diffusive and advective forces are discovered and these forces can be used to control the drug mass transport. Moreover, the effect of dimensionless parameters such as Peclet number P e , porosity k and R e on mass transport from medicated stent and tissue layers is investigated. Characteristic Based Split Galerkin (CBSG) technique is applied to solve the dimensionless equations. In the application of stent-based drug delivery, the governing equations in this exploration give the premise of a plan for examining and computing mass transport in medicated stent and artery wall. The numerical results support to offer a good insight into the possible impacts of various parameters.</abstract><pub>IOP Publishing</pub><doi>10.1088/1402-4896/ac6f8d</doi><tpages>15</tpages><orcidid>https://orcid.org/0000-0003-4996-8373</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0031-8949
ispartof Physica scripta, 2022-06, Vol.97 (6), p.65709
issn 0031-8949
1402-4896
language eng
recordid cdi_crossref_primary_10_1088_1402_4896_ac6f8d
source IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link
subjects characteristic based split Galerkin method
drug eluting stent
numerical simulation
title Numerical solution and mathematical modelling of mass transport from medicated stent
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-05T01%3A37%3A22IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-iop_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Numerical%20solution%20and%20mathematical%20modelling%20of%20mass%20transport%20from%20medicated%20stent&rft.jtitle=Physica%20scripta&rft.au=Ali,%20Akhtar&rft.date=2022-06-01&rft.volume=97&rft.issue=6&rft.spage=65709&rft.pages=65709-&rft.issn=0031-8949&rft.eissn=1402-4896&rft.coden=PHSTBO&rft_id=info:doi/10.1088/1402-4896/ac6f8d&rft_dat=%3Ciop_cross%3Epsac6f8d%3C/iop_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true