A Monte Carlo study on the secondary neutron generation by oxygen ion beams for radiotherapy and its comparison to lighter ions

To study the secondary neutrons generated by primary oxygen beams for cancer treatment and compare the results to those from primary protons, helium, and carbon ions. This information can provide useful insight into the positioning of neutron detectors in phantom for future experimental dose assessm...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Physics in medicine & biology 2024-01, Vol.69 (1), p.15027
Hauptverfasser: Geser, Federico A, Stabilini, Alberto, Christensen, Jeppe B, Muñoz, Iván D, Yukihara, Eduardo G, Jäkel, Oliver, Vedelago, José
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 1
container_start_page 15027
container_title Physics in medicine & biology
container_volume 69
creator Geser, Federico A
Stabilini, Alberto
Christensen, Jeppe B
Muñoz, Iván D
Yukihara, Eduardo G
Jäkel, Oliver
Vedelago, José
description To study the secondary neutrons generated by primary oxygen beams for cancer treatment and compare the results to those from primary protons, helium, and carbon ions. This information can provide useful insight into the positioning of neutron detectors in phantom for future experimental dose assessments. Mono-energetic oxygen beams and spread-out Bragg peaks were simulated using the Monte Carlo particle transport codes , tool for particle simulation, and Monte Carlo N-Particle, with energies within the therapeutic range. The energy and angular distribution of the secondary neutrons were quantified. The secondary neutron spectra generated by primary oxygen beams present the same qualitative trend as for other primary ions. The energy distributions resemble continuous spectra with one peak in the thermal/epithermal region, and one other peak in the fast/relativistic region, with the most probable energy ranging from 94 up to 277 MeV and maximum energies exceeding 500 MeV. The angular distribution of the secondary neutrons is mainly downstream-directed for the fast/relativistic energies, whereas the thermal/epithermal neutrons present a more isotropic propagation. When comparing the four different primary ions, there is a significant increase in the most probable energy as well as the number of secondary neutrons per primary particle when increasing the mass of the primaries. Most previous studies have only presented results of secondary neutrons generated by primary proton beams. In this work, secondary neutrons generated by primary oxygen beams are presented, and the obtained energy and angular spectra are added as supplementary material. Furthermore, a comparison of the secondary neutron generation by the different primary ions is given, which can be used as the starting point for future studies on treatment plan comparison and secondary neutron dose optimisation. The distal penumbra after the maximum dose deposition appears to be a suitable location for in-phantom dose assessments.
doi_str_mv 10.1088/1361-6560/ad0f45
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1088_1361_6560_ad0f45</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2893839927</sourcerecordid><originalsourceid>FETCH-LOGICAL-c368t-3fa35ecef557765dc32656ac97d78649ee43eec86525626d7701022446b41dd43</originalsourceid><addsrcrecordid>eNp9kD1P3TAUhq2qCC4fe6fKWzsQ8EdsxyO6agGJigVmy9c-gaAkTm1H6p346zhcYEKdfHz0vK90HoS-UXJGSdOcUy5pJYUk59aTthZf0Opj9RWtCOG00lSIA3SY0hMhlDas3kcHXGktuOQr9HyB_4QxA17b2Aec8uy3OIw4PwJO4MLobdziEeYcy_YBRog2d2XcFOzftizw6w_skHAbIo7Wd6Gko5222I4edzlhF4bJxi4txQH33cNjhrgE0zHaa22f4OTtPUL3v3_dra-qm9vL6_XFTeW4bHLFW8sFOGiFUEoK7zgrN1qnlVeNrDVAzQFcIwUTkkmvFKGEsbqWm5p6X_Mj9HPXO8Xwd4aUzdAlB31vRwhzMqzRvOFaM1VQskNdDClFaM0Uu6FoMJSYRbtZHJvFsdlpL5Hvb-3zZgD_EXj3XIDTHdCFyTyFOY7l2P_1_fgEn4aNkdpQQ6ggTJnJt_wFIf6aJw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2893839927</pqid></control><display><type>article</type><title>A Monte Carlo study on the secondary neutron generation by oxygen ion beams for radiotherapy and its comparison to lighter ions</title><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><creator>Geser, Federico A ; Stabilini, Alberto ; Christensen, Jeppe B ; Muñoz, Iván D ; Yukihara, Eduardo G ; Jäkel, Oliver ; Vedelago, José</creator><creatorcontrib>Geser, Federico A ; Stabilini, Alberto ; Christensen, Jeppe B ; Muñoz, Iván D ; Yukihara, Eduardo G ; Jäkel, Oliver ; Vedelago, José</creatorcontrib><description>To study the secondary neutrons generated by primary oxygen beams for cancer treatment and compare the results to those from primary protons, helium, and carbon ions. This information can provide useful insight into the positioning of neutron detectors in phantom for future experimental dose assessments. Mono-energetic oxygen beams and spread-out Bragg peaks were simulated using the Monte Carlo particle transport codes , tool for particle simulation, and Monte Carlo N-Particle, with energies within the therapeutic range. The energy and angular distribution of the secondary neutrons were quantified. The secondary neutron spectra generated by primary oxygen beams present the same qualitative trend as for other primary ions. The energy distributions resemble continuous spectra with one peak in the thermal/epithermal region, and one other peak in the fast/relativistic region, with the most probable energy ranging from 94 up to 277 MeV and maximum energies exceeding 500 MeV. The angular distribution of the secondary neutrons is mainly downstream-directed for the fast/relativistic energies, whereas the thermal/epithermal neutrons present a more isotropic propagation. When comparing the four different primary ions, there is a significant increase in the most probable energy as well as the number of secondary neutrons per primary particle when increasing the mass of the primaries. Most previous studies have only presented results of secondary neutrons generated by primary proton beams. In this work, secondary neutrons generated by primary oxygen beams are presented, and the obtained energy and angular spectra are added as supplementary material. Furthermore, a comparison of the secondary neutron generation by the different primary ions is given, which can be used as the starting point for future studies on treatment plan comparison and secondary neutron dose optimisation. The distal penumbra after the maximum dose deposition appears to be a suitable location for in-phantom dose assessments.</description><identifier>ISSN: 0031-9155</identifier><identifier>EISSN: 1361-6560</identifier><identifier>DOI: 10.1088/1361-6560/ad0f45</identifier><identifier>PMID: 37995363</identifier><identifier>CODEN: PHMBA7</identifier><language>eng</language><publisher>England: IOP Publishing</publisher><subject>Monte Carlo simulations ; oxygen ions ; secondary neutrons</subject><ispartof>Physics in medicine &amp; biology, 2024-01, Vol.69 (1), p.15027</ispartof><rights>2024 Institute of Physics and Engineering in Medicine</rights><rights>2024 Institute of Physics and Engineering in Medicine.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c368t-3fa35ecef557765dc32656ac97d78649ee43eec86525626d7701022446b41dd43</citedby><cites>FETCH-LOGICAL-c368t-3fa35ecef557765dc32656ac97d78649ee43eec86525626d7701022446b41dd43</cites><orcidid>0000-0001-9823-1250 ; 0000-0002-6894-381X ; 0000-0002-4615-6698 ; 0000-0001-5510-9749 ; 0000-0002-1452-0862 ; 0000-0001-5183-3705 ; 0000-0002-6056-9747</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/1361-6560/ad0f45/pdf$$EPDF$$P50$$Giop$$H</linktopdf><link.rule.ids>314,780,784,27924,27925,53846,53893</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/37995363$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Geser, Federico A</creatorcontrib><creatorcontrib>Stabilini, Alberto</creatorcontrib><creatorcontrib>Christensen, Jeppe B</creatorcontrib><creatorcontrib>Muñoz, Iván D</creatorcontrib><creatorcontrib>Yukihara, Eduardo G</creatorcontrib><creatorcontrib>Jäkel, Oliver</creatorcontrib><creatorcontrib>Vedelago, José</creatorcontrib><title>A Monte Carlo study on the secondary neutron generation by oxygen ion beams for radiotherapy and its comparison to lighter ions</title><title>Physics in medicine &amp; biology</title><addtitle>PMB</addtitle><addtitle>Phys. Med. Biol</addtitle><description>To study the secondary neutrons generated by primary oxygen beams for cancer treatment and compare the results to those from primary protons, helium, and carbon ions. This information can provide useful insight into the positioning of neutron detectors in phantom for future experimental dose assessments. Mono-energetic oxygen beams and spread-out Bragg peaks were simulated using the Monte Carlo particle transport codes , tool for particle simulation, and Monte Carlo N-Particle, with energies within the therapeutic range. The energy and angular distribution of the secondary neutrons were quantified. The secondary neutron spectra generated by primary oxygen beams present the same qualitative trend as for other primary ions. The energy distributions resemble continuous spectra with one peak in the thermal/epithermal region, and one other peak in the fast/relativistic region, with the most probable energy ranging from 94 up to 277 MeV and maximum energies exceeding 500 MeV. The angular distribution of the secondary neutrons is mainly downstream-directed for the fast/relativistic energies, whereas the thermal/epithermal neutrons present a more isotropic propagation. When comparing the four different primary ions, there is a significant increase in the most probable energy as well as the number of secondary neutrons per primary particle when increasing the mass of the primaries. Most previous studies have only presented results of secondary neutrons generated by primary proton beams. In this work, secondary neutrons generated by primary oxygen beams are presented, and the obtained energy and angular spectra are added as supplementary material. Furthermore, a comparison of the secondary neutron generation by the different primary ions is given, which can be used as the starting point for future studies on treatment plan comparison and secondary neutron dose optimisation. The distal penumbra after the maximum dose deposition appears to be a suitable location for in-phantom dose assessments.</description><subject>Monte Carlo simulations</subject><subject>oxygen ions</subject><subject>secondary neutrons</subject><issn>0031-9155</issn><issn>1361-6560</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp9kD1P3TAUhq2qCC4fe6fKWzsQ8EdsxyO6agGJigVmy9c-gaAkTm1H6p346zhcYEKdfHz0vK90HoS-UXJGSdOcUy5pJYUk59aTthZf0Opj9RWtCOG00lSIA3SY0hMhlDas3kcHXGktuOQr9HyB_4QxA17b2Aec8uy3OIw4PwJO4MLobdziEeYcy_YBRog2d2XcFOzftizw6w_skHAbIo7Wd6Gko5222I4edzlhF4bJxi4txQH33cNjhrgE0zHaa22f4OTtPUL3v3_dra-qm9vL6_XFTeW4bHLFW8sFOGiFUEoK7zgrN1qnlVeNrDVAzQFcIwUTkkmvFKGEsbqWm5p6X_Mj9HPXO8Xwd4aUzdAlB31vRwhzMqzRvOFaM1VQskNdDClFaM0Uu6FoMJSYRbtZHJvFsdlpL5Hvb-3zZgD_EXj3XIDTHdCFyTyFOY7l2P_1_fgEn4aNkdpQQ6ggTJnJt_wFIf6aJw</recordid><startdate>20240107</startdate><enddate>20240107</enddate><creator>Geser, Federico A</creator><creator>Stabilini, Alberto</creator><creator>Christensen, Jeppe B</creator><creator>Muñoz, Iván D</creator><creator>Yukihara, Eduardo G</creator><creator>Jäkel, Oliver</creator><creator>Vedelago, José</creator><general>IOP Publishing</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-9823-1250</orcidid><orcidid>https://orcid.org/0000-0002-6894-381X</orcidid><orcidid>https://orcid.org/0000-0002-4615-6698</orcidid><orcidid>https://orcid.org/0000-0001-5510-9749</orcidid><orcidid>https://orcid.org/0000-0002-1452-0862</orcidid><orcidid>https://orcid.org/0000-0001-5183-3705</orcidid><orcidid>https://orcid.org/0000-0002-6056-9747</orcidid></search><sort><creationdate>20240107</creationdate><title>A Monte Carlo study on the secondary neutron generation by oxygen ion beams for radiotherapy and its comparison to lighter ions</title><author>Geser, Federico A ; Stabilini, Alberto ; Christensen, Jeppe B ; Muñoz, Iván D ; Yukihara, Eduardo G ; Jäkel, Oliver ; Vedelago, José</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c368t-3fa35ecef557765dc32656ac97d78649ee43eec86525626d7701022446b41dd43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Monte Carlo simulations</topic><topic>oxygen ions</topic><topic>secondary neutrons</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Geser, Federico A</creatorcontrib><creatorcontrib>Stabilini, Alberto</creatorcontrib><creatorcontrib>Christensen, Jeppe B</creatorcontrib><creatorcontrib>Muñoz, Iván D</creatorcontrib><creatorcontrib>Yukihara, Eduardo G</creatorcontrib><creatorcontrib>Jäkel, Oliver</creatorcontrib><creatorcontrib>Vedelago, José</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Physics in medicine &amp; biology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Geser, Federico A</au><au>Stabilini, Alberto</au><au>Christensen, Jeppe B</au><au>Muñoz, Iván D</au><au>Yukihara, Eduardo G</au><au>Jäkel, Oliver</au><au>Vedelago, José</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Monte Carlo study on the secondary neutron generation by oxygen ion beams for radiotherapy and its comparison to lighter ions</atitle><jtitle>Physics in medicine &amp; biology</jtitle><stitle>PMB</stitle><addtitle>Phys. Med. Biol</addtitle><date>2024-01-07</date><risdate>2024</risdate><volume>69</volume><issue>1</issue><spage>15027</spage><pages>15027-</pages><issn>0031-9155</issn><eissn>1361-6560</eissn><coden>PHMBA7</coden><abstract>To study the secondary neutrons generated by primary oxygen beams for cancer treatment and compare the results to those from primary protons, helium, and carbon ions. This information can provide useful insight into the positioning of neutron detectors in phantom for future experimental dose assessments. Mono-energetic oxygen beams and spread-out Bragg peaks were simulated using the Monte Carlo particle transport codes , tool for particle simulation, and Monte Carlo N-Particle, with energies within the therapeutic range. The energy and angular distribution of the secondary neutrons were quantified. The secondary neutron spectra generated by primary oxygen beams present the same qualitative trend as for other primary ions. The energy distributions resemble continuous spectra with one peak in the thermal/epithermal region, and one other peak in the fast/relativistic region, with the most probable energy ranging from 94 up to 277 MeV and maximum energies exceeding 500 MeV. The angular distribution of the secondary neutrons is mainly downstream-directed for the fast/relativistic energies, whereas the thermal/epithermal neutrons present a more isotropic propagation. When comparing the four different primary ions, there is a significant increase in the most probable energy as well as the number of secondary neutrons per primary particle when increasing the mass of the primaries. Most previous studies have only presented results of secondary neutrons generated by primary proton beams. In this work, secondary neutrons generated by primary oxygen beams are presented, and the obtained energy and angular spectra are added as supplementary material. Furthermore, a comparison of the secondary neutron generation by the different primary ions is given, which can be used as the starting point for future studies on treatment plan comparison and secondary neutron dose optimisation. The distal penumbra after the maximum dose deposition appears to be a suitable location for in-phantom dose assessments.</abstract><cop>England</cop><pub>IOP Publishing</pub><pmid>37995363</pmid><doi>10.1088/1361-6560/ad0f45</doi><tpages>16</tpages><orcidid>https://orcid.org/0000-0001-9823-1250</orcidid><orcidid>https://orcid.org/0000-0002-6894-381X</orcidid><orcidid>https://orcid.org/0000-0002-4615-6698</orcidid><orcidid>https://orcid.org/0000-0001-5510-9749</orcidid><orcidid>https://orcid.org/0000-0002-1452-0862</orcidid><orcidid>https://orcid.org/0000-0001-5183-3705</orcidid><orcidid>https://orcid.org/0000-0002-6056-9747</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0031-9155
ispartof Physics in medicine & biology, 2024-01, Vol.69 (1), p.15027
issn 0031-9155
1361-6560
language eng
recordid cdi_crossref_primary_10_1088_1361_6560_ad0f45
source IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link
subjects Monte Carlo simulations
oxygen ions
secondary neutrons
title A Monte Carlo study on the secondary neutron generation by oxygen ion beams for radiotherapy and its comparison to lighter ions
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T02%3A16%3A06IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Monte%20Carlo%20study%20on%20the%20secondary%20neutron%20generation%20by%20oxygen%20ion%20beams%20for%20radiotherapy%20and%20its%20comparison%20to%20lighter%20ions&rft.jtitle=Physics%20in%20medicine%20&%20biology&rft.au=Geser,%20Federico%20A&rft.date=2024-01-07&rft.volume=69&rft.issue=1&rft.spage=15027&rft.pages=15027-&rft.issn=0031-9155&rft.eissn=1361-6560&rft.coden=PHMBA7&rft_id=info:doi/10.1088/1361-6560/ad0f45&rft_dat=%3Cproquest_cross%3E2893839927%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2893839927&rft_id=info:pmid/37995363&rfr_iscdi=true