Adaptation of metrology-grade ac current source in velocity mode of Planck-Balance 2: direct referencing induced voltages with ac quantum voltage standard

The adaptation of developed metrology-grade ac current source (MCS) to the velocity mode of measurements of the Planck-Balance 2 as a means for generating ac mechanical oscillations is presented. The universality in operating with the MCS unit especially practical for the Planck-Balance setup for fr...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Measurement science & technology 2024-01, Vol.35 (1), p.15026
Hauptverfasser: Vasilyan, Suren, Rogge, Norbert, Preißler, Hannes, Starkloff, Michael, Schubert, Marco, Fröhlich, Thomas
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 1
container_start_page 15026
container_title Measurement science & technology
container_volume 35
creator Vasilyan, Suren
Rogge, Norbert
Preißler, Hannes
Starkloff, Michael
Schubert, Marco
Fröhlich, Thomas
description The adaptation of developed metrology-grade ac current source (MCS) to the velocity mode of measurements of the Planck-Balance 2 as a means for generating ac mechanical oscillations is presented. The universality in operating with the MCS unit especially practical for the Planck-Balance setup for frequencies of 0.1 Hz–20 Hz (including but not limited to the negligence of a broader range of 0.01 Hz up to several hundred Hz) and for amplitudes of up to 10 mA with 16 (offset with 14)-bit effective resolution is demonstrated. MCS allows generating complex ac waveform signals as waveform synthesizers by adding to the original signal an extra five independent harmonic components, each of which with an adjustable resolution of 10 ns for phase and 16-bit for amplitude. Additionally, the MCS is supported by an external clock at 10 MHz frequency which serves also as a common reference time base for the comparison between the direct output signal of MCS, or of the induced voltage in the coil of the Planck-Balance resulting due to the applied current by MCS, with the ac quantum voltage standard at the required accuracy levels.
doi_str_mv 10.1088/1361-6501/ad006c
format Article
fullrecord <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_1088_1361_6501_ad006c</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1088_1361_6501_ad006c</sourcerecordid><originalsourceid>FETCH-LOGICAL-c238t-987b703b871c787e6460c7aad5427122cb5e247ce8b7d484611c69e1798907d63</originalsourceid><addsrcrecordid>eNo9kE1PwzAMhiMEEmNw55g_UOb0Kym3MfElTYIDnKvU8UqhbUaSDu2v8GtpNeD0SrYf23oYuxRwJUCphUhyEeUZiIU2ADkesdl_6ZjNoMhkBHGSnLIz798BQEJRzNj30uht0KGxPbcb3lFwtrX1PqqdNsQ1chycoz5wbweHxJue76i12IQ97-w4MlLPre7xI7rRUxKPr7lpHGHgjjY0wtj09QiaAcnwnW2Drsnzrya8TQc-B92HoftrcB90b7Qz5-xko1tPF785Z693ty-rh2j9dP-4Wq4jjBMVokLJSkJSKSlQKkl5mgNKrU2WxlLEMVYZxalEUpU0qUpzITAvSMhCFSBNnswZHPais96PL5db13Ta7UsB5eS2nESWk8jy4Db5AdAWb34</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Adaptation of metrology-grade ac current source in velocity mode of Planck-Balance 2: direct referencing induced voltages with ac quantum voltage standard</title><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><creator>Vasilyan, Suren ; Rogge, Norbert ; Preißler, Hannes ; Starkloff, Michael ; Schubert, Marco ; Fröhlich, Thomas</creator><creatorcontrib>Vasilyan, Suren ; Rogge, Norbert ; Preißler, Hannes ; Starkloff, Michael ; Schubert, Marco ; Fröhlich, Thomas</creatorcontrib><description>The adaptation of developed metrology-grade ac current source (MCS) to the velocity mode of measurements of the Planck-Balance 2 as a means for generating ac mechanical oscillations is presented. The universality in operating with the MCS unit especially practical for the Planck-Balance setup for frequencies of 0.1 Hz–20 Hz (including but not limited to the negligence of a broader range of 0.01 Hz up to several hundred Hz) and for amplitudes of up to 10 mA with 16 (offset with 14)-bit effective resolution is demonstrated. MCS allows generating complex ac waveform signals as waveform synthesizers by adding to the original signal an extra five independent harmonic components, each of which with an adjustable resolution of 10 ns for phase and 16-bit for amplitude. Additionally, the MCS is supported by an external clock at 10 MHz frequency which serves also as a common reference time base for the comparison between the direct output signal of MCS, or of the induced voltage in the coil of the Planck-Balance resulting due to the applied current by MCS, with the ac quantum voltage standard at the required accuracy levels.</description><identifier>ISSN: 0957-0233</identifier><identifier>EISSN: 1361-6501</identifier><identifier>DOI: 10.1088/1361-6501/ad006c</identifier><language>eng</language><ispartof>Measurement science &amp; technology, 2024-01, Vol.35 (1), p.15026</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c238t-987b703b871c787e6460c7aad5427122cb5e247ce8b7d484611c69e1798907d63</cites><orcidid>0000-0001-9399-3504 ; 0000-0001-5614-3180 ; 0000-0002-6060-7248</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Vasilyan, Suren</creatorcontrib><creatorcontrib>Rogge, Norbert</creatorcontrib><creatorcontrib>Preißler, Hannes</creatorcontrib><creatorcontrib>Starkloff, Michael</creatorcontrib><creatorcontrib>Schubert, Marco</creatorcontrib><creatorcontrib>Fröhlich, Thomas</creatorcontrib><title>Adaptation of metrology-grade ac current source in velocity mode of Planck-Balance 2: direct referencing induced voltages with ac quantum voltage standard</title><title>Measurement science &amp; technology</title><description>The adaptation of developed metrology-grade ac current source (MCS) to the velocity mode of measurements of the Planck-Balance 2 as a means for generating ac mechanical oscillations is presented. The universality in operating with the MCS unit especially practical for the Planck-Balance setup for frequencies of 0.1 Hz–20 Hz (including but not limited to the negligence of a broader range of 0.01 Hz up to several hundred Hz) and for amplitudes of up to 10 mA with 16 (offset with 14)-bit effective resolution is demonstrated. MCS allows generating complex ac waveform signals as waveform synthesizers by adding to the original signal an extra five independent harmonic components, each of which with an adjustable resolution of 10 ns for phase and 16-bit for amplitude. Additionally, the MCS is supported by an external clock at 10 MHz frequency which serves also as a common reference time base for the comparison between the direct output signal of MCS, or of the induced voltage in the coil of the Planck-Balance resulting due to the applied current by MCS, with the ac quantum voltage standard at the required accuracy levels.</description><issn>0957-0233</issn><issn>1361-6501</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNo9kE1PwzAMhiMEEmNw55g_UOb0Kym3MfElTYIDnKvU8UqhbUaSDu2v8GtpNeD0SrYf23oYuxRwJUCphUhyEeUZiIU2ADkesdl_6ZjNoMhkBHGSnLIz798BQEJRzNj30uht0KGxPbcb3lFwtrX1PqqdNsQ1chycoz5wbweHxJue76i12IQ97-w4MlLPre7xI7rRUxKPr7lpHGHgjjY0wtj09QiaAcnwnW2Drsnzrya8TQc-B92HoftrcB90b7Qz5-xko1tPF785Z693ty-rh2j9dP-4Wq4jjBMVokLJSkJSKSlQKkl5mgNKrU2WxlLEMVYZxalEUpU0qUpzITAvSMhCFSBNnswZHPais96PL5db13Ta7UsB5eS2nESWk8jy4Db5AdAWb34</recordid><startdate>20240101</startdate><enddate>20240101</enddate><creator>Vasilyan, Suren</creator><creator>Rogge, Norbert</creator><creator>Preißler, Hannes</creator><creator>Starkloff, Michael</creator><creator>Schubert, Marco</creator><creator>Fröhlich, Thomas</creator><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0001-9399-3504</orcidid><orcidid>https://orcid.org/0000-0001-5614-3180</orcidid><orcidid>https://orcid.org/0000-0002-6060-7248</orcidid></search><sort><creationdate>20240101</creationdate><title>Adaptation of metrology-grade ac current source in velocity mode of Planck-Balance 2: direct referencing induced voltages with ac quantum voltage standard</title><author>Vasilyan, Suren ; Rogge, Norbert ; Preißler, Hannes ; Starkloff, Michael ; Schubert, Marco ; Fröhlich, Thomas</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c238t-987b703b871c787e6460c7aad5427122cb5e247ce8b7d484611c69e1798907d63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Vasilyan, Suren</creatorcontrib><creatorcontrib>Rogge, Norbert</creatorcontrib><creatorcontrib>Preißler, Hannes</creatorcontrib><creatorcontrib>Starkloff, Michael</creatorcontrib><creatorcontrib>Schubert, Marco</creatorcontrib><creatorcontrib>Fröhlich, Thomas</creatorcontrib><collection>CrossRef</collection><jtitle>Measurement science &amp; technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Vasilyan, Suren</au><au>Rogge, Norbert</au><au>Preißler, Hannes</au><au>Starkloff, Michael</au><au>Schubert, Marco</au><au>Fröhlich, Thomas</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Adaptation of metrology-grade ac current source in velocity mode of Planck-Balance 2: direct referencing induced voltages with ac quantum voltage standard</atitle><jtitle>Measurement science &amp; technology</jtitle><date>2024-01-01</date><risdate>2024</risdate><volume>35</volume><issue>1</issue><spage>15026</spage><pages>15026-</pages><issn>0957-0233</issn><eissn>1361-6501</eissn><abstract>The adaptation of developed metrology-grade ac current source (MCS) to the velocity mode of measurements of the Planck-Balance 2 as a means for generating ac mechanical oscillations is presented. The universality in operating with the MCS unit especially practical for the Planck-Balance setup for frequencies of 0.1 Hz–20 Hz (including but not limited to the negligence of a broader range of 0.01 Hz up to several hundred Hz) and for amplitudes of up to 10 mA with 16 (offset with 14)-bit effective resolution is demonstrated. MCS allows generating complex ac waveform signals as waveform synthesizers by adding to the original signal an extra five independent harmonic components, each of which with an adjustable resolution of 10 ns for phase and 16-bit for amplitude. Additionally, the MCS is supported by an external clock at 10 MHz frequency which serves also as a common reference time base for the comparison between the direct output signal of MCS, or of the induced voltage in the coil of the Planck-Balance resulting due to the applied current by MCS, with the ac quantum voltage standard at the required accuracy levels.</abstract><doi>10.1088/1361-6501/ad006c</doi><orcidid>https://orcid.org/0000-0001-9399-3504</orcidid><orcidid>https://orcid.org/0000-0001-5614-3180</orcidid><orcidid>https://orcid.org/0000-0002-6060-7248</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0957-0233
ispartof Measurement science & technology, 2024-01, Vol.35 (1), p.15026
issn 0957-0233
1361-6501
language eng
recordid cdi_crossref_primary_10_1088_1361_6501_ad006c
source IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link
title Adaptation of metrology-grade ac current source in velocity mode of Planck-Balance 2: direct referencing induced voltages with ac quantum voltage standard
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T17%3A07%3A06IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Adaptation%20of%20metrology-grade%20ac%20current%20source%20in%20velocity%20mode%20of%20Planck-Balance%202:%20direct%20referencing%20induced%20voltages%20with%20ac%20quantum%20voltage%20standard&rft.jtitle=Measurement%20science%20&%20technology&rft.au=Vasilyan,%20Suren&rft.date=2024-01-01&rft.volume=35&rft.issue=1&rft.spage=15026&rft.pages=15026-&rft.issn=0957-0233&rft.eissn=1361-6501&rft_id=info:doi/10.1088/1361-6501/ad006c&rft_dat=%3Ccrossref%3E10_1088_1361_6501_ad006c%3C/crossref%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true