Camera calibration approach using polarized light based on high-frequency component variance weighted entropy for pose measurement

The camera’s intrinsic parameters calibration directly affects monocular pose measurement accuracy. To improve the calibration accuracy of the camera’s intrinsic parameters, the polarizing device is used to eliminate the high-brightness areas in the images collected for camera calibration. However,...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Measurement science & technology 2023-11, Vol.34 (11), p.115015
Hauptverfasser: Zhang, Zimiao, He, Linjie, Wu, Yanan, Zhang, Fumin
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 11
container_start_page 115015
container_title Measurement science & technology
container_volume 34
creator Zhang, Zimiao
He, Linjie
Wu, Yanan
Zhang, Fumin
description The camera’s intrinsic parameters calibration directly affects monocular pose measurement accuracy. To improve the calibration accuracy of the camera’s intrinsic parameters, the polarizing device is used to eliminate the high-brightness areas in the images collected for camera calibration. However, an unsuitable polarizing angle will reduce the image’s contrast. This causes the texture information of the image to be lost or makes the extracted feature change in the direction of grayscale value decline, ultimately affecting the feature extraction. Aiming at this issue, this paper proposed a camera calibration approach using polarized light based on high-frequency component variance weighted entropy (HVE). We determined the suitable polarizing angle according to the two-dimensional homography matrix describing the mapping between the target plane and normalized imaging plane for each calibration location. Under the suitable polarizing angle, we determined the optimal exposure time according to the HVE. The images collected under suitable polarizing angles and the optimal exposure time were used to finish the camera calibration. The suitable polarizing angles and optimal exposure time can ensure the image’s contrast and texture information. The experimental findings demonstrate that our approach can increase the camera calibration accuracy and thus pose measurement accuracy. In the −45° to +45° range, the average pose measurement error is less than 0.05° and lowered by 0.08° (62%) compared to that performed using the intrinsic parameters calibrated with the images collected under no polarizing device. In the 0–20 mm range, the average pose measurement error is less than 0.028 mm and lowered by 0.05 mm (64%) compared to that performed using the intrinsic parameters calibrated with the images collected under no polarizing device.
doi_str_mv 10.1088/1361-6501/aceb7f
format Article
fullrecord <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_1088_1361_6501_aceb7f</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1088_1361_6501_aceb7f</sourcerecordid><originalsourceid>FETCH-LOGICAL-c196t-83ed3eae6e81e9c405350808ea3544caac704457b03b893c877f6a15c302a6613</originalsourceid><addsrcrecordid>eNo9kEtPwzAQhC0EEqVw5-g_ELqu40eOqOJRqRIXOEcbd9MGJXGwU1A58stxVMRpd2dm5_AxdivgToC1CyG1yLQCsUBHlanP2OxfOmczKJTJYCnlJbuK8R0ADBTFjP2ssKOA3GHbVAHHxvcchyF4dHt-iE2_44NvMTTftOVts9uPvMKY9pTbpzOrA30cqHdH7nw3-J76kX-mPPaO-BdNHymd1OCHI699SH2ReEcYD4G6ZFyzixrbSDd_c87eHh9eV8_Z5uVpvbrfZE4UesyspK0kJE1WUOFyUFKBBUsoVZ47RGcgz5WpQFa2kM4aU2sUyklYotZCzhmcel3wMQaqyyE0HYZjKaCcGJYTsHICVp4Yyl8QG2kb</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Camera calibration approach using polarized light based on high-frequency component variance weighted entropy for pose measurement</title><source>Institute of Physics Journals</source><creator>Zhang, Zimiao ; He, Linjie ; Wu, Yanan ; Zhang, Fumin</creator><creatorcontrib>Zhang, Zimiao ; He, Linjie ; Wu, Yanan ; Zhang, Fumin</creatorcontrib><description>The camera’s intrinsic parameters calibration directly affects monocular pose measurement accuracy. To improve the calibration accuracy of the camera’s intrinsic parameters, the polarizing device is used to eliminate the high-brightness areas in the images collected for camera calibration. However, an unsuitable polarizing angle will reduce the image’s contrast. This causes the texture information of the image to be lost or makes the extracted feature change in the direction of grayscale value decline, ultimately affecting the feature extraction. Aiming at this issue, this paper proposed a camera calibration approach using polarized light based on high-frequency component variance weighted entropy (HVE). We determined the suitable polarizing angle according to the two-dimensional homography matrix describing the mapping between the target plane and normalized imaging plane for each calibration location. Under the suitable polarizing angle, we determined the optimal exposure time according to the HVE. The images collected under suitable polarizing angles and the optimal exposure time were used to finish the camera calibration. The suitable polarizing angles and optimal exposure time can ensure the image’s contrast and texture information. The experimental findings demonstrate that our approach can increase the camera calibration accuracy and thus pose measurement accuracy. In the −45° to +45° range, the average pose measurement error is less than 0.05° and lowered by 0.08° (62%) compared to that performed using the intrinsic parameters calibrated with the images collected under no polarizing device. In the 0–20 mm range, the average pose measurement error is less than 0.028 mm and lowered by 0.05 mm (64%) compared to that performed using the intrinsic parameters calibrated with the images collected under no polarizing device.</description><identifier>ISSN: 0957-0233</identifier><identifier>EISSN: 1361-6501</identifier><identifier>DOI: 10.1088/1361-6501/aceb7f</identifier><language>eng</language><ispartof>Measurement science &amp; technology, 2023-11, Vol.34 (11), p.115015</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c196t-83ed3eae6e81e9c405350808ea3544caac704457b03b893c877f6a15c302a6613</cites><orcidid>0000-0003-4531-1913 ; 0000-0002-4516-5912 ; 0000-0001-7851-5045</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Zhang, Zimiao</creatorcontrib><creatorcontrib>He, Linjie</creatorcontrib><creatorcontrib>Wu, Yanan</creatorcontrib><creatorcontrib>Zhang, Fumin</creatorcontrib><title>Camera calibration approach using polarized light based on high-frequency component variance weighted entropy for pose measurement</title><title>Measurement science &amp; technology</title><description>The camera’s intrinsic parameters calibration directly affects monocular pose measurement accuracy. To improve the calibration accuracy of the camera’s intrinsic parameters, the polarizing device is used to eliminate the high-brightness areas in the images collected for camera calibration. However, an unsuitable polarizing angle will reduce the image’s contrast. This causes the texture information of the image to be lost or makes the extracted feature change in the direction of grayscale value decline, ultimately affecting the feature extraction. Aiming at this issue, this paper proposed a camera calibration approach using polarized light based on high-frequency component variance weighted entropy (HVE). We determined the suitable polarizing angle according to the two-dimensional homography matrix describing the mapping between the target plane and normalized imaging plane for each calibration location. Under the suitable polarizing angle, we determined the optimal exposure time according to the HVE. The images collected under suitable polarizing angles and the optimal exposure time were used to finish the camera calibration. The suitable polarizing angles and optimal exposure time can ensure the image’s contrast and texture information. The experimental findings demonstrate that our approach can increase the camera calibration accuracy and thus pose measurement accuracy. In the −45° to +45° range, the average pose measurement error is less than 0.05° and lowered by 0.08° (62%) compared to that performed using the intrinsic parameters calibrated with the images collected under no polarizing device. In the 0–20 mm range, the average pose measurement error is less than 0.028 mm and lowered by 0.05 mm (64%) compared to that performed using the intrinsic parameters calibrated with the images collected under no polarizing device.</description><issn>0957-0233</issn><issn>1361-6501</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNo9kEtPwzAQhC0EEqVw5-g_ELqu40eOqOJRqRIXOEcbd9MGJXGwU1A58stxVMRpd2dm5_AxdivgToC1CyG1yLQCsUBHlanP2OxfOmczKJTJYCnlJbuK8R0ADBTFjP2ssKOA3GHbVAHHxvcchyF4dHt-iE2_44NvMTTftOVts9uPvMKY9pTbpzOrA30cqHdH7nw3-J76kX-mPPaO-BdNHymd1OCHI699SH2ReEcYD4G6ZFyzixrbSDd_c87eHh9eV8_Z5uVpvbrfZE4UesyspK0kJE1WUOFyUFKBBUsoVZ47RGcgz5WpQFa2kM4aU2sUyklYotZCzhmcel3wMQaqyyE0HYZjKaCcGJYTsHICVp4Yyl8QG2kb</recordid><startdate>20231101</startdate><enddate>20231101</enddate><creator>Zhang, Zimiao</creator><creator>He, Linjie</creator><creator>Wu, Yanan</creator><creator>Zhang, Fumin</creator><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0003-4531-1913</orcidid><orcidid>https://orcid.org/0000-0002-4516-5912</orcidid><orcidid>https://orcid.org/0000-0001-7851-5045</orcidid></search><sort><creationdate>20231101</creationdate><title>Camera calibration approach using polarized light based on high-frequency component variance weighted entropy for pose measurement</title><author>Zhang, Zimiao ; He, Linjie ; Wu, Yanan ; Zhang, Fumin</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c196t-83ed3eae6e81e9c405350808ea3544caac704457b03b893c877f6a15c302a6613</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zhang, Zimiao</creatorcontrib><creatorcontrib>He, Linjie</creatorcontrib><creatorcontrib>Wu, Yanan</creatorcontrib><creatorcontrib>Zhang, Fumin</creatorcontrib><collection>CrossRef</collection><jtitle>Measurement science &amp; technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zhang, Zimiao</au><au>He, Linjie</au><au>Wu, Yanan</au><au>Zhang, Fumin</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Camera calibration approach using polarized light based on high-frequency component variance weighted entropy for pose measurement</atitle><jtitle>Measurement science &amp; technology</jtitle><date>2023-11-01</date><risdate>2023</risdate><volume>34</volume><issue>11</issue><spage>115015</spage><pages>115015-</pages><issn>0957-0233</issn><eissn>1361-6501</eissn><abstract>The camera’s intrinsic parameters calibration directly affects monocular pose measurement accuracy. To improve the calibration accuracy of the camera’s intrinsic parameters, the polarizing device is used to eliminate the high-brightness areas in the images collected for camera calibration. However, an unsuitable polarizing angle will reduce the image’s contrast. This causes the texture information of the image to be lost or makes the extracted feature change in the direction of grayscale value decline, ultimately affecting the feature extraction. Aiming at this issue, this paper proposed a camera calibration approach using polarized light based on high-frequency component variance weighted entropy (HVE). We determined the suitable polarizing angle according to the two-dimensional homography matrix describing the mapping between the target plane and normalized imaging plane for each calibration location. Under the suitable polarizing angle, we determined the optimal exposure time according to the HVE. The images collected under suitable polarizing angles and the optimal exposure time were used to finish the camera calibration. The suitable polarizing angles and optimal exposure time can ensure the image’s contrast and texture information. The experimental findings demonstrate that our approach can increase the camera calibration accuracy and thus pose measurement accuracy. In the −45° to +45° range, the average pose measurement error is less than 0.05° and lowered by 0.08° (62%) compared to that performed using the intrinsic parameters calibrated with the images collected under no polarizing device. In the 0–20 mm range, the average pose measurement error is less than 0.028 mm and lowered by 0.05 mm (64%) compared to that performed using the intrinsic parameters calibrated with the images collected under no polarizing device.</abstract><doi>10.1088/1361-6501/aceb7f</doi><orcidid>https://orcid.org/0000-0003-4531-1913</orcidid><orcidid>https://orcid.org/0000-0002-4516-5912</orcidid><orcidid>https://orcid.org/0000-0001-7851-5045</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0957-0233
ispartof Measurement science & technology, 2023-11, Vol.34 (11), p.115015
issn 0957-0233
1361-6501
language eng
recordid cdi_crossref_primary_10_1088_1361_6501_aceb7f
source Institute of Physics Journals
title Camera calibration approach using polarized light based on high-frequency component variance weighted entropy for pose measurement
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T10%3A16%3A05IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Camera%20calibration%20approach%20using%20polarized%20light%20based%20on%20high-frequency%20component%20variance%20weighted%20entropy%20for%20pose%20measurement&rft.jtitle=Measurement%20science%20&%20technology&rft.au=Zhang,%20Zimiao&rft.date=2023-11-01&rft.volume=34&rft.issue=11&rft.spage=115015&rft.pages=115015-&rft.issn=0957-0233&rft.eissn=1361-6501&rft_id=info:doi/10.1088/1361-6501/aceb7f&rft_dat=%3Ccrossref%3E10_1088_1361_6501_aceb7f%3C/crossref%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true