Analytical model and precise evaluation of multi-layer magnetic shielding performances considering ultra-weak magnetic properties
Regarding the vast difference between the design index and the actual performance of magnetic shielding devices, this paper proposes a novel method of using precise permeability under a specific weak magnetic field, aiming to improve the design accuracy of shielding performance. Firstly, the relativ...
Gespeichert in:
Veröffentlicht in: | Journal of physics. D, Applied physics Applied physics, 2024-09, Vol.57 (35) |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 35 |
container_start_page | |
container_title | Journal of physics. D, Applied physics |
container_volume | 57 |
creator | Xu, Xueping Wu, Weiwei Zhao, Zhenkai Liu, Wei Sun, Jinji |
description | Regarding the vast difference between the design index and the actual performance of magnetic shielding devices, this paper proposes a novel method of using precise permeability under a specific weak magnetic field, aiming to improve the design accuracy of shielding performance. Firstly, the relative permeability of the permalloy is measured under the applied magnetic field from the geomagnetic field down to 1 nT. Next, the precise shielding coefficient formulas of the single- and double-layer spherical shells are derived. For the double-layer spherical shell, the deviation of remanence between considering the ultra-weak magnetic properties and using the constant permeability is 24.3%. This clarifies the necessity of considering the ultra-weak magnetic properties in multi-layer structures. Then, a new accurate method of the shielding coefficient for the finite-length magnetic shielding cylinder is proposed, with a deviation of less than 5%. Finally, this method has been validated again by remanence measurement of the three-layer magnetic shielding cylinders. The deviation between simulation and experiment is 4.03% when considering the ultra-weak magnetic properties. While using the constant permeability, the deviation is as high as 19.31%. Therefore, considering the ultra weak magnetic properties in multi-layer structures can-significantly improve the accuracy of the performance evaluation. |
doi_str_mv | 10.1088/1361-6463/ad5211 |
format | Article |
fullrecord | <record><control><sourceid>iop_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1088_1361_6463_ad5211</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>dad5211</sourcerecordid><originalsourceid>FETCH-LOGICAL-c194t-8c322e9c3c35f1eaa987433c983f89801e6815bb120cb3cd7c1806bf0357554b3</originalsourceid><addsrcrecordid>eNp1kE1LxDAQhoMouK7ePebkybpJ07TpcVn8ggUveg5pMl2zpk1Jusoe_eemrOhFYWBg5n0G5kHokpIbSoRYUFbSrCxKtlCG55QeodnP6BjNCMnzjFV5dYrOYtwSQngp6Ax9Lnvl9qPVyuHOG3BY9QYPAbSNgOFduZ0are-xb3G3c6PNnNpDwJ3a9JAwHF8tOGP7DR4gtD50qtcQsfZ9tAbCtEhYUNkHqLdfbAg-5UcL8RydtMpFuPjuc_Ryd_u8esjWT_ePq-U607QuxkxoludQa6YZbykoVYuqYEzXgrWiFoRC-oc3Dc2Jbpg2laaClE1LGK84Lxo2R-RwVwcfY4BWDsF2KuwlJXJSKCdfcvIlDwoTcnVArB_k1u9CchWlkbySjKfihDA5mDYFr_8I_nv3C0Kbga0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Analytical model and precise evaluation of multi-layer magnetic shielding performances considering ultra-weak magnetic properties</title><source>Institute of Physics Journals</source><creator>Xu, Xueping ; Wu, Weiwei ; Zhao, Zhenkai ; Liu, Wei ; Sun, Jinji</creator><creatorcontrib>Xu, Xueping ; Wu, Weiwei ; Zhao, Zhenkai ; Liu, Wei ; Sun, Jinji</creatorcontrib><description>Regarding the vast difference between the design index and the actual performance of magnetic shielding devices, this paper proposes a novel method of using precise permeability under a specific weak magnetic field, aiming to improve the design accuracy of shielding performance. Firstly, the relative permeability of the permalloy is measured under the applied magnetic field from the geomagnetic field down to 1 nT. Next, the precise shielding coefficient formulas of the single- and double-layer spherical shells are derived. For the double-layer spherical shell, the deviation of remanence between considering the ultra-weak magnetic properties and using the constant permeability is 24.3%. This clarifies the necessity of considering the ultra-weak magnetic properties in multi-layer structures. Then, a new accurate method of the shielding coefficient for the finite-length magnetic shielding cylinder is proposed, with a deviation of less than 5%. Finally, this method has been validated again by remanence measurement of the three-layer magnetic shielding cylinders. The deviation between simulation and experiment is 4.03% when considering the ultra-weak magnetic properties. While using the constant permeability, the deviation is as high as 19.31%. Therefore, considering the ultra weak magnetic properties in multi-layer structures can-significantly improve the accuracy of the performance evaluation.</description><identifier>ISSN: 0022-3727</identifier><identifier>EISSN: 1361-6463</identifier><identifier>DOI: 10.1088/1361-6463/ad5211</identifier><identifier>CODEN: JPAPBE</identifier><language>eng</language><publisher>IOP Publishing</publisher><subject>analytical formula ; magnetic shielding cylinder ; permeability ; shielding coefficient ; ultra-weak magnetic field</subject><ispartof>Journal of physics. D, Applied physics, 2024-09, Vol.57 (35)</ispartof><rights>2024 IOP Publishing Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><orcidid>0000-0002-4720-0013</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/1361-6463/ad5211/pdf$$EPDF$$P50$$Giop$$H</linktopdf><link.rule.ids>314,780,784,27924,27925,53846,53893</link.rule.ids></links><search><creatorcontrib>Xu, Xueping</creatorcontrib><creatorcontrib>Wu, Weiwei</creatorcontrib><creatorcontrib>Zhao, Zhenkai</creatorcontrib><creatorcontrib>Liu, Wei</creatorcontrib><creatorcontrib>Sun, Jinji</creatorcontrib><title>Analytical model and precise evaluation of multi-layer magnetic shielding performances considering ultra-weak magnetic properties</title><title>Journal of physics. D, Applied physics</title><addtitle>JPhysD</addtitle><addtitle>J. Phys. D: Appl. Phys</addtitle><description>Regarding the vast difference between the design index and the actual performance of magnetic shielding devices, this paper proposes a novel method of using precise permeability under a specific weak magnetic field, aiming to improve the design accuracy of shielding performance. Firstly, the relative permeability of the permalloy is measured under the applied magnetic field from the geomagnetic field down to 1 nT. Next, the precise shielding coefficient formulas of the single- and double-layer spherical shells are derived. For the double-layer spherical shell, the deviation of remanence between considering the ultra-weak magnetic properties and using the constant permeability is 24.3%. This clarifies the necessity of considering the ultra-weak magnetic properties in multi-layer structures. Then, a new accurate method of the shielding coefficient for the finite-length magnetic shielding cylinder is proposed, with a deviation of less than 5%. Finally, this method has been validated again by remanence measurement of the three-layer magnetic shielding cylinders. The deviation between simulation and experiment is 4.03% when considering the ultra-weak magnetic properties. While using the constant permeability, the deviation is as high as 19.31%. Therefore, considering the ultra weak magnetic properties in multi-layer structures can-significantly improve the accuracy of the performance evaluation.</description><subject>analytical formula</subject><subject>magnetic shielding cylinder</subject><subject>permeability</subject><subject>shielding coefficient</subject><subject>ultra-weak magnetic field</subject><issn>0022-3727</issn><issn>1361-6463</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp1kE1LxDAQhoMouK7ePebkybpJ07TpcVn8ggUveg5pMl2zpk1Jusoe_eemrOhFYWBg5n0G5kHokpIbSoRYUFbSrCxKtlCG55QeodnP6BjNCMnzjFV5dYrOYtwSQngp6Ax9Lnvl9qPVyuHOG3BY9QYPAbSNgOFduZ0are-xb3G3c6PNnNpDwJ3a9JAwHF8tOGP7DR4gtD50qtcQsfZ9tAbCtEhYUNkHqLdfbAg-5UcL8RydtMpFuPjuc_Ryd_u8esjWT_ePq-U607QuxkxoludQa6YZbykoVYuqYEzXgrWiFoRC-oc3Dc2Jbpg2laaClE1LGK84Lxo2R-RwVwcfY4BWDsF2KuwlJXJSKCdfcvIlDwoTcnVArB_k1u9CchWlkbySjKfihDA5mDYFr_8I_nv3C0Kbga0</recordid><startdate>20240906</startdate><enddate>20240906</enddate><creator>Xu, Xueping</creator><creator>Wu, Weiwei</creator><creator>Zhao, Zhenkai</creator><creator>Liu, Wei</creator><creator>Sun, Jinji</creator><general>IOP Publishing</general><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0002-4720-0013</orcidid></search><sort><creationdate>20240906</creationdate><title>Analytical model and precise evaluation of multi-layer magnetic shielding performances considering ultra-weak magnetic properties</title><author>Xu, Xueping ; Wu, Weiwei ; Zhao, Zhenkai ; Liu, Wei ; Sun, Jinji</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c194t-8c322e9c3c35f1eaa987433c983f89801e6815bb120cb3cd7c1806bf0357554b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>analytical formula</topic><topic>magnetic shielding cylinder</topic><topic>permeability</topic><topic>shielding coefficient</topic><topic>ultra-weak magnetic field</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Xu, Xueping</creatorcontrib><creatorcontrib>Wu, Weiwei</creatorcontrib><creatorcontrib>Zhao, Zhenkai</creatorcontrib><creatorcontrib>Liu, Wei</creatorcontrib><creatorcontrib>Sun, Jinji</creatorcontrib><collection>CrossRef</collection><jtitle>Journal of physics. D, Applied physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Xu, Xueping</au><au>Wu, Weiwei</au><au>Zhao, Zhenkai</au><au>Liu, Wei</au><au>Sun, Jinji</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Analytical model and precise evaluation of multi-layer magnetic shielding performances considering ultra-weak magnetic properties</atitle><jtitle>Journal of physics. D, Applied physics</jtitle><stitle>JPhysD</stitle><addtitle>J. Phys. D: Appl. Phys</addtitle><date>2024-09-06</date><risdate>2024</risdate><volume>57</volume><issue>35</issue><issn>0022-3727</issn><eissn>1361-6463</eissn><coden>JPAPBE</coden><abstract>Regarding the vast difference between the design index and the actual performance of magnetic shielding devices, this paper proposes a novel method of using precise permeability under a specific weak magnetic field, aiming to improve the design accuracy of shielding performance. Firstly, the relative permeability of the permalloy is measured under the applied magnetic field from the geomagnetic field down to 1 nT. Next, the precise shielding coefficient formulas of the single- and double-layer spherical shells are derived. For the double-layer spherical shell, the deviation of remanence between considering the ultra-weak magnetic properties and using the constant permeability is 24.3%. This clarifies the necessity of considering the ultra-weak magnetic properties in multi-layer structures. Then, a new accurate method of the shielding coefficient for the finite-length magnetic shielding cylinder is proposed, with a deviation of less than 5%. Finally, this method has been validated again by remanence measurement of the three-layer magnetic shielding cylinders. The deviation between simulation and experiment is 4.03% when considering the ultra-weak magnetic properties. While using the constant permeability, the deviation is as high as 19.31%. Therefore, considering the ultra weak magnetic properties in multi-layer structures can-significantly improve the accuracy of the performance evaluation.</abstract><pub>IOP Publishing</pub><doi>10.1088/1361-6463/ad5211</doi><tpages>13</tpages><orcidid>https://orcid.org/0000-0002-4720-0013</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0022-3727 |
ispartof | Journal of physics. D, Applied physics, 2024-09, Vol.57 (35) |
issn | 0022-3727 1361-6463 |
language | eng |
recordid | cdi_crossref_primary_10_1088_1361_6463_ad5211 |
source | Institute of Physics Journals |
subjects | analytical formula magnetic shielding cylinder permeability shielding coefficient ultra-weak magnetic field |
title | Analytical model and precise evaluation of multi-layer magnetic shielding performances considering ultra-weak magnetic properties |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T13%3A53%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-iop_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Analytical%20model%20and%20precise%20evaluation%20of%20multi-layer%20magnetic%20shielding%20performances%20considering%20ultra-weak%20magnetic%20properties&rft.jtitle=Journal%20of%20physics.%20D,%20Applied%20physics&rft.au=Xu,%20Xueping&rft.date=2024-09-06&rft.volume=57&rft.issue=35&rft.issn=0022-3727&rft.eissn=1361-6463&rft.coden=JPAPBE&rft_id=info:doi/10.1088/1361-6463/ad5211&rft_dat=%3Ciop_cross%3Edad5211%3C/iop_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |