Microfluidic biochip platform sensitized by AgNPs for SERS based rapid detection of uric acid

Herein, a novel microfluidic-biochip enabled with surface enhanced Raman spectroscopy (SERS) as a readout has been demonstrated for uric acid (UA) detection as point-of care (POC) device. Three different biochip designs (D1, D2 and D3) containing pillars in a microchannel with different bending rati...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of micromechanics and microengineering 2022-09, Vol.32 (9), p.95007
Hauptverfasser: Mishra, Shubham, Goel, Sanket, Dwivedi, Prabhat K
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 9
container_start_page 95007
container_title Journal of micromechanics and microengineering
container_volume 32
creator Mishra, Shubham
Goel, Sanket
Dwivedi, Prabhat K
description Herein, a novel microfluidic-biochip enabled with surface enhanced Raman spectroscopy (SERS) as a readout has been demonstrated for uric acid (UA) detection as point-of care (POC) device. Three different biochip designs (D1, D2 and D3) containing pillars in a microchannel with different bending ratios were conceived and optimized for various mixing parameters using a multiphysics simulation tool. The microchannel, integrated with pillars, provide pressure perturbation, sharp corners, and variation in bending ratio improves phase shift and mixing index. Subsequently the microfluidic-biochips were fabricated by a combination of photo-and soft-lithography, and bonding strength between two Polydimethylsiloxane substrates were found stable up to a flow rate of 1.8 ml min −1 . Further to realize SERS activity in the microfluidic-biochip, cubic shape silver nanoparticles (AgNPs), with an average size ∼68 nm, were synthesized using poly-ol method. The SERS activity was optimized by simultaneously flowing AgNPs and crystal violet (CV) dye of 10 −6 M, with double inlet in the reservoir and highest sensitivity was achieved in the D3 biochip. Further, D3 biochip was employed for detection of extended concentrations of CV and UA. The enhancement factor limit of detection and relative standard deviation was found to be 2 × 10 7 , 8.9 × 10 −11 and 2.7% respectively for CV and 3.1 × 10 3 , 3.2 × 10 −7 and 2.9% respectively for UA. Interference of UA with lactic acid has been tested and device was able to detect signature peaks of both biomarkers up to 50 × 10 −9 M concentration. Thus, the developed microfluidic-biochip device has potential to be used in a POC setting for onsite detection of biomarkers.
doi_str_mv 10.1088/1361-6439/ac848c
format Article
fullrecord <record><control><sourceid>iop_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1088_1361_6439_ac848c</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>jmmac848c</sourcerecordid><originalsourceid>FETCH-LOGICAL-c210t-5fcf751bafa794ad4111b0365ddfc69ed1b56b2a6f34c6920cc3cc5161c2a7c93</originalsourceid><addsrcrecordid>eNp1kMtOwzAQRS0EEqWwZ-kPINQTJ06yrCpeUnmIwhJZ9tgGV20d2emifD2uitixGs2duVczh5BLYNfA2nYCXEAhKt5NFLZVi0dk9CcdkxHrBCuAQ3NKzlJaMgbQQjsiH48eY3CrrTceqfYBv3xP-5UaXIhrmuwm-cF_W0P1jk4_n14SzQO6uHldUK1S1qPqvaHGDhYHHzY0OLqNOUuhN-fkxKlVshe_dUzeb2_eZvfF_PnuYTadF1gCG4raoWtq0MqppquUqQBAMy5qYxyKzhrQtdClEo5XuS8ZIkesQQCWqsGOjwk75OZfUorWyT76tYo7CUzu8cg9C7lnIQ94suXqYPGhl8uwjZt84P_rPyheZ3M</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Microfluidic biochip platform sensitized by AgNPs for SERS based rapid detection of uric acid</title><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><creator>Mishra, Shubham ; Goel, Sanket ; Dwivedi, Prabhat K</creator><creatorcontrib>Mishra, Shubham ; Goel, Sanket ; Dwivedi, Prabhat K</creatorcontrib><description>Herein, a novel microfluidic-biochip enabled with surface enhanced Raman spectroscopy (SERS) as a readout has been demonstrated for uric acid (UA) detection as point-of care (POC) device. Three different biochip designs (D1, D2 and D3) containing pillars in a microchannel with different bending ratios were conceived and optimized for various mixing parameters using a multiphysics simulation tool. The microchannel, integrated with pillars, provide pressure perturbation, sharp corners, and variation in bending ratio improves phase shift and mixing index. Subsequently the microfluidic-biochips were fabricated by a combination of photo-and soft-lithography, and bonding strength between two Polydimethylsiloxane substrates were found stable up to a flow rate of 1.8 ml min −1 . Further to realize SERS activity in the microfluidic-biochip, cubic shape silver nanoparticles (AgNPs), with an average size ∼68 nm, were synthesized using poly-ol method. The SERS activity was optimized by simultaneously flowing AgNPs and crystal violet (CV) dye of 10 −6 M, with double inlet in the reservoir and highest sensitivity was achieved in the D3 biochip. Further, D3 biochip was employed for detection of extended concentrations of CV and UA. The enhancement factor limit of detection and relative standard deviation was found to be 2 × 10 7 , 8.9 × 10 −11 and 2.7% respectively for CV and 3.1 × 10 3 , 3.2 × 10 −7 and 2.9% respectively for UA. Interference of UA with lactic acid has been tested and device was able to detect signature peaks of both biomarkers up to 50 × 10 −9 M concentration. Thus, the developed microfluidic-biochip device has potential to be used in a POC setting for onsite detection of biomarkers.</description><identifier>ISSN: 0960-1317</identifier><identifier>EISSN: 1361-6439</identifier><identifier>DOI: 10.1088/1361-6439/ac848c</identifier><identifier>CODEN: JMMIEZ</identifier><language>eng</language><publisher>IOP Publishing</publisher><subject>microchannel ; microfluidic-biochip ; point-of-care diagnosis ; SERS ; silver nanoparticle (AgNp) ; uric acid</subject><ispartof>Journal of micromechanics and microengineering, 2022-09, Vol.32 (9), p.95007</ispartof><rights>2022 IOP Publishing Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c210t-5fcf751bafa794ad4111b0365ddfc69ed1b56b2a6f34c6920cc3cc5161c2a7c93</citedby><cites>FETCH-LOGICAL-c210t-5fcf751bafa794ad4111b0365ddfc69ed1b56b2a6f34c6920cc3cc5161c2a7c93</cites><orcidid>0000-0003-0248-1461 ; 0000-0002-9739-4178</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/1361-6439/ac848c/pdf$$EPDF$$P50$$Giop$$H</linktopdf><link.rule.ids>314,780,784,27923,27924,53845,53892</link.rule.ids></links><search><creatorcontrib>Mishra, Shubham</creatorcontrib><creatorcontrib>Goel, Sanket</creatorcontrib><creatorcontrib>Dwivedi, Prabhat K</creatorcontrib><title>Microfluidic biochip platform sensitized by AgNPs for SERS based rapid detection of uric acid</title><title>Journal of micromechanics and microengineering</title><addtitle>JMM</addtitle><addtitle>J. Micromech. Microeng</addtitle><description>Herein, a novel microfluidic-biochip enabled with surface enhanced Raman spectroscopy (SERS) as a readout has been demonstrated for uric acid (UA) detection as point-of care (POC) device. Three different biochip designs (D1, D2 and D3) containing pillars in a microchannel with different bending ratios were conceived and optimized for various mixing parameters using a multiphysics simulation tool. The microchannel, integrated with pillars, provide pressure perturbation, sharp corners, and variation in bending ratio improves phase shift and mixing index. Subsequently the microfluidic-biochips were fabricated by a combination of photo-and soft-lithography, and bonding strength between two Polydimethylsiloxane substrates were found stable up to a flow rate of 1.8 ml min −1 . Further to realize SERS activity in the microfluidic-biochip, cubic shape silver nanoparticles (AgNPs), with an average size ∼68 nm, were synthesized using poly-ol method. The SERS activity was optimized by simultaneously flowing AgNPs and crystal violet (CV) dye of 10 −6 M, with double inlet in the reservoir and highest sensitivity was achieved in the D3 biochip. Further, D3 biochip was employed for detection of extended concentrations of CV and UA. The enhancement factor limit of detection and relative standard deviation was found to be 2 × 10 7 , 8.9 × 10 −11 and 2.7% respectively for CV and 3.1 × 10 3 , 3.2 × 10 −7 and 2.9% respectively for UA. Interference of UA with lactic acid has been tested and device was able to detect signature peaks of both biomarkers up to 50 × 10 −9 M concentration. Thus, the developed microfluidic-biochip device has potential to be used in a POC setting for onsite detection of biomarkers.</description><subject>microchannel</subject><subject>microfluidic-biochip</subject><subject>point-of-care diagnosis</subject><subject>SERS</subject><subject>silver nanoparticle (AgNp)</subject><subject>uric acid</subject><issn>0960-1317</issn><issn>1361-6439</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNp1kMtOwzAQRS0EEqWwZ-kPINQTJ06yrCpeUnmIwhJZ9tgGV20d2emifD2uitixGs2duVczh5BLYNfA2nYCXEAhKt5NFLZVi0dk9CcdkxHrBCuAQ3NKzlJaMgbQQjsiH48eY3CrrTceqfYBv3xP-5UaXIhrmuwm-cF_W0P1jk4_n14SzQO6uHldUK1S1qPqvaHGDhYHHzY0OLqNOUuhN-fkxKlVshe_dUzeb2_eZvfF_PnuYTadF1gCG4raoWtq0MqppquUqQBAMy5qYxyKzhrQtdClEo5XuS8ZIkesQQCWqsGOjwk75OZfUorWyT76tYo7CUzu8cg9C7lnIQ94suXqYPGhl8uwjZt84P_rPyheZ3M</recordid><startdate>20220901</startdate><enddate>20220901</enddate><creator>Mishra, Shubham</creator><creator>Goel, Sanket</creator><creator>Dwivedi, Prabhat K</creator><general>IOP Publishing</general><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0003-0248-1461</orcidid><orcidid>https://orcid.org/0000-0002-9739-4178</orcidid></search><sort><creationdate>20220901</creationdate><title>Microfluidic biochip platform sensitized by AgNPs for SERS based rapid detection of uric acid</title><author>Mishra, Shubham ; Goel, Sanket ; Dwivedi, Prabhat K</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c210t-5fcf751bafa794ad4111b0365ddfc69ed1b56b2a6f34c6920cc3cc5161c2a7c93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>microchannel</topic><topic>microfluidic-biochip</topic><topic>point-of-care diagnosis</topic><topic>SERS</topic><topic>silver nanoparticle (AgNp)</topic><topic>uric acid</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mishra, Shubham</creatorcontrib><creatorcontrib>Goel, Sanket</creatorcontrib><creatorcontrib>Dwivedi, Prabhat K</creatorcontrib><collection>CrossRef</collection><jtitle>Journal of micromechanics and microengineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mishra, Shubham</au><au>Goel, Sanket</au><au>Dwivedi, Prabhat K</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Microfluidic biochip platform sensitized by AgNPs for SERS based rapid detection of uric acid</atitle><jtitle>Journal of micromechanics and microengineering</jtitle><stitle>JMM</stitle><addtitle>J. Micromech. Microeng</addtitle><date>2022-09-01</date><risdate>2022</risdate><volume>32</volume><issue>9</issue><spage>95007</spage><pages>95007-</pages><issn>0960-1317</issn><eissn>1361-6439</eissn><coden>JMMIEZ</coden><abstract>Herein, a novel microfluidic-biochip enabled with surface enhanced Raman spectroscopy (SERS) as a readout has been demonstrated for uric acid (UA) detection as point-of care (POC) device. Three different biochip designs (D1, D2 and D3) containing pillars in a microchannel with different bending ratios were conceived and optimized for various mixing parameters using a multiphysics simulation tool. The microchannel, integrated with pillars, provide pressure perturbation, sharp corners, and variation in bending ratio improves phase shift and mixing index. Subsequently the microfluidic-biochips were fabricated by a combination of photo-and soft-lithography, and bonding strength between two Polydimethylsiloxane substrates were found stable up to a flow rate of 1.8 ml min −1 . Further to realize SERS activity in the microfluidic-biochip, cubic shape silver nanoparticles (AgNPs), with an average size ∼68 nm, were synthesized using poly-ol method. The SERS activity was optimized by simultaneously flowing AgNPs and crystal violet (CV) dye of 10 −6 M, with double inlet in the reservoir and highest sensitivity was achieved in the D3 biochip. Further, D3 biochip was employed for detection of extended concentrations of CV and UA. The enhancement factor limit of detection and relative standard deviation was found to be 2 × 10 7 , 8.9 × 10 −11 and 2.7% respectively for CV and 3.1 × 10 3 , 3.2 × 10 −7 and 2.9% respectively for UA. Interference of UA with lactic acid has been tested and device was able to detect signature peaks of both biomarkers up to 50 × 10 −9 M concentration. Thus, the developed microfluidic-biochip device has potential to be used in a POC setting for onsite detection of biomarkers.</abstract><pub>IOP Publishing</pub><doi>10.1088/1361-6439/ac848c</doi><tpages>14</tpages><orcidid>https://orcid.org/0000-0003-0248-1461</orcidid><orcidid>https://orcid.org/0000-0002-9739-4178</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0960-1317
ispartof Journal of micromechanics and microengineering, 2022-09, Vol.32 (9), p.95007
issn 0960-1317
1361-6439
language eng
recordid cdi_crossref_primary_10_1088_1361_6439_ac848c
source IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link
subjects microchannel
microfluidic-biochip
point-of-care diagnosis
SERS
silver nanoparticle (AgNp)
uric acid
title Microfluidic biochip platform sensitized by AgNPs for SERS based rapid detection of uric acid
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-11T04%3A01%3A12IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-iop_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Microfluidic%20biochip%20platform%20sensitized%20by%20AgNPs%20for%20SERS%20based%20rapid%20detection%20of%20uric%20acid&rft.jtitle=Journal%20of%20micromechanics%20and%20microengineering&rft.au=Mishra,%20Shubham&rft.date=2022-09-01&rft.volume=32&rft.issue=9&rft.spage=95007&rft.pages=95007-&rft.issn=0960-1317&rft.eissn=1361-6439&rft.coden=JMMIEZ&rft_id=info:doi/10.1088/1361-6439/ac848c&rft_dat=%3Ciop_cross%3Ejmmac848c%3C/iop_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true