Vertebral arteries do not experience tensile force during manual cervical spine manipulation applied to human cadavers

The vertebral artery (VA) may be stretched and subsequently damaged during manual cervical spine manipulation. The objective of this study was to measure VA length changes that occur during cervical spine manipulation and to compare these to the VA failure length. Piezoelectric ultrasound crystals w...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of manual & manipulative therapy 2023-07, Vol.31 (4), p.261-269
Hauptverfasser: Gorrell, Lindsay M., Sawatsky, Andrew, Edwards, W Brent, Herzog, Walter
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 269
container_issue 4
container_start_page 261
container_title The Journal of manual & manipulative therapy
container_volume 31
creator Gorrell, Lindsay M.
Sawatsky, Andrew
Edwards, W Brent
Herzog, Walter
description The vertebral artery (VA) may be stretched and subsequently damaged during manual cervical spine manipulation. The objective of this study was to measure VA length changes that occur during cervical spine manipulation and to compare these to the VA failure length. Piezoelectric ultrasound crystals were implanted along the length of the VA (C1 to C7) and were used to measure length changes during cervical spine manipulation of seven un-embalmed, post-rigor human cadavers. Arteries were then excised, and elongation from arbitrary in-situ head/neck positions to first force (0.1 N) was measured. Following this, VA were stretched (8.33 mm/s) to mechanical failure. Failure was defined as the instance when VA elongation resulted in a decrease in force. From arbitrary in-situ head/neck positions, the greatest average VA length change during spinal manipulation was [mean (range)] 5.1% (1.1 to 15.1%). From arbitrary in-situ head/neck positions, arteries were elongated on average 33.5% (4.6 to 84.6%) prior to first force occurrence and 51.3% (16.3 to 105.1%) to failure. Average failure forces were 3.4 N (1.4 to 9.7 N). Measured in arbitrary in-situ head/neck positions, VA were slack. It appears that this slack must be taken up prior to VA experiencing tensile force. During cervical spine manipulations (using cervical spine extension and rotation), arterial length changes remained below that slack length, suggesting that VA elongated but were not stretched during the manipulation. However, in order to answer the question if cervical spine manipulation is safe from a mechanical perspective, the testing performed here needs to be repeated using a defined in-situ head/neck position and take into consideration other structures (e.g. carotid arteries).
doi_str_mv 10.1080/10669817.2022.2148048
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1080_10669817_2022_2148048</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2737115082</sourcerecordid><originalsourceid>FETCH-LOGICAL-c413t-2543e6e973fbb7963d923687c0a94b075ba44a54803ca44a3d00f64207d3f6d83</originalsourceid><addsrcrecordid>eNp9kE9v1DAQxS0EotstHwHkI5cs_hfbuYGqApUq9QK9Wo49AaPEDnaypd8eR7vlyGneeN6bkX8IvaXkQIkmHyiRstNUHRhh7MCo0EToF2jHiGCNpFq-RLvN02ymC3RZyi9CiBZEv0YXXHLNuFA7dHyAvECf7YhtFTlAwT7hmBYMf-atjw7wArGEEfCQcu38mkP8gScb1xpzkI_BVVHmEGF7DfM62iWkiO08jwE8XhL-udYJdtbbI-RyhV4Ndizw5lz36Pvnm2_XX5u7-y-315_uGicoXxrWCg4SOsWHvled5L5jXGrliO1ET1TbWyFsW__O3aa4J2SQghHl-SC95nv0_rR3zun3CmUxUygOxtFGSGsxTHFFaUsqjT1qT1aXUykZBjPnMNn8ZCgxG3LzjNxsyM0Zec29O59Y-wn8v9Qz42r4eDKEWPlN9jHl0ZvFPo0pD9lGF4rh_7_xF8mzkZ8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2737115082</pqid></control><display><type>article</type><title>Vertebral arteries do not experience tensile force during manual cervical spine manipulation applied to human cadavers</title><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>PubMed Central</source><creator>Gorrell, Lindsay M. ; Sawatsky, Andrew ; Edwards, W Brent ; Herzog, Walter</creator><creatorcontrib>Gorrell, Lindsay M. ; Sawatsky, Andrew ; Edwards, W Brent ; Herzog, Walter</creatorcontrib><description>The vertebral artery (VA) may be stretched and subsequently damaged during manual cervical spine manipulation. The objective of this study was to measure VA length changes that occur during cervical spine manipulation and to compare these to the VA failure length. Piezoelectric ultrasound crystals were implanted along the length of the VA (C1 to C7) and were used to measure length changes during cervical spine manipulation of seven un-embalmed, post-rigor human cadavers. Arteries were then excised, and elongation from arbitrary in-situ head/neck positions to first force (0.1 N) was measured. Following this, VA were stretched (8.33 mm/s) to mechanical failure. Failure was defined as the instance when VA elongation resulted in a decrease in force. From arbitrary in-situ head/neck positions, the greatest average VA length change during spinal manipulation was [mean (range)] 5.1% (1.1 to 15.1%). From arbitrary in-situ head/neck positions, arteries were elongated on average 33.5% (4.6 to 84.6%) prior to first force occurrence and 51.3% (16.3 to 105.1%) to failure. Average failure forces were 3.4 N (1.4 to 9.7 N). Measured in arbitrary in-situ head/neck positions, VA were slack. It appears that this slack must be taken up prior to VA experiencing tensile force. During cervical spine manipulations (using cervical spine extension and rotation), arterial length changes remained below that slack length, suggesting that VA elongated but were not stretched during the manipulation. However, in order to answer the question if cervical spine manipulation is safe from a mechanical perspective, the testing performed here needs to be repeated using a defined in-situ head/neck position and take into consideration other structures (e.g. carotid arteries).</description><identifier>ISSN: 1066-9817</identifier><identifier>EISSN: 2042-6186</identifier><identifier>DOI: 10.1080/10669817.2022.2148048</identifier><identifier>PMID: 36382347</identifier><language>eng</language><publisher>England: Taylor &amp; Francis</publisher><subject>Cadaver ; cerebrovascular accidents ; Cervical Vertebrae ; Humans ; Manipulation, Spinal - methods ; Neck ; Spinal biomechanics ; spinal manipulation ; stroke ; Vertebral Artery ; vertebral artery dissection</subject><ispartof>The Journal of manual &amp; manipulative therapy, 2023-07, Vol.31 (4), p.261-269</ispartof><rights>2022 Informa UK Limited, trading as Taylor &amp; Francis Group 2022</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c413t-2543e6e973fbb7963d923687c0a94b075ba44a54803ca44a3d00f64207d3f6d83</citedby><cites>FETCH-LOGICAL-c413t-2543e6e973fbb7963d923687c0a94b075ba44a54803ca44a3d00f64207d3f6d83</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,27905,27906</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/36382347$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Gorrell, Lindsay M.</creatorcontrib><creatorcontrib>Sawatsky, Andrew</creatorcontrib><creatorcontrib>Edwards, W Brent</creatorcontrib><creatorcontrib>Herzog, Walter</creatorcontrib><title>Vertebral arteries do not experience tensile force during manual cervical spine manipulation applied to human cadavers</title><title>The Journal of manual &amp; manipulative therapy</title><addtitle>J Man Manip Ther</addtitle><description>The vertebral artery (VA) may be stretched and subsequently damaged during manual cervical spine manipulation. The objective of this study was to measure VA length changes that occur during cervical spine manipulation and to compare these to the VA failure length. Piezoelectric ultrasound crystals were implanted along the length of the VA (C1 to C7) and were used to measure length changes during cervical spine manipulation of seven un-embalmed, post-rigor human cadavers. Arteries were then excised, and elongation from arbitrary in-situ head/neck positions to first force (0.1 N) was measured. Following this, VA were stretched (8.33 mm/s) to mechanical failure. Failure was defined as the instance when VA elongation resulted in a decrease in force. From arbitrary in-situ head/neck positions, the greatest average VA length change during spinal manipulation was [mean (range)] 5.1% (1.1 to 15.1%). From arbitrary in-situ head/neck positions, arteries were elongated on average 33.5% (4.6 to 84.6%) prior to first force occurrence and 51.3% (16.3 to 105.1%) to failure. Average failure forces were 3.4 N (1.4 to 9.7 N). Measured in arbitrary in-situ head/neck positions, VA were slack. It appears that this slack must be taken up prior to VA experiencing tensile force. During cervical spine manipulations (using cervical spine extension and rotation), arterial length changes remained below that slack length, suggesting that VA elongated but were not stretched during the manipulation. However, in order to answer the question if cervical spine manipulation is safe from a mechanical perspective, the testing performed here needs to be repeated using a defined in-situ head/neck position and take into consideration other structures (e.g. carotid arteries).</description><subject>Cadaver</subject><subject>cerebrovascular accidents</subject><subject>Cervical Vertebrae</subject><subject>Humans</subject><subject>Manipulation, Spinal - methods</subject><subject>Neck</subject><subject>Spinal biomechanics</subject><subject>spinal manipulation</subject><subject>stroke</subject><subject>Vertebral Artery</subject><subject>vertebral artery dissection</subject><issn>1066-9817</issn><issn>2042-6186</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kE9v1DAQxS0EotstHwHkI5cs_hfbuYGqApUq9QK9Wo49AaPEDnaypd8eR7vlyGneeN6bkX8IvaXkQIkmHyiRstNUHRhh7MCo0EToF2jHiGCNpFq-RLvN02ymC3RZyi9CiBZEv0YXXHLNuFA7dHyAvECf7YhtFTlAwT7hmBYMf-atjw7wArGEEfCQcu38mkP8gScb1xpzkI_BVVHmEGF7DfM62iWkiO08jwE8XhL-udYJdtbbI-RyhV4Ndizw5lz36Pvnm2_XX5u7-y-315_uGicoXxrWCg4SOsWHvled5L5jXGrliO1ET1TbWyFsW__O3aa4J2SQghHl-SC95nv0_rR3zun3CmUxUygOxtFGSGsxTHFFaUsqjT1qT1aXUykZBjPnMNn8ZCgxG3LzjNxsyM0Zec29O59Y-wn8v9Qz42r4eDKEWPlN9jHl0ZvFPo0pD9lGF4rh_7_xF8mzkZ8</recordid><startdate>20230704</startdate><enddate>20230704</enddate><creator>Gorrell, Lindsay M.</creator><creator>Sawatsky, Andrew</creator><creator>Edwards, W Brent</creator><creator>Herzog, Walter</creator><general>Taylor &amp; Francis</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20230704</creationdate><title>Vertebral arteries do not experience tensile force during manual cervical spine manipulation applied to human cadavers</title><author>Gorrell, Lindsay M. ; Sawatsky, Andrew ; Edwards, W Brent ; Herzog, Walter</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c413t-2543e6e973fbb7963d923687c0a94b075ba44a54803ca44a3d00f64207d3f6d83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Cadaver</topic><topic>cerebrovascular accidents</topic><topic>Cervical Vertebrae</topic><topic>Humans</topic><topic>Manipulation, Spinal - methods</topic><topic>Neck</topic><topic>Spinal biomechanics</topic><topic>spinal manipulation</topic><topic>stroke</topic><topic>Vertebral Artery</topic><topic>vertebral artery dissection</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gorrell, Lindsay M.</creatorcontrib><creatorcontrib>Sawatsky, Andrew</creatorcontrib><creatorcontrib>Edwards, W Brent</creatorcontrib><creatorcontrib>Herzog, Walter</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of manual &amp; manipulative therapy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gorrell, Lindsay M.</au><au>Sawatsky, Andrew</au><au>Edwards, W Brent</au><au>Herzog, Walter</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Vertebral arteries do not experience tensile force during manual cervical spine manipulation applied to human cadavers</atitle><jtitle>The Journal of manual &amp; manipulative therapy</jtitle><addtitle>J Man Manip Ther</addtitle><date>2023-07-04</date><risdate>2023</risdate><volume>31</volume><issue>4</issue><spage>261</spage><epage>269</epage><pages>261-269</pages><issn>1066-9817</issn><eissn>2042-6186</eissn><abstract>The vertebral artery (VA) may be stretched and subsequently damaged during manual cervical spine manipulation. The objective of this study was to measure VA length changes that occur during cervical spine manipulation and to compare these to the VA failure length. Piezoelectric ultrasound crystals were implanted along the length of the VA (C1 to C7) and were used to measure length changes during cervical spine manipulation of seven un-embalmed, post-rigor human cadavers. Arteries were then excised, and elongation from arbitrary in-situ head/neck positions to first force (0.1 N) was measured. Following this, VA were stretched (8.33 mm/s) to mechanical failure. Failure was defined as the instance when VA elongation resulted in a decrease in force. From arbitrary in-situ head/neck positions, the greatest average VA length change during spinal manipulation was [mean (range)] 5.1% (1.1 to 15.1%). From arbitrary in-situ head/neck positions, arteries were elongated on average 33.5% (4.6 to 84.6%) prior to first force occurrence and 51.3% (16.3 to 105.1%) to failure. Average failure forces were 3.4 N (1.4 to 9.7 N). Measured in arbitrary in-situ head/neck positions, VA were slack. It appears that this slack must be taken up prior to VA experiencing tensile force. During cervical spine manipulations (using cervical spine extension and rotation), arterial length changes remained below that slack length, suggesting that VA elongated but were not stretched during the manipulation. However, in order to answer the question if cervical spine manipulation is safe from a mechanical perspective, the testing performed here needs to be repeated using a defined in-situ head/neck position and take into consideration other structures (e.g. carotid arteries).</abstract><cop>England</cop><pub>Taylor &amp; Francis</pub><pmid>36382347</pmid><doi>10.1080/10669817.2022.2148048</doi><tpages>9</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1066-9817
ispartof The Journal of manual & manipulative therapy, 2023-07, Vol.31 (4), p.261-269
issn 1066-9817
2042-6186
language eng
recordid cdi_crossref_primary_10_1080_10669817_2022_2148048
source MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; PubMed Central
subjects Cadaver
cerebrovascular accidents
Cervical Vertebrae
Humans
Manipulation, Spinal - methods
Neck
Spinal biomechanics
spinal manipulation
stroke
Vertebral Artery
vertebral artery dissection
title Vertebral arteries do not experience tensile force during manual cervical spine manipulation applied to human cadavers
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-21T08%3A38%3A11IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Vertebral%20arteries%20do%20not%20experience%20tensile%20force%20during%20manual%20cervical%20spine%20manipulation%20applied%20to%20human%20cadavers&rft.jtitle=The%20Journal%20of%20manual%20&%20manipulative%20therapy&rft.au=Gorrell,%20Lindsay%20M.&rft.date=2023-07-04&rft.volume=31&rft.issue=4&rft.spage=261&rft.epage=269&rft.pages=261-269&rft.issn=1066-9817&rft.eissn=2042-6186&rft_id=info:doi/10.1080/10669817.2022.2148048&rft_dat=%3Cproquest_cross%3E2737115082%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2737115082&rft_id=info:pmid/36382347&rfr_iscdi=true