Multimodal optical ultrasound imaging: Real-time imaging under concurrent CT or MRI

Optical ultrasound (OpUS) imaging is an ultrasound modality that utilizes fiber-optic ultrasound sources and detectors to perform pulse-echo ultrasound imaging. These probes can be constructed entirely from glass optical fibers and plastic components, and as such, these devices have been predicted t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:APL photonics 2024-09, Vol.9 (9), p.096103-096103-11
Hauptverfasser: Watt, Fraser T., Muthurangu, Vivek, Steeden, Jennifer, Mackle, Eleanor C., Desjardins, Adrien E., Zhang, Edward Z., Beard, Paul C., Alles, Erwin J.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 096103-11
container_issue 9
container_start_page 096103
container_title APL photonics
container_volume 9
creator Watt, Fraser T.
Muthurangu, Vivek
Steeden, Jennifer
Mackle, Eleanor C.
Desjardins, Adrien E.
Zhang, Edward Z.
Beard, Paul C.
Alles, Erwin J.
description Optical ultrasound (OpUS) imaging is an ultrasound modality that utilizes fiber-optic ultrasound sources and detectors to perform pulse-echo ultrasound imaging. These probes can be constructed entirely from glass optical fibers and plastic components, and as such, these devices have been predicted to be compatible with computed tomography (CT) and magnetic resonance imaging (MRI), modalities that use intense electromagnetic fields for imaging. However, to date, this compatibility has not been demonstrated. In this work, a free-hand OpUS imaging system was developed specifically to investigate the compatibility of OpUS systems with CT and MRI imaging systems. The OpUS imaging platform discussed in this work was used to perform real-time OpUS imaging under (separately) concurrent CT and MRI. CT and MRI imaging of the OpUS probe was used to determine if the probe itself would induce artifacts in the CT and MRI imaging, and ultrasound resolution targets and background measurements were used to assess any impact of CT and MRI on the OpUS signal fidelity. These measurements demonstrate that there was negligible interaction between the OpUS system and both the CT and MRI systems, and to further demonstrate this capability, concurrent OpUS-CT and OpUS-MRI imaging was conducted of a tissue-mimicking phantom and a dynamic motion phantom. This work presents a comprehensive demonstration of an OpUS imaging system operating alongside CT and MRI, which opens up new applications of ultrasound imaging in electromagnetically challenging settings.
doi_str_mv 10.1063/5.0225554
format Article
fullrecord <record><control><sourceid>scitation_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1063_5_0225554</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_63b27646ed3f4c76a134cd15d5cc5334</doaj_id><sourcerecordid>app</sourcerecordid><originalsourceid>FETCH-LOGICAL-c255t-a945643515b6a04d99328a1eb2a3382a733f7b65f74525a2b0c8e300c432cc3e3</originalsourceid><addsrcrecordid>eNp9kM1LAzEQxYMoWGoP_ge5KmxNMvnY9SbFj0KLUOs5zGazZct2U7Lbg_-90Vbx5OkNb3483gwh15xNOdNwp6ZMCKWUPCMjASbPWKHN-Z_5kkz6fssY49rwQqoReVse2qHZhQpbGvZD45ImJ2IfDl1Fmx1umm5zT1ce2yyB_seiae0jdaFzhxh9N9DZmoZIl6v5Fbmose395KRj8v70uJ69ZIvX5_nsYZG5VHLIMBXQEhRXpUYmq6IAkSP3pUCAXKABqE2pVW2kEgpFyVzugTEnQTgHHsZkfsytAm7tPqZm8cMGbOy3EeLGYkwntd5qKIXRUvsKaumMRg7SVVxVyjkFIFPWzTHLxdD30de_eZzZr-daZU_PTeztke1dM-DQhO4f-BONwnd2</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Multimodal optical ultrasound imaging: Real-time imaging under concurrent CT or MRI</title><source>DOAJ Directory of Open Access Journals</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Watt, Fraser T. ; Muthurangu, Vivek ; Steeden, Jennifer ; Mackle, Eleanor C. ; Desjardins, Adrien E. ; Zhang, Edward Z. ; Beard, Paul C. ; Alles, Erwin J.</creator><creatorcontrib>Watt, Fraser T. ; Muthurangu, Vivek ; Steeden, Jennifer ; Mackle, Eleanor C. ; Desjardins, Adrien E. ; Zhang, Edward Z. ; Beard, Paul C. ; Alles, Erwin J.</creatorcontrib><description>Optical ultrasound (OpUS) imaging is an ultrasound modality that utilizes fiber-optic ultrasound sources and detectors to perform pulse-echo ultrasound imaging. These probes can be constructed entirely from glass optical fibers and plastic components, and as such, these devices have been predicted to be compatible with computed tomography (CT) and magnetic resonance imaging (MRI), modalities that use intense electromagnetic fields for imaging. However, to date, this compatibility has not been demonstrated. In this work, a free-hand OpUS imaging system was developed specifically to investigate the compatibility of OpUS systems with CT and MRI imaging systems. The OpUS imaging platform discussed in this work was used to perform real-time OpUS imaging under (separately) concurrent CT and MRI. CT and MRI imaging of the OpUS probe was used to determine if the probe itself would induce artifacts in the CT and MRI imaging, and ultrasound resolution targets and background measurements were used to assess any impact of CT and MRI on the OpUS signal fidelity. These measurements demonstrate that there was negligible interaction between the OpUS system and both the CT and MRI systems, and to further demonstrate this capability, concurrent OpUS-CT and OpUS-MRI imaging was conducted of a tissue-mimicking phantom and a dynamic motion phantom. This work presents a comprehensive demonstration of an OpUS imaging system operating alongside CT and MRI, which opens up new applications of ultrasound imaging in electromagnetically challenging settings.</description><identifier>ISSN: 2378-0967</identifier><identifier>EISSN: 2378-0967</identifier><identifier>DOI: 10.1063/5.0225554</identifier><identifier>CODEN: APPHD2</identifier><language>eng</language><publisher>AIP Publishing LLC</publisher><ispartof>APL photonics, 2024-09, Vol.9 (9), p.096103-096103-11</ispartof><rights>Author(s)</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c255t-a945643515b6a04d99328a1eb2a3382a733f7b65f74525a2b0c8e300c432cc3e3</cites><orcidid>0000-0002-9792-2022 ; 0000-0002-4292-6456 ; 0000-0002-8506-8623 ; 0000-0002-1932-1811 ; 0000-0002-1658-4421 ; 0000-0003-3339-3042</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,864,2102,27924,27925</link.rule.ids></links><search><creatorcontrib>Watt, Fraser T.</creatorcontrib><creatorcontrib>Muthurangu, Vivek</creatorcontrib><creatorcontrib>Steeden, Jennifer</creatorcontrib><creatorcontrib>Mackle, Eleanor C.</creatorcontrib><creatorcontrib>Desjardins, Adrien E.</creatorcontrib><creatorcontrib>Zhang, Edward Z.</creatorcontrib><creatorcontrib>Beard, Paul C.</creatorcontrib><creatorcontrib>Alles, Erwin J.</creatorcontrib><title>Multimodal optical ultrasound imaging: Real-time imaging under concurrent CT or MRI</title><title>APL photonics</title><description>Optical ultrasound (OpUS) imaging is an ultrasound modality that utilizes fiber-optic ultrasound sources and detectors to perform pulse-echo ultrasound imaging. These probes can be constructed entirely from glass optical fibers and plastic components, and as such, these devices have been predicted to be compatible with computed tomography (CT) and magnetic resonance imaging (MRI), modalities that use intense electromagnetic fields for imaging. However, to date, this compatibility has not been demonstrated. In this work, a free-hand OpUS imaging system was developed specifically to investigate the compatibility of OpUS systems with CT and MRI imaging systems. The OpUS imaging platform discussed in this work was used to perform real-time OpUS imaging under (separately) concurrent CT and MRI. CT and MRI imaging of the OpUS probe was used to determine if the probe itself would induce artifacts in the CT and MRI imaging, and ultrasound resolution targets and background measurements were used to assess any impact of CT and MRI on the OpUS signal fidelity. These measurements demonstrate that there was negligible interaction between the OpUS system and both the CT and MRI systems, and to further demonstrate this capability, concurrent OpUS-CT and OpUS-MRI imaging was conducted of a tissue-mimicking phantom and a dynamic motion phantom. This work presents a comprehensive demonstration of an OpUS imaging system operating alongside CT and MRI, which opens up new applications of ultrasound imaging in electromagnetically challenging settings.</description><issn>2378-0967</issn><issn>2378-0967</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNp9kM1LAzEQxYMoWGoP_ge5KmxNMvnY9SbFj0KLUOs5zGazZct2U7Lbg_-90Vbx5OkNb3483gwh15xNOdNwp6ZMCKWUPCMjASbPWKHN-Z_5kkz6fssY49rwQqoReVse2qHZhQpbGvZD45ImJ2IfDl1Fmx1umm5zT1ce2yyB_seiae0jdaFzhxh9N9DZmoZIl6v5Fbmose395KRj8v70uJ69ZIvX5_nsYZG5VHLIMBXQEhRXpUYmq6IAkSP3pUCAXKABqE2pVW2kEgpFyVzugTEnQTgHHsZkfsytAm7tPqZm8cMGbOy3EeLGYkwntd5qKIXRUvsKaumMRg7SVVxVyjkFIFPWzTHLxdD30de_eZzZr-daZU_PTeztke1dM-DQhO4f-BONwnd2</recordid><startdate>20240901</startdate><enddate>20240901</enddate><creator>Watt, Fraser T.</creator><creator>Muthurangu, Vivek</creator><creator>Steeden, Jennifer</creator><creator>Mackle, Eleanor C.</creator><creator>Desjardins, Adrien E.</creator><creator>Zhang, Edward Z.</creator><creator>Beard, Paul C.</creator><creator>Alles, Erwin J.</creator><general>AIP Publishing LLC</general><scope>AJDQP</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0002-9792-2022</orcidid><orcidid>https://orcid.org/0000-0002-4292-6456</orcidid><orcidid>https://orcid.org/0000-0002-8506-8623</orcidid><orcidid>https://orcid.org/0000-0002-1932-1811</orcidid><orcidid>https://orcid.org/0000-0002-1658-4421</orcidid><orcidid>https://orcid.org/0000-0003-3339-3042</orcidid></search><sort><creationdate>20240901</creationdate><title>Multimodal optical ultrasound imaging: Real-time imaging under concurrent CT or MRI</title><author>Watt, Fraser T. ; Muthurangu, Vivek ; Steeden, Jennifer ; Mackle, Eleanor C. ; Desjardins, Adrien E. ; Zhang, Edward Z. ; Beard, Paul C. ; Alles, Erwin J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c255t-a945643515b6a04d99328a1eb2a3382a733f7b65f74525a2b0c8e300c432cc3e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Watt, Fraser T.</creatorcontrib><creatorcontrib>Muthurangu, Vivek</creatorcontrib><creatorcontrib>Steeden, Jennifer</creatorcontrib><creatorcontrib>Mackle, Eleanor C.</creatorcontrib><creatorcontrib>Desjardins, Adrien E.</creatorcontrib><creatorcontrib>Zhang, Edward Z.</creatorcontrib><creatorcontrib>Beard, Paul C.</creatorcontrib><creatorcontrib>Alles, Erwin J.</creatorcontrib><collection>AIP Open Access Journals</collection><collection>CrossRef</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>APL photonics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Watt, Fraser T.</au><au>Muthurangu, Vivek</au><au>Steeden, Jennifer</au><au>Mackle, Eleanor C.</au><au>Desjardins, Adrien E.</au><au>Zhang, Edward Z.</au><au>Beard, Paul C.</au><au>Alles, Erwin J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Multimodal optical ultrasound imaging: Real-time imaging under concurrent CT or MRI</atitle><jtitle>APL photonics</jtitle><date>2024-09-01</date><risdate>2024</risdate><volume>9</volume><issue>9</issue><spage>096103</spage><epage>096103-11</epage><pages>096103-096103-11</pages><issn>2378-0967</issn><eissn>2378-0967</eissn><coden>APPHD2</coden><abstract>Optical ultrasound (OpUS) imaging is an ultrasound modality that utilizes fiber-optic ultrasound sources and detectors to perform pulse-echo ultrasound imaging. These probes can be constructed entirely from glass optical fibers and plastic components, and as such, these devices have been predicted to be compatible with computed tomography (CT) and magnetic resonance imaging (MRI), modalities that use intense electromagnetic fields for imaging. However, to date, this compatibility has not been demonstrated. In this work, a free-hand OpUS imaging system was developed specifically to investigate the compatibility of OpUS systems with CT and MRI imaging systems. The OpUS imaging platform discussed in this work was used to perform real-time OpUS imaging under (separately) concurrent CT and MRI. CT and MRI imaging of the OpUS probe was used to determine if the probe itself would induce artifacts in the CT and MRI imaging, and ultrasound resolution targets and background measurements were used to assess any impact of CT and MRI on the OpUS signal fidelity. These measurements demonstrate that there was negligible interaction between the OpUS system and both the CT and MRI systems, and to further demonstrate this capability, concurrent OpUS-CT and OpUS-MRI imaging was conducted of a tissue-mimicking phantom and a dynamic motion phantom. This work presents a comprehensive demonstration of an OpUS imaging system operating alongside CT and MRI, which opens up new applications of ultrasound imaging in electromagnetically challenging settings.</abstract><pub>AIP Publishing LLC</pub><doi>10.1063/5.0225554</doi><tpages>11</tpages><orcidid>https://orcid.org/0000-0002-9792-2022</orcidid><orcidid>https://orcid.org/0000-0002-4292-6456</orcidid><orcidid>https://orcid.org/0000-0002-8506-8623</orcidid><orcidid>https://orcid.org/0000-0002-1932-1811</orcidid><orcidid>https://orcid.org/0000-0002-1658-4421</orcidid><orcidid>https://orcid.org/0000-0003-3339-3042</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2378-0967
ispartof APL photonics, 2024-09, Vol.9 (9), p.096103-096103-11
issn 2378-0967
2378-0967
language eng
recordid cdi_crossref_primary_10_1063_5_0225554
source DOAJ Directory of Open Access Journals; EZB-FREE-00999 freely available EZB journals
title Multimodal optical ultrasound imaging: Real-time imaging under concurrent CT or MRI
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T18%3A03%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-scitation_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Multimodal%20optical%20ultrasound%20imaging:%20Real-time%20imaging%20under%20concurrent%20CT%20or%20MRI&rft.jtitle=APL%20photonics&rft.au=Watt,%20Fraser%20T.&rft.date=2024-09-01&rft.volume=9&rft.issue=9&rft.spage=096103&rft.epage=096103-11&rft.pages=096103-096103-11&rft.issn=2378-0967&rft.eissn=2378-0967&rft.coden=APPHD2&rft_id=info:doi/10.1063/5.0225554&rft_dat=%3Cscitation_cross%3Eapp%3C/scitation_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_doaj_id=oai_doaj_org_article_63b27646ed3f4c76a134cd15d5cc5334&rfr_iscdi=true