Constant current pulsed power supply for long pulse arc discharge positive hydrogen ion source
The simplest way to produce high density hydrogen plasmas is to form an arc between the arcing electrode and the plasma chamber (cathode). For arc-based hydrogen plasma generation, a pulsed power supply that delivers 2 ms-long constant current pulse has been developed. This pulsed power supply emplo...
Gespeichert in:
Veröffentlicht in: | Review of scientific instruments 2023-10, Vol.94 (10) |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 10 |
container_start_page | |
container_title | Review of scientific instruments |
container_volume | 94 |
creator | Motwani, Kapil Ghodke, Dharmraj V. Amban, Ajith Kochunarayanan, Murali Krishnan Ansari, M. S. Prasad, Vijendra |
description | The simplest way to produce high density hydrogen plasmas is to form an arc between the arcing electrode and the plasma chamber (cathode). For arc-based hydrogen plasma generation, a pulsed power supply that delivers 2 ms-long constant current pulse has been developed. This pulsed power supply employs a high frequency buck converter topology with a nonlinear filter inductor. This paper describes the development and testing of a constant current pulsed power supply that operates at 50 A and 550 V with a pulse width of 2 ms and a pulse repetition rate of 2 Hz. By changing the arc current, the arc impedance and the positive hydrogen ion current were also measured. The extraction of positive hydrogen ions was carried out using a three-electrode extraction design, which results in a current of 80 mA of positive hydrogen ions at an energy of 50 keV. |
doi_str_mv | 10.1063/5.0155386 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1063_5_0155386</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2874265025</sourcerecordid><originalsourceid>FETCH-LOGICAL-c285t-52c95bd0f8bba15d155a6ca80d58d6ce735da38aceace8e529a24170210f7e3e3</originalsourceid><addsrcrecordid>eNp90E1LAzEQBuAgCtbqwX8Q8KLC1nxssulRil9Q8KJXlzSZbbdskzXJKv33pqwnD4bAHOZJeGcQuqRkRonkd2JGqBBcySM0oUTNi0oyfowmhPCykFWpTtFZjFuSj6B0gj4W3sWkXcJmCAFy7YcugsW9_4aA49D33R43PuDOu_XYxDoYbNtoNjqsIcvYpvYL8GZvg1-Dw613OPohGDhHJ43OTy5-6xS9Pz68LZ6L5evTy-J-WRimRCoEM3OxsqRRq5WmwuYRtDRaESuUlQYqLqzmShvIV4Fgc81KWhFGSVMBBz5F1-O_ffCfA8RU73I-6DrtwA-xZqoqmRSEiUyv_tBtjupyuoPikjAlaVY3ozLBxxigqfvQ7nTY15TUh03Xov7ddLa3o42mTTrl6f_BP17jfpY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2873602861</pqid></control><display><type>article</type><title>Constant current pulsed power supply for long pulse arc discharge positive hydrogen ion source</title><source>AIP Journals Complete</source><source>Alma/SFX Local Collection</source><creator>Motwani, Kapil ; Ghodke, Dharmraj V. ; Amban, Ajith ; Kochunarayanan, Murali Krishnan ; Ansari, M. S. ; Prasad, Vijendra</creator><creatorcontrib>Motwani, Kapil ; Ghodke, Dharmraj V. ; Amban, Ajith ; Kochunarayanan, Murali Krishnan ; Ansari, M. S. ; Prasad, Vijendra</creatorcontrib><description>The simplest way to produce high density hydrogen plasmas is to form an arc between the arcing electrode and the plasma chamber (cathode). For arc-based hydrogen plasma generation, a pulsed power supply that delivers 2 ms-long constant current pulse has been developed. This pulsed power supply employs a high frequency buck converter topology with a nonlinear filter inductor. This paper describes the development and testing of a constant current pulsed power supply that operates at 50 A and 550 V with a pulse width of 2 ms and a pulse repetition rate of 2 Hz. By changing the arc current, the arc impedance and the positive hydrogen ion current were also measured. The extraction of positive hydrogen ions was carried out using a three-electrode extraction design, which results in a current of 80 mA of positive hydrogen ions at an energy of 50 keV.</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/5.0155386</identifier><identifier>CODEN: RSINAK</identifier><language>eng</language><publisher>Melville: American Institute of Physics</publisher><subject>Arc discharges ; Buck converters ; Electric arcs ; Electrodes ; Hydrogen ions ; Hydrogen plasma ; Inductors ; Ion currents ; Ion sources ; Nonlinear filters ; Pulse duration ; Pulse repetition rate ; Scientific apparatus & instruments ; Topology</subject><ispartof>Review of scientific instruments, 2023-10, Vol.94 (10)</ispartof><rights>Author(s)</rights><rights>2023 Author(s). Published under an exclusive license by AIP Publishing.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c285t-52c95bd0f8bba15d155a6ca80d58d6ce735da38aceace8e529a24170210f7e3e3</cites><orcidid>0000-0001-8270-9301 ; 0009-0001-9280-8941 ; 0000-0002-7180-5522 ; 0009-0008-0256-4535 ; 0009-0007-1923-2708</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/rsi/article-lookup/doi/10.1063/5.0155386$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>314,780,784,794,4512,27924,27925,76384</link.rule.ids></links><search><creatorcontrib>Motwani, Kapil</creatorcontrib><creatorcontrib>Ghodke, Dharmraj V.</creatorcontrib><creatorcontrib>Amban, Ajith</creatorcontrib><creatorcontrib>Kochunarayanan, Murali Krishnan</creatorcontrib><creatorcontrib>Ansari, M. S.</creatorcontrib><creatorcontrib>Prasad, Vijendra</creatorcontrib><title>Constant current pulsed power supply for long pulse arc discharge positive hydrogen ion source</title><title>Review of scientific instruments</title><description>The simplest way to produce high density hydrogen plasmas is to form an arc between the arcing electrode and the plasma chamber (cathode). For arc-based hydrogen plasma generation, a pulsed power supply that delivers 2 ms-long constant current pulse has been developed. This pulsed power supply employs a high frequency buck converter topology with a nonlinear filter inductor. This paper describes the development and testing of a constant current pulsed power supply that operates at 50 A and 550 V with a pulse width of 2 ms and a pulse repetition rate of 2 Hz. By changing the arc current, the arc impedance and the positive hydrogen ion current were also measured. The extraction of positive hydrogen ions was carried out using a three-electrode extraction design, which results in a current of 80 mA of positive hydrogen ions at an energy of 50 keV.</description><subject>Arc discharges</subject><subject>Buck converters</subject><subject>Electric arcs</subject><subject>Electrodes</subject><subject>Hydrogen ions</subject><subject>Hydrogen plasma</subject><subject>Inductors</subject><subject>Ion currents</subject><subject>Ion sources</subject><subject>Nonlinear filters</subject><subject>Pulse duration</subject><subject>Pulse repetition rate</subject><subject>Scientific apparatus & instruments</subject><subject>Topology</subject><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNp90E1LAzEQBuAgCtbqwX8Q8KLC1nxssulRil9Q8KJXlzSZbbdskzXJKv33pqwnD4bAHOZJeGcQuqRkRonkd2JGqBBcySM0oUTNi0oyfowmhPCykFWpTtFZjFuSj6B0gj4W3sWkXcJmCAFy7YcugsW9_4aA49D33R43PuDOu_XYxDoYbNtoNjqsIcvYpvYL8GZvg1-Dw613OPohGDhHJ43OTy5-6xS9Pz68LZ6L5evTy-J-WRimRCoEM3OxsqRRq5WmwuYRtDRaESuUlQYqLqzmShvIV4Fgc81KWhFGSVMBBz5F1-O_ffCfA8RU73I-6DrtwA-xZqoqmRSEiUyv_tBtjupyuoPikjAlaVY3ozLBxxigqfvQ7nTY15TUh03Xov7ddLa3o42mTTrl6f_BP17jfpY</recordid><startdate>20231001</startdate><enddate>20231001</enddate><creator>Motwani, Kapil</creator><creator>Ghodke, Dharmraj V.</creator><creator>Amban, Ajith</creator><creator>Kochunarayanan, Murali Krishnan</creator><creator>Ansari, M. S.</creator><creator>Prasad, Vijendra</creator><general>American Institute of Physics</general><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-8270-9301</orcidid><orcidid>https://orcid.org/0009-0001-9280-8941</orcidid><orcidid>https://orcid.org/0000-0002-7180-5522</orcidid><orcidid>https://orcid.org/0009-0008-0256-4535</orcidid><orcidid>https://orcid.org/0009-0007-1923-2708</orcidid></search><sort><creationdate>20231001</creationdate><title>Constant current pulsed power supply for long pulse arc discharge positive hydrogen ion source</title><author>Motwani, Kapil ; Ghodke, Dharmraj V. ; Amban, Ajith ; Kochunarayanan, Murali Krishnan ; Ansari, M. S. ; Prasad, Vijendra</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c285t-52c95bd0f8bba15d155a6ca80d58d6ce735da38aceace8e529a24170210f7e3e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Arc discharges</topic><topic>Buck converters</topic><topic>Electric arcs</topic><topic>Electrodes</topic><topic>Hydrogen ions</topic><topic>Hydrogen plasma</topic><topic>Inductors</topic><topic>Ion currents</topic><topic>Ion sources</topic><topic>Nonlinear filters</topic><topic>Pulse duration</topic><topic>Pulse repetition rate</topic><topic>Scientific apparatus & instruments</topic><topic>Topology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Motwani, Kapil</creatorcontrib><creatorcontrib>Ghodke, Dharmraj V.</creatorcontrib><creatorcontrib>Amban, Ajith</creatorcontrib><creatorcontrib>Kochunarayanan, Murali Krishnan</creatorcontrib><creatorcontrib>Ansari, M. S.</creatorcontrib><creatorcontrib>Prasad, Vijendra</creatorcontrib><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Review of scientific instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Motwani, Kapil</au><au>Ghodke, Dharmraj V.</au><au>Amban, Ajith</au><au>Kochunarayanan, Murali Krishnan</au><au>Ansari, M. S.</au><au>Prasad, Vijendra</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Constant current pulsed power supply for long pulse arc discharge positive hydrogen ion source</atitle><jtitle>Review of scientific instruments</jtitle><date>2023-10-01</date><risdate>2023</risdate><volume>94</volume><issue>10</issue><issn>0034-6748</issn><eissn>1089-7623</eissn><coden>RSINAK</coden><abstract>The simplest way to produce high density hydrogen plasmas is to form an arc between the arcing electrode and the plasma chamber (cathode). For arc-based hydrogen plasma generation, a pulsed power supply that delivers 2 ms-long constant current pulse has been developed. This pulsed power supply employs a high frequency buck converter topology with a nonlinear filter inductor. This paper describes the development and testing of a constant current pulsed power supply that operates at 50 A and 550 V with a pulse width of 2 ms and a pulse repetition rate of 2 Hz. By changing the arc current, the arc impedance and the positive hydrogen ion current were also measured. The extraction of positive hydrogen ions was carried out using a three-electrode extraction design, which results in a current of 80 mA of positive hydrogen ions at an energy of 50 keV.</abstract><cop>Melville</cop><pub>American Institute of Physics</pub><doi>10.1063/5.0155386</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0001-8270-9301</orcidid><orcidid>https://orcid.org/0009-0001-9280-8941</orcidid><orcidid>https://orcid.org/0000-0002-7180-5522</orcidid><orcidid>https://orcid.org/0009-0008-0256-4535</orcidid><orcidid>https://orcid.org/0009-0007-1923-2708</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0034-6748 |
ispartof | Review of scientific instruments, 2023-10, Vol.94 (10) |
issn | 0034-6748 1089-7623 |
language | eng |
recordid | cdi_crossref_primary_10_1063_5_0155386 |
source | AIP Journals Complete; Alma/SFX Local Collection |
subjects | Arc discharges Buck converters Electric arcs Electrodes Hydrogen ions Hydrogen plasma Inductors Ion currents Ion sources Nonlinear filters Pulse duration Pulse repetition rate Scientific apparatus & instruments Topology |
title | Constant current pulsed power supply for long pulse arc discharge positive hydrogen ion source |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T02%3A49%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Constant%20current%20pulsed%20power%20supply%20for%20long%20pulse%20arc%20discharge%20positive%20hydrogen%20ion%20source&rft.jtitle=Review%20of%20scientific%20instruments&rft.au=Motwani,%20Kapil&rft.date=2023-10-01&rft.volume=94&rft.issue=10&rft.issn=0034-6748&rft.eissn=1089-7623&rft.coden=RSINAK&rft_id=info:doi/10.1063/5.0155386&rft_dat=%3Cproquest_cross%3E2874265025%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2873602861&rft_id=info:pmid/&rfr_iscdi=true |