Constant current pulsed power supply for long pulse arc discharge positive hydrogen ion source

The simplest way to produce high density hydrogen plasmas is to form an arc between the arcing electrode and the plasma chamber (cathode). For arc-based hydrogen plasma generation, a pulsed power supply that delivers 2 ms-long constant current pulse has been developed. This pulsed power supply emplo...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Review of scientific instruments 2023-10, Vol.94 (10)
Hauptverfasser: Motwani, Kapil, Ghodke, Dharmraj V., Amban, Ajith, Kochunarayanan, Murali Krishnan, Ansari, M. S., Prasad, Vijendra
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 10
container_start_page
container_title Review of scientific instruments
container_volume 94
creator Motwani, Kapil
Ghodke, Dharmraj V.
Amban, Ajith
Kochunarayanan, Murali Krishnan
Ansari, M. S.
Prasad, Vijendra
description The simplest way to produce high density hydrogen plasmas is to form an arc between the arcing electrode and the plasma chamber (cathode). For arc-based hydrogen plasma generation, a pulsed power supply that delivers 2 ms-long constant current pulse has been developed. This pulsed power supply employs a high frequency buck converter topology with a nonlinear filter inductor. This paper describes the development and testing of a constant current pulsed power supply that operates at 50 A and 550 V with a pulse width of 2 ms and a pulse repetition rate of 2 Hz. By changing the arc current, the arc impedance and the positive hydrogen ion current were also measured. The extraction of positive hydrogen ions was carried out using a three-electrode extraction design, which results in a current of 80 mA of positive hydrogen ions at an energy of 50 keV.
doi_str_mv 10.1063/5.0155386
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1063_5_0155386</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2874265025</sourcerecordid><originalsourceid>FETCH-LOGICAL-c285t-52c95bd0f8bba15d155a6ca80d58d6ce735da38aceace8e529a24170210f7e3e3</originalsourceid><addsrcrecordid>eNp90E1LAzEQBuAgCtbqwX8Q8KLC1nxssulRil9Q8KJXlzSZbbdskzXJKv33pqwnD4bAHOZJeGcQuqRkRonkd2JGqBBcySM0oUTNi0oyfowmhPCykFWpTtFZjFuSj6B0gj4W3sWkXcJmCAFy7YcugsW9_4aA49D33R43PuDOu_XYxDoYbNtoNjqsIcvYpvYL8GZvg1-Dw613OPohGDhHJ43OTy5-6xS9Pz68LZ6L5evTy-J-WRimRCoEM3OxsqRRq5WmwuYRtDRaESuUlQYqLqzmShvIV4Fgc81KWhFGSVMBBz5F1-O_ffCfA8RU73I-6DrtwA-xZqoqmRSEiUyv_tBtjupyuoPikjAlaVY3ozLBxxigqfvQ7nTY15TUh03Xov7ddLa3o42mTTrl6f_BP17jfpY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2873602861</pqid></control><display><type>article</type><title>Constant current pulsed power supply for long pulse arc discharge positive hydrogen ion source</title><source>AIP Journals Complete</source><source>Alma/SFX Local Collection</source><creator>Motwani, Kapil ; Ghodke, Dharmraj V. ; Amban, Ajith ; Kochunarayanan, Murali Krishnan ; Ansari, M. S. ; Prasad, Vijendra</creator><creatorcontrib>Motwani, Kapil ; Ghodke, Dharmraj V. ; Amban, Ajith ; Kochunarayanan, Murali Krishnan ; Ansari, M. S. ; Prasad, Vijendra</creatorcontrib><description>The simplest way to produce high density hydrogen plasmas is to form an arc between the arcing electrode and the plasma chamber (cathode). For arc-based hydrogen plasma generation, a pulsed power supply that delivers 2 ms-long constant current pulse has been developed. This pulsed power supply employs a high frequency buck converter topology with a nonlinear filter inductor. This paper describes the development and testing of a constant current pulsed power supply that operates at 50 A and 550 V with a pulse width of 2 ms and a pulse repetition rate of 2 Hz. By changing the arc current, the arc impedance and the positive hydrogen ion current were also measured. The extraction of positive hydrogen ions was carried out using a three-electrode extraction design, which results in a current of 80 mA of positive hydrogen ions at an energy of 50 keV.</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/5.0155386</identifier><identifier>CODEN: RSINAK</identifier><language>eng</language><publisher>Melville: American Institute of Physics</publisher><subject>Arc discharges ; Buck converters ; Electric arcs ; Electrodes ; Hydrogen ions ; Hydrogen plasma ; Inductors ; Ion currents ; Ion sources ; Nonlinear filters ; Pulse duration ; Pulse repetition rate ; Scientific apparatus &amp; instruments ; Topology</subject><ispartof>Review of scientific instruments, 2023-10, Vol.94 (10)</ispartof><rights>Author(s)</rights><rights>2023 Author(s). Published under an exclusive license by AIP Publishing.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c285t-52c95bd0f8bba15d155a6ca80d58d6ce735da38aceace8e529a24170210f7e3e3</cites><orcidid>0000-0001-8270-9301 ; 0009-0001-9280-8941 ; 0000-0002-7180-5522 ; 0009-0008-0256-4535 ; 0009-0007-1923-2708</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/rsi/article-lookup/doi/10.1063/5.0155386$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>314,780,784,794,4512,27924,27925,76384</link.rule.ids></links><search><creatorcontrib>Motwani, Kapil</creatorcontrib><creatorcontrib>Ghodke, Dharmraj V.</creatorcontrib><creatorcontrib>Amban, Ajith</creatorcontrib><creatorcontrib>Kochunarayanan, Murali Krishnan</creatorcontrib><creatorcontrib>Ansari, M. S.</creatorcontrib><creatorcontrib>Prasad, Vijendra</creatorcontrib><title>Constant current pulsed power supply for long pulse arc discharge positive hydrogen ion source</title><title>Review of scientific instruments</title><description>The simplest way to produce high density hydrogen plasmas is to form an arc between the arcing electrode and the plasma chamber (cathode). For arc-based hydrogen plasma generation, a pulsed power supply that delivers 2 ms-long constant current pulse has been developed. This pulsed power supply employs a high frequency buck converter topology with a nonlinear filter inductor. This paper describes the development and testing of a constant current pulsed power supply that operates at 50 A and 550 V with a pulse width of 2 ms and a pulse repetition rate of 2 Hz. By changing the arc current, the arc impedance and the positive hydrogen ion current were also measured. The extraction of positive hydrogen ions was carried out using a three-electrode extraction design, which results in a current of 80 mA of positive hydrogen ions at an energy of 50 keV.</description><subject>Arc discharges</subject><subject>Buck converters</subject><subject>Electric arcs</subject><subject>Electrodes</subject><subject>Hydrogen ions</subject><subject>Hydrogen plasma</subject><subject>Inductors</subject><subject>Ion currents</subject><subject>Ion sources</subject><subject>Nonlinear filters</subject><subject>Pulse duration</subject><subject>Pulse repetition rate</subject><subject>Scientific apparatus &amp; instruments</subject><subject>Topology</subject><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNp90E1LAzEQBuAgCtbqwX8Q8KLC1nxssulRil9Q8KJXlzSZbbdskzXJKv33pqwnD4bAHOZJeGcQuqRkRonkd2JGqBBcySM0oUTNi0oyfowmhPCykFWpTtFZjFuSj6B0gj4W3sWkXcJmCAFy7YcugsW9_4aA49D33R43PuDOu_XYxDoYbNtoNjqsIcvYpvYL8GZvg1-Dw613OPohGDhHJ43OTy5-6xS9Pz68LZ6L5evTy-J-WRimRCoEM3OxsqRRq5WmwuYRtDRaESuUlQYqLqzmShvIV4Fgc81KWhFGSVMBBz5F1-O_ffCfA8RU73I-6DrtwA-xZqoqmRSEiUyv_tBtjupyuoPikjAlaVY3ozLBxxigqfvQ7nTY15TUh03Xov7ddLa3o42mTTrl6f_BP17jfpY</recordid><startdate>20231001</startdate><enddate>20231001</enddate><creator>Motwani, Kapil</creator><creator>Ghodke, Dharmraj V.</creator><creator>Amban, Ajith</creator><creator>Kochunarayanan, Murali Krishnan</creator><creator>Ansari, M. S.</creator><creator>Prasad, Vijendra</creator><general>American Institute of Physics</general><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-8270-9301</orcidid><orcidid>https://orcid.org/0009-0001-9280-8941</orcidid><orcidid>https://orcid.org/0000-0002-7180-5522</orcidid><orcidid>https://orcid.org/0009-0008-0256-4535</orcidid><orcidid>https://orcid.org/0009-0007-1923-2708</orcidid></search><sort><creationdate>20231001</creationdate><title>Constant current pulsed power supply for long pulse arc discharge positive hydrogen ion source</title><author>Motwani, Kapil ; Ghodke, Dharmraj V. ; Amban, Ajith ; Kochunarayanan, Murali Krishnan ; Ansari, M. S. ; Prasad, Vijendra</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c285t-52c95bd0f8bba15d155a6ca80d58d6ce735da38aceace8e529a24170210f7e3e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Arc discharges</topic><topic>Buck converters</topic><topic>Electric arcs</topic><topic>Electrodes</topic><topic>Hydrogen ions</topic><topic>Hydrogen plasma</topic><topic>Inductors</topic><topic>Ion currents</topic><topic>Ion sources</topic><topic>Nonlinear filters</topic><topic>Pulse duration</topic><topic>Pulse repetition rate</topic><topic>Scientific apparatus &amp; instruments</topic><topic>Topology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Motwani, Kapil</creatorcontrib><creatorcontrib>Ghodke, Dharmraj V.</creatorcontrib><creatorcontrib>Amban, Ajith</creatorcontrib><creatorcontrib>Kochunarayanan, Murali Krishnan</creatorcontrib><creatorcontrib>Ansari, M. S.</creatorcontrib><creatorcontrib>Prasad, Vijendra</creatorcontrib><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Review of scientific instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Motwani, Kapil</au><au>Ghodke, Dharmraj V.</au><au>Amban, Ajith</au><au>Kochunarayanan, Murali Krishnan</au><au>Ansari, M. S.</au><au>Prasad, Vijendra</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Constant current pulsed power supply for long pulse arc discharge positive hydrogen ion source</atitle><jtitle>Review of scientific instruments</jtitle><date>2023-10-01</date><risdate>2023</risdate><volume>94</volume><issue>10</issue><issn>0034-6748</issn><eissn>1089-7623</eissn><coden>RSINAK</coden><abstract>The simplest way to produce high density hydrogen plasmas is to form an arc between the arcing electrode and the plasma chamber (cathode). For arc-based hydrogen plasma generation, a pulsed power supply that delivers 2 ms-long constant current pulse has been developed. This pulsed power supply employs a high frequency buck converter topology with a nonlinear filter inductor. This paper describes the development and testing of a constant current pulsed power supply that operates at 50 A and 550 V with a pulse width of 2 ms and a pulse repetition rate of 2 Hz. By changing the arc current, the arc impedance and the positive hydrogen ion current were also measured. The extraction of positive hydrogen ions was carried out using a three-electrode extraction design, which results in a current of 80 mA of positive hydrogen ions at an energy of 50 keV.</abstract><cop>Melville</cop><pub>American Institute of Physics</pub><doi>10.1063/5.0155386</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0001-8270-9301</orcidid><orcidid>https://orcid.org/0009-0001-9280-8941</orcidid><orcidid>https://orcid.org/0000-0002-7180-5522</orcidid><orcidid>https://orcid.org/0009-0008-0256-4535</orcidid><orcidid>https://orcid.org/0009-0007-1923-2708</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0034-6748
ispartof Review of scientific instruments, 2023-10, Vol.94 (10)
issn 0034-6748
1089-7623
language eng
recordid cdi_crossref_primary_10_1063_5_0155386
source AIP Journals Complete; Alma/SFX Local Collection
subjects Arc discharges
Buck converters
Electric arcs
Electrodes
Hydrogen ions
Hydrogen plasma
Inductors
Ion currents
Ion sources
Nonlinear filters
Pulse duration
Pulse repetition rate
Scientific apparatus & instruments
Topology
title Constant current pulsed power supply for long pulse arc discharge positive hydrogen ion source
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T02%3A49%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Constant%20current%20pulsed%20power%20supply%20for%20long%20pulse%20arc%20discharge%20positive%20hydrogen%20ion%20source&rft.jtitle=Review%20of%20scientific%20instruments&rft.au=Motwani,%20Kapil&rft.date=2023-10-01&rft.volume=94&rft.issue=10&rft.issn=0034-6748&rft.eissn=1089-7623&rft.coden=RSINAK&rft_id=info:doi/10.1063/5.0155386&rft_dat=%3Cproquest_cross%3E2874265025%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2873602861&rft_id=info:pmid/&rfr_iscdi=true