Electrostatic contribution to hysteresis loop in piezoresponse force microscopy

In piezoresponse force microscopy (PFM), ideally, electromechanical strain is induced only by the converse piezoelectric effect. In reality, however, the obtained experimental PFM signal is a combination of many other factors. In particular, the concurrent electrostatic effect between the tip/cantil...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied physics letters 2019-04, Vol.114 (15)
Hauptverfasser: Qiao, Huimin, Seol, Daehee, Sun, Changhyo, Kim, Yunseok
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 15
container_start_page
container_title Applied physics letters
container_volume 114
creator Qiao, Huimin
Seol, Daehee
Sun, Changhyo
Kim, Yunseok
description In piezoresponse force microscopy (PFM), ideally, electromechanical strain is induced only by the converse piezoelectric effect. In reality, however, the obtained experimental PFM signal is a combination of many other factors. In particular, the concurrent electrostatic effect between the tip/cantilever and a sample surface can be significant because the electrostatic effect induced by surface potential is inevitable in some cases. However, most previous reports dealt with the extreme case of the electrostatic effect, such as the on-field state. That is, the contributions to the hysteresis loop of electrostatic effects from different sources have not yet been clearly understood. In the present work, we study the electrostatic effect on the hysteresis loop in relation to various measurement parameters. The results indicate that the PFM response is strongly affected by the electrostatic effect caused by external charge injection. This work can provide a guideline for determining the PFM response in a hysteresis loop.
doi_str_mv 10.1063/1.5090591
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1063_1_5090591</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2209753999</sourcerecordid><originalsourceid>FETCH-LOGICAL-c327t-881e74423fb64a581f9fe09ca0deda92f7c9ab728c591b0736dcd1f5d155adc93</originalsourceid><addsrcrecordid>eNp9kE1LAzEQhoMoWKsH_0HAk8LWfDSbzVFK_YBCL3oO2XxgSruJSVaov95dWvQgeBpmeHhn5gHgGqMZRjW9xzOGBGICn4AJRpxXFOPmFEwQQrSqBcPn4CLnzdAyQukErJdbq0sKuajiNdShK8m3ffGhgyXA930uNtnsM9yGEKHvYPT2KwyjGLpsoQtJW7jzeojQIe4vwZlT22yvjnUK3h6Xr4vnarV-elk8rCpNCS9V02DL53NCXVvPFWuwE84ioRUy1ihBHNdCtZw0enilRZzWRhvsmMGMKaMFnYKbQ25M4aO3uchN6FM3rJSEIMEZFWKkbg_UeF5O1smY_E6lvcRIjr4klkdfA3t3YLP2o4zQ_cCfIf2CMhr3H_w3-RtM43q2</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2209753999</pqid></control><display><type>article</type><title>Electrostatic contribution to hysteresis loop in piezoresponse force microscopy</title><source>AIP Journals Complete</source><source>Alma/SFX Local Collection</source><creator>Qiao, Huimin ; Seol, Daehee ; Sun, Changhyo ; Kim, Yunseok</creator><creatorcontrib>Qiao, Huimin ; Seol, Daehee ; Sun, Changhyo ; Kim, Yunseok</creatorcontrib><description>In piezoresponse force microscopy (PFM), ideally, electromechanical strain is induced only by the converse piezoelectric effect. In reality, however, the obtained experimental PFM signal is a combination of many other factors. In particular, the concurrent electrostatic effect between the tip/cantilever and a sample surface can be significant because the electrostatic effect induced by surface potential is inevitable in some cases. However, most previous reports dealt with the extreme case of the electrostatic effect, such as the on-field state. That is, the contributions to the hysteresis loop of electrostatic effects from different sources have not yet been clearly understood. In the present work, we study the electrostatic effect on the hysteresis loop in relation to various measurement parameters. The results indicate that the PFM response is strongly affected by the electrostatic effect caused by external charge injection. This work can provide a guideline for determining the PFM response in a hysteresis loop.</description><identifier>ISSN: 0003-6951</identifier><identifier>EISSN: 1077-3118</identifier><identifier>DOI: 10.1063/1.5090591</identifier><identifier>CODEN: APPLAB</identifier><language>eng</language><publisher>Melville: American Institute of Physics</publisher><subject>Applied physics ; Charge injection ; Hysteresis loops ; Microscopy ; Piezoelectricity</subject><ispartof>Applied physics letters, 2019-04, Vol.114 (15)</ispartof><rights>Author(s)</rights><rights>2019 Author(s). Published under license by AIP Publishing.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c327t-881e74423fb64a581f9fe09ca0deda92f7c9ab728c591b0736dcd1f5d155adc93</citedby><cites>FETCH-LOGICAL-c327t-881e74423fb64a581f9fe09ca0deda92f7c9ab728c591b0736dcd1f5d155adc93</cites><orcidid>0000-0003-1794-1248</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/apl/article-lookup/doi/10.1063/1.5090591$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>314,778,782,792,4500,27911,27912,76139</link.rule.ids></links><search><creatorcontrib>Qiao, Huimin</creatorcontrib><creatorcontrib>Seol, Daehee</creatorcontrib><creatorcontrib>Sun, Changhyo</creatorcontrib><creatorcontrib>Kim, Yunseok</creatorcontrib><title>Electrostatic contribution to hysteresis loop in piezoresponse force microscopy</title><title>Applied physics letters</title><description>In piezoresponse force microscopy (PFM), ideally, electromechanical strain is induced only by the converse piezoelectric effect. In reality, however, the obtained experimental PFM signal is a combination of many other factors. In particular, the concurrent electrostatic effect between the tip/cantilever and a sample surface can be significant because the electrostatic effect induced by surface potential is inevitable in some cases. However, most previous reports dealt with the extreme case of the electrostatic effect, such as the on-field state. That is, the contributions to the hysteresis loop of electrostatic effects from different sources have not yet been clearly understood. In the present work, we study the electrostatic effect on the hysteresis loop in relation to various measurement parameters. The results indicate that the PFM response is strongly affected by the electrostatic effect caused by external charge injection. This work can provide a guideline for determining the PFM response in a hysteresis loop.</description><subject>Applied physics</subject><subject>Charge injection</subject><subject>Hysteresis loops</subject><subject>Microscopy</subject><subject>Piezoelectricity</subject><issn>0003-6951</issn><issn>1077-3118</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNp9kE1LAzEQhoMoWKsH_0HAk8LWfDSbzVFK_YBCL3oO2XxgSruJSVaov95dWvQgeBpmeHhn5gHgGqMZRjW9xzOGBGICn4AJRpxXFOPmFEwQQrSqBcPn4CLnzdAyQukErJdbq0sKuajiNdShK8m3ffGhgyXA930uNtnsM9yGEKHvYPT2KwyjGLpsoQtJW7jzeojQIe4vwZlT22yvjnUK3h6Xr4vnarV-elk8rCpNCS9V02DL53NCXVvPFWuwE84ioRUy1ihBHNdCtZw0enilRZzWRhvsmMGMKaMFnYKbQ25M4aO3uchN6FM3rJSEIMEZFWKkbg_UeF5O1smY_E6lvcRIjr4klkdfA3t3YLP2o4zQ_cCfIf2CMhr3H_w3-RtM43q2</recordid><startdate>20190415</startdate><enddate>20190415</enddate><creator>Qiao, Huimin</creator><creator>Seol, Daehee</creator><creator>Sun, Changhyo</creator><creator>Kim, Yunseok</creator><general>American Institute of Physics</general><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope><orcidid>https://orcid.org/0000-0003-1794-1248</orcidid></search><sort><creationdate>20190415</creationdate><title>Electrostatic contribution to hysteresis loop in piezoresponse force microscopy</title><author>Qiao, Huimin ; Seol, Daehee ; Sun, Changhyo ; Kim, Yunseok</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c327t-881e74423fb64a581f9fe09ca0deda92f7c9ab728c591b0736dcd1f5d155adc93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Applied physics</topic><topic>Charge injection</topic><topic>Hysteresis loops</topic><topic>Microscopy</topic><topic>Piezoelectricity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Qiao, Huimin</creatorcontrib><creatorcontrib>Seol, Daehee</creatorcontrib><creatorcontrib>Sun, Changhyo</creatorcontrib><creatorcontrib>Kim, Yunseok</creatorcontrib><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Applied physics letters</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Qiao, Huimin</au><au>Seol, Daehee</au><au>Sun, Changhyo</au><au>Kim, Yunseok</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Electrostatic contribution to hysteresis loop in piezoresponse force microscopy</atitle><jtitle>Applied physics letters</jtitle><date>2019-04-15</date><risdate>2019</risdate><volume>114</volume><issue>15</issue><issn>0003-6951</issn><eissn>1077-3118</eissn><coden>APPLAB</coden><abstract>In piezoresponse force microscopy (PFM), ideally, electromechanical strain is induced only by the converse piezoelectric effect. In reality, however, the obtained experimental PFM signal is a combination of many other factors. In particular, the concurrent electrostatic effect between the tip/cantilever and a sample surface can be significant because the electrostatic effect induced by surface potential is inevitable in some cases. However, most previous reports dealt with the extreme case of the electrostatic effect, such as the on-field state. That is, the contributions to the hysteresis loop of electrostatic effects from different sources have not yet been clearly understood. In the present work, we study the electrostatic effect on the hysteresis loop in relation to various measurement parameters. The results indicate that the PFM response is strongly affected by the electrostatic effect caused by external charge injection. This work can provide a guideline for determining the PFM response in a hysteresis loop.</abstract><cop>Melville</cop><pub>American Institute of Physics</pub><doi>10.1063/1.5090591</doi><tpages>5</tpages><orcidid>https://orcid.org/0000-0003-1794-1248</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0003-6951
ispartof Applied physics letters, 2019-04, Vol.114 (15)
issn 0003-6951
1077-3118
language eng
recordid cdi_crossref_primary_10_1063_1_5090591
source AIP Journals Complete; Alma/SFX Local Collection
subjects Applied physics
Charge injection
Hysteresis loops
Microscopy
Piezoelectricity
title Electrostatic contribution to hysteresis loop in piezoresponse force microscopy
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-16T05%3A48%3A20IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Electrostatic%20contribution%20to%20hysteresis%20loop%20in%20piezoresponse%20force%20microscopy&rft.jtitle=Applied%20physics%20letters&rft.au=Qiao,%20Huimin&rft.date=2019-04-15&rft.volume=114&rft.issue=15&rft.issn=0003-6951&rft.eissn=1077-3118&rft.coden=APPLAB&rft_id=info:doi/10.1063/1.5090591&rft_dat=%3Cproquest_cross%3E2209753999%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2209753999&rft_id=info:pmid/&rfr_iscdi=true