Intensity of Raman modes as a temperature gauge in fluid hydrogen and deuterium

The Raman spectra of liquid H 2 ( D 2 ) have been collected in diamond anvil cell as a function of temperature at 3 GPa covering the range from 80 to ∼ 1000 K. Temperatures were measured using two independent methods: by thermocouple and from the relative intensity ratio of the present Raman modes....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of applied physics 2019-01, Vol.125 (2)
Hauptverfasser: Peña-Alvarez, Miriam, Dalladay-Simpson, Philip, Liu, Xiao-Di, Afonina, Veronika, Zhang, Hui-Chao, Howie, Ross T., Gregoryanz, Eugene
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 2
container_start_page
container_title Journal of applied physics
container_volume 125
creator Peña-Alvarez, Miriam
Dalladay-Simpson, Philip
Liu, Xiao-Di
Afonina, Veronika
Zhang, Hui-Chao
Howie, Ross T.
Gregoryanz, Eugene
description The Raman spectra of liquid H 2 ( D 2 ) have been collected in diamond anvil cell as a function of temperature at 3 GPa covering the range from 80 to ∼ 1000 K. Temperatures were measured using two independent methods: by thermocouple and from the relative intensity ratio of the present Raman modes. We find excellent agreement between the two methods in the low temperature regime (80 to 400 K) but observe discrepancies between these approaches at temperatures above 400 K. We attribute that the temperature difference between the two methods arises primarily from the proximity of the thermocouple relative to the heating elements and sample. Although not always available in high-pressure experiments, the metrology based on in situ physical properties of the sample is absolute and more reliable than the secondary gauges based on external devices.
doi_str_mv 10.1063/1.5070113
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1063_1_5070113</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2165523088</sourcerecordid><originalsourceid>FETCH-LOGICAL-c362t-7a28cb19bd54eaa34f54c25fcdc2ae2f0bef87e5a894f3fd3b777df4484c42e83</originalsourceid><addsrcrecordid>eNp90EtLAzEUBeAgCtbqwn8QcKUwNc9OZinFR6FQEF2HTHJTp3QyNckI_fdOadGFIFy4m49z4CB0TcmEkim_pxNJSkIpP0EjSlRVlFKSUzQihNFCVWV1ji5SWpOBKF6N0HIeMoTU5B3uPH41rQm47RwkbIbDGdotRJP7CHhl-hXgJmC_6RuHP3YudisI2ASHHfQZYtO3l-jMm02Cq-Mfo_enx7fZS7FYPs9nD4vC8inLRWmYsjWtaicFGMOFl8Iy6a2zzADzpAavSpBGVcJz73hdlqXzQihhBQPFx-jmkLuN3WcPKet118cwVGpGp1IyTtRe3R6UjV1KEbzexqY1cacp0fu9NNXHvQZ7d7DJNtnkpgs_-KuLv1Bvnf8P_03-Bp0oeVo</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2165523088</pqid></control><display><type>article</type><title>Intensity of Raman modes as a temperature gauge in fluid hydrogen and deuterium</title><source>AIP Journals Complete</source><source>Alma/SFX Local Collection</source><creator>Peña-Alvarez, Miriam ; Dalladay-Simpson, Philip ; Liu, Xiao-Di ; Afonina, Veronika ; Zhang, Hui-Chao ; Howie, Ross T. ; Gregoryanz, Eugene</creator><creatorcontrib>Peña-Alvarez, Miriam ; Dalladay-Simpson, Philip ; Liu, Xiao-Di ; Afonina, Veronika ; Zhang, Hui-Chao ; Howie, Ross T. ; Gregoryanz, Eugene</creatorcontrib><description>The Raman spectra of liquid H 2 ( D 2 ) have been collected in diamond anvil cell as a function of temperature at 3 GPa covering the range from 80 to ∼ 1000 K. Temperatures were measured using two independent methods: by thermocouple and from the relative intensity ratio of the present Raman modes. We find excellent agreement between the two methods in the low temperature regime (80 to 400 K) but observe discrepancies between these approaches at temperatures above 400 K. We attribute that the temperature difference between the two methods arises primarily from the proximity of the thermocouple relative to the heating elements and sample. Although not always available in high-pressure experiments, the metrology based on in situ physical properties of the sample is absolute and more reliable than the secondary gauges based on external devices.</description><identifier>ISSN: 0021-8979</identifier><identifier>EISSN: 1089-7550</identifier><identifier>DOI: 10.1063/1.5070113</identifier><identifier>CODEN: JAPIAU</identifier><language>eng</language><publisher>Melville: American Institute of Physics</publisher><subject>Applied physics ; Deuterium ; Diamond anvil cells ; Diamonds ; Gauges ; Physical properties ; Raman spectra ; Temperature ; Temperature gradients ; Thermocouples</subject><ispartof>Journal of applied physics, 2019-01, Vol.125 (2)</ispartof><rights>Author(s)</rights><rights>2018 Author(s). Published under license by AIP Publishing.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c362t-7a28cb19bd54eaa34f54c25fcdc2ae2f0bef87e5a894f3fd3b777df4484c42e83</citedby><cites>FETCH-LOGICAL-c362t-7a28cb19bd54eaa34f54c25fcdc2ae2f0bef87e5a894f3fd3b777df4484c42e83</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/jap/article-lookup/doi/10.1063/1.5070113$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>314,780,784,794,4512,27924,27925,76384</link.rule.ids></links><search><creatorcontrib>Peña-Alvarez, Miriam</creatorcontrib><creatorcontrib>Dalladay-Simpson, Philip</creatorcontrib><creatorcontrib>Liu, Xiao-Di</creatorcontrib><creatorcontrib>Afonina, Veronika</creatorcontrib><creatorcontrib>Zhang, Hui-Chao</creatorcontrib><creatorcontrib>Howie, Ross T.</creatorcontrib><creatorcontrib>Gregoryanz, Eugene</creatorcontrib><title>Intensity of Raman modes as a temperature gauge in fluid hydrogen and deuterium</title><title>Journal of applied physics</title><description>The Raman spectra of liquid H 2 ( D 2 ) have been collected in diamond anvil cell as a function of temperature at 3 GPa covering the range from 80 to ∼ 1000 K. Temperatures were measured using two independent methods: by thermocouple and from the relative intensity ratio of the present Raman modes. We find excellent agreement between the two methods in the low temperature regime (80 to 400 K) but observe discrepancies between these approaches at temperatures above 400 K. We attribute that the temperature difference between the two methods arises primarily from the proximity of the thermocouple relative to the heating elements and sample. Although not always available in high-pressure experiments, the metrology based on in situ physical properties of the sample is absolute and more reliable than the secondary gauges based on external devices.</description><subject>Applied physics</subject><subject>Deuterium</subject><subject>Diamond anvil cells</subject><subject>Diamonds</subject><subject>Gauges</subject><subject>Physical properties</subject><subject>Raman spectra</subject><subject>Temperature</subject><subject>Temperature gradients</subject><subject>Thermocouples</subject><issn>0021-8979</issn><issn>1089-7550</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNp90EtLAzEUBeAgCtbqwn8QcKUwNc9OZinFR6FQEF2HTHJTp3QyNckI_fdOadGFIFy4m49z4CB0TcmEkim_pxNJSkIpP0EjSlRVlFKSUzQihNFCVWV1ji5SWpOBKF6N0HIeMoTU5B3uPH41rQm47RwkbIbDGdotRJP7CHhl-hXgJmC_6RuHP3YudisI2ASHHfQZYtO3l-jMm02Cq-Mfo_enx7fZS7FYPs9nD4vC8inLRWmYsjWtaicFGMOFl8Iy6a2zzADzpAavSpBGVcJz73hdlqXzQihhBQPFx-jmkLuN3WcPKet118cwVGpGp1IyTtRe3R6UjV1KEbzexqY1cacp0fu9NNXHvQZ7d7DJNtnkpgs_-KuLv1Bvnf8P_03-Bp0oeVo</recordid><startdate>20190114</startdate><enddate>20190114</enddate><creator>Peña-Alvarez, Miriam</creator><creator>Dalladay-Simpson, Philip</creator><creator>Liu, Xiao-Di</creator><creator>Afonina, Veronika</creator><creator>Zhang, Hui-Chao</creator><creator>Howie, Ross T.</creator><creator>Gregoryanz, Eugene</creator><general>American Institute of Physics</general><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20190114</creationdate><title>Intensity of Raman modes as a temperature gauge in fluid hydrogen and deuterium</title><author>Peña-Alvarez, Miriam ; Dalladay-Simpson, Philip ; Liu, Xiao-Di ; Afonina, Veronika ; Zhang, Hui-Chao ; Howie, Ross T. ; Gregoryanz, Eugene</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c362t-7a28cb19bd54eaa34f54c25fcdc2ae2f0bef87e5a894f3fd3b777df4484c42e83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Applied physics</topic><topic>Deuterium</topic><topic>Diamond anvil cells</topic><topic>Diamonds</topic><topic>Gauges</topic><topic>Physical properties</topic><topic>Raman spectra</topic><topic>Temperature</topic><topic>Temperature gradients</topic><topic>Thermocouples</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Peña-Alvarez, Miriam</creatorcontrib><creatorcontrib>Dalladay-Simpson, Philip</creatorcontrib><creatorcontrib>Liu, Xiao-Di</creatorcontrib><creatorcontrib>Afonina, Veronika</creatorcontrib><creatorcontrib>Zhang, Hui-Chao</creatorcontrib><creatorcontrib>Howie, Ross T.</creatorcontrib><creatorcontrib>Gregoryanz, Eugene</creatorcontrib><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Journal of applied physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Peña-Alvarez, Miriam</au><au>Dalladay-Simpson, Philip</au><au>Liu, Xiao-Di</au><au>Afonina, Veronika</au><au>Zhang, Hui-Chao</au><au>Howie, Ross T.</au><au>Gregoryanz, Eugene</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Intensity of Raman modes as a temperature gauge in fluid hydrogen and deuterium</atitle><jtitle>Journal of applied physics</jtitle><date>2019-01-14</date><risdate>2019</risdate><volume>125</volume><issue>2</issue><issn>0021-8979</issn><eissn>1089-7550</eissn><coden>JAPIAU</coden><abstract>The Raman spectra of liquid H 2 ( D 2 ) have been collected in diamond anvil cell as a function of temperature at 3 GPa covering the range from 80 to ∼ 1000 K. Temperatures were measured using two independent methods: by thermocouple and from the relative intensity ratio of the present Raman modes. We find excellent agreement between the two methods in the low temperature regime (80 to 400 K) but observe discrepancies between these approaches at temperatures above 400 K. We attribute that the temperature difference between the two methods arises primarily from the proximity of the thermocouple relative to the heating elements and sample. Although not always available in high-pressure experiments, the metrology based on in situ physical properties of the sample is absolute and more reliable than the secondary gauges based on external devices.</abstract><cop>Melville</cop><pub>American Institute of Physics</pub><doi>10.1063/1.5070113</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0021-8979
ispartof Journal of applied physics, 2019-01, Vol.125 (2)
issn 0021-8979
1089-7550
language eng
recordid cdi_crossref_primary_10_1063_1_5070113
source AIP Journals Complete; Alma/SFX Local Collection
subjects Applied physics
Deuterium
Diamond anvil cells
Diamonds
Gauges
Physical properties
Raman spectra
Temperature
Temperature gradients
Thermocouples
title Intensity of Raman modes as a temperature gauge in fluid hydrogen and deuterium
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T21%3A52%3A10IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Intensity%20of%20Raman%20modes%20as%20a%20temperature%20gauge%20in%20fluid%20hydrogen%20and%20deuterium&rft.jtitle=Journal%20of%20applied%20physics&rft.au=Pe%C3%B1a-Alvarez,%20Miriam&rft.date=2019-01-14&rft.volume=125&rft.issue=2&rft.issn=0021-8979&rft.eissn=1089-7550&rft.coden=JAPIAU&rft_id=info:doi/10.1063/1.5070113&rft_dat=%3Cproquest_cross%3E2165523088%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2165523088&rft_id=info:pmid/&rfr_iscdi=true