CCD camera as feasible large-area-size x-ray detector for x-ray fluorescence spectroscopy and imaging
As X-ray fluorescence radiation isotropically spreads from the sample, one of the most important requirements for spectrometers for many years has been a large solid angle. Charge-coupled device (CCD) cameras are quite promising options because they have a fairly large area size, usually larger than...
Gespeichert in:
Veröffentlicht in: | Review of scientific instruments 2017-06, Vol.88 (6), p.063703-063703 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 063703 |
---|---|
container_issue | 6 |
container_start_page | 063703 |
container_title | Review of scientific instruments |
container_volume | 88 |
creator | Zhao, Wenyang Sakurai, Kenji |
description | As X-ray fluorescence radiation isotropically spreads from the sample, one of the most important requirements for spectrometers for many years has been a large solid angle. Charge-coupled device (CCD) cameras are quite promising options because they have a fairly large area size, usually larger than 150 mm2. The present work has examined the feasibility of a commercially available camera with an ordinary CCD chip (1024 × 1024 pixels, the size of one pixel is 13 μm × 13 μm, designed for visible light) as an X-ray fluorescence detector. As X-ray photons create charges in the CCD chip, reading very quickly the amount is the key for this method. It is very simple if the charges always go into one pixel. As the charges quite often spread to several pixels, and sometimes can be lost, it is important to recover the information by filtering out the unsuccessful events. For this, a simple, versatile, and reliable scheme has been proposed. It has been demonstrated that the energy resolution of the present camera is 150 eV at Mn Kα, and also that its overall achievement in seeing minor elements is almost compatible with conventional X-ray fluorescence detectors. When the CCD camera is combined with a micro-pinhole collimator, full field X-ray fluorescence imaging with a spatial resolution of 20 μm becomes possible. Further feasibility in practical X-ray fluorescence analysis is discussed. |
doi_str_mv | 10.1063/1.4985149 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1063_1_4985149</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1915557248</sourcerecordid><originalsourceid>FETCH-LOGICAL-c414t-2bfb715cb5399140f9c6f955200a63797efe9c0d53793a525fde0f7f122d64cc3</originalsourceid><addsrcrecordid>eNp9kE9LxDAQxYMouq4e_AIS8KJC10yapM1R6l9Y8KLnkqaTpUu3XZMWXD-9kV09eHAgTEh-83jzCDkDNgOm0huYCZ1LEHqPTIDlOskUT_fJhLFUJCoT-RE5DmHJYkmAQ3LEc6WyODIhWBR31JoVekNNoA5NaKoWaWv8AhPj0SSh-UT6kXizoTUOaIfeUxfP9sm1Y-8xWOws0rCO374Ptl9vqOlq2qzMoukWJ-TAmTbg6a5PydvD_WvxlMxfHp-L23liBYgh4ZWrMpC2kqnWIJjTVjktJWfMqDTTGTrUltUy3lMjuXQ1Mpc54LxWwtp0Si63umvfv48YhnLVRGttazrsx1CCBillxkUe0Ys_6LIffRfdlRxAQQRTiNTVlrJxq-DRlWsfd_KbElj5nX0J5S77yJ7vFMdqhfUv-RN2BK63QLDNYIam7_5R-wIjpYq0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2116115531</pqid></control><display><type>article</type><title>CCD camera as feasible large-area-size x-ray detector for x-ray fluorescence spectroscopy and imaging</title><source>AIP Journals Complete</source><source>Alma/SFX Local Collection</source><creator>Zhao, Wenyang ; Sakurai, Kenji</creator><creatorcontrib>Zhao, Wenyang ; Sakurai, Kenji</creatorcontrib><description>As X-ray fluorescence radiation isotropically spreads from the sample, one of the most important requirements for spectrometers for many years has been a large solid angle. Charge-coupled device (CCD) cameras are quite promising options because they have a fairly large area size, usually larger than 150 mm2. The present work has examined the feasibility of a commercially available camera with an ordinary CCD chip (1024 × 1024 pixels, the size of one pixel is 13 μm × 13 μm, designed for visible light) as an X-ray fluorescence detector. As X-ray photons create charges in the CCD chip, reading very quickly the amount is the key for this method. It is very simple if the charges always go into one pixel. As the charges quite often spread to several pixels, and sometimes can be lost, it is important to recover the information by filtering out the unsuccessful events. For this, a simple, versatile, and reliable scheme has been proposed. It has been demonstrated that the energy resolution of the present camera is 150 eV at Mn Kα, and also that its overall achievement in seeing minor elements is almost compatible with conventional X-ray fluorescence detectors. When the CCD camera is combined with a micro-pinhole collimator, full field X-ray fluorescence imaging with a spatial resolution of 20 μm becomes possible. Further feasibility in practical X-ray fluorescence analysis is discussed.</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/1.4985149</identifier><identifier>PMID: 28667985</identifier><identifier>CODEN: RSINAK</identifier><language>eng</language><publisher>United States: American Institute of Physics</publisher><subject>CCD cameras ; Charge coupled devices ; Collimation ; Energy resolution ; Feasibility studies ; Filtration ; Photons ; Pinholes ; Pixels ; Scientific apparatus & instruments ; Spatial resolution ; Spectrometers ; X ray detectors ; X ray fluorescence analysis</subject><ispartof>Review of scientific instruments, 2017-06, Vol.88 (6), p.063703-063703</ispartof><rights>Author(s)</rights><rights>2017 Author(s). Published by AIP Publishing.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c414t-2bfb715cb5399140f9c6f955200a63797efe9c0d53793a525fde0f7f122d64cc3</citedby><cites>FETCH-LOGICAL-c414t-2bfb715cb5399140f9c6f955200a63797efe9c0d53793a525fde0f7f122d64cc3</cites><orcidid>0000-0002-2493-2908 ; 0000000224932908</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/rsi/article-lookup/doi/10.1063/1.4985149$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>314,780,784,794,4512,27924,27925,76384</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28667985$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Zhao, Wenyang</creatorcontrib><creatorcontrib>Sakurai, Kenji</creatorcontrib><title>CCD camera as feasible large-area-size x-ray detector for x-ray fluorescence spectroscopy and imaging</title><title>Review of scientific instruments</title><addtitle>Rev Sci Instrum</addtitle><description>As X-ray fluorescence radiation isotropically spreads from the sample, one of the most important requirements for spectrometers for many years has been a large solid angle. Charge-coupled device (CCD) cameras are quite promising options because they have a fairly large area size, usually larger than 150 mm2. The present work has examined the feasibility of a commercially available camera with an ordinary CCD chip (1024 × 1024 pixels, the size of one pixel is 13 μm × 13 μm, designed for visible light) as an X-ray fluorescence detector. As X-ray photons create charges in the CCD chip, reading very quickly the amount is the key for this method. It is very simple if the charges always go into one pixel. As the charges quite often spread to several pixels, and sometimes can be lost, it is important to recover the information by filtering out the unsuccessful events. For this, a simple, versatile, and reliable scheme has been proposed. It has been demonstrated that the energy resolution of the present camera is 150 eV at Mn Kα, and also that its overall achievement in seeing minor elements is almost compatible with conventional X-ray fluorescence detectors. When the CCD camera is combined with a micro-pinhole collimator, full field X-ray fluorescence imaging with a spatial resolution of 20 μm becomes possible. Further feasibility in practical X-ray fluorescence analysis is discussed.</description><subject>CCD cameras</subject><subject>Charge coupled devices</subject><subject>Collimation</subject><subject>Energy resolution</subject><subject>Feasibility studies</subject><subject>Filtration</subject><subject>Photons</subject><subject>Pinholes</subject><subject>Pixels</subject><subject>Scientific apparatus & instruments</subject><subject>Spatial resolution</subject><subject>Spectrometers</subject><subject>X ray detectors</subject><subject>X ray fluorescence analysis</subject><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNp9kE9LxDAQxYMouq4e_AIS8KJC10yapM1R6l9Y8KLnkqaTpUu3XZMWXD-9kV09eHAgTEh-83jzCDkDNgOm0huYCZ1LEHqPTIDlOskUT_fJhLFUJCoT-RE5DmHJYkmAQ3LEc6WyODIhWBR31JoVekNNoA5NaKoWaWv8AhPj0SSh-UT6kXizoTUOaIfeUxfP9sm1Y-8xWOws0rCO374Ptl9vqOlq2qzMoukWJ-TAmTbg6a5PydvD_WvxlMxfHp-L23liBYgh4ZWrMpC2kqnWIJjTVjktJWfMqDTTGTrUltUy3lMjuXQ1Mpc54LxWwtp0Si63umvfv48YhnLVRGttazrsx1CCBillxkUe0Ys_6LIffRfdlRxAQQRTiNTVlrJxq-DRlWsfd_KbElj5nX0J5S77yJ7vFMdqhfUv-RN2BK63QLDNYIam7_5R-wIjpYq0</recordid><startdate>201706</startdate><enddate>201706</enddate><creator>Zhao, Wenyang</creator><creator>Sakurai, Kenji</creator><general>American Institute of Physics</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-2493-2908</orcidid><orcidid>https://orcid.org/0000000224932908</orcidid></search><sort><creationdate>201706</creationdate><title>CCD camera as feasible large-area-size x-ray detector for x-ray fluorescence spectroscopy and imaging</title><author>Zhao, Wenyang ; Sakurai, Kenji</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c414t-2bfb715cb5399140f9c6f955200a63797efe9c0d53793a525fde0f7f122d64cc3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>CCD cameras</topic><topic>Charge coupled devices</topic><topic>Collimation</topic><topic>Energy resolution</topic><topic>Feasibility studies</topic><topic>Filtration</topic><topic>Photons</topic><topic>Pinholes</topic><topic>Pixels</topic><topic>Scientific apparatus & instruments</topic><topic>Spatial resolution</topic><topic>Spectrometers</topic><topic>X ray detectors</topic><topic>X ray fluorescence analysis</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zhao, Wenyang</creatorcontrib><creatorcontrib>Sakurai, Kenji</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Review of scientific instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zhao, Wenyang</au><au>Sakurai, Kenji</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>CCD camera as feasible large-area-size x-ray detector for x-ray fluorescence spectroscopy and imaging</atitle><jtitle>Review of scientific instruments</jtitle><addtitle>Rev Sci Instrum</addtitle><date>2017-06</date><risdate>2017</risdate><volume>88</volume><issue>6</issue><spage>063703</spage><epage>063703</epage><pages>063703-063703</pages><issn>0034-6748</issn><eissn>1089-7623</eissn><coden>RSINAK</coden><abstract>As X-ray fluorescence radiation isotropically spreads from the sample, one of the most important requirements for spectrometers for many years has been a large solid angle. Charge-coupled device (CCD) cameras are quite promising options because they have a fairly large area size, usually larger than 150 mm2. The present work has examined the feasibility of a commercially available camera with an ordinary CCD chip (1024 × 1024 pixels, the size of one pixel is 13 μm × 13 μm, designed for visible light) as an X-ray fluorescence detector. As X-ray photons create charges in the CCD chip, reading very quickly the amount is the key for this method. It is very simple if the charges always go into one pixel. As the charges quite often spread to several pixels, and sometimes can be lost, it is important to recover the information by filtering out the unsuccessful events. For this, a simple, versatile, and reliable scheme has been proposed. It has been demonstrated that the energy resolution of the present camera is 150 eV at Mn Kα, and also that its overall achievement in seeing minor elements is almost compatible with conventional X-ray fluorescence detectors. When the CCD camera is combined with a micro-pinhole collimator, full field X-ray fluorescence imaging with a spatial resolution of 20 μm becomes possible. Further feasibility in practical X-ray fluorescence analysis is discussed.</abstract><cop>United States</cop><pub>American Institute of Physics</pub><pmid>28667985</pmid><doi>10.1063/1.4985149</doi><tpages>11</tpages><orcidid>https://orcid.org/0000-0002-2493-2908</orcidid><orcidid>https://orcid.org/0000000224932908</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0034-6748 |
ispartof | Review of scientific instruments, 2017-06, Vol.88 (6), p.063703-063703 |
issn | 0034-6748 1089-7623 |
language | eng |
recordid | cdi_crossref_primary_10_1063_1_4985149 |
source | AIP Journals Complete; Alma/SFX Local Collection |
subjects | CCD cameras Charge coupled devices Collimation Energy resolution Feasibility studies Filtration Photons Pinholes Pixels Scientific apparatus & instruments Spatial resolution Spectrometers X ray detectors X ray fluorescence analysis |
title | CCD camera as feasible large-area-size x-ray detector for x-ray fluorescence spectroscopy and imaging |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T04%3A45%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=CCD%20camera%20as%20feasible%20large-area-size%20x-ray%20detector%20for%20x-ray%20fluorescence%20spectroscopy%20and%20imaging&rft.jtitle=Review%20of%20scientific%20instruments&rft.au=Zhao,%20Wenyang&rft.date=2017-06&rft.volume=88&rft.issue=6&rft.spage=063703&rft.epage=063703&rft.pages=063703-063703&rft.issn=0034-6748&rft.eissn=1089-7623&rft.coden=RSINAK&rft_id=info:doi/10.1063/1.4985149&rft_dat=%3Cproquest_cross%3E1915557248%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2116115531&rft_id=info:pmid/28667985&rfr_iscdi=true |