Long symmetric high-pressure cell for magnetic measurements in superconducting quantum interference device magnetometer

We describe a high-pressure cell for magnetic measurements in a magnetic property measurement system superconducting quantum interference device (SQUID) magnetometer. The cell has been developed for studies of weakly magnetic materials and has the operating pressure limit of 1GPa. Its design is focu...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Review of scientific instruments 2006-07, Vol.77 (7)
Hauptverfasser: Kamenev, K. V., Tancharakorn, S., Robertson, N., Harrison, A.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 7
container_start_page
container_title Review of scientific instruments
container_volume 77
creator Kamenev, K. V.
Tancharakorn, S.
Robertson, N.
Harrison, A.
description We describe a high-pressure cell for magnetic measurements in a magnetic property measurement system superconducting quantum interference device (SQUID) magnetometer. The cell has been developed for studies of weakly magnetic materials and has the operating pressure limit of 1GPa. Its design is focused on reducing the background signal by making the pressure cell symmetric with respect to the sample in order to provide an integrable SQUID response. The use of an externally loaded cylinder has resulted in the increased strength of the cell and in the provision of a larger sample volume. The optimization of the cell’s length has made it possible to use the approximation of an infinitely long cylinder in the whole range of accessible pressures and to apply the Lamé equation for calculating the change in the diameter of the cell as a function of applied pressure. This enabled us to remove a superconductive manometer from the cell and use the diameter-pressure calibration instead. This has further increased the sensitivity of the measurements at low temperatures which is particularly relevant to studies of weakly magnetic materials. The performance of the cell is illustrated by the results of high-pressure measurements on the molecular antiferromagnet [N(C2H5)4][FeCl4].
doi_str_mv 10.1063/1.2221537
format Article
fullrecord <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_1063_1_2221537</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1063_1_2221537</sourcerecordid><originalsourceid>FETCH-LOGICAL-c330t-744add6ba6f79e8d7a23fc5d0b889434c9b849558bdaee30ee8c6d0471da5d543</originalsourceid><addsrcrecordid>eNotkM1KxDAYRYMoWEcXvkG2LjomTdKkSxn8g4IbXZc0-dqpNGlNUmXe3g4zd3MXB86Fi9A9JVtKSvZIt0VRUMHkBcooUVUuy4JdoowQxvNScnWNbmL8JmsEpRn6qyff43hwDlIYDN4P_T6fA8S4BMAGxhF3U8BO9x7Syh3oI3HgU8SDx3GZIZjJ28WkYTX9LNqnxa0oQegggDeALfwOa50k07oE4RZddXqMcHfuDfp6ef7cveX1x-v77qnODWMk5ZJzbW3Z6rKTFSgrdcE6Iyxplao446ZqFa-EUK3VAIwAKFNawiW1WljB2QY9nLwmTDEG6Jo5DE6HQ0NJc3ysoc35MfYPC35h0w</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Long symmetric high-pressure cell for magnetic measurements in superconducting quantum interference device magnetometer</title><source>AIP Journals Complete</source><source>AIP Digital Archive</source><creator>Kamenev, K. V. ; Tancharakorn, S. ; Robertson, N. ; Harrison, A.</creator><creatorcontrib>Kamenev, K. V. ; Tancharakorn, S. ; Robertson, N. ; Harrison, A.</creatorcontrib><description>We describe a high-pressure cell for magnetic measurements in a magnetic property measurement system superconducting quantum interference device (SQUID) magnetometer. The cell has been developed for studies of weakly magnetic materials and has the operating pressure limit of 1GPa. Its design is focused on reducing the background signal by making the pressure cell symmetric with respect to the sample in order to provide an integrable SQUID response. The use of an externally loaded cylinder has resulted in the increased strength of the cell and in the provision of a larger sample volume. The optimization of the cell’s length has made it possible to use the approximation of an infinitely long cylinder in the whole range of accessible pressures and to apply the Lamé equation for calculating the change in the diameter of the cell as a function of applied pressure. This enabled us to remove a superconductive manometer from the cell and use the diameter-pressure calibration instead. This has further increased the sensitivity of the measurements at low temperatures which is particularly relevant to studies of weakly magnetic materials. The performance of the cell is illustrated by the results of high-pressure measurements on the molecular antiferromagnet [N(C2H5)4][FeCl4].</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/1.2221537</identifier><language>eng</language><ispartof>Review of scientific instruments, 2006-07, Vol.77 (7)</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c330t-744add6ba6f79e8d7a23fc5d0b889434c9b849558bdaee30ee8c6d0471da5d543</citedby><cites>FETCH-LOGICAL-c330t-744add6ba6f79e8d7a23fc5d0b889434c9b849558bdaee30ee8c6d0471da5d543</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids></links><search><creatorcontrib>Kamenev, K. V.</creatorcontrib><creatorcontrib>Tancharakorn, S.</creatorcontrib><creatorcontrib>Robertson, N.</creatorcontrib><creatorcontrib>Harrison, A.</creatorcontrib><title>Long symmetric high-pressure cell for magnetic measurements in superconducting quantum interference device magnetometer</title><title>Review of scientific instruments</title><description>We describe a high-pressure cell for magnetic measurements in a magnetic property measurement system superconducting quantum interference device (SQUID) magnetometer. The cell has been developed for studies of weakly magnetic materials and has the operating pressure limit of 1GPa. Its design is focused on reducing the background signal by making the pressure cell symmetric with respect to the sample in order to provide an integrable SQUID response. The use of an externally loaded cylinder has resulted in the increased strength of the cell and in the provision of a larger sample volume. The optimization of the cell’s length has made it possible to use the approximation of an infinitely long cylinder in the whole range of accessible pressures and to apply the Lamé equation for calculating the change in the diameter of the cell as a function of applied pressure. This enabled us to remove a superconductive manometer from the cell and use the diameter-pressure calibration instead. This has further increased the sensitivity of the measurements at low temperatures which is particularly relevant to studies of weakly magnetic materials. The performance of the cell is illustrated by the results of high-pressure measurements on the molecular antiferromagnet [N(C2H5)4][FeCl4].</description><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><recordid>eNotkM1KxDAYRYMoWEcXvkG2LjomTdKkSxn8g4IbXZc0-dqpNGlNUmXe3g4zd3MXB86Fi9A9JVtKSvZIt0VRUMHkBcooUVUuy4JdoowQxvNScnWNbmL8JmsEpRn6qyff43hwDlIYDN4P_T6fA8S4BMAGxhF3U8BO9x7Syh3oI3HgU8SDx3GZIZjJ28WkYTX9LNqnxa0oQegggDeALfwOa50k07oE4RZddXqMcHfuDfp6ef7cveX1x-v77qnODWMk5ZJzbW3Z6rKTFSgrdcE6Iyxplao446ZqFa-EUK3VAIwAKFNawiW1WljB2QY9nLwmTDEG6Jo5DE6HQ0NJc3ysoc35MfYPC35h0w</recordid><startdate>20060701</startdate><enddate>20060701</enddate><creator>Kamenev, K. V.</creator><creator>Tancharakorn, S.</creator><creator>Robertson, N.</creator><creator>Harrison, A.</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20060701</creationdate><title>Long symmetric high-pressure cell for magnetic measurements in superconducting quantum interference device magnetometer</title><author>Kamenev, K. V. ; Tancharakorn, S. ; Robertson, N. ; Harrison, A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c330t-744add6ba6f79e8d7a23fc5d0b889434c9b849558bdaee30ee8c6d0471da5d543</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kamenev, K. V.</creatorcontrib><creatorcontrib>Tancharakorn, S.</creatorcontrib><creatorcontrib>Robertson, N.</creatorcontrib><creatorcontrib>Harrison, A.</creatorcontrib><collection>CrossRef</collection><jtitle>Review of scientific instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kamenev, K. V.</au><au>Tancharakorn, S.</au><au>Robertson, N.</au><au>Harrison, A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Long symmetric high-pressure cell for magnetic measurements in superconducting quantum interference device magnetometer</atitle><jtitle>Review of scientific instruments</jtitle><date>2006-07-01</date><risdate>2006</risdate><volume>77</volume><issue>7</issue><issn>0034-6748</issn><eissn>1089-7623</eissn><abstract>We describe a high-pressure cell for magnetic measurements in a magnetic property measurement system superconducting quantum interference device (SQUID) magnetometer. The cell has been developed for studies of weakly magnetic materials and has the operating pressure limit of 1GPa. Its design is focused on reducing the background signal by making the pressure cell symmetric with respect to the sample in order to provide an integrable SQUID response. The use of an externally loaded cylinder has resulted in the increased strength of the cell and in the provision of a larger sample volume. The optimization of the cell’s length has made it possible to use the approximation of an infinitely long cylinder in the whole range of accessible pressures and to apply the Lamé equation for calculating the change in the diameter of the cell as a function of applied pressure. This enabled us to remove a superconductive manometer from the cell and use the diameter-pressure calibration instead. This has further increased the sensitivity of the measurements at low temperatures which is particularly relevant to studies of weakly magnetic materials. The performance of the cell is illustrated by the results of high-pressure measurements on the molecular antiferromagnet [N(C2H5)4][FeCl4].</abstract><doi>10.1063/1.2221537</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0034-6748
ispartof Review of scientific instruments, 2006-07, Vol.77 (7)
issn 0034-6748
1089-7623
language eng
recordid cdi_crossref_primary_10_1063_1_2221537
source AIP Journals Complete; AIP Digital Archive
title Long symmetric high-pressure cell for magnetic measurements in superconducting quantum interference device magnetometer
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T05%3A10%3A03IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Long%20symmetric%20high-pressure%20cell%20for%20magnetic%20measurements%20in%20superconducting%20quantum%20interference%20device%20magnetometer&rft.jtitle=Review%20of%20scientific%20instruments&rft.au=Kamenev,%20K.%20V.&rft.date=2006-07-01&rft.volume=77&rft.issue=7&rft.issn=0034-6748&rft.eissn=1089-7623&rft_id=info:doi/10.1063/1.2221537&rft_dat=%3Ccrossref%3E10_1063_1_2221537%3C/crossref%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true