High pressure cells for magnetic measurements—Destruction and functional tests
The design of nonmagnetic CuBe and multilayer ( Cu Be + MP 35 N ) hydrostatic pressure cells for magnetization and magnetostriction measurements in a pressure range up to 2 GPa at temperatures down to 5 K and in fields up to 14 T is presented. The safety operation of the cells is based on destruc...
Gespeichert in:
Veröffentlicht in: | Review of scientific instruments 2004-11, Vol.75 (11), p.5022-5025 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 5025 |
---|---|
container_issue | 11 |
container_start_page | 5022 |
container_title | Review of scientific instruments |
container_volume | 75 |
creator | Kamarád, J. Machátová, Z. Arnold, Z. |
description | The design of nonmagnetic CuBe and multilayer
(
Cu
Be
+
MP
35
N
)
hydrostatic pressure cells for magnetization and magnetostriction measurements in a pressure range up to
2
GPa
at temperatures down to
5
K
and in fields up to
14
T
is presented. The safety operation of the cells is based on destruction tests described in this work. An influence of the pressure cells on measured magnetic magnitudes and the temperature induced pressure changes in the clamped cells have been carefully studied in a temperature range from
350
K
down to
5
K
using different pressure transmitting media. |
doi_str_mv | 10.1063/1.1808122 |
format | Article |
fullrecord | <record><control><sourceid>scitation_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1063_1_1808122</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>rsi</sourcerecordid><originalsourceid>FETCH-LOGICAL-c365t-7836314565e4ab3d531833ead1a537c881eb3153cece67051a6d5c3c6b9b7d513</originalsourceid><addsrcrecordid>eNp9kM1KxDAUhYMoWEcXvkG2Ch1z5zZpZinjzwgDutB1SdPbsdI_klRw50P4hD6JHWfQheDdHC7n43A4jJ2CmIJQeAFT0ELDbLbHIhB6HqdqhvssEgKTWKWJPmRH3r-I8SRAxB6W1fqZ9468HxxxS3Xtedk53ph1S6GyvCGzsRpqg_98_7giH9xgQ9W13LQFL4f2-zE1D6Plj9lBaWpPJzudsKeb68fFMl7d394tLlexRSVDnGpUCIlUkhKTYyERNCKZAozE1GoNlCNItGRJpWNXowpp0ap8nqeFBJyws22udZ33jsqsd1Vj3FsGIttMkUG2m2Jkz7est1Uwm7Y_8GvnfsGsL8r_4L_JX_z-bo8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>High pressure cells for magnetic measurements—Destruction and functional tests</title><source>AIP Journals Complete</source><source>AIP Digital Archive</source><creator>Kamarád, J. ; Machátová, Z. ; Arnold, Z.</creator><creatorcontrib>Kamarád, J. ; Machátová, Z. ; Arnold, Z.</creatorcontrib><description>The design of nonmagnetic CuBe and multilayer
(
Cu
Be
+
MP
35
N
)
hydrostatic pressure cells for magnetization and magnetostriction measurements in a pressure range up to
2
GPa
at temperatures down to
5
K
and in fields up to
14
T
is presented. The safety operation of the cells is based on destruction tests described in this work. An influence of the pressure cells on measured magnetic magnitudes and the temperature induced pressure changes in the clamped cells have been carefully studied in a temperature range from
350
K
down to
5
K
using different pressure transmitting media.</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/1.1808122</identifier><identifier>CODEN: RSINAK</identifier><language>eng</language><ispartof>Review of scientific instruments, 2004-11, Vol.75 (11), p.5022-5025</ispartof><rights>American Institute of Physics</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c365t-7836314565e4ab3d531833ead1a537c881eb3153cece67051a6d5c3c6b9b7d513</citedby><cites>FETCH-LOGICAL-c365t-7836314565e4ab3d531833ead1a537c881eb3153cece67051a6d5c3c6b9b7d513</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/rsi/article-lookup/doi/10.1063/1.1808122$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>314,776,780,790,1553,4497,27903,27904,76131,76137</link.rule.ids></links><search><creatorcontrib>Kamarád, J.</creatorcontrib><creatorcontrib>Machátová, Z.</creatorcontrib><creatorcontrib>Arnold, Z.</creatorcontrib><title>High pressure cells for magnetic measurements—Destruction and functional tests</title><title>Review of scientific instruments</title><description>The design of nonmagnetic CuBe and multilayer
(
Cu
Be
+
MP
35
N
)
hydrostatic pressure cells for magnetization and magnetostriction measurements in a pressure range up to
2
GPa
at temperatures down to
5
K
and in fields up to
14
T
is presented. The safety operation of the cells is based on destruction tests described in this work. An influence of the pressure cells on measured magnetic magnitudes and the temperature induced pressure changes in the clamped cells have been carefully studied in a temperature range from
350
K
down to
5
K
using different pressure transmitting media.</description><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2004</creationdate><recordtype>article</recordtype><recordid>eNp9kM1KxDAUhYMoWEcXvkG2Ch1z5zZpZinjzwgDutB1SdPbsdI_klRw50P4hD6JHWfQheDdHC7n43A4jJ2CmIJQeAFT0ELDbLbHIhB6HqdqhvssEgKTWKWJPmRH3r-I8SRAxB6W1fqZ9468HxxxS3Xtedk53ph1S6GyvCGzsRpqg_98_7giH9xgQ9W13LQFL4f2-zE1D6Plj9lBaWpPJzudsKeb68fFMl7d394tLlexRSVDnGpUCIlUkhKTYyERNCKZAozE1GoNlCNItGRJpWNXowpp0ap8nqeFBJyws22udZ33jsqsd1Vj3FsGIttMkUG2m2Jkz7est1Uwm7Y_8GvnfsGsL8r_4L_JX_z-bo8</recordid><startdate>200411</startdate><enddate>200411</enddate><creator>Kamarád, J.</creator><creator>Machátová, Z.</creator><creator>Arnold, Z.</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>200411</creationdate><title>High pressure cells for magnetic measurements—Destruction and functional tests</title><author>Kamarád, J. ; Machátová, Z. ; Arnold, Z.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c365t-7836314565e4ab3d531833ead1a537c881eb3153cece67051a6d5c3c6b9b7d513</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2004</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kamarád, J.</creatorcontrib><creatorcontrib>Machátová, Z.</creatorcontrib><creatorcontrib>Arnold, Z.</creatorcontrib><collection>CrossRef</collection><jtitle>Review of scientific instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kamarád, J.</au><au>Machátová, Z.</au><au>Arnold, Z.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>High pressure cells for magnetic measurements—Destruction and functional tests</atitle><jtitle>Review of scientific instruments</jtitle><date>2004-11</date><risdate>2004</risdate><volume>75</volume><issue>11</issue><spage>5022</spage><epage>5025</epage><pages>5022-5025</pages><issn>0034-6748</issn><eissn>1089-7623</eissn><coden>RSINAK</coden><abstract>The design of nonmagnetic CuBe and multilayer
(
Cu
Be
+
MP
35
N
)
hydrostatic pressure cells for magnetization and magnetostriction measurements in a pressure range up to
2
GPa
at temperatures down to
5
K
and in fields up to
14
T
is presented. The safety operation of the cells is based on destruction tests described in this work. An influence of the pressure cells on measured magnetic magnitudes and the temperature induced pressure changes in the clamped cells have been carefully studied in a temperature range from
350
K
down to
5
K
using different pressure transmitting media.</abstract><doi>10.1063/1.1808122</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0034-6748 |
ispartof | Review of scientific instruments, 2004-11, Vol.75 (11), p.5022-5025 |
issn | 0034-6748 1089-7623 |
language | eng |
recordid | cdi_crossref_primary_10_1063_1_1808122 |
source | AIP Journals Complete; AIP Digital Archive |
title | High pressure cells for magnetic measurements—Destruction and functional tests |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-22T06%3A27%3A05IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-scitation_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=High%20pressure%20cells%20for%20magnetic%20measurements%E2%80%94Destruction%20and%20functional%20tests&rft.jtitle=Review%20of%20scientific%20instruments&rft.au=Kamar%C3%A1d,%20J.&rft.date=2004-11&rft.volume=75&rft.issue=11&rft.spage=5022&rft.epage=5025&rft.pages=5022-5025&rft.issn=0034-6748&rft.eissn=1089-7623&rft.coden=RSINAK&rft_id=info:doi/10.1063/1.1808122&rft_dat=%3Cscitation_cross%3Ersi%3C/scitation_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |