Current Regulator for Ultraviolet Light Source
In optical experiments where double beam techniques are not applicable, a stable light source is desirable. This paper describes a current regulator for a dc cold cathode hydrogen gas discharge used as an ultraviolet light source. In addition to the discharge current, the light output depends on fac...
Gespeichert in:
Veröffentlicht in: | Review of scientific instruments 1964-04, Vol.35 (4), p.489-492 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 492 |
---|---|
container_issue | 4 |
container_start_page | 489 |
container_title | Review of scientific instruments |
container_volume | 35 |
creator | Scouler, William J. Mills, Elwin D. |
description | In optical experiments where double beam techniques are not applicable, a stable light source is desirable. This paper describes a current regulator for a dc cold cathode hydrogen gas discharge used as an ultraviolet light source. In addition to the discharge current, the light output depends on factors such as gas pressure, but reasonable stability is obtained by simple precise current regulation of ±0.1%. |
doi_str_mv | 10.1063/1.1718853 |
format | Article |
fullrecord | <record><control><sourceid>scitation_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1063_1_1718853</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>rsi</sourcerecordid><originalsourceid>FETCH-LOGICAL-c299t-bcd7b0beddb7c3f8b172695da48b6da00f91d3a813091cf1130f7f107d1fdeed3</originalsourceid><addsrcrecordid>eNp9z81KxDAUBeAgCtbRhW_QrUJrbtM2yVKKjkJBUGcd8jtW6mRI0gHf3soMuhC8cDmbjwMHoUvAJeCW3EAJFBhryBHKADNe0LYixyjDmNRFS2t2is5ifMfzNQAZKrspBLtJ-bNdT6NMPuRu_tWYgtwNfrQp74f1W8pf_BS0PUcnTo7RXhxygVb3d6_dQ9E_LR-7277QFeepUNpQhZU1RlFNHFNAq5Y3RtZMtUZi7DgYIhkQzEE7mNNRB5gacMZaQxboat-rg48xWCe2YfiQ4VMAFt9DBYjD0Nle723UQ5Jp8JsfvPPhF4qtcf_hv81f_Pphvw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Current Regulator for Ultraviolet Light Source</title><source>AIP Digital Archive</source><creator>Scouler, William J. ; Mills, Elwin D.</creator><creatorcontrib>Scouler, William J. ; Mills, Elwin D.</creatorcontrib><description>In optical experiments where double beam techniques are not applicable, a stable light source is desirable. This paper describes a current regulator for a dc cold cathode hydrogen gas discharge used as an ultraviolet light source. In addition to the discharge current, the light output depends on factors such as gas pressure, but reasonable stability is obtained by simple precise current regulation of ±0.1%.</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/1.1718853</identifier><identifier>CODEN: RSINAK</identifier><language>eng</language><ispartof>Review of scientific instruments, 1964-04, Vol.35 (4), p.489-492</ispartof><rights>The American Institute of Physics</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c299t-bcd7b0beddb7c3f8b172695da48b6da00f91d3a813091cf1130f7f107d1fdeed3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/rsi/article-lookup/doi/10.1063/1.1718853$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>314,780,784,1558,27923,27924,76161</link.rule.ids></links><search><creatorcontrib>Scouler, William J.</creatorcontrib><creatorcontrib>Mills, Elwin D.</creatorcontrib><title>Current Regulator for Ultraviolet Light Source</title><title>Review of scientific instruments</title><description>In optical experiments where double beam techniques are not applicable, a stable light source is desirable. This paper describes a current regulator for a dc cold cathode hydrogen gas discharge used as an ultraviolet light source. In addition to the discharge current, the light output depends on factors such as gas pressure, but reasonable stability is obtained by simple precise current regulation of ±0.1%.</description><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1964</creationdate><recordtype>article</recordtype><recordid>eNp9z81KxDAUBeAgCtbRhW_QrUJrbtM2yVKKjkJBUGcd8jtW6mRI0gHf3soMuhC8cDmbjwMHoUvAJeCW3EAJFBhryBHKADNe0LYixyjDmNRFS2t2is5ifMfzNQAZKrspBLtJ-bNdT6NMPuRu_tWYgtwNfrQp74f1W8pf_BS0PUcnTo7RXhxygVb3d6_dQ9E_LR-7277QFeepUNpQhZU1RlFNHFNAq5Y3RtZMtUZi7DgYIhkQzEE7mNNRB5gacMZaQxboat-rg48xWCe2YfiQ4VMAFt9DBYjD0Nle723UQ5Jp8JsfvPPhF4qtcf_hv81f_Pphvw</recordid><startdate>196404</startdate><enddate>196404</enddate><creator>Scouler, William J.</creator><creator>Mills, Elwin D.</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>196404</creationdate><title>Current Regulator for Ultraviolet Light Source</title><author>Scouler, William J. ; Mills, Elwin D.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c299t-bcd7b0beddb7c3f8b172695da48b6da00f91d3a813091cf1130f7f107d1fdeed3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1964</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Scouler, William J.</creatorcontrib><creatorcontrib>Mills, Elwin D.</creatorcontrib><collection>CrossRef</collection><jtitle>Review of scientific instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Scouler, William J.</au><au>Mills, Elwin D.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Current Regulator for Ultraviolet Light Source</atitle><jtitle>Review of scientific instruments</jtitle><date>1964-04</date><risdate>1964</risdate><volume>35</volume><issue>4</issue><spage>489</spage><epage>492</epage><pages>489-492</pages><issn>0034-6748</issn><eissn>1089-7623</eissn><coden>RSINAK</coden><abstract>In optical experiments where double beam techniques are not applicable, a stable light source is desirable. This paper describes a current regulator for a dc cold cathode hydrogen gas discharge used as an ultraviolet light source. In addition to the discharge current, the light output depends on factors such as gas pressure, but reasonable stability is obtained by simple precise current regulation of ±0.1%.</abstract><doi>10.1063/1.1718853</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0034-6748 |
ispartof | Review of scientific instruments, 1964-04, Vol.35 (4), p.489-492 |
issn | 0034-6748 1089-7623 |
language | eng |
recordid | cdi_crossref_primary_10_1063_1_1718853 |
source | AIP Digital Archive |
title | Current Regulator for Ultraviolet Light Source |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-10T19%3A52%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-scitation_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Current%20Regulator%20for%20Ultraviolet%20Light%20Source&rft.jtitle=Review%20of%20scientific%20instruments&rft.au=Scouler,%20William%20J.&rft.date=1964-04&rft.volume=35&rft.issue=4&rft.spage=489&rft.epage=492&rft.pages=489-492&rft.issn=0034-6748&rft.eissn=1089-7623&rft.coden=RSINAK&rft_id=info:doi/10.1063/1.1718853&rft_dat=%3Cscitation_cross%3Ersi%3C/scitation_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |