Emittance studies of the 2.45 GHz permanent magnet ECR ion source

During the past several years different types of permanent magnet 2.45 GHz (electron cyclotron resonance) ion sources were developed for production of singly charged ions. Ion sources of this type are used in the first stage of DRIBs project, and are planned to be used in the MASHA mass separator. T...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Review of Scientific Instruments 2004-05, Vol.75 (5), p.1653-1655
Hauptverfasser: Zelenak, A., Bogomolov, S. L., Yazvitsky, N. Yu
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1655
container_issue 5
container_start_page 1653
container_title Review of Scientific Instruments
container_volume 75
creator Zelenak, A.
Bogomolov, S. L.
Yazvitsky, N. Yu
description During the past several years different types of permanent magnet 2.45 GHz (electron cyclotron resonance) ion sources were developed for production of singly charged ions. Ion sources of this type are used in the first stage of DRIBs project, and are planned to be used in the MASHA mass separator. The emittance of the beam provided by the source is one of the important parameters for these applications. An emittance scanner composed from a set of parallel slits and rotary wire beam profile monitor was used for the studying of the beam emittance characteristics. The emittance of helium and argon ion beams was measured with different shapes of the plasma electrode for several ion source parameters: microwave power, source potential, plasma aperture-puller aperture gap distance, gas pressure. The results of measurements are compared with previous simulations of ion optics.
doi_str_mv 10.1063/1.1691509
format Article
fullrecord <record><control><sourceid>scitation_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1063_1_1691509</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>rsi</sourcerecordid><originalsourceid>FETCH-LOGICAL-c332t-b7b4a1954e5ff1fd3d19d64ab21ca939329d81bb16869b07d3b12fc5257c06393</originalsourceid><addsrcrecordid>eNqdj0tLxDAYRYMoWEcX_oNsFVrzJU3aLIdSZ4QBQXRd8tSKfZBkBP31VmbAvXdzN4fLPQhdAymACHYHBQgJnMgTlAGpZV4Jyk5RRggrc1GV9Tm6iPGdLOEAGVq3Q5-SGo3DMe1t7yKePE5vDtOi5Hiz_cazC4Ma3ZjwoF5Hl3DbPOF-GnGc9sG4S3Tm1Ud0V8deoZf79rnZ5rvHzUOz3uWGMZpyXelSgeSl496Dt8yCtKJUmoJRkklGpa1BaxC1kJpUlmmg3nDKK7OISbZCN4ddE6YYg_PdHPpBha8OSPfr3kF3dF_Y2wMbTZ9UWs7-D_6cwh_YzdazH-yqZbo</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Emittance studies of the 2.45 GHz permanent magnet ECR ion source</title><source>AIP Journals Complete</source><source>AIP Digital Archive</source><creator>Zelenak, A. ; Bogomolov, S. L. ; Yazvitsky, N. Yu</creator><creatorcontrib>Zelenak, A. ; Bogomolov, S. L. ; Yazvitsky, N. Yu</creatorcontrib><description>During the past several years different types of permanent magnet 2.45 GHz (electron cyclotron resonance) ion sources were developed for production of singly charged ions. Ion sources of this type are used in the first stage of DRIBs project, and are planned to be used in the MASHA mass separator. The emittance of the beam provided by the source is one of the important parameters for these applications. An emittance scanner composed from a set of parallel slits and rotary wire beam profile monitor was used for the studying of the beam emittance characteristics. The emittance of helium and argon ion beams was measured with different shapes of the plasma electrode for several ion source parameters: microwave power, source potential, plasma aperture-puller aperture gap distance, gas pressure. The results of measurements are compared with previous simulations of ion optics.</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/1.1691509</identifier><identifier>CODEN: RSINAK</identifier><language>eng</language><ispartof>Review of Scientific Instruments, 2004-05, Vol.75 (5), p.1653-1655</ispartof><rights>American Institute of Physics</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c332t-b7b4a1954e5ff1fd3d19d64ab21ca939329d81bb16869b07d3b12fc5257c06393</citedby><cites>FETCH-LOGICAL-c332t-b7b4a1954e5ff1fd3d19d64ab21ca939329d81bb16869b07d3b12fc5257c06393</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/rsi/article-lookup/doi/10.1063/1.1691509$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>309,310,314,776,780,785,786,790,1553,4498,23909,23910,25118,27901,27902,76127,76133</link.rule.ids></links><search><creatorcontrib>Zelenak, A.</creatorcontrib><creatorcontrib>Bogomolov, S. L.</creatorcontrib><creatorcontrib>Yazvitsky, N. Yu</creatorcontrib><title>Emittance studies of the 2.45 GHz permanent magnet ECR ion source</title><title>Review of Scientific Instruments</title><description>During the past several years different types of permanent magnet 2.45 GHz (electron cyclotron resonance) ion sources were developed for production of singly charged ions. Ion sources of this type are used in the first stage of DRIBs project, and are planned to be used in the MASHA mass separator. The emittance of the beam provided by the source is one of the important parameters for these applications. An emittance scanner composed from a set of parallel slits and rotary wire beam profile monitor was used for the studying of the beam emittance characteristics. The emittance of helium and argon ion beams was measured with different shapes of the plasma electrode for several ion source parameters: microwave power, source potential, plasma aperture-puller aperture gap distance, gas pressure. The results of measurements are compared with previous simulations of ion optics.</description><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2004</creationdate><recordtype>article</recordtype><recordid>eNqdj0tLxDAYRYMoWEcX_oNsFVrzJU3aLIdSZ4QBQXRd8tSKfZBkBP31VmbAvXdzN4fLPQhdAymACHYHBQgJnMgTlAGpZV4Jyk5RRggrc1GV9Tm6iPGdLOEAGVq3Q5-SGo3DMe1t7yKePE5vDtOi5Hiz_cazC4Ma3ZjwoF5Hl3DbPOF-GnGc9sG4S3Tm1Ud0V8deoZf79rnZ5rvHzUOz3uWGMZpyXelSgeSl496Dt8yCtKJUmoJRkklGpa1BaxC1kJpUlmmg3nDKK7OISbZCN4ddE6YYg_PdHPpBha8OSPfr3kF3dF_Y2wMbTZ9UWs7-D_6cwh_YzdazH-yqZbo</recordid><startdate>200405</startdate><enddate>200405</enddate><creator>Zelenak, A.</creator><creator>Bogomolov, S. L.</creator><creator>Yazvitsky, N. Yu</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>200405</creationdate><title>Emittance studies of the 2.45 GHz permanent magnet ECR ion source</title><author>Zelenak, A. ; Bogomolov, S. L. ; Yazvitsky, N. Yu</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c332t-b7b4a1954e5ff1fd3d19d64ab21ca939329d81bb16869b07d3b12fc5257c06393</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2004</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zelenak, A.</creatorcontrib><creatorcontrib>Bogomolov, S. L.</creatorcontrib><creatorcontrib>Yazvitsky, N. Yu</creatorcontrib><collection>CrossRef</collection><jtitle>Review of Scientific Instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zelenak, A.</au><au>Bogomolov, S. L.</au><au>Yazvitsky, N. Yu</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Emittance studies of the 2.45 GHz permanent magnet ECR ion source</atitle><jtitle>Review of Scientific Instruments</jtitle><date>2004-05</date><risdate>2004</risdate><volume>75</volume><issue>5</issue><spage>1653</spage><epage>1655</epage><pages>1653-1655</pages><issn>0034-6748</issn><eissn>1089-7623</eissn><coden>RSINAK</coden><abstract>During the past several years different types of permanent magnet 2.45 GHz (electron cyclotron resonance) ion sources were developed for production of singly charged ions. Ion sources of this type are used in the first stage of DRIBs project, and are planned to be used in the MASHA mass separator. The emittance of the beam provided by the source is one of the important parameters for these applications. An emittance scanner composed from a set of parallel slits and rotary wire beam profile monitor was used for the studying of the beam emittance characteristics. The emittance of helium and argon ion beams was measured with different shapes of the plasma electrode for several ion source parameters: microwave power, source potential, plasma aperture-puller aperture gap distance, gas pressure. The results of measurements are compared with previous simulations of ion optics.</abstract><doi>10.1063/1.1691509</doi><tpages>3</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0034-6748
ispartof Review of Scientific Instruments, 2004-05, Vol.75 (5), p.1653-1655
issn 0034-6748
1089-7623
language eng
recordid cdi_crossref_primary_10_1063_1_1691509
source AIP Journals Complete; AIP Digital Archive
title Emittance studies of the 2.45 GHz permanent magnet ECR ion source
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-30T15%3A48%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-scitation_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Emittance%20studies%20of%20the%202.45%20GHz%20permanent%20magnet%20ECR%20ion%20source&rft.jtitle=Review%20of%20Scientific%20Instruments&rft.au=Zelenak,%20A.&rft.date=2004-05&rft.volume=75&rft.issue=5&rft.spage=1653&rft.epage=1655&rft.pages=1653-1655&rft.issn=0034-6748&rft.eissn=1089-7623&rft.coden=RSINAK&rft_id=info:doi/10.1063/1.1691509&rft_dat=%3Cscitation_cross%3Ersi%3C/scitation_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true