Operational Amplifier Differentiator for Photoemission Studies: Origin and Control of Errors

Errors encountered in time differentiating a voltage signal with a simple high gain operational amplifier differentiator are studied. Numerical and electronic means of correcting these generally small errors are suggested. The circuit, including a linear sweep voltage source, used for photoemission...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Review of scientific instruments 1969-01, Vol.40 (1), p.74-78
Hauptverfasser: Kress, Kenneth A., Lapeyre, Gerald J.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 78
container_issue 1
container_start_page 74
container_title Review of scientific instruments
container_volume 40
creator Kress, Kenneth A.
Lapeyre, Gerald J.
description Errors encountered in time differentiating a voltage signal with a simple high gain operational amplifier differentiator are studied. Numerical and electronic means of correcting these generally small errors are suggested. The circuit, including a linear sweep voltage source, used for photoemission studies in this laboratory is presented. The coefficient of the error terms for this particular circuit are calculated numerically. Presently achieved sensitivity and resolution are discussed.
doi_str_mv 10.1063/1.1683753
format Article
fullrecord <record><control><sourceid>scitation_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1063_1_1683753</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>rsi</sourcerecordid><originalsourceid>FETCH-LOGICAL-c365t-a5face1f67305646535d4a13d1b19aeb0714d6b7476715470e3e81f227d606d43</originalsourceid><addsrcrecordid>eNp90E1LAzEQBuAgCtbqwX-Qq8LWTPO19VZq_YBCBfUmLOkm0ch2s0yi0H_vaoseBAeGuTy8MC8hp8BGwBS_gBGokmvJ98gAWDkptBrzfTJgjItCaVEekqOU3lg_EmBAnpedQ5NDbE1Dp-uuCT44pFfBe4euzcHkiNT3e_8ac3TrkFKP6UN-t8GlS7rE8BJaalpLZ7HNGBsaPZ0jRkzH5MCbJrmT3R2Sp-v54-y2WCxv7mbTRVFzJXNhpDe1A680Z1IJJbm0wgC3sIKJcSumQVi10kIrDVJo5rgrwY_H2iqmrOBDcrbNrTGmhM5XHYa1wU0FrPqqpYJqV0tvz7c21SF_P_6DPyL-wqqz_j_8N_kTi7NxPQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Operational Amplifier Differentiator for Photoemission Studies: Origin and Control of Errors</title><source>AIP Digital Archive</source><creator>Kress, Kenneth A. ; Lapeyre, Gerald J.</creator><creatorcontrib>Kress, Kenneth A. ; Lapeyre, Gerald J.</creatorcontrib><description>Errors encountered in time differentiating a voltage signal with a simple high gain operational amplifier differentiator are studied. Numerical and electronic means of correcting these generally small errors are suggested. The circuit, including a linear sweep voltage source, used for photoemission studies in this laboratory is presented. The coefficient of the error terms for this particular circuit are calculated numerically. Presently achieved sensitivity and resolution are discussed.</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/1.1683753</identifier><identifier>CODEN: RSINAK</identifier><language>eng</language><ispartof>Review of scientific instruments, 1969-01, Vol.40 (1), p.74-78</ispartof><rights>The American Institute of Physics</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c365t-a5face1f67305646535d4a13d1b19aeb0714d6b7476715470e3e81f227d606d43</citedby><cites>FETCH-LOGICAL-c365t-a5face1f67305646535d4a13d1b19aeb0714d6b7476715470e3e81f227d606d43</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/rsi/article-lookup/doi/10.1063/1.1683753$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>314,776,780,1553,27901,27902,76132</link.rule.ids></links><search><creatorcontrib>Kress, Kenneth A.</creatorcontrib><creatorcontrib>Lapeyre, Gerald J.</creatorcontrib><title>Operational Amplifier Differentiator for Photoemission Studies: Origin and Control of Errors</title><title>Review of scientific instruments</title><description>Errors encountered in time differentiating a voltage signal with a simple high gain operational amplifier differentiator are studied. Numerical and electronic means of correcting these generally small errors are suggested. The circuit, including a linear sweep voltage source, used for photoemission studies in this laboratory is presented. The coefficient of the error terms for this particular circuit are calculated numerically. Presently achieved sensitivity and resolution are discussed.</description><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1969</creationdate><recordtype>article</recordtype><recordid>eNp90E1LAzEQBuAgCtbqwX-Qq8LWTPO19VZq_YBCBfUmLOkm0ch2s0yi0H_vaoseBAeGuTy8MC8hp8BGwBS_gBGokmvJ98gAWDkptBrzfTJgjItCaVEekqOU3lg_EmBAnpedQ5NDbE1Dp-uuCT44pFfBe4euzcHkiNT3e_8ac3TrkFKP6UN-t8GlS7rE8BJaalpLZ7HNGBsaPZ0jRkzH5MCbJrmT3R2Sp-v54-y2WCxv7mbTRVFzJXNhpDe1A680Z1IJJbm0wgC3sIKJcSumQVi10kIrDVJo5rgrwY_H2iqmrOBDcrbNrTGmhM5XHYa1wU0FrPqqpYJqV0tvz7c21SF_P_6DPyL-wqqz_j_8N_kTi7NxPQ</recordid><startdate>196901</startdate><enddate>196901</enddate><creator>Kress, Kenneth A.</creator><creator>Lapeyre, Gerald J.</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>196901</creationdate><title>Operational Amplifier Differentiator for Photoemission Studies: Origin and Control of Errors</title><author>Kress, Kenneth A. ; Lapeyre, Gerald J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c365t-a5face1f67305646535d4a13d1b19aeb0714d6b7476715470e3e81f227d606d43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1969</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kress, Kenneth A.</creatorcontrib><creatorcontrib>Lapeyre, Gerald J.</creatorcontrib><collection>CrossRef</collection><jtitle>Review of scientific instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kress, Kenneth A.</au><au>Lapeyre, Gerald J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Operational Amplifier Differentiator for Photoemission Studies: Origin and Control of Errors</atitle><jtitle>Review of scientific instruments</jtitle><date>1969-01</date><risdate>1969</risdate><volume>40</volume><issue>1</issue><spage>74</spage><epage>78</epage><pages>74-78</pages><issn>0034-6748</issn><eissn>1089-7623</eissn><coden>RSINAK</coden><abstract>Errors encountered in time differentiating a voltage signal with a simple high gain operational amplifier differentiator are studied. Numerical and electronic means of correcting these generally small errors are suggested. The circuit, including a linear sweep voltage source, used for photoemission studies in this laboratory is presented. The coefficient of the error terms for this particular circuit are calculated numerically. Presently achieved sensitivity and resolution are discussed.</abstract><doi>10.1063/1.1683753</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0034-6748
ispartof Review of scientific instruments, 1969-01, Vol.40 (1), p.74-78
issn 0034-6748
1089-7623
language eng
recordid cdi_crossref_primary_10_1063_1_1683753
source AIP Digital Archive
title Operational Amplifier Differentiator for Photoemission Studies: Origin and Control of Errors
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-05T12%3A08%3A49IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-scitation_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Operational%20Amplifier%20Differentiator%20for%20Photoemission%20Studies:%20Origin%20and%20Control%20of%20Errors&rft.jtitle=Review%20of%20scientific%20instruments&rft.au=Kress,%20Kenneth%20A.&rft.date=1969-01&rft.volume=40&rft.issue=1&rft.spage=74&rft.epage=78&rft.pages=74-78&rft.issn=0034-6748&rft.eissn=1089-7623&rft.coden=RSINAK&rft_id=info:doi/10.1063/1.1683753&rft_dat=%3Cscitation_cross%3Ersi%3C/scitation_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true