Compact neutron generator for diagnostic applications

In this article we present the description of compact neutron generators with gas-filled tubes that can be used for neutron detector calibration and stability control. The absolute neutron emission was measured with natural diamond detector and appeared to be in 3% agreement with a standard metrolog...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Review of Scientific Instruments 1999-01, Vol.70 (1), p.1104-1106
Hauptverfasser: Kaschuck, Yu. A., Portnov, D. V., Krasilnikov, A. V., Amosov, V. N., Siromukov, S. V.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1106
container_issue 1
container_start_page 1104
container_title Review of Scientific Instruments
container_volume 70
creator Kaschuck, Yu. A.
Portnov, D. V.
Krasilnikov, A. V.
Amosov, V. N.
Siromukov, S. V.
description In this article we present the description of compact neutron generators with gas-filled tubes that can be used for neutron detector calibration and stability control. The absolute neutron emission was measured with natural diamond detector and appeared to be in 3% agreement with a standard metrology monitor. Neutron generators design are discussed in regard to neutron emission anisotropy and stability improvement. Data illustrating the neutron spatial and energy distributions are presented.
doi_str_mv 10.1063/1.1149473
format Article
fullrecord <record><control><sourceid>scitation_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1063_1_1149473</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>rsi</sourcerecordid><originalsourceid>FETCH-LOGICAL-c363t-77bf56cd7b16f3ad8dbd92bb07096c8f49fa2ed6f792dd8693d8ef22beb2d56d3</originalsourceid><addsrcrecordid>eNp9z01LxDAQBuAgCtbVg_-gV4Wu-WiT5ihFV2HBi55DkkmWyG5Tkij4763uogfBgWEuDy_zInRJ8JJgzm7IkpBWtoIdoYrgXjaCU3aMKoxZ23DR9qfoLOdXPE9HSIW6Ie4mbUs9ureS4lhv3OiSLjHVfl4IejPGXIKt9TRtg9UlxDGfoxOvt9ldHO4CvdzfPQ8Pzfpp9TjcrhvLOCuNEMZ33IIwhHumoQcDkhqDBZbc9r6VXlMH3AtJAXouGfTOU2qcodBxYAt0tc-1KeacnFdTCjudPhTB6quvIurQd7bXe5ttKN9v_uD3mH6hmsD_h_8mfwLPhGUN</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Compact neutron generator for diagnostic applications</title><source>AIP Journals Complete</source><source>AIP Digital Archive</source><creator>Kaschuck, Yu. A. ; Portnov, D. V. ; Krasilnikov, A. V. ; Amosov, V. N. ; Siromukov, S. V.</creator><creatorcontrib>Kaschuck, Yu. A. ; Portnov, D. V. ; Krasilnikov, A. V. ; Amosov, V. N. ; Siromukov, S. V.</creatorcontrib><description>In this article we present the description of compact neutron generators with gas-filled tubes that can be used for neutron detector calibration and stability control. The absolute neutron emission was measured with natural diamond detector and appeared to be in 3% agreement with a standard metrology monitor. Neutron generators design are discussed in regard to neutron emission anisotropy and stability improvement. Data illustrating the neutron spatial and energy distributions are presented.</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/1.1149473</identifier><identifier>CODEN: RSINAK</identifier><language>eng</language><ispartof>Review of Scientific Instruments, 1999-01, Vol.70 (1), p.1104-1106</ispartof><rights>American Institute of Physics</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c363t-77bf56cd7b16f3ad8dbd92bb07096c8f49fa2ed6f792dd8693d8ef22beb2d56d3</citedby><cites>FETCH-LOGICAL-c363t-77bf56cd7b16f3ad8dbd92bb07096c8f49fa2ed6f792dd8693d8ef22beb2d56d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/rsi/article-lookup/doi/10.1063/1.1149473$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>310,311,315,781,785,790,791,795,1560,4513,23935,23936,25145,27929,27930,76389,76395</link.rule.ids></links><search><creatorcontrib>Kaschuck, Yu. A.</creatorcontrib><creatorcontrib>Portnov, D. V.</creatorcontrib><creatorcontrib>Krasilnikov, A. V.</creatorcontrib><creatorcontrib>Amosov, V. N.</creatorcontrib><creatorcontrib>Siromukov, S. V.</creatorcontrib><title>Compact neutron generator for diagnostic applications</title><title>Review of Scientific Instruments</title><description>In this article we present the description of compact neutron generators with gas-filled tubes that can be used for neutron detector calibration and stability control. The absolute neutron emission was measured with natural diamond detector and appeared to be in 3% agreement with a standard metrology monitor. Neutron generators design are discussed in regard to neutron emission anisotropy and stability improvement. Data illustrating the neutron spatial and energy distributions are presented.</description><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1999</creationdate><recordtype>article</recordtype><recordid>eNp9z01LxDAQBuAgCtbVg_-gV4Wu-WiT5ihFV2HBi55DkkmWyG5Tkij4763uogfBgWEuDy_zInRJ8JJgzm7IkpBWtoIdoYrgXjaCU3aMKoxZ23DR9qfoLOdXPE9HSIW6Ie4mbUs9ureS4lhv3OiSLjHVfl4IejPGXIKt9TRtg9UlxDGfoxOvt9ldHO4CvdzfPQ8Pzfpp9TjcrhvLOCuNEMZ33IIwhHumoQcDkhqDBZbc9r6VXlMH3AtJAXouGfTOU2qcodBxYAt0tc-1KeacnFdTCjudPhTB6quvIurQd7bXe5ttKN9v_uD3mH6hmsD_h_8mfwLPhGUN</recordid><startdate>199901</startdate><enddate>199901</enddate><creator>Kaschuck, Yu. A.</creator><creator>Portnov, D. V.</creator><creator>Krasilnikov, A. V.</creator><creator>Amosov, V. N.</creator><creator>Siromukov, S. V.</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>199901</creationdate><title>Compact neutron generator for diagnostic applications</title><author>Kaschuck, Yu. A. ; Portnov, D. V. ; Krasilnikov, A. V. ; Amosov, V. N. ; Siromukov, S. V.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c363t-77bf56cd7b16f3ad8dbd92bb07096c8f49fa2ed6f792dd8693d8ef22beb2d56d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1999</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kaschuck, Yu. A.</creatorcontrib><creatorcontrib>Portnov, D. V.</creatorcontrib><creatorcontrib>Krasilnikov, A. V.</creatorcontrib><creatorcontrib>Amosov, V. N.</creatorcontrib><creatorcontrib>Siromukov, S. V.</creatorcontrib><collection>CrossRef</collection><jtitle>Review of Scientific Instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kaschuck, Yu. A.</au><au>Portnov, D. V.</au><au>Krasilnikov, A. V.</au><au>Amosov, V. N.</au><au>Siromukov, S. V.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Compact neutron generator for diagnostic applications</atitle><jtitle>Review of Scientific Instruments</jtitle><date>1999-01</date><risdate>1999</risdate><volume>70</volume><issue>1</issue><spage>1104</spage><epage>1106</epage><pages>1104-1106</pages><issn>0034-6748</issn><eissn>1089-7623</eissn><coden>RSINAK</coden><abstract>In this article we present the description of compact neutron generators with gas-filled tubes that can be used for neutron detector calibration and stability control. The absolute neutron emission was measured with natural diamond detector and appeared to be in 3% agreement with a standard metrology monitor. Neutron generators design are discussed in regard to neutron emission anisotropy and stability improvement. Data illustrating the neutron spatial and energy distributions are presented.</abstract><doi>10.1063/1.1149473</doi><tpages>3</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0034-6748
ispartof Review of Scientific Instruments, 1999-01, Vol.70 (1), p.1104-1106
issn 0034-6748
1089-7623
language eng
recordid cdi_crossref_primary_10_1063_1_1149473
source AIP Journals Complete; AIP Digital Archive
title Compact neutron generator for diagnostic applications
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-14T20%3A44%3A28IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-scitation_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Compact%20neutron%20generator%20for%20diagnostic%20applications&rft.jtitle=Review%20of%20Scientific%20Instruments&rft.au=Kaschuck,%20Yu.%20A.&rft.date=1999-01&rft.volume=70&rft.issue=1&rft.spage=1104&rft.epage=1106&rft.pages=1104-1106&rft.issn=0034-6748&rft.eissn=1089-7623&rft.coden=RSINAK&rft_id=info:doi/10.1063/1.1149473&rft_dat=%3Cscitation_cross%3Ersi%3C/scitation_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true